Abstract:
PURPOSE:Sterile radiation reduction gloves have been widely used in the past decade to provide modest decreases in operator hand dose when the hands are placed in the field of view (FOV). While multiple publications have quantified the potential dose reduction from the use of such gloves, possible effects on the patient have not yet been assessed. The aim of this study was to determine if radiation reduction gloves can Result in a significant increase in patient dose and increased risk of radiation induced skin injury when used in interventional radiology. METHODS:The effect of radiation reduction gloves when used in the FOV was determined by measurement of patient entrance exposure rate (EER) for a variety of patient sizes and varying operating and magnification modes. EERs were measured with no glove in the FOV, with one glove and, to replicate the actions of many dose-conscious radiologists, with double gloves in the FOV. RESULTS:Compared to an ungloved hand, the use of a single radiation reduction glove near the center of the FOV results in a 2-fold average increase in patient EER. The use of double radiation reduction gloves results in a 3-fold average increase in EER. In both cases, this increase was only weakly dependent on the size of the patient and on the operating and magnification modes used. In fact, patient thicknesses ranging from 6-14 inches and operating modes ranging from low-dose fluoroscopy to DSA produced less than a 20% deviation from the increases in EER quoted above. CONCLUSIONS:When used in the FOV, radiation reduction gloves can substantially increase patient EER. This increase in patient dose, when compared with the relatively small published reduction in extremity dose provided to the operator, may make their use contraindicated in cases where radiation induced skin injury is a possible risk.
journal_name
Med Physjournal_title
Medical physicsauthors
Pasciak A,Neveu M,Sriharan A,Balius A,Jones Adoi
10.1118/1.4734747subject
Has Abstractpub_date
2012-06-01 00:00:00pages
3632issue
6Part4eissn
0094-2405issn
2473-4209journal_volume
39pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::Cone beam computed tomography (CBCT) is a relatively new patient imaging technique that has proved invaluable for treatment target verification and patient positioning during image-guided radiotherapy (IGRT). It has been shown that CBCT results in additional dose to bone that may amount to 10% of the prescribed dose. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3147143
更新日期:2009-07-01 00:00:00
abstract::A formulation of the single energy photon transport problem is cast in the form of a series of convolutions over the primary fluence distribution with invariant kernels. A method is developed for compensating for the variant intervoxel attenuation in the scattered dose distribution by means of an invariant correction ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595964
更新日期:1986-07-01 00:00:00
abstract::A detailed derivation is presented of the formulas required to determine Ngas and Dmed in the AAPM TG-21 dosimetry protocol. This protocol specifies how to determine the absorbed dose in an electron or photon beam when using exposure or absorbed dose calibrated ion chambers. It is shown that the expression given in TG...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596292
更新日期:1988-01-01 00:00:00
abstract::Attention is given to means of sensing ultrasonic energy distributions over an area. Under the restraints appropiate to real-time imaging of deep body organs, piezoelectric arrays offer the most promising method. Adaptation of integrated circuit techniques to array assembly permits very large arrays of small elements ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594247
更新日期:1976-09-01 00:00:00
abstract::Secondary neutron ambient dose equivalents per the treatment absorbed dose in passive carbon-ion and proton radiotherapies were measured using a rem meter, WENDI-II at two carbon-ion radiotherapy facilities and four proton radiotherapy facilities in Japan. Our measured results showed that (1) neutron ambient dose equi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2989019
更新日期:2008-11-01 00:00:00
abstract::Current methods for imaging joint motion are limited to either two-dimensional (2D) video fluoroscopy, or to animated motions from a series of static three-dimensional (3D) images. 3D movement patterns can be detected from biplane fluoroscopy images matched with computed tomography images. This involves several x-ray ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2000647
更新日期:2005-09-01 00:00:00
abstract::Machine outputs, peak scatter factors, and central axis percentage depth dose distributions were measured for various phantom sizes in large radiation fields produced at extended distances by cobalt, 6-MV, and 10-MV photon beams. The results can be applied to practical total body irradiation procedures which usually i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595686
