The effect of rectal heterogeneity on wall dose in high dose rate brachytherapy.

Abstract:

:When treating prostate cancer using high dose rate (HDR) brachytherapy, overdosing the rectal wall may lead to post-treatment rectal complications. An area of concern is related to how the rectal wall dose is calculated by treatment planning systems (TPSs). TPSs are used to calculate the dose delivered to the rectal wall, but they assume that the rectum is a water-equivalent homogeneous medium of infinite size and do not consider the effect that an air-filled "empty" rectal cavity would have on the dose absorbed along the rectal wall. The aim of this research is to quantify the effect that an air cavity has on the rectal wall dose, as its presence changes the backscatter conditions in the region. The MO Skin and RADFET dosimeters proved capable of measuring absolute dose with increasing distance from the HDR Ir-192 brachytherapy source. However, the anterior rectal wall doses measured by the MOSkin and RADFET in an empty rectal cavity were 14.7 +/- 0.2% and 13.7 +/- 0.6% lower than the dose measured in a homogeneous rectal phantom. Monte Carlo simulations corroborated the experimentally obtained results, reporting a -13.2 +/- 0.6% difference. The dose measured at the posterior wall of an empty rectal cavity was between 22% and 26% greater than the dose measured in a full rectal cavity. The heterogeneity of the rectal volume appears to have a significant effect on the rectal dose when compared to calculated rectal dose.

journal_name

Med Phys

journal_title

Medical physics

authors

Kwan IS,Wilkinson D,Cutajar D,Lerch M,Rosenfeld A,Howie A,Bucci J,Chin Y,Perevertaylo VL

doi

10.1118/1.3031111

subject

Has Abstract

pub_date

2009-01-01 00:00:00

pages

224-32

issue

1

eissn

0094-2405

issn

2473-4209

journal_volume

36

pub_type

杂志文章
  • First clinical implementation of real-time, real anatomy tracking and radiation beam control.

    abstract:PURPOSE:We describe the acceptance testing, commissioning, periodic quality assurance, and workflow procedures developed for the first clinically implemented magnetic resonance imaging-guided radiation therapy (MR-IGRT) system for real-time tracking and beam control. METHODS:The system utilizes real-time cine imaging ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13002

    authors: Green OL,Rankine LJ,Cai B,Curcuru A,Kashani R,Rodriguez V,Li HH,Parikh PJ,Robinson CG,Olsen JR,Mutic S,Goddu SM,Santanam L

    更新日期:2018-05-28 00:00:00

  • Evaluating the impact of extended field-of-view CT reconstructions on CT values and dosimetric accuracy for radiation therapy.

    abstract:PURPOSE:Wide bore CT scanners use extended field-of-view (eFOV) reconstruction algorithms to attempt to recreate tissue truncated due to large patient habitus. Radiation therapy planning systems rely on accurate CT numbers in order to correctly plan and calculate radiation dose. This study looks at the impact of eFOV r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13299

    authors: Cheung JP,Shugard E,Mistry N,Pouliot J,Chen J

    更新日期:2019-02-01 00:00:00

  • Approximate 3D iterative reconstruction for SPECT.

    abstract::Compared with slice-by-slice approaches for SPECT reconstruction, three-dimensional iterative methods provide a more accurate physical model and an improved SPECT image. Clinical application of these methods, however, is limited primarily to their computational demands. This paper investigates the methods for approxim...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598030

    authors: Gilland DR,Jaszczak RJ,Riauka TA,Coleman RE

    更新日期:1997-09-01 00:00:00

  • SU-E-T-476: GPU-Based Monte Carlo Radiotherapy Dose Calculation Using Phase- Space Sources.

    abstract:PURPOSE:To design an efficient method for utilizing phase-space source models in the GPU-based Monte Carlo (MC) dose calculation engine gDPM. METHODS:In GPU-based MC algorithms, particles are transported in parallel on different threads. Particles of different types and energies can require significantly different exe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735565

    authors: Townson R,Jia X,Zavgorodni S,Jiang S

    更新日期:2012-06-01 00:00:00

  • Scatter-glare correction using a convolution algorithm with variable weighting.

    abstract::Several investigators have approximated the scatter component of digital radiographic images by applying a constant weighting factor to a convolved version of the detected image. The scatter approximation is then subtracted from the detected image. When a constant weighting factor is used, the scatter in areas of low ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596088

    authors: Naimuddin S,Hasegawa B,Mistretta CA

    更新日期:1987-05-01 00:00:00

  • Dosimetric characteristics of Novalis shaped beam surgery unit.

