A statistical analysis of ionometrically measured 6-MV x-ray beam parameters.

Abstract:

:A statistical analysis has been made of ionometrically measured parameters related to the central-axis output, the beam symmetry, the beam flatness, and the depth dose for the 6-MV x-ray beam from the Therac-6 linear accelerator. The means and coefficients of variation of the measurements are determined on a monthly basis for each parameter. Mean coefficients of variation less than +/- 1% have been determined and are useful in establishing the optimal limits of acceptance of these parameters. The results of this study indicate that the long-term stability of the radiation parameters associated with this unit can be maintained within acceptable limits with a consistent quality-assurance program.

journal_name

Med Phys

journal_title

Medical physics

authors

Dawson DJ,Gribble MA

doi

10.1118/1.595642

subject

Has Abstract

pub_date

1984-09-01 00:00:00

pages

708-11

issue

5

eissn

0094-2405

issn

2473-4209

journal_volume

11

pub_type

杂志文章
  • SU-E-I-32: Sterile Radiation Reduction Gloves May Be Contraindicated in Fluoroscopically Guided Interventions.

    abstract:PURPOSE:Sterile radiation reduction gloves have been widely used in the past decade to provide modest decreases in operator hand dose when the hands are placed in the field of view (FOV). While multiple publications have quantified the potential dose reduction from the use of such gloves, possible effects on the patien...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734747

    authors: Pasciak A,Neveu M,Sriharan A,Balius A,Jones A

    更新日期:2012-06-01 00:00:00

  • Characterization of a two-dimensional liquid-filled ion chamber detector array used for verification of the treatments in radiotherapy.

    abstract:PURPOSE:The purpose of the study is to investigate the characteristics of a two-dimensional (2D) liquid-filled ion chamber detector array, which is used for the verification of radiotherapy treatment plans that use small field sizes of up to 10 × 10 cm. METHODS:The device used in this study was Octavius 1000 SRS model...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4870439

    authors: Markovic M,Stathakis S,Mavroidis P,Jurkovic IA,Papanikolaou N

    更新日期:2014-05-01 00:00:00

  • SU-E-J-160: 4D Dynamic Arc of Non-Modulated Variable-Dose-Rate Fields for Lung SBRT: A Feasibility Study.

    abstract:PURPOSE:Conformal SBRT plans for Lung cancer with static gantry angles are ideal candidates for applying motion tracking because of: (1) better dosimetric conformity with reduced target margin and (2) easier and more faithful target tracking without intensity modulation. This work is to demonstrate that by delivering t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734998

    authors: Yi B,Yang X,Niu Y,Yu C

    更新日期:2012-06-01 00:00:00

  • Introducing gel dosimetry in a clinical environment: customization of polymer gel composition and magnetic resonance imaging parameters used for 3D dose verifications in radiosurgery and intensity modulated radiotherapy.

    abstract::Radiation sensitive gels have been used as dosimeters for clinical dose verification of different radiation therapy modalities. However, the use of gels is not widespread, because careful techniques are required to achieve the dose precision and accuracy aimed for in clinical dose verification. Here, the introduction ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2712042

    authors: Crescenti RA,Scheib SG,Schneider U,Gianolini S

    更新日期:2007-04-01 00:00:00

  • Radionuclide photon dose kernels for internal emitter dosimetry.

    abstract::Photon point dose kernels and absorbed fractions were generated in water for the full photon emission spectrum of each radionuclide of interest in nuclear medicine, by simulating the transport of particles using Monte Carlo. The kernels were then fitted to a mathematical expression. Absorbed fractions for point source...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597670

    authors: Furhang EE,Sgouros G,Chui CS

    更新日期:1996-05-01 00:00:00

  • SU-E-I-94: External Beam Radiation Cherenkov Emission in Tissue Used for Tissue Oxygen Sensing.

    abstract:PURPOSE:To show that Cherenkov emission is generated by external radiotherapy beam in tissue, and could serve as optical source to excite an oxygen sensitive phosphor, Oxyphor G4, within tissue. The intensity and lifetime of the phosphorescence was measured with a time-gated system and reveals the oxygenation levels in...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734811

    authors: Zhang R,Kanick S,Vinogradov S,Esipova T,Pogue B

    更新日期:2012-06-01 00:00:00

  • Measurements of the neutron yields from 7Li(p,n)7Be reaction (thick target) with incident energies from 1.885 to 2.0 MeV.

