On the suitability of ultrathin detectors for absorbed dose assessment in the presence of high-density heterogeneities.

Abstract:

PURPOSE:The aim of this study was to evaluate the suitability of several detectors for the determination of absorbed dose in bone. METHODS:Three types of ultrathin LiF-based thermoluminescent dosimeters (TLDs)-two LiF:Mg,Cu,P-based (MCP-Ns and TLD-2000F) and a (7)Li-enriched LiF:Mg,Ti-based (MTS-7s)-as well as EBT2 Gafchromic films were used to measure percentage depth-dose distributions (PDDs) in a water-equivalent phantom with a bone-equivalent heterogeneity for 6 and 18 MV and a set of field sizes ranging from 5 x 5 cm2 to 20 x 20 cm2. MCP-Ns, TLD-2000F, MTS-7s, and EBT2 have active layers of 50, 20, 50, and 30 μm, respectively. Monte Carlo (MC) dose calculations (PENELOPE code) were used as the reference and helped to understand the experimental results and to evaluate the potential perturbation of the fluence in bone caused by the presence of the detectors. The energy dependence and linearity of the TLDs' response was evaluated. RESULTS:TLDs exhibited flat energy responses (within 2.5%) and linearity with dose (within 1.1%) within the range of interest for the selected beams. The results revealed that all considered detectors perturb the electron fluence with respect to the energy inside the bone-equivalent material. MCP-Ns and MTS-7s underestimated the absorbed dose in bone by 4%-5%. EBT2 exhibited comparable accuracy to MTS-7s and MCP-Ns. TLD-2000F was able to determine the dose within 2% accuracy. No dependence on the beam energy or field size was observed. The MC calculations showed that a[Formula: see text] thick detector can provide reliable dose estimations in bone regardless of whether it is made of LiF, water or EBT's active layer material. CONCLUSIONS:TLD-2000F was found to be suitable for providing reliable absorbed dose measurements in the presence of bone for high-energy x-ray beams.

journal_name

Med Phys

journal_title

Medical physics

authors

Bueno M,Carrasco P,Jornet N,Muñoz-Montplet C,Duch MA

doi

10.1118/1.4886760

subject

Has Abstract

pub_date

2014-08-01 00:00:00

pages

081710

issue

8

eissn

0094-2405

issn

2473-4209

journal_volume

41

pub_type

杂志文章
  • WE-E-213CD-03: Inverse-Consistent Symmetric Registration of Inner Colon Surfaces Derived from Prone and Supine CT Colonography.

    abstract:PURPOSE:Robust registration of prone and supine colonie surfaces acquired during CT colonography may lead to faster and more accurate detection of colorectal cancer and polyps. Any directional bias when registering one surface to the other could precipitate incorrect anatomical correspondence and engender reader error....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736159

    authors: Roth H,McClelland J,Modat M,Hampshire T,Boone D,Hu M,Ourselin S,Halligan S,Hawkes D

    更新日期:2012-06-01 00:00:00

  • Beam scanning for heavy charged particle radiotherapy.

    abstract::An important aspect of heavy charged particle radiotherapy is its ability to localize dose to the target volume. Current techniques generally employ beam delivery schemes which use range modulated beams in which the Bragg peak is spread out over a range of depths. The range modulation is constant over the entire beam ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595419

    authors: Goitein M,Chen GT

    更新日期:1983-11-01 00:00:00

  • Efficient generation of a magnetic field-free line.

    abstract:PURPOSE:Signal encoding in magnetic particle imaging (MPI) is achieved by moving a field-free point (FFP) through the region of interest. One way to increase the sensitivity of the method is to scan the region of interest with a field-free line (FFL) instead of the FFP. Recently, the first feasible FFL coil setup was i...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1118/1.3447726

    authors: Knopp T,Erbe M,Biederer S,Sattel TF,Buzug TM

    更新日期:2010-07-01 00:00:00

  • Comparison of exposure standards in the mammography x-ray region.

    abstract::Direct comparisons of the National Institute of Standards and Technology's (NIST) Ritz 20 kV to 100 kV standard free-air ionization chamber and a portable variable-length free-air ionization chamber designed by the University of Wisconsin-Madison Accredited Dosimetry Calibration Laboratory (UW-ADCL) were made on NISTs...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598148

    authors: Coletti JG,Pearson DW,DeWerd LA,O'Brien CM,Lamperti PJ

    更新日期:1997-08-01 00:00:00

  • A dosimetry study of the Oncoseed 6711 using glass rod dosimeters and EGS5 Monte Carlo code in a geometry lacking radiation equilibrium scatter conditions.

