SU-E-I-41: Characterization of a Linear Fiber-Optic Coupled Dosimeter.

Abstract:

PURPOSE:This study investigated the dosimetry performance of a linear fiber-optic coupled dosimeter with a sensitive element varying from 3 to 15 cm in length. The dosimeter is comprised of a tissue equivalent plastic scintillating fiber coupled to a photomultiplier tube (PMT). The sensitive element has a length representative of the dimensions of common adult internal organs and measures the absorbed dose along the entire sensitive length. The measurement of absorbed dose in one dimensional space provides a more meaningful measure of the average organ dose compared to current dosimeters which evaluate the dose at a small volume, or point inside the organ. METHOD AND MATERIALS:A fiber-optic coupled dosimetry system was modified by increasing the linear dimension of the sensitive element to sizes ranging from 3 to 15 cm. A FOC element providing a variable output as a function of exposed dosimeter length, beam energy, depth, and beam intensity, was characterized for various exposure parameters relating to Computed Tomography. A clinical x-ray tube, with half-value layer of 5.60 mm Al at 120 kVp, was used to evaluate the dosimeter response to beam energy, intensity, beam quality, and exposed length. RESULTS:The system consistently demonstrated linearity with tube output and length of the sensitive element and offering excellent sensitivity and reproducibility. The dosimeter also demonstrated a linear response of detected counts to length of scintillation material in the x-ray field over the range of interest. The sensitivity with respect to energy and depth showed a positive linear dependence. An 8% variation in sensitivity across a 12 cm depth was observed within a soft tissue-equivalent medium. CONCLUSION:The system allows for rapid and accurate average organ dose measurements relevant to x-ray sources within the diagnostic energy range. The response to previously discussed parameters was independent of the sensitive element length.

journal_name

Med Phys

journal_title

Medical physics

authors

Hoerner M,Hintenlang D

doi

10.1118/1.4734756

subject

Has Abstract

pub_date

2012-06-01 00:00:00

pages

3634

issue

6Part4

eissn

0094-2405

issn

2473-4209

journal_volume

39

pub_type

杂志文章
  • Evaluation of carbon nanotube x-ray source array for stationary head computed tomography.

    abstract:PURPOSE:Stationary computed tomography (s-CT) conceptually offers several advantages over existing rotating gantry-based CT. Over the last 40 yr, s-CT has been investigated using different technological approaches. We are developing a s-CT system specifically for head/brain imaging using carbon nanotube (CNT)-based fie...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14696

    authors: Spronk D,Luo Y,Inscoe CR,Lee YZ,Lu J,Zhou O

    更新日期:2020-12-31 00:00:00

  • Bremsstrahlung production at 50 MeV in different target materials and configurations.

    abstract::A combination of Monte Carlo, convolution, and experimental techniques have been used to investigate bremsstrahlung production at 50 MeV in full-range targets to produce narrow elementary photon beams for scanning. Calculations using the ITS 3.0 Monte Carlo system for various target designs, including particle transpo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597681

    authors: Sätherberg A,Andreo P,Karlsson M

    更新日期:1996-04-01 00:00:00

  • A deep feature fusion methodology for breast cancer diagnosis demonstrated on three imaging modality datasets.

    abstract:BACKGROUND:Deep learning methods for radiomics/computer-aided diagnosis (CADx) are often prohibited by small datasets, long computation time, and the need for extensive image preprocessing. AIMS:We aim to develop a breast CADx methodology that addresses the aforementioned issues by exploiting the efficiency of pre-tra...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12453

    authors: Antropova N,Huynh BQ,Giger ML

    更新日期:2017-10-01 00:00:00

  • SU-E-T-610: Impact of Variable Beam Spot Size on Treatment Time in Particle Therapy.

    abstract:PURPOSE:The dosimetric advantage of particle therapy comes with a much higher infrastructure investment and operation costs. Increasing patient throughput is a key factor to manage operation costs. We investigate the impact of variable beam spot sizes on treatment time and discuss the tradeoffs involved. METHODS:The f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735699

    authors: Riofrio D,Sellner S,Cabal G,Keyes R,Holzscheiter M,Jaekel O,Luan S

    更新日期:2012-06-01 00:00:00

  • A Monte Carlo study on the collimation of pencil beam scanning proton therapy beams.

