Rate of thrombus accumulation on intravenacaval IVOX devices explanted from human clinical trial patients with acute respiratory failure.

Abstract:

:The weight gain of IVOX devices removed from the first 49 human clinical trials patients after from 1 to 29 days of implantation into the venae caval blood stream has been assessed. Each patient had received sufficient systemic heparin to maintain activated clotting times between 150 and 200 s while the IVOX device was indwelling. The nature of the material accumulating on the IVOX device was documented histologically as being thrombus in various stages of development. The weight gain findings indicate that an average of 2.0 g of thrombus accumulates per 24 h on IVOX devices indwelling in the venous blood stream of moderately anticoagulated human acute respiratory failure patients. The rate of weight gain per 24 h of the IVOX device was more rapid during the first 96 h after its implantation than during its second, third, or fourth week of implantation. The accumulated thrombus on the IVOX hollow fibers was associated with a small but measurable decrease (approximately 1%/day) in gas transfer efficiency of the implanted device. The data support the conclusion that IVOX can function effectively and safely without major thrombus formation for up to 29 days in moderately anticoagulated human acute respiratory failure patients.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Imai H,Schaap RN,Mortensen JD

doi

10.1111/j.1525-1594.1994.tb03329.x

subject

Has Abstract

pub_date

1994-11-01 00:00:00

pages

818-21

issue

11

eissn

0160-564X

issn

1525-1594

journal_volume

18

pub_type

杂志文章
  • Adult polycystic kidney disease: who needs hospital follow-up?

    abstract::Clinical data from 120 adult patients with genetically undifferentiated polycystic kidney disease who had been followed up for more than 3 months (range 3-172) were reviewed in order to try to identify clinical indicators that might predict deterioration in renal function. They were split into two groups dependent on ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2012.01441.x

    authors: Griveas I,Bishop K,World M

    更新日期:2012-07-01 00:00:00

  • Surgical use of fluosol-DA in Jehovah's Witness patients.

    abstract::The effects of Fluosol-DA 20% on circulating blood cells, hemodynamic parameters, blood gases, and organs are described and compared with the results of phase I human studies and animal experiments. Bleeding of preoperative anemia and/or surgical bleeding, Fluosol-DA 20% was administered to 7 of 10 Jehovah's Witness p...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04238.x

    authors: Ohyanagi H,Nakaya S,Okumura S,Saitoh Y

    更新日期:1984-02-01 00:00:00

  • Isoelastic polyurethane prosthesis for segmental trachea replacement in beagle dogs.

    abstract::Porous polyurethane (nonwoven) was used for the development of tracheal prosthesis, which--in a special testing design--was adapted to shape and biomechanic properties of the natural organ. This prosthesis was implanted into 19 beagle dogs using inverted, everted, and end-to-end anastomosis. Insufficiency of the anast...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1989.tb02866.x

    authors: Schauwecker HH,Gerlach J,Planck H,Bücherl ES

    更新日期:1989-06-01 00:00:00

  • Intermittent stops of shear reduce the mechanical damage of red blood cells.

    abstract::Continuous and intermittent high shear were loaded to red blood cells in a cone and a plate rheoscope. The mechanical damage to red cells was compared for continuous and intermittent shear. The intermittent shear was achieved by alternately starting and stopping shear repeatedly. In the case of intermittent shear load...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00408.x

    authors: Mizunuma H,Sakai S

    更新日期:2007-06-01 00:00:00

  • Central Extracorporeal Life Support With Left Ventricular Decompression to Berlin Heart Excor: A Reliable "Bridge to Bridge" Strategy in Crash and Burn Patients.

    abstract::The aim of this study was to compare patients with severe biventricular heart failure who underwent Berlin Heart Excor implantation with (cardiogenic shock [CS] status) or without the need for preoperative extracorporeal life support (ECLS) as a bridge to long-term device. A total of 40 consecutive patients with sever...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12792

    authors: Weymann A,Farag M,Sabashnikov A,Fatullayev J,Zeriouh M,Schmack B,Arif R,Müller F,Alt C,Raake P,Prakash Patil N,Popov AF,Rüdiger Simon A,Karck M,Ruhparwar A,Heidelberg-Cologne-Harefield Cardiothoracic Transplantation & Mecha

    更新日期:2017-06-01 00:00:00

  • Biomechanical properties of decellularized porcine pulmonary valve conduits.