    abstract:PURPOSE:The aim of this study was to develop a dose calculation method which is applicable to the interseed attenuation and the geometry lacking the equilibrium radiation scatter conditions in brachytherapy. METHODS:The dose obtained from measurement with a radiophotoluminescent glass rod dosimeter (GRD) was compared ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3590370

    authors: Tanaka K,Tateoka K,Asanuma O,Kamo K,Bengua G,Sato K,Ueda T,Takeda H,Takagi M,Hareyama M,Takada J

    更新日期:2011-06-01 00:00:00

  • Comparison of proton and x-ray conformal dose distributions for radiosurgery applications.

    abstract::Highly focused dose distributions for radiosurgery applications are successfully achieved using either multiple static high-energy particle beams or multiple-arc circular x-ray beams from a linac. It has been suggested that conformal x-ray techniques using dynamically shaped beams with a moving radiation source would ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597654

    authors: Serago CF,Thornton AF,Urie MM,Chapman P,Verhey L,Rosenthal SJ,Gall KP,Niemierko A

    更新日期:1995-12-01 00:00:00

  • Iterative algebraic reconstruction algorithms for emission computed tomography: a unified framework and its application to positron emission tomography.

    abstract::In this paper, a unified framework of iterative algebraic reconstruction for emission computed tomography (ECT) and its application to positron emission tomography (PET) is presented. The unified framework is based on an algebraic image restoration model and contains conventional iterative algebraic reconstruction alg...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596954

    authors: Xu XL,Liow JS,Strother SC

    更新日期:1993-11-01 00:00:00

  • Multiple Feature-based Portal Vein Classification for Liver Segments Extraction.

    abstract:PURPOSE:The liver segments divided by Couinaud classification method are used to understand the functional anatomy of liver, which is significant in hepatic resection surgery. In Couinaud classification method, each third-order branch of the portal vein (PV) defines the supplied territory of a corresponding liver segme...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14745

    authors: Wu C,Fu T,Gao Y,Liu Y,Fan J,Ai D,Song H,Yang J

    更新日期:2021-02-02 00:00:00

  • Measurement of LINAC 90 degrees head leakage radiation TVL values.

    abstract::One of the key components in modern LINAC room shielding design is the amount of 90 degrees head leakage radiation levels. With the general clinical acceptance of intensity-modulated radiation therapy (IMRT) technique, accurate knowledge of this quantity has become even more important. Measurement of 90 degrees head l...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2335489

    authors: Li Z,Mutic S,Low D

    更新日期:2006-09-01 00:00:00

  • Thermal limits on MV x-ray production by bremsstrahlung targets in the context of novel linear accelerators.

    abstract:PURPOSE:To study the impact of target geometrical and linac operational parameters, such as target material and thickness, electron beam size, repetition rate, and mean current on the ability of the radiotherapy treatment head to deliver high-dose-rate x-ray irradiation in the context of novel linear accelerators capab...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12615

    authors: Wang J,Trovati S,Borchard PM,Loo BW Jr,Maxim PG,Fahrig R

    更新日期:2017-12-01 00:00:00

  • A new open-source GPU-based microscopic Monte Carlo simulation tool for the calculations of DNA damages caused by ionizing radiation - Part II: sensitivity and uncertainty analysis.

    abstract:PURPOSE:Calculations of deoxyribonucleic acid (DNA) damages involve many parameters in the computation process. As these parameters are often subject to uncertainties, it is of central importance to comprehensively quantify their impacts on DNA single-strand break (SSB) and double-strand break (DSB) yields. This has be...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14036

    authors: Lai Y,Tsai MY,Tian Z,Qin N,Yan C,Hung SH,Chi Y,Jia X

    更新日期:2020-04-01 00:00:00

  • Evaluation of a device for indirect assessment of automatic exposure control systems.

    abstract::A test device which can indirectly measure the performance of an automatic exposure control system and which offers the potential to reduce the time and film requirements for such tests has been evaluated. Evaluation results demonstrate that the device can successfully predict image optical density to within +/- 0.10 ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597252

    authors: Rossi RP

    更新日期:1994-01-01 00:00:00

  • The NMR blood flowmeter--applications.

    abstract::Nuclear Magnetic Resonance (NMR) permits the noninvasive measurement of blood flow signals unimpaired by clothes, bandages, casts, etc. The cylindrical crossed-coil NMR blood flowmeter was used to measure blood flow through a cross-section of the human forearm. Two calibration procedures are described: one for pulsati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594989

    authors: Salles-Cunha SX,Halbach RE,Battocletti JH,Sances A Jr

    更新日期:1981-07-01 00:00:00

  • Effective and equivalent organ doses in patients undergoing coronary angiography and percutaneous coronary intervention.

