Abstract:
PURPOSE:Small animal immobilization devices facilitate positioning of animals for reproducible imaging and accurate focal radiation therapy. In this study, the authors demonstrate the use of three-dimensional (3D) printing technology to fabricate a custom-designed mouse head restraint. The authors evaluate the accuracy of this device for the purpose of mouse brain irradiation. METHODS:A mouse head holder was designed for a microCT couch using cad software and printed in an acrylic based material. Ten mice received half-brain radiation while positioned in the 3D-printed head holder. Animal placement was achieved using on-board image guidance and computerized asymmetric collimators. To evaluate the precision of beam localization for half-brain irradiation, mice were sacrificed approximately 30 min after treatment and brain sections were stained for γ-H2AX, a marker for DNA breaks. The distance and angle of the γ-H2AX radiation beam border to longitudinal fissure were measured on histological samples. Animals were monitored for any possible trauma from the device. RESULTS:Visualization of the radiation beam on ex vivo brain sections with γ-H2AX immunohistochemical staining showed a sharp radiation field within the tissue. Measurements showed a mean irradiation targeting error of 0.14±0.09 mm (standard deviation). Rotation between the beam axis and mouse head was 1.2°±1.0° (standard deviation). The immobilization device was easily adjusted to accommodate different sizes of mice. No signs of trauma to the mice were observed from the use of tooth block and ear bars. CONCLUSIONS:The authors designed and built a novel 3D-printed mouse head holder with many desired features for accurate and reproducible radiation targeting. The 3D printing technology was found to be practical and economical for producing a small animal imaging and radiation restraint device and allows for customization for study specific needs.
journal_name
Med Physjournal_title
Medical physicsauthors
Zarghami N,Jensen MD,Talluri S,Foster PJ,Chambers AF,Dick FA,Wong Edoi
10.1118/1.4933200subject
Has Abstractpub_date
2015-11-01 00:00:00pages
6507-13issue
11eissn
0094-2405issn
2473-4209journal_volume
42pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:To reduce image noise and radiation dose in Digital Breast Tomosynthesis (DBT) reconstructions. METHODS:A retrospective study was performed on clinical data sets acquired at a normal dose with Hologic Selenia Dimensions DBT systems. The Prior Image Constrained Compressed Sensing (PICCS) algorithm was used to r...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735982
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:In intensity-modulated proton therapy (IMPT), protons are used to deliver highly conformal dose distributions, targeting tumors, and sparing organs-at-risk. However, due to uncertainties in both patient setup and relative stopping power (RSP) calculation, margins are added to the treatment volume during treatme...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14347
更新日期:2020-09-01 00:00:00
abstract::Electron energy spectra and angular distributions, including angular spreads, were measured using magnetic spectrometer techniques, at isocenter, for two clinical linear accelerators: one scanning beam machine, which achieves field flatness by scanning a pencil beam over the desired field at the patient plane, and one...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597817
更新日期:1996-05-01 00:00:00
abstract::We measured the physical imaging performance of a 41 x 41 cm2 amorphous silicon flat panel detector designed for angiographic and R&F imaging applications using methods from the emerging IEC standard for the measurement of detective quantum efficiency (DQE) in digital radiographic detectors. Measurements on 12 product...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1609151
更新日期:2003-10-01 00:00:00
abstract::Currently, two classes of the computational phantoms have been developed for dosimetry calculation: (1) stylized (or mathematical) and (2) voxel (or tomographic) phantoms describing human anatomy through mathematical surface equations and three-dimensional labeled voxel matrices, respectively. Mathematical surface equ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2912178
更新日期:2008-06-01 00:00:00
abstract::In nuclear magnetic resonance (NMR) imaging by the zeugmatographic methods, there is a common and unified theoretical description. All forms of two-dimensional and three-dimensional imaging involve NMR data which trace various geometric representations, in reciprocal transform space, of the subject's spatially blurred...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595470
更新日期:1984-01-01 00:00:00