    abstract::Tissue-engineered heart valves constructed from a xenogeneic or allogeneic decellularized matrix might overcome the disadvantages of current heart valve substitutes. One major necessity besides effective decellularization is to preserve the biomechanical properties of the valve. Native and decellularized porcine pulmo...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00452.x

    authors: Seebacher G,Grasl C,Stoiber M,Rieder E,Kasimir MT,Dunkler D,Simon P,Weigel G,Schima H

    更新日期:2008-01-01 00:00:00

  • Constraint stress, microstructural characteristics, and enhanced mechanical properties of a special fibroblast-embedded collagen construct.

    abstract::Cell-contracted collagen gels could provide rejection-free biomaterials for tissue engineering, but their application is limited by relatively low mechanical strength. We developed a special type I collagen construct (based on embedded fibroblasts) that was formed into a gel thread by using two anchors to constrain ge...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2006.00314.x

    authors: Feng Z,Ishibashi M,Nomura Y,Kitajima T,Nakamura T

    更新日期:2006-11-01 00:00:00

  • Thromboembolic complications of the Symbion AVAD System.

    abstract::The Symbion Acute Ventricular Assist Device (AVAD) System is an experimental paracorporeal pulsatile ventricular assist device (VAD) for single or biventricular assist. Eleven patients were implanted but 2 died within 24 h and were excluded from the study. Nine patients, four with left ventricular assist devices (LVAD...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1989.tb01575.x

    authors: Icenogle TB,Smith RG,Cleavinger M,Vasu MA,Williams RJ,Sethi GK,Copeland JG

    更新日期:1989-12-01 00:00:00

  • Sensitivity of the primary stability of a cementless hip stem to its position and orientation.

    abstract::Using computed tomography (CT)-based preoperative planning software, we can define with good accuracy the position of a cementless hip stem inside the host bone, but previous studies suggest that the pose the surgeon achieves during freehand surgery may differ from the planned one even by some millimeters. Advances in...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00577.x

    authors: Reggiani B,Cristofolini L,Taddei F,Viceconti M

    更新日期:2008-07-01 00:00:00

  • The effects of homologous cross-circulation and in situ liver perfusion on fulminant hepatic failure rats.

    abstract::A galactosamine-induced fulminant hepatic failure (FHF) rat model was used to study the effects of homologous cross-circulation and in situ liver perfusion. Cross-circulation with homologous donors did not significantly improve the survival time or recovery rate of grade II hepatic coma rats. Homologous in situ liver ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1980.tb03929.x

    authors: Mohsini K,Lister C,Chang TM

    更新日期:1980-08-01 00:00:00

  • Magnetic suspension of the rotor of a ventricular assist device of mixed flow type.

    abstract::This work presents results of preliminary studies concerning application of magnetic bearing in a ventricular assist device (VAD) being developed by Dante Pazzanese Institute of Cardiology-IDPC (São Paulo, Brazil). The VAD-IDPC has a novel architecture that distinguishes from other known VADs. In this, the rotor has a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00551.x

    authors: Horikawa O,de Andrade AJ,da Silva I,Bock EG

    更新日期:2008-04-01 00:00:00

  • The DeBakey ventricular assist device: current status in 1997.

    abstract::In 1993, the development began of a small axial flow blood pump, the DeBakey ventricular assist device (VAD). The material was recently converted to a titanium alloy, and a waterproof pump package was incorporated for long-term intracorporeal circulation. Thirteen intrathoracic implantations in calves were achieved. N...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1046/j.1525-1594.1999.06300.x

    authors: Tayama E,Olsen DB,Ohashi Y,Benkowski R,Morley D,Noon GP,Nosé Y,Debakey ME

    更新日期:1999-12-01 00:00:00

  • Reversal of experimental posthepatectomy liver failure in pigs: a new application of hepatocyte bioreactors.

    abstract::Postoperative liver failure remains a major cause of morbidity and mortality after extensive hepatectomies. This study aims to evaluate the effectiveness of a hepatocyte bioreactor in the treatment of experimental post-hepatectomy liver failure. Our experimental model included a combination of a side-to-side portacava...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01016.x

    authors: Arkadopoulos N,Kostopanagiotou G,Nastos C,Papalois A,Papoutsidakis N,Kalimeris K,Defterevos G,Kanna T,Polyzois K,Kampouroglou G,Kypriotis D,Costopanagiotou C,Pafiti A,Tzanatos H,Smyrniotis V

    更新日期:2011-01-01 00:00:00

  • Effects of pK variability on bicarbonate balance evaluation in dialysis patients.

