Abstract:
PURPOSE:Modulated electron radiation therapy (MERT) can offer significant advantages for breast treatments over conventional radiotherapy in terms of sparing distal critical structures. While intensity modulated radiation therapy (IMRT) has the advantage of achieving better dose homogeneity inside the target combining both MERT and IMRT will be the ideal scenario. The Aim of the present study is to investigate the possibility of further improving breast radiation therapy using combined MERT/IMRT treatment technique. METHODS:Accurate modeling of a prototype motorized electron multileaf collimator was verified in a separate study. In this work treatment planning was performed by an in house Monte Carlo based inverse planning system. Dose deposition coefficients were calculated using MCPLAN and utilizing real patients CTs. Optimization is then conducted based on an equivalent uniform dose objective function. MERT and IMRT plans were created for different patients. RESULTS:The clinical beneficial outcome for MERT either alone or combined with IMRT was investigated based on isodose distributions and dose volume histograms. It is shown that MERT can give similar dose distributions as IMRT in some cases. For some cases, MERT could be advantageous whenever more skin dose was required. In some cases MERT can be identified as the best option. It was found that MERT compared to IMRT could introduce hot spots inside the target. However this was resolved in combined MERT/IMRT treatment. Dose uniformity can be restored with a reduction in the maximum lung and heart received dose. CONCLUSION:MERT can improve treatment plan quality for many breast patients. In some cases better results can be obtained with a combined MERT/IMRT treatment, where a homogeneous dose in the target can be achieved with an improvement in the DVH of critical structures. This work has been supported by a UICC American Cancer Society Beginning Investigators Fellowship funded by the American Cancer Society.
journal_name
Med Physjournal_title
Medical physicsauthors
Eldib A,Li J,Jin L,Ma Cdoi
10.1118/1.4735665subject
Has Abstractpub_date
2012-06-01 00:00:00pages
3838issue
6Part19eissn
0094-2405issn
2473-4209journal_volume
39pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:Ultrasound-induced mild hyperthermia has advantages for noninvasive, localized and controlled drug delivery. In this study, a tissue-mimicking agarose-based phantom with a thermally sensitive indicator was developed for studying the spatial drug delivery profile using ultrasound-induced mild hyperthermia. METH...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4813299
更新日期:2013-08-01 00:00:00
abstract::The immediate goal of clinically based x-ray-transmission computed tomography (CT) is to provide a measurement of the x-ray linear attenuation coefficient in cross section with the ultimate goal of impacting on patient management and care. To do this with the accuracy needed for clinical goals requires the careful int...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.594381
更新日期:1977-03-01 00:00:00
abstract::Preclinical experiments are carried out with approximately 20-30 microm wide, approximately 10 mm high parallel microbeams of hard, broad-"white"-spectrum x rays (approximately 50-600 keV) to investigate microbeam radiation therapy (MRT) of brain tumors in infants for whom other kinds of radiotherapy are inadequate an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1562169
更新日期:2003-04-01 00:00:00
abstract:PURPOSE:To evaluate dependence of measured dose on size and location of region of interest (ROI) in Gafchromic EBT3 film dosimetry. METHODS:Gafchromic EBT3 films were irradiated perpendicularly using the 6MV beam from a linear accelerator at 10 cm depth (100 cm SSD) of a 30 × 30 × 20 cm3 solid water phantom for a rang...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12885
更新日期:2018-05-01 00:00:00
abstract::A spread-out Bragg peak (SOBP) is used in proton beam therapy to create a longitudinal conformality of the required dose to the target. In order to create this effect in a passive beam scattering system, a variety of components must operate in conjunction to produce the desired beam parameters. We will describe how th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2776255
更新日期:2007-10-01 00:00:00
abstract::This article is the first in a series on the calculation of electron dose using multiple-scattering theory. In it we develop a unified theory, which we term Gaussian multiple-scattering theory, starting from a number of contributions already in the literature: the Fermi-Eyges multiple-scattering theory, the Yang path ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596166
更新日期:1988-03-01 00:00:00
