Abstract:
PURPOSE:This study investigated the dosimetry performance of a linear fiber-optic coupled dosimeter with a sensitive element varying from 3 to 15 cm in length. The dosimeter is comprised of a tissue equivalent plastic scintillating fiber coupled to a photomultiplier tube (PMT). The sensitive element has a length representative of the dimensions of common adult internal organs and measures the absorbed dose along the entire sensitive length. The measurement of absorbed dose in one dimensional space provides a more meaningful measure of the average organ dose compared to current dosimeters which evaluate the dose at a small volume, or point inside the organ. METHOD AND MATERIALS:A fiber-optic coupled dosimetry system was modified by increasing the linear dimension of the sensitive element to sizes ranging from 3 to 15 cm. A FOC element providing a variable output as a function of exposed dosimeter length, beam energy, depth, and beam intensity, was characterized for various exposure parameters relating to Computed Tomography. A clinical x-ray tube, with half-value layer of 5.60 mm Al at 120 kVp, was used to evaluate the dosimeter response to beam energy, intensity, beam quality, and exposed length. RESULTS:The system consistently demonstrated linearity with tube output and length of the sensitive element and offering excellent sensitivity and reproducibility. The dosimeter also demonstrated a linear response of detected counts to length of scintillation material in the x-ray field over the range of interest. The sensitivity with respect to energy and depth showed a positive linear dependence. An 8% variation in sensitivity across a 12 cm depth was observed within a soft tissue-equivalent medium. CONCLUSION:The system allows for rapid and accurate average organ dose measurements relevant to x-ray sources within the diagnostic energy range. The response to previously discussed parameters was independent of the sensitive element length.
journal_name
Med Physjournal_title
Medical physicsauthors
Hoerner M,Hintenlang Ddoi
10.1118/1.4734756subject
Has Abstractpub_date
2012-06-01 00:00:00pages
3634issue
6Part4eissn
0094-2405issn
2473-4209journal_volume
39pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:Stationary computed tomography (s-CT) conceptually offers several advantages over existing rotating gantry-based CT. Over the last 40 yr, s-CT has been investigated using different technological approaches. We are developing a s-CT system specifically for head/brain imaging using carbon nanotube (CNT)-based fie...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14696
更新日期:2020-12-31 00:00:00
abstract::A combination of Monte Carlo, convolution, and experimental techniques have been used to investigate bremsstrahlung production at 50 MeV in full-range targets to produce narrow elementary photon beams for scanning. Calculations using the ITS 3.0 Monte Carlo system for various target designs, including particle transpo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597681
更新日期:1996-04-01 00:00:00
abstract:BACKGROUND:Deep learning methods for radiomics/computer-aided diagnosis (CADx) are often prohibited by small datasets, long computation time, and the need for extensive image preprocessing. AIMS:We aim to develop a breast CADx methodology that addresses the aforementioned issues by exploiting the efficiency of pre-tra...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12453
更新日期:2017-10-01 00:00:00
abstract:PURPOSE:The dosimetric advantage of particle therapy comes with a much higher infrastructure investment and operation costs. Increasing patient throughput is a key factor to manage operation costs. We investigate the impact of variable beam spot sizes on treatment time and discuss the tradeoffs involved. METHODS:The f...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735699
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The lateral edge of a proton therapy beam is commonly used to achieve conformality to the treatment volume where critical structures reside close to the target. However, when treating shallow depths, the lateral edge of a pencil beam scanning (PBS) system may be broader than that of a double scattered (DS) syst...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4941957
更新日期:2016-03-01 00:00:00
abstract::We describe a unique method that allows the comparison of spatially registered ultrasound (SRUS) images and computed tomography-derived contours (CTDCs) that were acquired with a minimal time lapse. As such, we have a tool that will provide validation of the spatial accuracy of the US system and that will allow compar...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1644515
更新日期:2004-03-01 00:00:00
abstract::Digital tomosynthesis is an imaging technique to produce a tomographic image from a series of angular digital images in a manner similar to conventional focal plane tomography. Unlike film focal plane tomography, the acquisition of the data in a C-arm geometry causes the image receptor to be positioned at various angl...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2219090
更新日期:2006-08-01 00:00:00
abstract::An important point to consider in a brachytherapy dosimetry study is the phantom size involved in calculations or experimental measurements. As pointed out by Williamson [Med. Phys. 18, 776-786 (1991)] this topic has a relevant influence on final dosimetric results. Presently, one-dimensional (1-D) algorithms and newl...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1759826
更新日期:2004-07-01 00:00:00
abstract:PURPOSE:The purpose of this study was to detect and analyze anomalies between a large number of computed tomography (CT) scanners, tracked over time, utilized to collect human pulmonary CT data for a national multicenter study: chronic obstructive pulmonary disease genetic epidemiology study (COPDGene). METHODS:A cust...