abstract:PURPOSE:The variable resolution x-ray (VRX) CT scanner provides substantial improvement in the spatial resolution by matching the scanner's field of view (FOV) to the size of the object being imaged. Intercell x-ray cross-talk is one of the most important factors limiting the spatial resolution of the VRX detector. In ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3555035
更新日期:2011-03-01 00:00:00
abstract:PURPOSE:Compton camera imaging (CCI) systems are currently under investigation for radiotherapy dose reconstruction and verification. The ability of such a system to provide real-time images during dose delivery will be limited by the computational speed of the image reconstruction algorithm. In this work, the authors ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3519873
更新日期:2011-01-01 00:00:00
abstract::Recently, new imaging modalities based on the detection of weak phase perturbations effects, among which are phase contrast and diffraction imaging, have been developed by several researchers. Due to their high sensitivity to weakly absorbing details, these techniques seem to be very promising for applications in the ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1388219
更新日期:2001-08-01 00:00:00
abstract:PURPOSE:Cone beam computed tomography (CBCT) suffers from a large amount of scatter, resulting in severe scatter artifacts in the reconstructions. Recently, a new scatter correction approach, called improved primary modulator scatter estimation (iPMSE), was introduced. That approach utilizes a primary modulator that is...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12094
更新日期:2017-09-01 00:00:00
abstract::The purpose of this work is to investigate algorithms for the delivery of intensity-modulated fields using independent collimators (IC). Two heuristic algorithms are proposed to calculate jaw-setting sequences for arbitrary 2D intensity distributions. The first algorithm is based on searching the whole intensity matri...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598794
更新日期:1999-12-01 00:00:00
abstract:PURPOSE:State of the art to access radiofrequency (RF) heating near implants is computer modeling of the devices and solving Maxwell's equations for the specific setup. For a set of input parameters, a fixed result is obtained. This work presents a theoretical approach in the alternating current (ac) limit, which can p...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3637495
更新日期:2011-10-01 00:00:00
abstract::Computer algorithms for rotational therapy beams, in most cases, perform dose calculations by summing stored fixed beam data at finite angular steps. Such an algorithm, based on the Bentley beam model, was evaluated by comparing calculations with measured data for an 18-MV x-ray beam. Measurements were made in a speci...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595985
更新日期:1987-11-01 00:00:00
abstract:PURPOSE:The automated segmentation of each lung and trachea in CT scans is commonly taken as a solved problem. Indeed, existing approaches may easily fail in the presence of some abnormalities caused by a disease, trauma, or previous surgery. For robustness, we present ALTIS (implementation is available at http://lids....
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13773
更新日期:2019-11-01 00:00:00
abstract:PURPOSE:A radiophotoluminescent glass rod dosimeter (RGD) has recently become commercially available. It is being increasingly used for dosimetry in radiotherapy to measure the absorbed dose including scattered low-energy photons on the body surface of a patient and for postal dosimetry audit. In this article, the dosi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4747261
更新日期:2012-10-01 00:00:00
abstract::The geometric accuracy and precision of an image-guided treatment system were assessed. Image guidance is performed using an x-ray volume imaging (XVI) system integrated with a linear accelerator and treatment planning system. Using an amorphous silicon detector and x-ray tube, volumetric computed tomography images ar...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2143141
更新日期:2006-01-01 00:00:00
abstract:PURPOSE:Alpha-emitting radionuclides exhibit a potential advantage for cancer treatments because they release large amounts of ionizing energy over a few cell diameters (50-80 μm), causing localized, irreparable double-strand DNA breaks that lead to cell death. Radioimmunotherapy (RIT) approaches using monoclonal antib...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4921997
更新日期:2015-07-01 00:00:00
abstract:PURPOSE:Transrectal ultrasound (TRUS)-guided needle biopsy is the current gold standard for prostate cancer diagnosis. However, up to 40% of prostate cancer lesions appears isoechoic on TRUS. Hence, TRUS-guided biopsy has a high false negative rate for prostate cancer diagnosis. Magnetic resonance imaging (MRI) is bett...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4905104
更新日期:2015-03-01 00:00:00