abstract::Computed tomography is sensitive to changes in the imaged distribution during acquisition of the projection data. Previous investigations have emphasized discrete or discontinuous changes in the imaged object. Recent advances have motivated our investigation of object time-dependence characterized by a continuous func...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594458
更新日期:1978-11-01 00:00:00
abstract::The ability of Leksell GammaPlan to perform stereotactic space localizations with image sets where there is misalignment of the patient's head (stereotactic frame and fiducial apparatus) relative to the computed tomography (CT) scanner coordinate system was studied. Misalignment is sometimes necessary for patient comf...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2179751
更新日期:2006-04-01 00:00:00
abstract:PURPOSE:Respiratory gating in PET is an approach used to minimize the negative effects of respiratory motion on spatial resolution. It is based on an initial determination of a patient's respiratory movements during a scan, typically using hardware based systems. In recent years, several fully automated databased algor...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3483784
更新日期:2010-10-01 00:00:00
abstract::The calibration (in rad/nC) of an air-filled tissue-equivalent ionization chamber for neutrons of 15-MeV average energy was determined by measuring absolute fluences and calculating the kerma per unit fluence. The neutron calibration determined from the gamma-ray calibration and application of the Bragg-Gray relation ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594310
更新日期:1977-03-01 00:00:00
abstract::Imaging parameters associated with a clinical magnetic resonance imaging (MRI) system, evaluated with the use of simple and inexpensive phantoms, are described in evaluation of a clinical MRI system. Images, obtained with a Diasonics 0.35-T MRI system using an elliptical whole-body radio frequency coil, are presented ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595894
更新日期:1986-07-01 00:00:00
abstract:PURPOSE:The measurement of malignant pleural mesothelioma is critical to the assessment of tumor response to therapy. Current response assessment standards utilize summed linear measurements acquired on three computed tomography (CT) sections. The purpose of this study was to evaluate manual area measurements as an alt...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4810940
更新日期:2013-08-01 00:00:00
abstract::The use of magnetic resonance imaging as a readout method for polymer gel dosimetry commonly involves long imaging sessions, particularly when high spatial resolution is required in all three dimensions, for the investigation of dose distributions with steep dose gradients and stringent dose delivery specifications. I...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2065367
更新日期:2005-11-01 00:00:00
abstract:PURPOSE:A dosimetric system formed by Gafchromic EBT2 radiochromic film and Epson Expression 10000XL flatbed scanner was commissioned for dosimetry. In this paper, several open questions concerning the commissioning of radiochromic films for dosimetry were addressed: (a) is it possible to employ this dosimetric system ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4772075
更新日期:2013-01-01 00:00:00
abstract:PURPOSE:A compact, three-tesla magnetic resonance imaging (MRI) system has been developed. It features a 37 cm patient aperture, allowing the use of commercial receiver coils. Its design allows simultaneously for gradient amplitudes of 85 millitesla per meter (mT/m) sustained and 700 tesla per meter per second (T/m/s) ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4941362
更新日期:2016-03-01 00:00:00
abstract:PURPOSE:The efficiency of radioembolization procedures could be greatly enhanced if results of the 99m Tc-MAA pretreatment procedure were immediately available in the interventional suite, enabling 1-day procedures as a result of direct estimation of the hepatic radiation dose and lung shunt fraction. This would, howev...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13253
更新日期:2019-01-01 00:00:00
abstract::Two experimental methods are described for obtaining average energies of neutron spectra produced by an electron accelerator in a medical treatment room. In the first method, the dose equivalent is measured by means of indium activation foils in an Andersson-Braun moderator. Fluences are determined by the usual activa...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595662
更新日期:1985-11-01 00:00:00
abstract::Proton beams offer several advantages over conventional radiation techniques for treating cancer and other diseases. These advantages might be negated if the leakage and scatter radiation from the beamline and patient are too large. Although the leakage and scatter radiation for the double scattering proton beamlines ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2805086
更新日期:2008-01-01 00:00:00
