Abstract:
:Neutron energy spectra and spectra of dose deposition in tissue-equivalent material have been measured for neutron sources produced by 16-, 22-, 35-, and 45.5-MeV deuterons and 22.5-, 35-, 45-, and 65.5-MeV protons incident upon a thick beryllium target. Neutron spectra were measured using time-of-flight techniques and the dose distribution was measured using a 1/2 in. spherical "tissue-equivalent" proportional counter filled with "tissue-equivalent" gas.
journal_name
Med Physjournal_title
Medical physicsauthors
Heintz PH,Johnsen SW,Peek NFdoi
10.1118/1.594392subject
Has Abstractpub_date
1977-05-01 00:00:00pages
250-4issue
3eissn
0094-2405issn
2473-4209journal_volume
4pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:A dynamic bowtie filter can modulate flux along both fan and view angles for reduced patient dose, scatter, and required photon flux, which is especially important for photon counting detectors (PCDs). Among the proposed dynamic bowtie designs, the piecewise-linear attenuator (Hsieh and Pelc, Med Phys. 2013;40:...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13272
更新日期:2019-01-01 00:00:00
abstract:PURPOSE:Breast magnetic resonance imaging is highly sensitive but not very specific for the detection of breast cancer. Opportunities exist to supplement the image acquisition with a more specific modality provided the technical challenges of meeting space limitations inside the bore, restricted breast access, and elec...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4820361
更新日期:2013-10-01 00:00:00
abstract::In this paper, the consistency of kilovoltage (tube potentials between 40 and 300 kV) x-ray beam dosimetry using the "in-air" method and the in-phantom measurement has been studied. The procedures for the measurement of the central-axis depth-dose curve, which serve as a link between the dose at the reference depth to...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598448
更新日期:1998-12-01 00:00:00
abstract:PURPOSE:Bone strength is the key factor impacting fracture risk. Assessment of bone strength from high-resolution (HR) images have largely relied on linear micro-finite element analysis (μFEA) even though failure always occurs beyond the yield point, which is outside the linear regime. Nonlinear μFEA may therefore be m...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4802085
更新日期:2013-05-01 00:00:00
abstract::Over the past decade, computed tomography (CT) theory, techniques and applications have undergone a rapid development. Since CT is so practical and useful, undoubtedly CT technology will continue advancing biomedical and non-biomedical applications. In this outlook article, we share our opinions on the research and de...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.2836950
更新日期:2008-03-01 00:00:00
abstract::The purposes of this research are to investigate the effectiveness of our novel image features for segmentation of anatomic regions such as the lungs and the mediastinum in chest radiographs and to develop an automatic computerized method for image processing. A total of 85 screening chest radiographs from Johns Hopki...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598277
更新日期:1998-06-01 00:00:00
abstract:PURPOSE:Calculations of deoxyribonucleic acid (DNA) damages involve many parameters in the computation process. As these parameters are often subject to uncertainties, it is of central importance to comprehensively quantify their impacts on DNA single-strand break (SSB) and double-strand break (DSB) yields. This has be...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14036
更新日期:2020-04-01 00:00:00
abstract::Electronic portal imaging devices (EPIDs) are mainly used for patient setup verification during treatment but other geometric properties like block shape and leaf positions are also determined. Electronic portal dosimetry allows dosimetric treatment verification. By combining geometric and dosimetric information, the ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1640972
更新日期:2004-02-01 00:00:00
abstract:PURPOSE:Mega-voltage cone-beam CT (MVCBCT) imaging can be used to monitor changes in neck flexion and calculate the true spinal cord dose during radiotherapy. To sum the dose over multiple fractions and compare with the planned dose requires deformable image registration. This study investigates the accuracy of deforma...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734919
更新日期:2012-06-01 00:00:00
abstract::Weighting of given doses from parallel opposed fields is a widespread practice in radiation therapy of cancer in the tonsillar region. In order to determine when weighting is useful, dose distributions on the central axis were calculated for various energies (60Co, 4-, 8-, 15-, and MVp photons), weighting factors, and...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594276
更新日期:1976-03-01 00:00:00
abstract:PURPOSE:To quantitatively characterize the interfractional anatomic variations in post-operative radiation therapy (RT) for prostate bed, so that appropriate strategy that can fully address these variations can be developed. METHODS:A total of 102 daily pre-treatment CT acquired using an in-room CT (CTVision, Siemens)...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734844
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The authors investigated the performance of a recently introduced 160-mm/256-row CT system for low dose quantitative myocardial perfusion (MP) imaging of the whole heart. This platform is equipped with a gantry capable of rotating at 280 ms per full cycle, a second generation of adaptive statistical iterative r...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4957389
更新日期:2016-08-01 00:00:00
abstract::Currently, patients with brain neoplasms must undergo both computed tomography (CT) and magnetic resonance (MR) imaging to take advantage of CT's density information and MR's soft tissue imaging capabilities. A method has been developed that allows virtual simulation, digitally reconstructed radiographs (DRRs), and 3-...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598382
更新日期:1998-10-01 00:00:00
abstract::In the case of non-small cell lung cancer, doses typically prescribed (60-66 Gy) are not sufficient to ensure a satisfactory tumor control probability. Dose escalation needs to be realized, but dose to organs at risk (OARs) must be kept under widely accepted clinical thresholds. Also, lung functionality is not homogen...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2965976
更新日期:2008-07-01 00:00:00