    abstract::Accelerator-based neutron source have been considered to be practical for boron neutron capture therapy (BNCT). Based on experience with a parameters of the Brookhaven National Laboratory BMRR reactor neutron source, which has been used in treatment experiments, the future accelerator-based neutron source for BNCT sho...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598299

    authors: Yu W,Yue G,Han X,Chen J,Tian B

    更新日期:1998-07-01 00:00:00

  • A simple magnetic spectrometer for radiotherapy electron beams.

    abstract::A small, lightweight, single-focusing magnetic spectrometer was designed, assembled, and tested for analysis of electron beams from radiotherapy electron linacs. The objective was to develop a low cost, simple device that could be easily replicated in other medical centers, and to demonstrate the practicality of indiv...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597271

    authors: Deasy JO,Almond PR,McEllistrem MT,Ross CK

    更新日期:1994-11-01 00:00:00

  • SU-E-I-41: Characterization of a Linear Fiber-Optic Coupled Dosimeter.

    abstract:PURPOSE:This study investigated the dosimetry performance of a linear fiber-optic coupled dosimeter with a sensitive element varying from 3 to 15 cm in length. The dosimeter is comprised of a tissue equivalent plastic scintillating fiber coupled to a photomultiplier tube (PMT). The sensitive element has a length repres...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734756

    authors: Hoerner M,Hintenlang D

    更新日期:2012-06-01 00:00:00

  • A method for avoiding overlap of left and right lungs in shape model guided segmentation of lungs in CT volumes.

    abstract:PURPOSE:The automated correct segmentation of left and right lungs is a nontrivial problem, because the tissue layer between both lungs can be quite thin. In the case of lung segmentation with left and right lung models, overlapping segmentations can occur. In this paper, the authors address this issue and propose a so...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4894817

    authors: Gill G,Bauer C,Beichel RR

    更新日期:2014-10-01 00:00:00

  • Poster - Thur Eve - 66: A planning comparison between RapidArc and intensity modulated radiotherapy for head and neck cancer.

    abstract::Volumetric modulated arc therapy (VMAT) has recently been used to improve the dose distribution and efficiency of treatment delivery over the standard intensity-modulated radiotherapy (IMRT) technique. This study compares the dosimetry between RapidArc plan and standard IMRT plan for head and neck cancer. Three head a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740174

    authors: Jiang R,Fleck A,Schaly B,Charland P,Zhan L,Alliet K,Rachakonda R,Osei E

    更新日期:2012-07-01 00:00:00

  • Photoelectric-enhanced radiation therapy with quasi-monochromatic computed tomography.

    abstract::Photoelectric-enhanced radiation therapy is a bimodal therapy, consisting of the administration of highly radiation-absorbing substances into the tumor area and localized regional irradiation with orthovoltage x-rays. Irradiation can be performed by a modified computed tomography (CT) unit equipped with an additional ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3125137

    authors: Jost G,Mensing T,Golfier S,Lawaczeck R,Pietsch H,Hütter J,Cibik L,Gerlach M,Krumrey M,Fratzscher D,Arkadiev V,Wedell R,Haschke M,Langhoff N,Wust P,Lüdemann L

    更新日期:2009-06-01 00:00:00

  • 2-Step IMAT and 2-Step IMRT: a geometrical approach.

    abstract::The purpose of this paper is to develop a method that reduces the number of segments for intensity modulated arc therapy (IMAT) and intensity modulated radiotherapy (IMRT) for concave target volumes (TV). The aim was to utilize no more than two intensity levels per organ at risk (OAR) and to derive both optimal segmen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1861161

    authors: Bratengeier K

    更新日期:2005-03-01 00:00:00

  • Parametrization of head-scatter factors for rectangular photon fields using an equivalent square formalism.

    abstract::Head-scatter factors of symmetric square and rectangular fields (field center on the central beam axis) defined by the upper (Y) and lower (X) jaws for 6 and 15 MV photon beams from 2300CD and 600C accelerators (Varian Associates, Inc., Palo Alto, CA) were measured, as well as those for fields shaped by the Y jaws and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597617

    authors: Yu MK,Murray B,Sloboda R

    更新日期:1995-08-01 00:00:00

  • Rotationally resliced 3D prostate TRUS segmentation using convex optimization with shape priors.