    abstract:PURPOSE:The lateral edge of a proton therapy beam is commonly used to achieve conformality to the treatment volume where critical structures reside close to the target. However, when treating shallow depths, the lateral edge of a pencil beam scanning (PBS) system may be broader than that of a double scattered (DS) syst...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4941957

    authors: Charlwood FC,Aitkenhead AH,Mackay RI

    更新日期:2016-03-01 00:00:00

  • A method to compare supra-pubic ultrasound and CT images of the prostate: technique and early clinical results.

    abstract::We describe a unique method that allows the comparison of spatially registered ultrasound (SRUS) images and computed tomography-derived contours (CTDCs) that were acquired with a minimal time lapse. As such, we have a tool that will provide validation of the spatial accuracy of the US system and that will allow compar...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1644515

    authors: Molloy JA,Srivastava S,Schneider BF

    更新日期:2004-03-01 00:00:00

  • A comparison of reconstruction algorithms for C-arm mammography tomosynthesis.

    abstract::Digital tomosynthesis is an imaging technique to produce a tomographic image from a series of angular digital images in a manner similar to conventional focal plane tomography. Unlike film focal plane tomography, the acquisition of the data in a C-arm geometry causes the image receptor to be positioned at various angl...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2219090

    authors: Rakowski JT,Dennis MJ

    更新日期:2006-08-01 00:00:00

  • Phantom size in brachytherapy source dosimetric studies.

    abstract::An important point to consider in a brachytherapy dosimetry study is the phantom size involved in calculations or experimental measurements. As pointed out by Williamson [Med. Phys. 18, 776-786 (1991)] this topic has a relevant influence on final dosimetric results. Presently, one-dimensional (1-D) algorithms and newl...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1759826

    authors: Pérez-Calatayud J,Granero D,Ballester F

    更新日期:2004-07-01 00:00:00

  • Reference standard and statistical model for intersite and temporal comparisons of CT attenuation in a multicenter quantitative lung study.

    abstract:PURPOSE:The purpose of this study was to detect and analyze anomalies between a large number of computed tomography (CT) scanners, tracked over time, utilized to collect human pulmonary CT data for a national multicenter study: chronic obstructive pulmonary disease genetic epidemiology study (COPDGene). METHODS:A cust...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1118/1.4747342

    authors: Sieren JP,Newell JD,Judy PF,Lynch DA,Chan KS,Guo J,Hoffman EA

    更新日期:2012-09-01 00:00:00

  • First study of on-treatment volumetric imaging during respiratory gated VMAT.

    abstract:PURPOSE:To obtain on-treatment volumetric patient anatomy during respiratory gated volumetric modulated arc therapy (VMAT). METHODS:On-board imaging device integrated with Linacs offers a viable tool for obtaining patient anatomy during radiation treatment delivery. In this study, the authors acquired beam-level kV im...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1118/1.4794925

    authors: Choi K,Xing L,Koong A,Li R

    更新日期:2013-04-01 00:00:00

  • Low-dose dynamic myocardial perfusion CT imaging using a motion adaptive sparsity prior.

    abstract:PURPOSE:Dynamic myocardial perfusion computed tomography (DM-PCT) imaging offers benefits over quantitative assessment of myocardial blood flow (MBF) for diagnosis and risk stratification of coronary artery disease. However, one major drawback of DM-PCT imaging is that a high radiation level is imparted by repeated sca...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12285

    authors: Bian Z,Zeng D,Zhang Z,Gong C,Tian X,Yan G,Huang J,Guo H,Chen B,Zhang J,Feng Q,Chen W,Ma J

    更新日期:2017-09-01 00:00:00

  • Technical Note: Identification of an optimal electromagnetic sensor for in vivo electromagnetic-tracked scintillation dosimeter for HDR brachytherapy.

    abstract:PURPOSE:Brachytherapy is a treatment modality which delivers large doses of radiation in a reduced number of visits. Since a small number of large dose-per-fraction is administered in high dose rate brachytherapy, ensuring the right dose is delivered is highly critical. In this work, a scintillation detector is coupled...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13508

    authors: Tho D,Beaulieu L

    更新日期:2019-05-01 00:00:00

  • Interplay effect on a 6-MV flattening-filter-free linear accelerator with high dose rate and fast multi-leaf collimator motion treating breast and lung phantoms.

    abstract:PURPOSE:Using a new linear accelerator with high dose rate (800 MU/min), fast MLC motions (5.0 cm/s), fast gantry rotation (15 s/rotation), and 1 cm wide MLCs, we aimed to quantify the effects of complexity, arc number, and fractionation on interplay for breast and lung treatments under target motion. METHODS:To study...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12899

    authors: Netherton T,Li Y,Nitsch P,Shaitelman S,Balter P,Gao S,Klopp A,Muruganandham M,Court L