abstract::Neutron cross sections for nonelastic and elastic reactions on a range of elements have been evaluated for incident energies up to 150 MeV. These cross sections agree well with experimental cross section data for charged-particle production as well as neutron and photon production. Therefore they can be used to determ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598601
更新日期:1999-06-01 00:00:00
abstract::The photon spectra in vacuum around four types of 192Ir HDR brachytherapy sources are calculated using the Monte Carlo code EGS4 and the most recent spectral information on 192Ir decay. The air-kerma strengths per unit activity are calculated based on the photon fluence around a bare 192Ir source and around each of fo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598763
更新日期:1999-11-01 00:00:00
abstract::Model-based deformable organ registration techniques using the finite element method (FEM) have recently been investigated intensively and applied to image-guided adaptive radiotherapy (IGART). These techniques assume that human organs are linearly elastic material, and their mechanical properties are predetermined. U...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2163838
更新日期:2006-02-01 00:00:00
abstract:PURPOSE:Target localization accuracy of cone-beam CT (CBCT) images used in radiation treatment of respiratory disease sites is affected by motion artifacts (blurring and streaking). The authors have previously reported on a method of respiratory motion correction in thoracic CBCT at end expiration (EE). The previous re...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4896101
更新日期:2014-10-01 00:00:00
abstract::We studied a recently proposed aggregated CT reconstruction technique which combines the complementary advantages of kilovoltage (kV) and megavoltage (MV) x-ray imaging. Various phantoms were imaged to study the effects of beam orientations and geometry of the imaging object on image quality of reconstructed CT. It wa...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2768862
更新日期:2007-09-01 00:00:00
abstract::When treating prostate cancer using high dose rate (HDR) brachytherapy, overdosing the rectal wall may lead to post-treatment rectal complications. An area of concern is related to how the rectal wall dose is calculated by treatment planning systems (TPSs). TPSs are used to calculate the dose delivered to the rectal w...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3031111
更新日期:2009-01-01 00:00:00
abstract::Single photon emission computed tomography (SPECT) is an important technology for molecular imaging studies of small animals. In this arena, there is an increasing demand for high performance imaging systems that offer improved spatial resolution and detection efficiency. We have designed a multipinhole small animal i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2190332
更新日期:2006-05-01 00:00:00
abstract:PURPOSE:To show that Cherenkov emission is generated by external radiotherapy beam in tissue, and could serve as optical source to excite an oxygen sensitive phosphor, Oxyphor G4, within tissue. The intensity and lifetime of the phosphorescence was measured with a time-gated system and reveals the oxygenation levels in...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734811
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Onboard imaging-currently performed primarily by x-ray transmission modalities-is essential in modern radiation therapy. As radiation therapy moves toward personalized medicine, molecular imaging, which views individual gene expression, may also be important onboard. Nuclear medicine methods, such as single pho...
journal_title:Medical physics
pub_type: 信件
doi:10.1118/1.4845195
更新日期:2014-01-01 00:00:00
abstract::A computer dose model for a low energy gamma-emitting stent in a heterogeneous medium is described. The method is based on the Sievert model which is adapted to the dose-point-kernel (DPK) model to compute the dose distribution about filtered gamma sources (Sievert-DPK model). The new gamma stent model can take into a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1380214
更新日期:2001-07-01 00:00:00
abstract:PURPOSE:To use EGSnrc Monte Carlo simulations for magnetic field dosimetry to determine optimal measurement orientations, calculate beam quality conversion factors for 32 cylindrical and three parallel-plate (PP) ion chambers, evaluate the beam quality and angular dependence of these factors, and examine the magnetic f...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12716
更新日期:2018-02-01 00:00:00
abstract:PURPOSE:Dedicated breast PET/CT is expected to have utility in local staging, surgical planning, monitoring of therapy response, and detection of residual disease for breast cancer. Quantitative metrics will be integral to several such applications. The authors present a validation of fully 3D data correction schemes f...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3703593
更新日期:2012-05-01 00:00:00
abstract:PURPOSE:To validate GPUMCD, a new package for fast Monte Carlo dose calculations based on the GPU (graphics processing unit), as a tool for low-energy single seed brachytherapy dosimetry for specific seed models. As the currently accepted method of dose calculation in low-energy brachytherapy computations relies on sev...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3598441
更新日期:2011-07-01 00:00:00
abstract::Traditionally, short scan helical FDK algorithms have been implemented based on horizontal transaxial slices. However, not every point on the horizontal transaxial slice satisfies Tuy's condition for the corresponding (pi+fan angle) segment of helix, which means that some points on the horizontal slices are incomplete...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1916077
更新日期:2005-06-01 00:00:00
abstract:PURPOSE:The appearance of parenchymal∕stromal patterns in mammography have been characterized as having a Wiener power spectrum with an inverse power-law shape described by the exponential parameter, β. The amount of fibroglandular tissue, which can be quantified in terms of volumetric breast density (VBD), influences ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4736422
更新日期:2012-08-01 00:00:00
abstract::The calibration (in rad/nC) of an air-filled tissue-equivalent ionization chamber for neutrons of 15-MeV average energy was determined by measuring absolute fluences and calculating the kerma per unit fluence. The neutron calibration determined from the gamma-ray calibration and application of the Bragg-Gray relation ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594310
更新日期:1977-03-01 00:00:00