abstract::Heating rate (HR) patterns in cylindrical structures were studied with inhomogeneous limb phantoms. These phantoms, arm and thigh models consisting of fat, bone, and muscle material, were heated with Clini-Therm L, M, and MS applicators at 915 MHz. The thigh model is 18 cm in diameter with 2.65-cm-thick fat on the out...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596627
更新日期:1991-11-01 00:00:00
abstract:PURPOSE:Breast magnetic resonance imaging is highly sensitive but not very specific for the detection of breast cancer. Opportunities exist to supplement the image acquisition with a more specific modality provided the technical challenges of meeting space limitations inside the bore, restricted breast access, and elec...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4820361
更新日期:2013-10-01 00:00:00
abstract::A water beam imaging system (WBIS) has been developed and used to verify dose distributions for intensity modulated radiotherapy using dynamic multileaf collimator. This system consisted of a water container, a scintillator screen, a charge-coupled device camera, and a portable personal computer. The scintillation ima...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1413519
更新日期:2001-12-01 00:00:00
abstract::Neutron energy spectra and spectra of dose deposition in tissue-equivalent material have been measured for neutron sources produced by 16-, 22-, 35-, and 45.5-MeV deuterons and 22.5-, 35-, 45-, and 65.5-MeV protons incident upon a thick beryllium target. Neutron spectra were measured using time-of-flight techniques an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594392
更新日期:1977-05-01 00:00:00
abstract::An important aspect of the intensity modulated radiotherapy (IMRT) process is that of optimizing the beam intensity profiles. Most such methods use a comparison between the defined dose distribution (including prescription dose and dose limits for critical structures) and the current distribution. The comparison may i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1428756
更新日期:2002-01-01 00:00:00
abstract:PURPOSE:As radiation therapy evolves toward more adaptive techniques, image guidance plays an increasingly important role, not only in patient setup but also in monitoring the delivered dose and adapting the treatment to patient changes. This study aimed to validate a method for evaluation of delivered intensity modula...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4903292
更新日期:2015-01-01 00:00:00
abstract::This paper is concerned with the proposed Birmingham accelerator-based epithermal neutron beam for boron neutron capture therapy (BNCT). In particular, the option of producing a therapy beam at an orthogonal direction to the incoming protons is considered. Monte Carlo radiation transport simulations, both with and wit...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598479
更新日期:1999-01-01 00:00:00
abstract::An indirect flat-panel imager (FPI) with avalanche gain is being investigated for low-dose x-ray imaging. It is made by optically coupling a structured x-ray scintillator CsI(Tl) to an amorphous selenium (a-Se) avalanche photoconductor called HARP (high-gain avalanche rushing photoconductor). The final electronic imag...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2008428
更新日期:2005-09-01 00:00:00
abstract::Extensive information has been made available relative to the physical aspects necessary for calculation of radiation absorbed dose from radiopharmaceuticals. A similar data base for the biological factors involved in these calculations has not been documented as thoroughly. The authors present an extensive literature...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594679
更新日期:1980-05-01 00:00:00
abstract:PURPOSE:The purpose of this study was to provide updated radiation dose from diagnostic exams performed for pregnant patients suspected of pulmonary embolism (PE) using the recently developed BREP phantoms of pregnant woman and the fetus. Also to challenge the validity of current recommendations suggest that ventilatio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12558
更新日期:2017-11-01 00:00:00
abstract:PURPOSE:The aim of this study was to use MRI gel dosimetry to determine the dose profile of 50kV MAGNUM® X-ray tube, MOXTEK Inc., in order to calibrate small solid dosimeters of alanine, tooth enamel and LiF-TLDs, commonly used in clinical quality assurance and datation dosimetry. METHODS:MAGIC-f polymer gel was kept ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735203
更新日期:2012-06-01 00:00:00
abstract::Treatment of cervical cancer often involves intracavitary high dose rate (HDR) brachytherapy. Dose delivered to the bladder and rectum are typically estimated using the ICRU reference points. Dose to the sigmoid and small bowel are not estimated, yet these organs typically exhibit significant complication rates. The o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2965957
更新日期:2008-07-01 00:00:00