    更新日期:2018-06-01 00:00:00

  • Evaluation of the local dose enhancement in the combination of proton therapy and nanoparticles.

    abstract:PURPOSE:The outcome of radiotherapy can be further improved by combining irradiation with dose enhancers such as high-Z nanoparticles. Since 2004, spectacular results have been obtained when low-energy x-ray irradiations have been combined with nanoparticles. Recently, the same combination has been explored in hadron t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4934370

    authors: Martínez-Rovira I,Prezado Y

    更新日期:2015-11-01 00:00:00

  • A regional convolution kernel algorithm for scatter correction in dual-energy images: comparison to single-kernel algorithms.

    abstract::Single kernel scatter correction algorithms are based on the model that the scatter field can be predicted by convolution of the primary intensity (Iprim) with a spatially invariant scatter point-spread function (PSF). Practical limitations (Iprim unknown) suggest the substitution of the total detected intensity (Idet...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597297

    authors: Kruger DG,Zink F,Peppler WW,Ergun DL,Mistretta CA

    更新日期:1994-02-01 00:00:00

  • Poster - Thur Eve - 23: Statistical analysis and verification of the percentage depth dose calculation based on the tissue maximum ratio in external beam radiotherapy.

    abstract::The aim of this study is to perform a statistical analysis to verify the calculated percentage depth dose (PDD) based on the tissue maximum ratio (TMR) with the PDD measurements taken in water. 6 and 15 MV photon beams produced by a Varian linear 2100 C/D accelerator were used. PDDs and TMRs were measured at various d...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740131

    authors: Isa M,Iqbal K,Afzal M,Buzdar S,Chow J

    更新日期:2012-07-01 00:00:00

  • Analysis of fractionation correction methodologies for multiple phase treatment plans in radiation therapy.

    abstract:PURPOSE:Radiation therapy is often delivered by multiple sequential treatment plans. For an accurate radiobiological evaluation of the overall treatment, fractionation corrections to each dose distribution must be applied before summing the three-dimensional dose matrix of each plan since the simpler approach of perfor...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4792636

    authors: Mavroidis P,Ferreira BC,Papanikolaou N,Lopes Mdo C

    更新日期:2013-03-01 00:00:00

  • An investigation of a new amorphous silicon electronic portal imaging device for transit dosimetry.

    abstract::The relationship between the pixel value and exit dose was investigated for a new commercially available amorphous silicon electronic portal imaging device. The pixel to dose mapping function was established to be linear for detector distances between 116.5 cm to 150 cm from the source, radiation field sizes from 5 x ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1508108

    authors: Grein EE,Lee R,Luchka K

    更新日期:2002-10-01 00:00:00

  • SU-E-T-541: Dose Calculation Algorithm for External Neutron Radiotherapy Based on Pencil Beam Method.

    abstract:PURPOSE:To evaluate the availability and performance of pencil beam algorithm for fast neutrons radiotherapy dose calculations and to achieve improvements in universality, speed and inhomogeneities corrections. METHODS:Pencil beam (PB) method uses integration of dose kernel cross field size to estimate dose distributi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735630

    authors: Moiseev A,Klimanov V

    更新日期:2012-06-01 00:00:00

  • Target motion measurement without implanted markers and its validation by comparison with manually obtained data.

    abstract::For an effective radiotherapy the exact tumor location must be determined. The localization has to take into account patient's setup position as well as internal organ motion. Among the different localization methods, the use of a computer tomography (CT) scanner in the therapy room has been proposed recently. Achievi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2103447

    authors: Vences L,Wulf J,Vordermark D,Sauer O,Berlinger K,Roth M

    更新日期:2005-11-01 00:00:00

  • Technical Note: Cortical thickness and density estimation from clinical CT using a prior thickness-density relationship.

    abstract:PURPOSE:Cortical thickness and density are critical components in determining the strength of bony structures. Computed tomography (CT) is one possible modality for analyzing the cortex in 3D. In this paper, a model-based approach for measuring the cortical bone thickness and density from clinical CT images is proposed...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4944501

    authors: Humbert L,Hazrati Marangalou J,Del Río Barquero LM,van Lenthe GH,van Rietbergen B

    更新日期:2016-04-01 00:00:00

  • Development of a dynamic quality assurance testing protocol for multisite clinical trial DCE-CT accreditation.