    abstract::The dosimetric characteristics of a new dedicated radiosurgical treatment unit are systematically measured in terms of its percent depth dose, beam profile, and relative scatter factor. High-resolution diode detector, mini-ion-chamber detector, and conventional Kodak XV films are used to measure dosimetric data for a ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1494830

    authors: Yin FF,Zhu J,Yan H,Gaun H,Hammoud R,Ryu S,Kim JH

    更新日期:2002-08-01 00:00:00

  • Poster - Thurs Eve-31: Clinical implementation and experience with EPID-based precision isocentre localization.

    abstract::Modern linear accelerators contain multiple isocentres, defined by the mechanical motions of gantry, collimator and table. Isocentre localization for these motions has been performed using film and manual evaluations which have difficulty in relating the individual motions. To address these limitations, we have develo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965950

    authors: Heaton R,Smale J,Norrlinger B,Wang Y,van Prooijen M,Islam M

    更新日期:2008-07-01 00:00:00

  • Thermal regulation of tightly packed solid-state photodetectors in a 1 mm(3) resolution clinical PET system.

    abstract:PURPOSE:Silicon photodetectors are of significant interest for use in positron emission tomography (PET) systems due to their compact size, insensitivity to magnetic fields, and high quantum efficiency. However, one of their main disadvantages is fluctuations in temperature cause strong shifts in gain of the devices. P...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4903889

    authors: Freese DL,Vandenbroucke A,Innes D,Lau FW,Hsu DF,Reynolds PD,Levin CS

    更新日期:2015-01-01 00:00:00

  • Three-dimensional dose reconstruction of breast cancer treatment using portal imaging.

    abstract::In this study, we present an algorithm for three-dimensional (3-D) dose reconstruction using portal images obtained with an electronic portal imaging device (EPID). For this purpose an algorithm for 2-D dose reconstruction, which was previously developed in our institution, was adapted. The external contour of the pat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1589496

    authors: Louwe RJ,Damen EM,van Herk M,Minken AW,Törzsök O,Mijnheer BJ

    更新日期:2003-09-01 00:00:00

  • A statistical analysis of ionometrically measured 6-MV x-ray beam parameters.

    abstract::A statistical analysis has been made of ionometrically measured parameters related to the central-axis output, the beam symmetry, the beam flatness, and the depth dose for the 6-MV x-ray beam from the Therac-6 linear accelerator. The means and coefficients of variation of the measurements are determined on a monthly b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595642

    authors: Dawson DJ,Gribble MA

    更新日期:1984-09-01 00:00:00

  • Air core detectors for Cerenkov-free scintillation dosimetry of brachytherapy β-sources.

    abstract:PURPOSE:Plastic scintillation detectors are used for dosimetry in small radiation fields with high dose gradients, e.g., provided by β-emitting sources like 106 Ru/106 Rh eye plaques. A drawback is a background signal caused by Cerenkov radiation generated by electrons passing the optical fibers (light guides) of this ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12374

    authors: Eichmann M,Thomann B

    更新日期:2017-09-01 00:00:00

  • A method for physically based radiotherapy optimization with intelligent tissue weight determination.

    abstract::An important aspect of the intensity modulated radiotherapy (IMRT) process is that of optimizing the beam intensity profiles. Most such methods use a comparison between the defined dose distribution (including prescription dose and dose limits for critical structures) and the current distribution. The comparison may i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1428756

    authors: Jones L,Hoban P

    更新日期:2002-01-01 00:00:00

  • Upgrade and benchmarking of a 4D treatment planning system for scanned ion beam therapy.

    abstract:PURPOSE:Upgrade and benchmarking of a research 4D treatment planning system (4DTPS) suitable for realistic patient treatment planning and treatment simulations taking into account specific requirements for scanned ion beam therapy, i.e., modeling of dose heterogeneities due to interplay effects and range changes caused...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4800802

    authors: Richter D,Schwarzkopf A,Trautmann J,Krämer M,Durante M,Jäkel O,Bert C

    更新日期:2013-05-01 00:00:00

  • Projection-domain scatter correction for cone beam computed tomography using a residual convolutional neural network.