abstract:PURPOSE:To review the issues a physicist may encounter in a community hospital during the transition from film/paper charts to a paperless environment with ARIA and a TrueBeam LINAC. With a lean budget, it was necessary for the physics group to take on the project management responsibilities in order save costs. This w...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735291
更新日期:2012-06-01 00:00:00
abstract::Multielectrode cochlear implantation is the most effective treatment for profound sensorineural hearing loss. In vivo three-dimensional 3-D localization of cochlear implant electrodes is important for modeling of the electrical field in the cochlea, design of electrode arrays, and may improve speech processor programm...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598940
更新日期:2000-04-01 00:00:00
abstract::Breast density, the percentage of glandular breast tissue, has been identified as an important yet underutilized risk factor in the development of breast cancer. A quantitative method to measure breast density with dual energy imaging was investigated using a computer simulation model. Two configurations to measure br...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3002308
更新日期:2008-12-01 00:00:00
abstract::Radiographic image guidance has emerged as the new paradigm for patient positioning, target localization, and external beam alignment in radiotherapy. Although widely varied in modality and method, all radiographic guidance techniques have one thing in common--they can give a significant radiation dose to the patient....
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2775667
更新日期:2007-10-01 00:00:00
abstract::An experiment to determine the peak of the energy spectrum of the photon beam from a Toshiba LMR-15 medical linear accelerator is described. It is found that the flattening filters removed much of the bremsstrahlung spectrum below approximately 1 MeV, resulting in a photon spectrum which peaks around 1.2 MeV. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595582
更新日期:1984-11-01 00:00:00
abstract::A PTW Riga diamond detector and LiF TLDs have been evaluated for use in proton beam dosimetry by comparing results of proton beam calibration with those obtained using thimble ionization chambers. The thimble ionization chambers were calibrated in terms of exposure while the TLDs and diamond detector were calibrated i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597608
更新日期:1995-04-01 00:00:00
abstract::Contemporary reconstruction methods employed for clinical helical cone-beam computed tomography (CT) are analytical (noniterative) but mathematically nonexact, i.e., the reconstructed image contains so called cone-beam artifacts, especially for higher cone angles. Besides cone artifacts, these methods also suffer from...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2966353
更新日期:2008-09-01 00:00:00
abstract:PURPOSE:Talbot-Lau x-ray interferometry provides information about the scattering and refractive properties of an object - in addition to the object's attenuation features. Until recently, this method was ineligible for imaging human-sized objects as it is challenging to adapt Talbot-Lau interferometers (TLIs) to the r...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12889
更新日期:2018-06-01 00:00:00
abstract:PURPOSE:To correct for the deviations of the detector response when typical radiation detectors are used under non-reference conditions, factor kNR was calculated from the known energy dependence of the detector response at photon energies from 10 keV upwards and from clinical photon spectra within a large water phanto...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735184
更新日期:2012-06-01 00:00:00
abstract::The propagation of noise in digitized images arrived at by algebraic manipulation of two images has been investigated. The algebraic manipulations investigated were logarithmic subtraction, linear subtraction, and division of the two images. The two images were identical except for the presence of a contrast-adding co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595289
更新日期:1983-01-01 00:00:00
abstract:PURPOSE:Episcleral eye plaque brachytherapy has been utilized in the treatment of intra-ocular malignancies, delivering large prescription doses to the apex of the tumor. Advances in dose calculation and image guidance, via calibrated fundus images, enable localization of the tumor and determination of dose to the macu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735518
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The lateral edge of a proton therapy beam is commonly used to achieve conformality to the treatment volume where critical structures reside close to the target. However, when treating shallow depths, the lateral edge of a pencil beam scanning (PBS) system may be broader than that of a double scattered (DS) syst...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4941957
更新日期:2016-03-01 00:00:00