    abstract:PURPOSE:Credentialing can have an impact on whether or not a clinical trial produces useful quality data that is comparable between various institutions and scanners. With the recent increase of dynamic contrast enhanced-computed tomography (DCE-CT) usage as a companion biomarker in clinical trials, effective quality a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4812429

    authors: Driscoll B,Keller H,Jaffray D,Coolens C

    更新日期:2013-08-01 00:00:00

  • Three-dimensional canine heart model for cardiac elastography.

    abstract:PURPOSE:A three-dimensional finite element analysis based canine heart model is introduced that would enable the assessment of cardiac function. METHODS:The three-dimensional canine heart model is based on the cardiac deformation and motion model obtained from the Cardiac Mechanics Research Group at UCSD. The canine h...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3496326

    authors: Chen H,Varghese T

    更新日期:2010-11-01 00:00:00

  • X-ray imaging with amorphous selenium: X-ray to charge conversion gain and avalanche multiplication gain.

    abstract::Fluoroscopy is a low dose imaging technique. As such, a very sensitive detector is required to create images of good quality. Present day flat panel active matrix read out systems introduce an amount of noise that inhibits present direct and indirect methods from producing optimal quality images at fluoroscopic exposu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1513157

    authors: Hunt DC,Kirby SS,Rowlands JA

    更新日期:2002-11-01 00:00:00

  • A mouse radiation-induced liver disease model for stereotactic body radiation therapy validated in patients with hepatocellular carcinoma.

    abstract:PURPOSE:Lower radiation tolerance of the whole liver hinders dose escalations of stereotactic body radiation therapy (SBRT) in hepatocellular carcinoma (HCC) treatment. This study was conducted to define the exact doses that result in radiation-induced liver disease (RILD) as well as to determine dose constraints for t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4953831

    authors: Wu ZF,Zhang JY,Shen XY,Zhou LY,Gao YB,Hu Y,Zeng ZC

    更新日期:2016-07-01 00:00:00

  • Measuring uncertainty in dose delivered to the cochlea due to setup error during external beam treatment of patients with cancer of the head and neck.

    abstract:PURPOSE:To use Cone Beam CT scans obtained just prior to treatments of head and neck cancer patients to measure the setup error and cumulative dose uncertainty of the cochlea. METHODS:Data from 10 head and neck patients with 10 planning CTs and 52 Cone Beam CTs taken at time of treatment were used in this study. Patie...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4830427

    authors: Yan M,Lovelock D,Hunt M,Mechalakos J,Hu Y,Pham H,Jackson A

    更新日期:2013-12-01 00:00:00

  • Design and performance of a compact and stationary microSPECT system.

    abstract:PURPOSE:Over the last ten years, there has been an extensive growth in the development of microSPECT imagers. Most of the systems are based on the combination of conventional, relatively large gamma cameras with poor intrinsic spatial resolution and multipinhole collimators working in large magnification mode. Spatial ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4822621

    authors: Van Holen R,Vandeghinste B,Deprez K,Vandenberghe S

    更新日期:2013-11-01 00:00:00

  • Comparison of p-type commercial electron diodes for in vivo dosimetry.

    abstract::This paper compares the characteristics of three types of commercial p-type electron diodes specially designed for in vivo dosimetry (Scanditronix EDD2, Sun Nuclear QED 111200-0 and PTW T60010E diodes coupled with a Therados DPD510 dosimeter) in electron fields with energies from 4.5 to 21 MeV, and in conditions simil...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1630492

    authors: Marre D,Marinello G

    更新日期:2004-01-01 00:00:00

  • SU-E-T-558: Assessing the Effect of Inter-Fractional Motion in Esophageal Sparing Plans.

    abstract:PURPOSE:To compare esophageal dose distributions in esophageal sparing IMRT plans with predicted dose distributions which include the effect of inter-fraction motion. METHODS:Seven lung cancer patients were used, each with a standard and an esophageal sparing plan (74Gy, 2Gy fractions). The average max dose to esophag...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735647

    authors: Williamson R,Bluett J,Niedzielski J,Liao Z,Gomez D,Court L

    更新日期:2012-06-01 00:00:00

  • Small-field electron dosimetry for the Philips SL25 linear accelerator.

    abstract::Electron-beam characteristics of a Philips SL25 linear accelerator have been studied. Central-axis percentage depth doses, cross-beam profiles and beam output factors of 6-, 10-, and 20-MeV beams, selected from the available energy range of 4 to 22 MeV, are reported in this paper. The main thrust of this work is to de...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596471

    authors: Rashid H,Islam MK,Gaballa H,Rosenow UF,Ting JY

    更新日期:1990-07-01 00:00:00