journal_title:Medical physics
pub_type: 杂志文章,多中心研究
doi:10.1118/1.4747342
更新日期:2012-09-01 00:00:00
abstract:PURPOSE:To obtain on-treatment volumetric patient anatomy during respiratory gated volumetric modulated arc therapy (VMAT). METHODS:On-board imaging device integrated with Linacs offers a viable tool for obtaining patient anatomy during radiation treatment delivery. In this study, the authors acquired beam-level kV im...
journal_title:Medical physics
pub_type: 信件
doi:10.1118/1.4794925
更新日期:2013-04-01 00:00:00
abstract:PURPOSE:Dynamic myocardial perfusion computed tomography (DM-PCT) imaging offers benefits over quantitative assessment of myocardial blood flow (MBF) for diagnosis and risk stratification of coronary artery disease. However, one major drawback of DM-PCT imaging is that a high radiation level is imparted by repeated sca...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12285
更新日期:2017-09-01 00:00:00
abstract:PURPOSE:Brachytherapy is a treatment modality which delivers large doses of radiation in a reduced number of visits. Since a small number of large dose-per-fraction is administered in high dose rate brachytherapy, ensuring the right dose is delivered is highly critical. In this work, a scintillation detector is coupled...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13508
更新日期:2019-05-01 00:00:00
abstract:PURPOSE:Using a new linear accelerator with high dose rate (800 MU/min), fast MLC motions (5.0 cm/s), fast gantry rotation (15 s/rotation), and 1 cm wide MLCs, we aimed to quantify the effects of complexity, arc number, and fractionation on interplay for breast and lung treatments under target motion. METHODS:To study...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12899
更新日期:2018-06-01 00:00:00
abstract:PURPOSE:The outcome of radiotherapy can be further improved by combining irradiation with dose enhancers such as high-Z nanoparticles. Since 2004, spectacular results have been obtained when low-energy x-ray irradiations have been combined with nanoparticles. Recently, the same combination has been explored in hadron t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4934370
更新日期:2015-11-01 00:00:00
abstract::Single kernel scatter correction algorithms are based on the model that the scatter field can be predicted by convolution of the primary intensity (Iprim) with a spatially invariant scatter point-spread function (PSF). Practical limitations (Iprim unknown) suggest the substitution of the total detected intensity (Idet...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597297
更新日期:1994-02-01 00:00:00
abstract::The aim of this study is to perform a statistical analysis to verify the calculated percentage depth dose (PDD) based on the tissue maximum ratio (TMR) with the PDD measurements taken in water. 6 and 15 MV photon beams produced by a Varian linear 2100 C/D accelerator were used. PDDs and TMRs were measured at various d...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4740131
更新日期:2012-07-01 00:00:00
abstract:PURPOSE:Radiation therapy is often delivered by multiple sequential treatment plans. For an accurate radiobiological evaluation of the overall treatment, fractionation corrections to each dose distribution must be applied before summing the three-dimensional dose matrix of each plan since the simpler approach of perfor...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4792636
更新日期:2013-03-01 00:00:00
abstract::The relationship between the pixel value and exit dose was investigated for a new commercially available amorphous silicon electronic portal imaging device. The pixel to dose mapping function was established to be linear for detector distances between 116.5 cm to 150 cm from the source, radiation field sizes from 5 x ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1508108
更新日期:2002-10-01 00:00:00
abstract:PURPOSE:To evaluate the availability and performance of pencil beam algorithm for fast neutrons radiotherapy dose calculations and to achieve improvements in universality, speed and inhomogeneities corrections. METHODS:Pencil beam (PB) method uses integration of dose kernel cross field size to estimate dose distributi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735630
更新日期:2012-06-01 00:00:00
