Abstract:
:Magnetic beam scanning allows one to spread proton beam over the desired radiation field area, improving beam utilization and conformity to the target area. This article discusses generic scan forms for generating uniform circular and rectangular fields and establishes criteria that can be applied to optimize selected scan patterns. During construction of the Midwest Proton Radiotherapy Institute (MPRI), Indiana University developed a magnetically scanned beam spreading system for the 3 m long gantry nozzle. Based on the commissioning experience, criteria for optimizing the scan patterns were derived. A numerical integration model was used to perform initial optimization of the resulting dose distribution. The selected scan patterns were then experimentally validated via test irradiation of Gafchromic films. Generic spiral and linear scan forms are proposed capable of delivering uniform circular and rectangular fields in continuous scanning mode. The test irradiations performed indicate that dose uniformity is within +/- 3% for both scan forms and that penumbra of the uncollimated field can approach the radius of the pristine beam spot. A well designed uniform scanning system can have a large library of uniform circular and rectangular fields of different sizes, which would increase beam utilization and minimize out-of-field dose to the patient.
journal_name
Med Physjournal_title
Medical physicsauthors
Anferov VAdoi
10.1118/1.3158731subject
Has Abstractpub_date
2009-08-01 00:00:00pages
3560-7issue
8eissn
0094-2405issn
2473-4209journal_volume
36pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::Complementary metal-oxide-semiconductors (CMOS) active pixel sensors can be optically coupled to CsI:Tl phosphors forming a indirect active pixel flat panel imager (APFPI) for high performance medical imaging. The aim of this work is to determine the x-ray imaging capabilities of CMOS-based APFPI and study the signal ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3036117
更新日期:2009-01-01 00:00:00
abstract::For the case of eye tumor therapy with protons, improvements are introduced compared to the standard dose calculation which implies straight-line optics and the constant-density assumption for the eye and its surrounding. The progress consists of (i) taking account of the lateral scattering of the protons in tissue by...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2168067
更新日期:2006-03-01 00:00:00
abstract:PURPOSE:Modulated electron radiation therapy (MERT) can offer significant advantages for breast treatments over conventional radiotherapy in terms of sparing distal critical structures. While intensity modulated radiation therapy (IMRT) has the advantage of achieving better dose homogeneity inside the target combining ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735665
更新日期:2012-06-01 00:00:00
abstract::The synchronization of dynamic multileaf collimator (DMLC) response with respiratory motion is critical to ensure the accuracy of DMLC-based four dimensional (4D) radiation delivery. In practice, however, a finite time delay (response time) between the acquisition of tumor position and multileaf collimator response ne...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1915017
更新日期:2005-06-01 00:00:00
abstract::The Anisotropic Analytical Algorithm (AAA) of the Varian Eclipse treatment planning system calculates absolute dose for a variety of beam settings including those with an enhanced dynamic wedge (EDW). This algorithm has gone through a number of version updates since it was first released in July 2005. Previous version...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2965929
更新日期:2008-07-01 00:00:00
abstract::The aim of the current study was to (a) provide normalized dose data for the estimation of the radiation dose from upper gastrointestinal tract contrast (UGIC) studies carried out to infants and (b) estimate the average patient dose and risks associated with radiation from UGIC examinations performed in our institutio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2181297
更新日期:2006-04-01 00:00:00
abstract::Breast density, the percentage of glandular breast tissue, has been identified as an important yet underutilized risk factor in the development of breast cancer. A quantitative method to measure breast density with dual energy imaging was investigated using a computer simulation model. Two configurations to measure br...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3002308
更新日期:2008-12-01 00:00:00
abstract:PURPOSE:The purpose of this study was to describe and evaluate methods for calculating a megavoltage computed tomography (MVCT)-derived MR hardware attenuation map (μ-map) and dual-energy CT (DECT) for 511 keV photons. METHODS:Phantom measurements were acquired on a whole-body hybrid PET/MRI system, using a four-chann...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12407
更新日期:2017-09-01 00:00:00
abstract::Monte Carlo dose calculations will potentially reduce systematic errors that may be present in currently used dose calculation algorithms. However, Monte Carlo calculations inherently contain random errors, or statistical uncertainty, the level of which decreases inversely with the square root of computation time. Our...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598916
更新日期:2000-03-01 00:00:00
abstract:PURPOSE:To compare organ specific cancer incidence risks for standard and complex external beam radiotherapy (including cone beam CT verification) following breast conservation surgery for early breast cancer. METHOD:Doses from breast radiotherapy and kilovoltage cone beam CT (CBCT) exposures were obtained from thermo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4748332
更新日期:2012-10-01 00:00:00
abstract::An important aspect of dual-energy (DE) x-ray image decomposition is the incorporation of noise reduction techniques to mitigate the amplification of quantum noise. This article extends cascaded systems analysis of imaging performance to DE imaging systems incorporating linear noise reduction algorithms. A general ana...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2826556
更新日期:2008-02-01 00:00:00
abstract:PURPOSE:To reduce the potential of late toxicity (tissue necrosis and cognitive function loss) from brain radiotherapy, we studied a novel planning technique for MLC-equipped linear accelerators (LINACS) that reduces the high doses delivered outside the PTV, enhancing radiation dose conformity. METHODS:The feasibility...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735656
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The authors had previously published measurements of the detectability of disk-shaped contrast objects in images obtained from a C-arm CT system. A simple approach based on Rose's criterion was used to scale the date, assuming the threshold for the smallest diameter detected should be inversely proportional to ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3397465
更新日期:2010-05-01 00:00:00