    abstract::Bicarbonate balance is usually calculated from the Henderson-Hasselbalch equation under the assumption that pK is constant. To evaluate the pK variability and its effects on bicarbonate computed with autoanalyzers in dialysis patients, we studied 44 patients on maintenance hemodialysis. The pH, PCO2, total CO2, and pK...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1987.tb02715.x

    authors: Santoro A,Ferrari G,Spongano M,Cavalli F,Zucchelli P

    更新日期:1987-12-01 00:00:00

  • Effects of pyridoxalated hemoglobin polyoxyethylene conjugate and other hemoglobin-related substances on arterial blood pressure in anesthetized and conscious rats.

    abstract::The effects of pyridoxalated hemoglobin polyoxyethylene conjugate (PHP) and other hemoglobin-related substances on arterial blood pressure (ABP) and heart rate (HR) were examined. Infusion of PHP and other hemoglobin-related substances elevated ABP and increased HR. The degree of the increase in ABP and HR did not dif...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02300.x

    authors: Kida Y,Maeda M,Iwata S,Iwashita Y,Goto K,Nishi K

    更新日期:1995-02-01 00:00:00

  • Centrifugal pumps and heparin-coated circuits in surgical treatment of giant cerebral aneurysms.

    abstract::Giant cerebral aneurysms may be untreatable by conventional neurosurgical techniques. Early attempts to use circulatory assistance and deep hypothermia were abandoned due to hemorrhagic complications. More recently, interest in circulatory support for complex neurosurgical procedures has been renewed. A consecutive se...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06594.x

    authors: Mesana T,Collart F,Caus T,Pomane C,Graziani N,Bruder N,Dufour H,Grisoli F,Montiès JR

    更新日期:2000-06-01 00:00:00

  • A nonsurgical technique for blood access in extracorporeal affinity adsorption of antibodies in rats.

    abstract::Monoclonal antibodies for targeting cytotoxic conjugates to tumor cells are currently being evaluated together with extracorporeal affinity adsorption. The aim of the adsorption was to reduce undesired side effects in normal organs and to increase the tumor-to-normal tissue ratios. This technique is also applicable to...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00380.x

    authors: Mårtensson L,Nilsson R,Sjögren HO,Strand SE,Tennvall J

    更新日期:2007-04-01 00:00:00

  • Experiencing Functional Electrical Stimulation Roots on Education, and Clinical Developments in Paraplegia and Tetraplegia With Technological Innovation.

    abstract::Cybernetics-based concepts can allow for complete independence for paralyzed individuals, including sensory motor recovery. Spinal cord injuries are responsible for a huge stress on health and a financial burden to society. This article focuses on novel procedures such as functional diagnosis for paraplegics and tetra...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/aor.12620

    authors: Varoto R,Cliquet A Jr

    更新日期:2015-10-01 00:00:00

  • Heparin-coated cardiopulmonary bypass circuits in coronary bypass surgery.

    abstract::Cardiopulmonary bypass (CPB) is a nonphysiologic environment for an organism. The damage of blood components may also lead to organ dysfunction, some-times recognized as postperfusion syndrome. One possible way to diminish the risk of these complications would be to reduce the thorombogenicity and to improve the bioco...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1996.tb04573.x

    authors: Horimoto H,Kondo K,Asada K,Sasaki S

    更新日期:1996-08-01 00:00:00

  • The PediPump: a new ventricular assist device for children.

    abstract::Options for mechanical circulatory support for the treatment of end-stage heart failure in children are limited. Ventricular assist devices (VADs), which have revolutionized cardiac care in adults, remain largely unavailable for pediatric applications. The PediPump is a new rotary dynamic VAD designed to provide suppo...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29088.x

    authors: Duncan BW,Lorenz M,Kopcak MW,Fukamachi K,Ootaki Y,Chen HM,Chapman PA,Davis SJ,Smith WA

    更新日期:2005-07-01 00:00:00

  • Paracorporeal assistance system for restoring cardiac activity.

    abstract::Two series of experiments were conducted to assess the potential of artificial ventricular bypass in restoring cardiac activity. One series evaluated use of a paracorporeal left ventricle in 17 calves; the other evaluated biventricular bypass in 11 calves. Module pumps with a seamless blood chamber of polyurethane wer...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1987.tb02622.x

    authors: Tolpekin VE,Koblov LF,Kuvaev AE,Gasanov EK

    更新日期:1987-02-01 00:00:00

  • Detection of suction and regurgitation of the implantable centrifugal pump based on the motor current waveform analysis and its application to optimization of pump flow.