    abstract:PURPOSE:Recent recommendations of the International Commission on Radiological Protection state that the use of effective dose (E) for assessing patient exposure has severe limitations, though it can be kept for dose comparisons. In cardiology procedures, the equivalent dose (H(T)) is one of the most appropriate dose q...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3561508

    authors: Compagnone G,Ortolani P,Domenichelli S,Ovi V,Califano G,Dall'Ara G,Marzocchi A

    更新日期:2011-04-01 00:00:00

  • Reduction of motion blurring artifacts using respiratory gated CT in sinogram space: a quantitative evaluation.

    abstract::Techniques have been developed for reducing motion blurring artifacts by using respiratory gated computed tomography (CT) in sinogram space and quantitatively evaluating the artifact reduction. A synthetic sinogram was built from multiple scans intercepting a respiratory gating window. A gated CT image was then recons...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2074187

    authors: Lu W,Parikh PJ,Hubenschmidt JP,Politte DG,Whiting BR,Bradley JD,Mutic S,Low DA

    更新日期:2005-11-01 00:00:00

  • SU-E-J-192: Static Breath-Hold MRI Based Measurement of Change in Pulmonary Function Following a Course of Radiation Therapy.

    abstract:PURPOSE:Radiation Therapy (RT) induced pulmonary function change may depend on the location, underlying function of that lung prior to radiations, radiation dose/fractionation and other factors. We propose to evaluate the radiation induced pulmonary function change using static breath-hold MRI scans with vascular infor...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735033

    authors: Ding K,Cao K,Du K,Chen Q,Ennis D,Christensen G,Reinhardt J,Libby B,Benedict S,Sheng K

    更新日期:2012-06-01 00:00:00

  • Novel scintillation detector design and performance for proton radiography and computed tomography.

    abstract:PURPOSE:Proton computed tomography (pCT) will enable accurate prediction of proton and ion range in a patient while providing the benefit of lower radiation exposure than in x-ray CT. The accuracy of the range prediction is essential for treatment planning in proton or ion therapy and depends upon the detector used to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4939255

    authors: Bashkirov VA,Schulte RW,Hurley RF,Johnson RP,Sadrozinski HF,Zatserklyaniy A,Plautz T,Giacometti V

    更新日期:2016-02-01 00:00:00

  • Sci-Fri AM: Imaging - 04: SPECT-based functional lung imaging in the prediction of radiation pneumonitis: A retrospective clinical and dosimetric correlation.

    abstract:PURPOSE:To investigate whether functionally-weighted dose-volume histogram (DVH) parameters are more predictive of radiation-induced pneumonitis (RP) than standard parameters such as V20 and mean lung dose (MLD). MATERIALS AND METHODS:A retrospective chart review identified 26 patients who received curative-intent rad...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740190

    authors: Hoover D,Reid RH,Rodrigues G,Wong E,Stitt L,Yaremko BP

    更新日期:2012-07-01 00:00:00

  • Efficient implementations of a pseudodynamical stochastic filtering strategy for static elastography.

    abstract::A computationally efficient pseudodynamical filtering setup is established for elasticity imaging (i.e., reconstruction of shear modulus distribution) in soft-tissue organs given statically recorded and partially measured displacement data. Unlike a regularized quasi-Newton method (QNM) that needs inversion of ill-con...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3158808

    authors: Banerjee B,Roy D,Vasu RM

    更新日期:2009-08-01 00:00:00

  • Validation of OSLD and a treatment planning system for surface dose determination in IMRT treatments.

    abstract:PURPOSE:To evaluate the accuracy of skin dose determination for composite multibeam 3D conformal radiation therapy (3DCRT) and intensity modulated radiation therapy (IMRT) treatments using optically stimulated luminescent dosimeters (OSLDs) and Eclipse treatment planning system. METHODS:Surface doses measured by OSLDs...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4890795

    authors: Zhuang AH,Olch AJ

    更新日期:2014-08-01 00:00:00

  • FRoG: An independent dose and LETd prediction tool for proton therapy at ProBeam® facilities.

    abstract:PURPOSE:Particle therapy is becoming increasingly available world-wide for precise tumor targeting, its favorable depth dose deposition, and increased biological damage to tumor tissue compared to conventional photon therapy. As demand increases for improved robustness and conformality, next-generation secondary dose c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14417

    authors: Kopp B,Fuglsang Jensen M,Mein S,Hoffmann L,Nyström H,Falk M,Haberer T,Abdollahi A,Debus J,Mairani A

    更新日期:2020-10-01 00:00:00

  • Unequal weighting of given doses in opposed fields in treatment of cancer of the tonsillar region using 60Co, 4-, 8-, 15-, 24-MVp photons.