abstract::A method is developed to smooth intensity-modulated beam delivery while considering hardware constraints. The method uses matrix algebra to model MLC leaf motion and hardware constraints such as interleaf digitization, synchronization requirements, and intersegment field abutment to deliver intensity modulated beam se...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1521121
更新日期:2002-12-01 00:00:00
abstract::The feasibility of using film dosimetry data as the input data for patient treatment planning was evaluated. The central-axis depth dose and the off-axis ratios obtained from film measurements in a solid phantom were compared with those of ion-chamber measurements in water. Two techniques were used to generate isodose...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596409
更新日期:1989-11-01 00:00:00
abstract:PURPOSE:Periodic MV∕KV radiographs taken during volumetric modulated arc therapy (VMAT) for hypofractionated treatment provide guidance in intrafractional motion management. The choice of imaging frequency and timing are key components in delivering the desired dose while reducing associated overhead such as imaging do...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4742846
更新日期:2012-09-01 00:00:00
abstract::Reported MOSFET measurements concern mostly external radiotherapy and in vivo dosimetry. In this paper, we apply the technique for absolute dosimetry in the context of HDR brachytherapy using an 192Ir source. Measured radial dose rate distributions in water for different planes perpendicular to the source axis are pre...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2198168
更新日期:2006-06-01 00:00:00
abstract:PURPOSE:Design and optimization of medical imaging systems benefit from accurate theoretical modeling that identifies the physical factors governing image quality, particularly in the early stages of system development. This work extends Fourier metrics of imaging performance and detectability index (d') to tomosynthes...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3560428
更新日期:2011-04-01 00:00:00
abstract:PURPOSE:Formation of new blood vessels (angiogenesis) in response to hypoxia is a fundamental event in the process of tumor growth and metastatic dissemination. However, abnormalities in tumor neovasculature often induce increased interstitial pressure (IP) and further reduce oxygenation (pO2) of tumor cells. In radiot...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3615164
更新日期:2011-08-01 00:00:00
abstract:PURPOSE:We have developed a robust tool for performing volumetric and temporal analysis of nodules from respiratory gated four-dimensional (4D) CT. The method could prove useful in IMRT of lung cancer. METHODS:We modified the conventional graph-cuts method by adding an adaptive shape prior as well as motion informatio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12690
更新日期:2018-01-01 00:00:00
abstract::Many problems in physics involve imaging objects with high spatial frequency content in a limited amount of time. The limitation of available experimental data leads to the infamous problem of diffraction limited data which manifests itself by causing ringing in the image. This ringing is due to the interference pheno...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596427
更新日期:1989-05-01 00:00:00
abstract:PURPOSE:The biologically effective dose (BED) of temporary brachytherapy treatments is a function of both chosen radionuclide (R) and implant duration (T). This study endeavored to evaluate BED delivered to the tumor volume and surrounding ocular structures as a function of plaque position (P), prescription dose, R, an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735548
更新日期:2012-06-01 00:00:00
abstract::Molecular imaging is the direct or indirect noninvasive monitoring and recording of the spatial and temporal distribution of in vivo molecular, genetic, and/or cellular processes for biochemical, biological, diagnostic, or therapeutic applications. Molecular images that indicate the presence of malignancy can be acqui...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.4819818
更新日期:2013-10-01 00:00:00
abstract::A new radiographic patient positioning technique developed for radiosurgery has been analyzed to show the effect of computed tomography (CT) slice thickness on the precision of target localization during treatment. The positioning technique establishes the pose of the patient's anatomy during treatment by comparing tr...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598500
更新日期:1999-02-01 00:00:00
abstract::A general expression is derived for the NMR signal from a fluid undergoing random directional flow such as encountered within the microcirculation. The dependence of the echo amplitude on flow velocity, sample morphology, and experimental parameters are described in terms of a temporal velocity autocorrelation functio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597170
更新日期:1994-04-01 00:00:00
abstract:PURPOSE:Photoacoustic imaging has proven to be able to detect vascularization-driven optical absorption contrast associated with tumors. In order to detect breast tumors located a few centimeter deep in tissue, a sensitive ultrasound detector is of crucial importance for photoacoustic mammography. Further, because the ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4792462
更新日期:2013-03-01 00:00:00
abstract:PURPOSE:In 3D gradient echo magnetic resonance imaging (MRI), strong field gradients B0macro are visually observed at air/tissue interfaces. At low spatial resolution in particular, the respective field gradients lead to an apparent increase in intravoxel dephasing, and subsequently, to signal loss or inaccurate R2* es...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12318
更新日期:2017-07-01 00:00:00
abstract::Accurate dosimetry of small-field photon beams tends to be difficult to perform due to the presence of lateral electronic disequilibrium and steep dose gradients. In stereotactic radiosurgery (SRS), small fields of 6-30 mm in diameter are used. Generally thermoluminescence dosimetry chips, Farmer, Thimble ion chamber,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1350437
更新日期:2001-03-01 00:00:00
abstract::Three-dimensional water phantoms are routinely used when acquiring the data necessary to commission medical linear accelerators. A new water phantom controller has been developed at our institution that is unique in several aspects. The water phantom controller is based on an IBM XT compatible computer. This has been ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596414
更新日期:1989-01-01 00:00:00
abstract:PURPOSE:To develop a deformable mapping technique to match corresponding lesions between digital breast tomosynthesis (DBT) and automated breast ultrasound (ABUS) images. METHODS:External fiducial markers were attached to the surface of two CIRS multi-modality compressible breast phantoms (A and B) containing multiple...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13113
更新日期:2018-10-01 00:00:00