Abstract:
:In this paper, a unified framework of iterative algebraic reconstruction for emission computed tomography (ECT) and its application to positron emission tomography (PET) is presented. The unified framework is based on an algebraic image restoration model and contains conventional iterative algebraic reconstruction algorithms: ART, SIRT, Landweber iteration (LWB), the generalized Landweber iteration (GLWB), the steepest descent method (STP), as well as iterative filtered backprojection (IFBP) reconstruction algorithms: Chang's method, Walters' method, and a modified iterative MAP. The framework provides an effective tool to systematically study conventional iterative algebraic algorithms and IFBP algorithms. Based on this framework, conventional iterative algebraic algorithms and IFBP algorithms are generalized. It is shown from the algebraic point of view that IFBP algorithms are not only excellent methods for correction of attenuation (either uniform or nonuniform) but are also good general iterative reconstruction algorithms (they can be applied to either attenuated or attenuation-free projections and converge very fast). The convergence behavior of iterative algebraic algorithms is discussed and insight is drawn into the fast convergence property of IFBP algorithms. A simulated PET system is used to evaluate IFBP algorithms and LWB in comparison with the maximum likelihood estimation via expectation maximization algorithm (MLE-EM) and the filtered backprojection (FBP) algorithm. The simulation results indicate that for both attenuation-free projection and attenuated projection cases IFBP algorithms have a significant computational advantage over LWB and MLE-EM, and have performance advantages over FBP in terms of contrast recovery and/or noise-to-signal ratios (NSRs) in regions of interest.
journal_name
Med Physjournal_title
Medical physicsauthors
Xu XL,Liow JS,Strother SCdoi
10.1118/1.596954subject
Has Abstractpub_date
1993-11-01 00:00:00pages
1675-84issue
6eissn
0094-2405issn
2473-4209journal_volume
20pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::Heat therapies such as hyperthermia and thermoablation are very promising approaches in the treatment of cancer. Compared with available hyperthermia modalities, magnetic fluid hyperthermia (MFH) yields better results in uniform heating of the deeply situated tumors. In this approach, fluid consisting of superparamagn...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3106343
更新日期:2009-05-01 00:00:00
abstract::Because of the high energy of the treatment beam, contrast of portal verification films is very poor. A simple contrast enhancement technique is described which we have labeled selective histogram equalization (SHE), to improve visualization of double-exposure portal images and this facilitate the beam verification pr...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597085
更新日期:1993-01-01 00:00:00
abstract::In external beam radiotherapy, electronic portal imaging becomes more and more an indispensable tool for the verification of the patient setup. For the safe clinical introduction of high dose conformal radiotherapy like intensity modulated radiation therapy, on-line patient setup verification is a prerequisite to ensu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1668391
更新日期:2004-04-01 00:00:00
abstract:PURPOSE:High-intensity focused ultrasound (HIFU) has been investigated for ablative therapy and drug enhancement for gene therapy and chemotherapy. The aim of this work is to explore the feasibility of pulsed focused ultrasound (pFUS) for cancer therapy using an in vivo animal model. METHODS:A clinical HIFU system (In...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4901352
更新日期:2014-12-01 00:00:00
abstract::While simple, intravascular brachytherapy (IVB) presents a considerable potential for harm to the patient. The medical physicist maintains the responsibility to minimize the likelihood of operational problems or dosimetric errors. The principals for safe operation remain the same as with any radiotherapy treatment: to...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1524167
更新日期:2002-12-01 00:00:00
abstract:PURPOSE:It is estimated that 7% of women in the western world will develop palpable breast cysts in their lifetime. Even though cysts have been correlated with risk of developing breast cancer, many of them are benign and do not require follow-up. We develop a method to discriminate benign solitary cysts from malignant...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12110
更新日期:2017-03-01 00:00:00
abstract:PURPOSE:Liver segmentation is an important prerequisite for the assessment of liver cancer treatment options like tumor resection, image-guided radiation therapy (IGRT), radiofrequency ablation, etc. The purpose of this work was to evaluate a new approach for liver segmentation. METHODS:A graph cuts segmentation metho...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3682171