更新日期:1985-09-01 00:00:00
abstract::Multi-instrument activity estimation and decay correction techniques were developed for radionuclide mixtures, motivated by the desire for accurate quantitation of Tc-94m positron emission tomography (PET) studies. Tc-94m and byproduct Tc isotopes were produced by proton irradiation of enriched Mo-94 and natural Mo ta...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1333411
更新日期:2001-01-01 00:00:00
abstract::Single kernel scatter correction algorithms are based on the model that the scatter field can be predicted by convolution of the primary intensity (Iprim) with a spatially invariant scatter point-spread function (PSF). Practical limitations (Iprim unknown) suggest the substitution of the total detected intensity (Idet...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597297
更新日期:1994-02-01 00:00:00
abstract:PURPOSE:Linac-magnetic resonance (MR) systems have been proposed in order to achieve realtime image guided radiotherapy. The design of a new linac-MR system with the in-line 6 MV linac generating x-rays along the symmetry axis of an open MR imager is outlined. This new design allows for a greater MR field strength to a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3481513
更新日期:2010-09-01 00:00:00
abstract::In the last 30 years, thousands of basic or clinical studies have been devoted to atherosclerosis or to the problem of restenosis after angioplasty. In these studies, axial stresses in the vessel wall have received practically no attention, contrary to circumferential stress and purely biological aspects. Based on a r...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1844432
更新日期:2005-02-01 00:00:00
abstract::Quantitative analysis of dynamic gadolinium-DTPA (diethylenetriamine pentaacetic acid) enhanced magnetic resonance imaging (MRI) is emerging as a highly sensitive tool for detecting malignant breast tissue. Three-dimensional rapid imaging techniques, such as keyhole MRI, yield high temporal sampling rates to accuratel...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598576
更新日期:1999-05-01 00:00:00
abstract::The anti-scatter grid has been widely used to reject scatter and increase the perceptibility of a low-contrast object in chest radiography; however, it also attenuated the primary x-rays, resulting in a substantial loss of information and an increased relative noise level in heavily attenuated regions. A more dose eff...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2739805
更新日期:2007-07-01 00:00:00
abstract:PURPOSE:The availability of accurate and simple models for the estimation of x-ray spectra is of great importance for system simulation, optimization, or inclusion of photon energy information into data processing. There is a variety of publicly available tools for estimation of x-ray spectra in radiology and mammograp...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4837220
更新日期:2014-01-01 00:00:00
abstract:PURPOSE:To design an efficient method for utilizing phase-space source models in the GPU-based Monte Carlo (MC) dose calculation engine gDPM. METHODS:In GPU-based MC algorithms, particles are transported in parallel on different threads. Particles of different types and energies can require significantly different exe...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735565
更新日期:2012-06-01 00:00:00
abstract::Radiation sensitive gels have been used as dosimeters for clinical dose verification of different radiation therapy modalities. However, the use of gels is not widespread, because careful techniques are required to achieve the dose precision and accuracy aimed for in clinical dose verification. Here, the introduction ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2712042
更新日期:2007-04-01 00:00:00
abstract:PURPOSE:High-Z material in computed tomography (CT) yields metal artifacts that degrade image quality and may cause substantial errors in dose calculation. This study couples a metal artifact reduction (MAR) algorithm with enhanced 16-bit depth (vs standard 12-bit) to quantify potential gains in image quality and dosim...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4805102
更新日期:2013-06-01 00:00:00
abstract:PURPOSE:In radiotherapy (RT) based on magnetic resonance imaging (MRI) as the only modality, the information on electron density must be derived from the MRI scan by creating a so-called pseudo computed tomography (pCT). This is a nontrivial task, since the voxel-intensities in an MRI scan are not uniquely related to e...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4914158
更新日期:2015-04-01 00:00:00