    abstract::In this study, a detection algorithm for suction and regurgitation of the centrifugal pump during left heart bypass without relying on external flow or pressure sensors was developed and evaluated in acute studies using adult goats. The detection scheme relies on power spectral density (PSD) analysis of the motor curr...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06397.x

    authors: Yuhki A,Hatoh E,Nogawa M,Miura M,Shimazaki Y,Takatani S

    更新日期:1999-06-01 00:00:00

  • Coronary artery bypass grafting for dialysis patients: usefulness of multiarterial bypass.

    abstract::This study assessed the efficacy of multiarterial bypass in coronary artery bypass grafting (CABG) in dialysis patients. Eighty dialysis patients who underwent CABG were divided into 2 groups. Group A consisted of 38 patients in whom the left internal thoracic artery and additional saphenous vein graft (SVG) had been ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Nakayama Y,Sakata R,Ura M

    更新日期:2001-04-01 00:00:00

  • Numerical modeling of blood flow in the ventricular cavity of the artificial heart.

    abstract::The flow of blood as a viscous, Newtonian, incompressible liquid in an expanding spherical cavity with a ball-type inlet valve was examined. This type of flow can serve as a model of the phase of ventricular diastole in a sac-type artificial heart. The critical values of Reynolds numbers at which flow interruption beh...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1983.tb04170.x

    authors: Starobin IM,Zaĭko VM

    更新日期:1983-02-01 00:00:00

  • A computational study of the effects of inlet guide vanes on the performance of a centrifugal blood pump.

    abstract::This article presents computational studies on the effects of inlet guide vanes (IGVs) on the flow pattern and shear stress in a centrifugal blood pump. The effect of IGVs is to introduce a pre-swirl to fluid particles entering the impeller with the intention that the fluid particles will travel along the blade profil...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.06917.x

    authors: Chan WK,Wong YW,Yu SC,Chua LP

    更新日期:2002-06-01 00:00:00

  • The compliance problem: a major obstacle in the development of implantable blood pumps.

    abstract::The compliance problem represents a major obstacle in the development of implantable blood pumps. The motor-driven pumps are enclosed in an airtight casing with gas in the motor space. The trapped gas in the motor space either increases the load on the motor during systole or impedes blood sac filling. Potential solut...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04248.x

    authors: Lee S,Rosenberg G,Donachy JH,Wisman CB,Pierce WS

    更新日期:1984-02-01 00:00:00

  • A comparative study between flow visualization and computational fluid dynamic analysis for the sun medical centrifugal blood pump.

    abstract::Flow visualization experiments and computational fluid dynamic (CFD) analyses were performed and the results were compared to clarify the detailed fluid dynamic characteristics for the prototype design of a centrifugal pump, namely, an implantable ventricular assist system from Sun Medical, whose hemocompatibility was...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.07161.x

    authors: Yamane T,Miyamoto Y,Tajima K,Yamazaki K

    更新日期:2004-05-01 00:00:00

  • Engineering of vascular grafts with genetically modified bone marrow mesenchymal stem cells on poly (propylene carbonate) graft.

    abstract::Bone marrow mesenchymal stem cells (MSCs) have demonstrated their pluripotency to differentiate into different cell lineages and may be an alternative cell source for vascular tissue engineering. The objective of this study is to create small diameter vessels by seeding and culture of genetically modified MSCs onto a ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2006.00322.x

    authors: Zhang J,Qi H,Wang H,Hu P,Ou L,Guo S,Li J,Che Y,Yu Y,Kong D

    更新日期:2006-12-01 00:00:00

  • Technical aspects on middle molecules: separation, isolation, and identification.

    abstract::For the last few years we have attempted to separate and isolate from biological fluids the uremic Middle Molecules (MM). The first step in the treatment of plasma is an ultrafiltration through AN69 membrane. The samples are fractionated by Sephadex G-15 chromatography into 9 peaks "a" to "i' under precise conditions ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Cueille G,Man NK,Sausse A,Farges JP,Funck-Brentano JL

    更新日期:1981-01-01 00:00:00

  • Effect of Continuous-Flow Mechanical Circulatory Support on Microvasculature Remodeling in the Failing Heart.

    abstract::Left ventricle (LV) unloading caused by a left ventricular assist device (LVAD) has been shown to enhance reverse LV remodeling in end-stage cardiomyopathy. Several reports consistently suggest that a pulsatile-flow LVAD has more profound effects compared to continuous-flow LVAD, though the responsible mechanisms are ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13348

    authors: Saito T,Miyagawa S,Toda K,Yoshikawa Y,Fukushima S,Saito S,Yoshioka D,Sakata Y,Daimon T,Sawa Y

    更新日期:2019-04-01 00:00:00