abstract::For an effective radiotherapy the exact tumor location must be determined. The localization has to take into account patient's setup position as well as internal organ motion. Among the different localization methods, the use of a computer tomography (CT) scanner in the therapy room has been proposed recently. Achievi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2103447
更新日期:2005-11-01 00:00:00
abstract:PURPOSE:Cortical thickness and density are critical components in determining the strength of bony structures. Computed tomography (CT) is one possible modality for analyzing the cortex in 3D. In this paper, a model-based approach for measuring the cortical bone thickness and density from clinical CT images is proposed...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4944501
更新日期:2016-04-01 00:00:00
abstract:PURPOSE:Credentialing can have an impact on whether or not a clinical trial produces useful quality data that is comparable between various institutions and scanners. With the recent increase of dynamic contrast enhanced-computed tomography (DCE-CT) usage as a companion biomarker in clinical trials, effective quality a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4812429
更新日期:2013-08-01 00:00:00
abstract:PURPOSE:A three-dimensional finite element analysis based canine heart model is introduced that would enable the assessment of cardiac function. METHODS:The three-dimensional canine heart model is based on the cardiac deformation and motion model obtained from the Cardiac Mechanics Research Group at UCSD. The canine h...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3496326
更新日期:2010-11-01 00:00:00
abstract::Fluoroscopy is a low dose imaging technique. As such, a very sensitive detector is required to create images of good quality. Present day flat panel active matrix read out systems introduce an amount of noise that inhibits present direct and indirect methods from producing optimal quality images at fluoroscopic exposu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1513157
更新日期:2002-11-01 00:00:00
abstract:PURPOSE:Lower radiation tolerance of the whole liver hinders dose escalations of stereotactic body radiation therapy (SBRT) in hepatocellular carcinoma (HCC) treatment. This study was conducted to define the exact doses that result in radiation-induced liver disease (RILD) as well as to determine dose constraints for t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4953831
更新日期:2016-07-01 00:00:00
abstract:PURPOSE:To use Cone Beam CT scans obtained just prior to treatments of head and neck cancer patients to measure the setup error and cumulative dose uncertainty of the cochlea. METHODS:Data from 10 head and neck patients with 10 planning CTs and 52 Cone Beam CTs taken at time of treatment were used in this study. Patie...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4830427
更新日期:2013-12-01 00:00:00
abstract:PURPOSE:Over the last ten years, there has been an extensive growth in the development of microSPECT imagers. Most of the systems are based on the combination of conventional, relatively large gamma cameras with poor intrinsic spatial resolution and multipinhole collimators working in large magnification mode. Spatial ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4822621
更新日期:2013-11-01 00:00:00
abstract::This paper compares the characteristics of three types of commercial p-type electron diodes specially designed for in vivo dosimetry (Scanditronix EDD2, Sun Nuclear QED 111200-0 and PTW T60010E diodes coupled with a Therados DPD510 dosimeter) in electron fields with energies from 4.5 to 21 MeV, and in conditions simil...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1630492
更新日期:2004-01-01 00:00:00
abstract:PURPOSE:To compare esophageal dose distributions in esophageal sparing IMRT plans with predicted dose distributions which include the effect of inter-fraction motion. METHODS:Seven lung cancer patients were used, each with a standard and an esophageal sparing plan (74Gy, 2Gy fractions). The average max dose to esophag...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735647
更新日期:2012-06-01 00:00:00
abstract::Electron-beam characteristics of a Philips SL25 linear accelerator have been studied. Central-axis percentage depth doses, cross-beam profiles and beam output factors of 6-, 10-, and 20-MeV beams, selected from the available energy range of 4 to 22 MeV, are reported in this paper. The main thrust of this work is to de...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596471
更新日期:1990-07-01 00:00:00