    abstract:PURPOSE:Efficient and accurate segmentations of 3D end-firing transrectal ultrasound (TRUS) images play an important role in planning of 3D TRUS guided prostate biopsy. However, poor image quality of the input 3D TRUS images, such as strong imaging artifacts and speckles, often makes it a challenging task to extract th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4906129

    authors: Qiu W,Yuan J,Ukwatta E,Fenster A

    更新日期:2015-02-01 00:00:00

  • An investigation of a new amorphous silicon electronic portal imaging device for transit dosimetry.

    abstract::The relationship between the pixel value and exit dose was investigated for a new commercially available amorphous silicon electronic portal imaging device. The pixel to dose mapping function was established to be linear for detector distances between 116.5 cm to 150 cm from the source, radiation field sizes from 5 x ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1508108

    authors: Grein EE,Lee R,Luchka K

    更新日期:2002-10-01 00:00:00

  • Completeness map evaluation demonstrated with candidate next-generation cardiac CT architectures.

    abstract:PURPOSE:In this report, the authors introduce the general concept of the completeness map, as a means to evaluate the completeness of data acquired by a given CT system design (architecture and scan mode). They illustrate the utility of completeness map by applying the completeness map concept to a number of candidate ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3700172

    authors: Liu B,Bennett J,Wang G,De Man B,Zeng K,Yin Z,Fitzgerald P,Yu H

    更新日期:2012-05-01 00:00:00

  • Validation and application of a fast Monte Carlo algorithm for assessing the clinical impact of approximations in analytical dose calculations for pencil beam scanning proton therapy.

    abstract:PURPOSE:Monte Carlo (MC) dose calculation is generally superior to analytical dose calculation (ADC) used in commercial TPS to model the dose distribution especially for heterogeneous sites, such as lung and head/neck patients. The purpose of this study was to provide a validated, fast, and open-source MC code, MCsquar...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13231

    authors: Huang S,Souris K,Li S,Kang M,Barragan Montero AM,Janssens G,Lin A,Garver E,Ainsley C,Taylor P,Xiao Y,Lin L

    更新日期:2018-12-01 00:00:00

  • A time-domain wavelet-based approach for fluorescence diffuse optical tomography.

    abstract:PURPOSE:In the context of fluorescence diffuse optical tomography, determining the optimal way to exploit the time-resolved information has been receiving much attention and different features of the time-resolved signals have been introduced. In this article, the authors revisit and generalize the notion of feature, c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3431571

    authors: Ducros N,Da Silva A,Dinten JM,Seelamantula CS,Unser M,Peyrin F

    更新日期:2010-06-01 00:00:00

  • Technical Note: Radiotherapy dose characterization of gel dosimetry using shear wave elasticity imaging.

    abstract:PURPOSE:Radiotherapy is an effective treatment for many types of cancer in clinical settings. Gel dosimetry has the potential to record three-dimensional (3D) dose distribution compared to a conventional ion chamber. As the elasticity of the gel is altered after irradiation due to gel polymerization, we aim to measure ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14020

    authors: Xie WH,Su CT,Kao YJ,Chang TH,Chang YJ,Yao CH,Hsieh BY

    更新日期:2020-03-01 00:00:00

  • The enhancement of radiotherapy verification images by an automated edge detection technique.

    abstract::Adaptive histogram equalization techniques are known to be effective for the enhancement of contrast in portal images acquired during radiotherapy treatments. A significant drawback is the loss of definition on the edges of the treatment field. Analysis of this problem shows that it can be remedied by separating the t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596807

    authors: Leszczynski KW,Shalev S,Cosby NS

    更新日期:1992-05-01 00:00:00

  • A novel approach to evaluate spatial resolution of MRI clinical images for optimization and standardization of breast screening protocols.

    abstract:PURPOSE:Stringent quality assurance is required in MRI breast screening to ensure that different scanners and imaging protocols reach similar diagnostic performance. The authors propose a methodology, based on power spectrum analysis (PSA), to evaluate spatial resolution in clinical images. To demonstrate this approach...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4966704

    authors: Borri M,Scurr ED,Richardson C,Usher M,Leach MO,Schmidt MA

    更新日期:2016-12-01 00:00:00

  • An improved bolus configuration for commercial multielement ultrasound and microwave hyperthermia systems.