更新日期:2012-03-01 00:00:00
abstract::Magnetic beam scanning allows one to spread proton beam over the desired radiation field area, improving beam utilization and conformity to the target area. This article discusses generic scan forms for generating uniform circular and rectangular fields and establishes criteria that can be applied to optimize selected...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3158731
更新日期:2009-08-01 00:00:00
abstract:PURPOSE:The aim of this study is to understand the characteristics of secondary electrons generated from the interaction of gold nanoparticles (GNPs) with x-rays as a function of nanoparticle size and beam energy and thereby further the understanding of GNP-enhanced radiotherapy. METHODS:The effective range, deflectio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3539623
更新日期:2011-02-01 00:00:00
abstract::Monte Carlo (MC) techniques can be used to build a simulation model of an electron accelerator to calculate output factors for electron fields. This can be useful during commissioning of electron beams from a linac and in clinical practice where irregular fields are also encountered. The Monte Carlo code BEAM/EGS4 was...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1373402
更新日期:2001-06-01 00:00:00
abstract:PURPOSE:To demonstrate the feasibility of compressed sensing (CS) to accelerate the acquisition of hyperpolarized (HP) 129 Xe multi-b diffusion MRI for quantitative assessments of lung microstructural morphometry. METHODS:Six healthy subjects and six chronic obstructive pulmonary disease (COPD) subjects underwent HP 1...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12944
更新日期:2018-07-01 00:00:00
abstract::Permanent implants of 125I seeds at Memorial Sloan-Kettering Cancer Center are performed by the method of "dimension averaging" to determine the total activity to be implanted; that is, the activity (in mCi) is taken to be five times the average dimension (in cm) of the target region. A nomograph has recently been dev...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594269
更新日期:1976-01-01 00:00:00
abstract::Our purpose in this work is to demonstrate that the efficiency of dose-rate computations in 125I brachytherapy, using multigroup discrete ordinates radiation transport simulations, can be significantly enhanced using broad energy group cross sections without a loss of accuracy. To this end, the DANTSYS multigroup disc...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1429238
更新日期:2002-02-01 00:00:00
abstract:PURPOSE:The authors have developed a quantitative calibration method for a multileaf collimator (MLC) which measures individual leaf positions relative to the MLC backup jaw on an Elekta Synergy linear accelerator. METHODS:The method utilizes a commercially available two-axis detector array (Profiler 2; Sun Nuclear Co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3218767
更新日期:2009-10-01 00:00:00
abstract::Results of a human observer performance study using a new ultrasound contrast-detail (CD) phantom are reported. The new phantom allows estimates of the fundamental statistical uncertainties involved in CD analysis. Results of these experiments show that observers generally considered to be "trained" require experience...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597147
更新日期:1993-01-01 00:00:00
abstract::In x-ray spectral measurement using a semiconductor detector system, accurate positioning of the detector in front of the anode is very important. This needs accurate determination of the focal spot position on the target in an x-ray tube. We present a simple technique to determine the focal spot position accurately. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597122
更新日期:1993-07-01 00:00:00
abstract::This study compared air exposures during conventional dental and maxillofacial radiography and similar views using free-focus radiography with conventional image receptors. The results show that periapical type surveys on nonscreen film placed extraorally or in the buccal fold may be carried out with an exposure to th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594690
更新日期:1980-07-01 00:00:00
abstract:PURPOSE:The performance of a newly developed, high resolution, microangiographic fluoroscope (MAF) (35 μm pixel pitch and 300 μm thick CsI phosphor) was evaluated using a generalized linear system analysis and compared with that of a standard amorphous Si thin film transistor flat panel detector (FPD) (194 μm pixel pit...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4792460
更新日期:2013-03-01 00:00:00