    abstract:PURPOSE:Scatter is a major factor degrading the image quality of cone beam computed tomography (CBCT). Conventional scatter correction strategies require handcrafted analytical models with ad hoc assumptions, which often leads to less accurate scatter removal. This study aims to develop an effective scatter correction ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13583

    authors: Nomura Y,Xu Q,Shirato H,Shimizu S,Xing L

    更新日期:2019-07-01 00:00:00

  • Comparisons of treatment optimization directly incorporating systematic patient setup uncertainty with a margin-based approach.

    abstract:PURPOSE:To develop a probabilistic treatment planning (PTP) method which is robust to systematic patient setup errors and to compare PTP plans with plans generated using a planning target volume (PTV) margin optimized to give the same target coverage probability as the PTP plan. METHODS:Plans adhering to the RTOG-0126...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3679856

    authors: Moore JA,Gordon JJ,Anscher M,Silva J,Siebers JV

    更新日期:2012-02-01 00:00:00

  • Response of an implantable MOSFET dosimeter to 192Ir HDR radiation.

    abstract::New in vivo dosimetry methods would be useful for clinical HDR brachytherapy. An implantable MOSFET Dose Verification System designed by Sicel Technologies, Inc. was examined for use with 192Ir HDR applications. This investigation demonstrated that varying the dose rate from 22 to 84 cGy/min did not change detector re...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3013574

    authors: Fagerstrom JM,Micka JA,DeWerd LA

    更新日期:2008-12-01 00:00:00

  • Design and performance of a compact and stationary microSPECT system.

    abstract:PURPOSE:Over the last ten years, there has been an extensive growth in the development of microSPECT imagers. Most of the systems are based on the combination of conventional, relatively large gamma cameras with poor intrinsic spatial resolution and multipinhole collimators working in large magnification mode. Spatial ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4822621

    authors: Van Holen R,Vandeghinste B,Deprez K,Vandenberghe S

    更新日期:2013-11-01 00:00:00

  • Task Group 284 Report: Magnetic Resonance Imaging Simulation in Radiotherapy: Considerations for Clinical Implementation, Optimization, and Quality Assurance.

    abstract::The use of dedicated magnetic resonance simulation (MR-SIM) platforms in Radiation Oncology has expanded rapidly, introducing new equipment and functionality with the overall goal of improving the accuracy of radiation treatment planning. However, this emerging technology presents a new set of challenges that need to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14695

    authors: Glide-Hurst CK,Paulson ES,McGee K,Tyagi N,Hu Y,Balter J,Bayouth J

    更新日期:2021-01-01 00:00:00

  • The effect of pitch in multislice spiral/helical CT.

    abstract::The purpose of this study is to understand the effect of pitch on raw data interpolation in multislice spiral/helical computed tomography (CT) and provide guidelines for scanner design and protocol optimization. Multislice spiral CT is mainly characterized by the three parameters: the number of detector arrays, the de...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598804

    authors: Wang G,Vannier MW

    更新日期:1999-12-01 00:00:00

  • On the assay of brachytherapy sources.

    abstract::In many of brachytherapy procedures, a large amount of radioactive sources are used to deliver desired doses to the target volume. It is both the federal regulation recommendation (U.S. Nuclear Regulatory Commission, 10 CFR 35.432) and recommendations of the American Association of Physicists in Medicine (AAPM) [Kutch...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2734723

    authors: Yue NJ,Haffty BG,Yue J

    更新日期:2007-06-01 00:00:00

  • Effects of constant frequency noise in magnetic resonance imaging with nonuniform k-space sampling.

    abstract::Magnetic resonance images can be compromised by constant frequency (CF) noise, such as radio frequency (RF) noise. We investigate the effects of CF noise in four imaging methods with non-uniform k-space sampling: single-shot echo-planar imaging (EPI) with sinusoidal readout gradients, phase-encoded echo-planar spectro...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1496096

    authors: Du W,Karczmar GS,Pan X

    更新日期:2002-08-01 00:00:00

  • Contrast-detail analysis of image degradation due to lossy compression.

    abstract::A contrast-detail (CD) experiment was performed to study the effect of lossy compression on computed radiographic (CR) images. Digital CR images of a phantom were compressed by quantizing the full-frame discrete cosine transform and Huffman encoding the result. Since low-contrast detectability is directly linked to an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597489

    authors: Cook LT,Insana MF,McFadden MA,Hall TJ,Cox GG

    更新日期:1995-06-01 00:00:00

  • Comparison of transperineal ultrasound image guidance technique to transabdominal technique for prostate radiation therapy.