    abstract::A simple modification is presented for two commercially available hyperthermia applicators which dramatically improves the regulation and dynamic control of the temperature at the bolus/tissue interface. This alteration requires the addition of a variable speed pump, bubble trap, simple heat exchanger, and a few minor...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597196

    authors: Diederich CJ,Stauffer PR,Bozzo D

    更新日期:1994-09-01 00:00:00

  • SU-E-T-535: Proton Dose Calculations in Homogeneous Media.

    abstract:PURPOSE:To develop a pencil beam dose calculation algorithm for scanned proton beams that improves modeling of scatter events. METHODS:Our pencil beam algorithm (PBA) was developed for calculating dose from monoenergetic, parallel proton beams in homogeneous media. Fermi-Eyges theory was implemented for pencil beam tr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735624

    authors: Chapman J,Fontenot J,Newhauser W,Hogstrom K

    更新日期:2012-06-01 00:00:00

  • Prostate brachytherapy seed localization by analysis of multiple projections: identifying and addressing the seed overlap problem.

    abstract::Intraoperative three-dimensional reconstruction of seed locations during prostate brachytherapy for purposes of immediate computation of radiation dosimetry is an active area of current investigation, including methods which use multiple fluoroscopic projections. A simulation study using seed locations extracted from ...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.1707740

    authors: Su Y,Davis BJ,Herman MG,Robb RA

    更新日期:2004-05-01 00:00:00

  • Technical Note: Immunohistochemical evaluation of mouse brain irradiation targeting accuracy with 3D-printed immobilization device.

    abstract:PURPOSE:Small animal immobilization devices facilitate positioning of animals for reproducible imaging and accurate focal radiation therapy. In this study, the authors demonstrate the use of three-dimensional (3D) printing technology to fabricate a custom-designed mouse head restraint. The authors evaluate the accuracy...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4933200

    authors: Zarghami N,Jensen MD,Talluri S,Foster PJ,Chambers AF,Dick FA,Wong E

    更新日期:2015-11-01 00:00:00

  • Assessment of the spectral performance of hybrid photon counting x-ray detectors.

    abstract:PURPOSE:Hybrid Photon Counting (HPC) detectors profoundly improved x-ray diffraction experiments at third generation synchrotron facilities. Enabling the simultaneous measurement of x-ray intensities in multiple energy bins, they also have many potential applications in the field of medical imaging. A prerequisite for ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12323

    authors: Trueb P,Zambon P,Broennimann C

    更新日期:2017-09-01 00:00:00

  • Robotic intrafractional US guidance for liver SABR: System design, beam avoidance, and clinical imaging.

    abstract:PURPOSE:To present a system for robotic 4D ultrasound (US) imaging concurrent with radiotherapy beam delivery and estimate the proportion of liver stereotactic ablative body radiotherapy (SABR) cases in which robotic US image guidance can be deployed without interfering with clinically used VMAT beam configurations. M...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4964454

    authors: Schlosser J,Gong RH,Bruder R,Schweikard A,Jang S,Henrie J,Kamaya A,Koong A,Chang DT,Hristov D

    更新日期:2016-11-01 00:00:00

  • Characterization of the nanoDot OSLD dosimeter in CT.

    abstract:PURPOSE:The extensive use of computed tomography (CT) in diagnostic procedures is accompanied by a growing need for more accurate and patient-specific dosimetry techniques. Optically stimulated luminescent dosimeters (OSLDs) offer a potential solution for patient-specific CT point-based surface dosimetry by measuring a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4914398

    authors: Scarboro SB,Cody D,Alvarez P,Followill D,Court L,Stingo FC,Zhang D,McNitt-Gray M,Kry SF

    更新日期:2015-04-01 00:00:00

  • An innovative digital imaging set-up allowing a low-dose approach to phase contrast applications in the medical field.

    abstract::Recently, new imaging modalities based on the detection of weak phase perturbations effects, among which are phase contrast and diffraction imaging, have been developed by several researchers. Due to their high sensitivity to weakly absorbing details, these techniques seem to be very promising for applications in the ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1388219

    authors: Olivo A,Arfelli F,Cantatore G,Longo R,Menk RH,Pani S,Prest M,Poropat P,Rigon L,Tromba G,Vallazza E,Castelli E

    更新日期:2001-08-01 00:00:00