    abstract::Weighting of given doses from parallel opposed fields is a widespread practice in radiation therapy of cancer in the tonsillar region. In order to determine when weighting is useful, dose distributions on the central axis were calculated for various energies (60Co, 4-, 8-, 15-, and MVp photons), weighting factors, and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594276

    authors: Wollin M,Gilbert HA,Kagan AR

    更新日期:1976-03-01 00:00:00

  • Experimental test of theoretical models for time-resolved reflectance.

    abstract::Four different expressions, derived from the diffusion theory or the random walk model, were used to fit time-resolved reflectance data for the evaluation of tissue optical properties. The experimental reflectance curves were obtained from phantoms of known optical parameters (absorption and transport scattering coeff...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597739

    authors: Cubeddu R,Pifferi A,Taroni P,Torricelli A,Valentini G

    更新日期:1996-09-01 00:00:00

  • A fast, noniterative approach for accelerated high-temporal resolution cine-CMR using dynamically interleaved streak removal in the power-spectral encoded domain with low-pass filtering (DISPEL) and modulo-prime spokes (MoPS).

    abstract:PURPOSE:To introduce a pair of accelerated non-Cartesian acquisition principles that when combined, exploit the periodicity of k-space acquisition, and thereby enable acquisition of high-temporal cine Cardiac Magnetic Resonance (CMR). METHODS:The mathematical formulation of a noniterative, undersampled non-Cartesian c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12234

    authors: Kawaji K,Patel MB,Cantrell CG,Tanaka A,Marino M,Tamura S,Wang H,Wang Y,Carroll TJ,Ota T,Patel AR

    更新日期:2017-07-01 00:00:00

  • Temporal and spectral imaging with micro-CT.

    abstract:PURPOSE:Micro-CT is widely used for small animal imaging in preclinical studies of cardiopulmonary disease, but further development is needed to improve spatial resolution, temporal resolution, and material contrast. We present a technique for visualizing the changing distribution of iodine in the cardiac cycle with du...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736809

    authors: Johnston SM,Johnson GA,Badea CT

    更新日期:2012-08-01 00:00:00

  • Development of a silicon diode detector for skin dosimetry in radiotherapy.

    abstract:PURPOSE:The aim of in vivo skin dosimetry was to measure the absorbed dose to the skin during radiotherapy, when treatment planning calculations cannot be relied on. It is of particularly importance in hypo-fractionated stereotactic modalities, where excessive dose can lead to severe skin toxicity. Currently, commercia...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12469

    authors: Vicoroski N,Espinoza A,Duncan M,Oborn BM,Carolan M,Metcalfe P,Menichelli D,Perevertaylo VL,Lerch MLF,Rosenfeld AB,Petasecca M

    更新日期:2017-10-01 00:00:00

  • Characteristic performance evaluation of a photon counting Si strip detector for low dose spectral breast CT imaging.

    abstract:PURPOSE:The possible clinical applications which can be performed using a newly developed detector depend on the detector's characteristic performance in a number of metrics including the dynamic range, resolution, uniformity, and stability. The authors have evaluated a prototype energy resolved fast photon counting x-...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4892174

    authors: Cho HM,Barber WC,Ding H,Iwanczyk JS,Molloi S

    更新日期:2014-09-01 00:00:00

  • A novel PET tumor delineation method based on adaptive region-growing and dual-front active contours.

    abstract::To more accurately and precisely delineate a tumor in a 3D PET image, we proposed a novel, semi-automatic, two-stage method by utilizing an adaptive region-growing algorithm and a dual-front active contour model. First, a rough region of interest (ROI) is manually drawn by a radiation oncologist that encloses a tumor....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2956713

    authors: Li H,Thorstad WL,Biehl KJ,Laforest R,Su Y,Shoghi KI,Donnelly ED,Low DA,Lu W

    更新日期:2008-08-01 00:00:00

  • Noninvasive cardiac arrhythmia ablation with particle beams.

    abstract::Cardiac arrhythmias are a major health burden, associated with reduced quality of life and substantial morbidity and mortality. Current therapy includes moderately effective medication and catheter-based ablation of arrhythmogenic substrates in the heart. Catheter interventions frequently have to be repeated due to re...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1002/mp.12595

    authors: Graeff C,Bert C

    更新日期:2018-11-01 00:00:00

  • Portal dose image (PDI) prediction for dosimetric treatment verification in radiotherapy. I. An algorithm for open beams.

    abstract::A method is presented for calculation of transmission functions for high energy photon beams through patients. These functions are being used in our clinic for prediction of portal dose images (PDIs) which are compared with PDIs measured with an electronic portal imaging device (EPID). The calculations are based on th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598293

    authors: Pasma KL,Heijmen BJ,Kroonwijk M,Visser AG

    更新日期:1998-06-01 00:00:00