abstract:PURPOSE:To describe Acuros® CTS, a new software tool for rapidly and accurately estimating scatter in x-ray projection images by deterministically solving the linear Boltzmann transport equation (LBTE). METHODS:The LBTE describes the behavior of particles as they interact with an object across spatial, energy, and dir...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12850
更新日期:2018-05-01 00:00:00
abstract::A combination of Monte Carlo, convolution, and experimental techniques have been used to investigate bremsstrahlung production at 50 MeV in full-range targets to produce narrow elementary photon beams for scanning. Calculations using the ITS 3.0 Monte Carlo system for various target designs, including particle transpo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597681
更新日期:1996-04-01 00:00:00
abstract::A method is described for calibration of 192Ir high-dose-rate (HDR) brachytherapy afterloading systems. Since NIST does not offer calibration of ionization chambers with the gamma-ray spectrum of iridium-192, an interpolation procedure is employed, using calibrations above (137Cs, 662 keV) and below (250 kVcp, 146-keV...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596649
更新日期:1991-05-01 00:00:00
abstract::A new type of radiographic film, EDR (extended dose range) film, has been recently become available for film dosimetry. It is particularly attractive for composite isodose verification of intensity modulated radiation therapy because of its low sensitivity relative to the more common Kodak XV film. For XV film, the re...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1568979
更新日期:2003-05-01 00:00:00
abstract::Rotational angiography (RA) gantries are used routinely to acquire sequences of projection images of patients from which 3D renderings of vascular structures are generated using Feldkamp cone-beam reconstruction algorithms. However, these systems have limited resolution (<4 lp/mm). Micro-computed tomography (micro-CT)...
journal_title:Medical physics
pub_type: 信件
doi:10.1118/1.2989989
更新日期:2008-10-01 00:00:00
abstract:PURPOSE:The authors have developed a system that monitors intrafractional target motion perpendicular to the treatment beam with the aid of radioopaque markers by means of separating kV image and megavoltage (MV) treatment field on a single flat-panel detector. METHODS:They equipped a research Siemens Artiste linear a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3665712
更新日期:2012-01-01 00:00:00
abstract::Photon point dose kernels and absorbed fractions were generated in water for the full photon emission spectrum of each radionuclide of interest in nuclear medicine, by simulating the transport of particles using Monte Carlo. The kernels were then fitted to a mathematical expression. Absorbed fractions for point source...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597670
更新日期:1996-05-01 00:00:00
abstract:PURPOSE:Primary goal of this study is to select optimal registration schemes in the framework of interstitial lung disease (ILD) follow-up analysis in CT. METHODS:A set of 128 multiresolution schemes composed of multiresolution nonrigid and combinations of rigid and nonrigid registration schemes are evaluated, utilizi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4923170
更新日期:2015-08-01 00:00:00
abstract::Stereotactic Body Radiation Therapy (SBRT) is being increasingly used in the radiation oncology community to treat tumors in extra-cranial sites such as spine, lung, liver, pancreas and prostate. There are well established RTOG protocols (e.g. RTOG 0631 for spine, RTOG 0813 and 0915 for lung and RTOG 0438 for liver) t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4736142
更新日期:2012-06-01 00:00:00
abstract::We present a theoretical development and experimental verification of a description of power loss and sample resistance for a lossy sample in a nuclear magnetic resonance radio frequency coil for a sample geometry where the eddy current streamlines are disrupted from their usually assumed circular paths. Specifically ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596336
更新日期:1989-09-01 00:00:00
abstract:PURPOSE:Efficient and accurate segmentations of 3D end-firing transrectal ultrasound (TRUS) images play an important role in planning of 3D TRUS guided prostate biopsy. However, poor image quality of the input 3D TRUS images, such as strong imaging artifacts and speckles, often makes it a challenging task to extract th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4906129
更新日期:2015-02-01 00:00:00
abstract:PURPOSE:It is very important for calculation of clinical indices and diagnosis to detect thyroid nodules from ultrasound images. However, this task is a challenge mainly due to heterogeneous thyroid nodules with distinct components are similar to background in ultrasound images. In this study, we employ cascade deep co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12134
更新日期:2017-05-01 00:00:00