abstract::A method for finding optimal primary fluence profiles for multiple field external beam radiation therapy techniques has been developed using a radiobiologically based objective function that quantifies the probability of achieving complication-free tumor control, P+. The objective function P+ has the valuable property...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596971
更新日期:1993-07-01 00:00:00
abstract:PURPOSE:Deformable image registration (DIR) is often validated based on a distance-to-agreement (DTA) criterion of automatically propagated anatomical landmarks that were manually identified. Due to human observer variability, however, the performance of the registration method is diluted. The purpose of this study was...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4760990
更新日期:2012-11-01 00:00:00
abstract::An automated technique for the alignment of right and left breast images has been developed for use in the computerized analysis of bilateral breast images. In this technique, the breast region is first identified in each digital mammogram by use of histogram analysis and morphological filtering operations. The anteri...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597307
更新日期:1994-03-01 00:00:00
abstract:PURPOSE:MR-guided radiation therapy (RT) offers unparalleled soft tissue contrast for localization and target tracking. However, MRI distortions may be detrimental to high precision RT. This work characterizes the gradient nonlinearity (GNL) and total distortions over the first year of clinical operation of a 0.35T MR-...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13467
更新日期:2019-05-01 00:00:00
abstract::Compared with slice-by-slice approaches for SPECT reconstruction, three-dimensional iterative methods provide a more accurate physical model and an improved SPECT image. Clinical application of these methods, however, is limited primarily to their computational demands. This paper investigates the methods for approxim...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598030
更新日期:1997-09-01 00:00:00
abstract:PURPOSE:It is very important for calculation of clinical indices and diagnosis to detect thyroid nodules from ultrasound images. However, this task is a challenge mainly due to heterogeneous thyroid nodules with distinct components are similar to background in ultrasound images. In this study, we employ cascade deep co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12134
更新日期:2017-05-01 00:00:00
abstract:PURPOSE:To investigate whether building a knowledge-based planning (KBP) model with prostate bed plans constructed from constrained hierarchical optimization (CHO) would result in more efficient model construction with more consistent output than a model built using plans from a traditional, trial-and-error-based optim...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13163
更新日期:2018-10-01 00:00:00
abstract:PURPOSE:The quality of tomographic images is directly affected by the system model being used in image reconstruction. An accurate system matrix is desirable for high-resolution image reconstruction, but it often leads to high computation cost. In this work the authors present a maximum a posteriori reconstruction algo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3284980
更新日期:2010-02-01 00:00:00
abstract::Breast density is a strong predictor of the failure of mammography screening to detect breast cancer and is a strong predictor of the risk of developing breast cancer. The many imaging options that are now available for imaging dense breasts show great promise, but there is still the question of determining which wome...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.4935141
更新日期:2015-12-01 00:00:00
abstract::Administration of x-ray contrast agents during heart catheterization examination increases the absorbed radiation dose in tissue. To estimate the dose absorbed by the blood of children undergoing diagnostic heart catheterization and angiocardiography, a number of measurements and calculations were conducted. First, en...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594613
更新日期:1979-11-01 00:00:00
abstract::To improve beam penetration into a head allowing the treatment of deeper seated tumors, two neutron collimators were built sequentially and tested for use in the clinical boron neutron capture therapy (BNCT) program at the epithermal neutron irradiation facility of the Brookhaven Medical Research Reactor. The collimat...
journal_title:Medical physics
pub_type: 临床试验,杂志文章
doi:10.1118/1.597772
更新日期:1996-12-01 00:00:00
abstract:PURPOSE:This work is to evaluate the effects of Compton current generation in three small-volume ionization chambers on measured beam characteristics for electron fields. METHODS:Beam scans were performed using Exradin A16, A26, and PTW 31014 microchambers. Scans with varying chamber components shielded were performed...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4929555
更新日期:2015-10-01 00:00:00