    abstract:INTRODUCTION:Ultrasound (US) guidance of the prostate has long been conducted using a transabdominal (TA) approach. More recently, a transperineal (TP) approach has been made available for image guidance. Our aim was to determine if both methods produced similar alignments within the same patients. MATERIALS AND METHO...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14522

    authors: Szegedi M,Boehm C,Paxton A,Rassiah-Szegedi P,Sarkar V,Zhao H,Su F,Kokeny KE,Lloyd S,Tward J,Salter BJ

    更新日期:2020-12-01 00:00:00

  • Evaluation of delivered monitor unit accuracy of gated step-and-shoot IMRT using a two-dimensional detector array.

    abstract:PURPOSE:To overcome the problem of organ motion in intensity-modulated radiation therapy (IMRT), gated IMRT is often used for the treatment of lung cancer. In this study, the authors investigated the accuracy of the delivered monitor units (MUs) from each segment during gated IMRT using a two-dimensional detector array...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3310806

    authors: Cheong KH,Kang SK,Lee M,Kim SS,Park S,Hwang TJ,Kim KJ,Oh DH,Bae H,Suh TS

    更新日期:2010-03-01 00:00:00

  • Radiation dose reduction using a CdZnTe-based computed tomography system: comparison to flat-panel detectors.

    abstract:PURPOSE:Although x-ray projection mammography has been very effective in early detection of breast cancer, its utility is reduced in the detection of small lesions that are occult or in dense breasts. One drawback is that the inherent superposition of parenchymal structures makes visualization of small lesions difficul...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3312435

    authors: Le Huy Q,Ducote JL,Molloi S

    更新日期:2010-03-01 00:00:00

  • An inexpensive kVp penetrameter.

    abstract::In this report we describe an improvement upon the design by Stanton and Lightfoot for a simple photographic null method to determine the kVp of a diagnostic region x-ray source. The new version has two primary advantages over the Ardran and Crooks design in that it is both simpler and less expensive to produce. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595716

    authors: Netto TG,Cameron JR

    更新日期:1985-03-01 00:00:00

  • Reverse mapping of normal tissue complication probabilities onto dose volume histogram space: the problem of randomness of the dose volume histogram sampling.

    abstract::A very important issue in contemporary inverse treatment radiotherapy planning is the specification of proper dose-volume constraints limiting the treatment planning algorithm from delivering high doses to the normal tissue surrounding the tumor. Recently we have proposed a method called reverse mapping of normal tiss...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2198307

    authors: Markov K,Schinkel C,Stavreva N,Stavrev P,Weldon M,Fallone BG

    更新日期:2006-09-01 00:00:00

  • Primary dose in photon beams with lateral electron disequilibrium.

    abstract::It is shown that in narrow monoenergetic photon beams under conditions of lateral electron disequilibrium, primary absorbed dose P(r) is a simple function of beam radius r: P(r) = P lambda.(1 - e(-gamma.r)), where P lambda is the primary dose in broad beams for which complete lateral electron equilibrium exists, and g...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596741

    authors: Nizin PS,Chang XS

    更新日期:1991-07-01 00:00:00

  • SU-C-218-06: Evaluation of a CT-Based, Semi-Automated Lung Mass Estimation Method Under Varying Acquisition Conditions.

    abstract:PURPOSE:To evaluate a simple, semi-automated lung mass estimation method on CT scans from a variety of acquisition techniques for mass correction of MIRD dose estimates. METHODS:CT scans from ten patients undergoing stereotactic body radiation therapy treatment planning on a GE DST PET/CT scanner were analyzed retrosp...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734654

    authors: Busse N,Erwin W,Pan T

    更新日期:2012-06-01 00:00:00

  • Feasibility of MRI-only treatment planning for proton therapy in brain and prostate cancers: Dose calculation accuracy in substitute CT images.

    abstract:PURPOSE:Magnetic resonance imaging (MRI) is increasingly used for radiotherapy target delineation, image guidance, and treatment response monitoring. Recent studies have shown that an entire external x-ray radiotherapy treatment planning (RTP) workflow for brain tumor or prostate cancer patients based only on MRI refer...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4958677

    authors: Koivula L,Wee L,Korhonen J

    更新日期:2016-08-01 00:00:00