A simple magnetic spectrometer for radiotherapy electron beams.

Abstract:

:A small, lightweight, single-focusing magnetic spectrometer was designed, assembled, and tested for analysis of electron beams from radiotherapy electron linacs. The objective was to develop a low cost, simple device that could be easily replicated in other medical centers, and to demonstrate the practicality of individual electron counting for precise analysis of electron spectra. Two methods of spectroscopy have been developed. One method consists of counting electrons individually as a function of magnetic field setting. Electrons are deflected through 90 degrees in the magnetic spectrometer, through an exit slit, and into a scintillation detector. A second method consists of recording the complete spectrum of electron energies from the accelerator on a strip of film at a single magnetic field setting. A critical design element is the 10-cm long collimator for electrons entering the magnet gap, with defining apertures and scraper slits. The spectrometer's cleanliness of transmission, energy calibration, and resolution were all tested at 10 and 16 MeV using the nearly monoenergetic electron beam of the accelerator at the National Research Council of Canada (NRCC). These accelerator tests, and also Monte Carlo trajectory simulations, both show that contamination of the transmitted spectrum due to scattered or knock-on electrons is negligible. Low-energy characteristics were tested using a 90Sr + 90Y beta-particle source. The energy calibration of the 90 degree spectrometer mode was based on mapping the magnetic field and also electron trajectory computer simulations. That calibration agrees with the NRCC's own calibrated scale to 0.8% for the single-particle counting method and to 1.3% for the film method. The energy resolution was measured to be 2% at 10 MeV, which is adequate for radiotherapy linac measurements. The acceptance half angle is 0.5 degrees or less, depending on the aperture size, which is adequate for electron angular distribution measurements within the forward cone of the electron beam. Used with film, the spectrometer is a simple, accurate, and highly transportable device for measuring radiotherapy electron energy spectra.

journal_name

Med Phys

journal_title

Medical physics

authors

Deasy JO,Almond PR,McEllistrem MT,Ross CK

doi

10.1118/1.597271

subject

Has Abstract

pub_date

1994-11-01 00:00:00

pages

1703-14

issue

11

eissn

0094-2405

issn

2473-4209

journal_volume

21

pub_type

杂志文章
  • In-vivo rectal dose measurements with diodes to avoid misadministrations during intracavitary high dose rate brachytherapy for carcinoma of the cervix.

    abstract::Our purpose in this paper is to present an in vivo dosimetry program designed both for measuring the rectal dose and for avoiding misadministrations in gynecological intracavitary implants. A device containing an energy compensated diode was specially designed for these measurements. Our calibration procedure as well ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598598

    authors: Alecu R,Alecu M

    更新日期:1999-05-01 00:00:00

  • Dosimetric verification of IMAT delivery with a conventional EPID system and a commercial portal dose image prediction tool.

    abstract:PURPOSE:The electronic portal imaging device (EPID) is a system for checking the patient setup; as a result of its integration with the linear accelerator and software customized for dosimetry, it is increasingly used for verification of the delivery of fixed-field intensity-modulated radiation therapy (IMRT). In order...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3271107

    authors: Iori M,Cagni E,Paiusco M,Munro P,Nahum AE

    更新日期:2010-01-01 00:00:00

  • Backscatter factors in the mammographic energy range.

    abstract::Backscatter factors for kVps and half-value layers typical of mammographic beams have been determined as a function of beam diameter and half-value layer. The method utilized thin TLD-100 chips with the scattering medium alternately present and absent. Results indicate that the field-size dependence of the backscatter...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594312

    authors: Dubuque GL,Cacak RK,Hendee WR

    更新日期:1977-09-01 00:00:00

  • Penalized likelihood fluence optimization with evolutionary components for intensity modulated radiation therapy treatment planning.

    abstract::A novel iterative penalized likelihood algorithm with evolutionary components for the optimization of beamlet fluences for intensity modulated radiation therapy (IMRT) is presented. This algorithm is designed to be flexible in terms of the objective function and automatically escalates dose, as long as the objective f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1773631

    authors: Baydush AH,Marks LB,Das SK

    更新日期:2004-08-01 00:00:00

  • Stereotactic mammography imaging combined with 3D US imaging for image guided breast biopsy.

    abstract::Stereotactic X-ray mammography (SM) and ultrasound (US) guidance are both commonly used for breast biopsy. While SM provides three-dimensional (3D) targeting information and US provides real-time guidance, both have limitations. SM is a long and uncomfortable procedure and the US guided procedure is inherently two dim...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2794175

    authors: Surry KJ,Mills GR,Bevan K,Downey DB,Fenster A

    更新日期:2007-11-01 00:00:00

  • Future of medical physics: Real-time MRI-guided proton therapy.

    abstract::With the recent clinical implementation of real-time MRI-guided x-ray beam therapy (MRXT), attention is turning to the concept of combining real-time MRI guidance with proton beam therapy; MRI-guided proton beam therapy (MRPT). MRI guidance for proton beam therapy is expected to offer a compelling improvement to the c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12371

    authors: Oborn BM,Dowdell S,Metcalfe PE,Crozier S,Mohan R,Keall PJ

    更新日期:2017-08-01 00:00:00

  • SU-E-J-115: Graticule for Verification of Treatment Position in Neutron Therapy.

    abstract:PURPOSE:Until recently the treatment verification for patients undergoing fast neutron therapy at our facility was accomplished through a combination of neutron beam portal films aligned with a graticule mounted on an orthronormal x-ray tube. To eliminate uncertainty with respect to the relative positions of the x-ray ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734951

    authors: Halford R,Snyder M

    更新日期:2012-06-01 00:00:00

  • A 4 x 500 mm2 cloverleaf detector system for in vivo bone lead measurement.

    abstract::A 4 x 500 mm2 "cloverleaf" low energy germanium detector array has been assembled for the purpose of in vivo bone lead measurement through x-ray fluorescence. Using 109Cd as an exciting source, results are reported from a leg phantom simulating measurement of lead in a human tibia. For high activity (4.0-4.4 GBq) and ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2436973

    authors: Fleming DE,Mills CE

    更新日期:2007-03-01 00:00:00

  • Comparison of planned dose on different CT image sets to four-dimensional Monte Carlo dose recalculation using the patient's actual breathing trace for lung stereotactic body radiation therapy.

    abstract:PURPOSE:The need for four-dimensional (4D) treatment planning becomes indispensable when it comes to radiation therapy for moving tumors in the thoracic and abdominal regions. The primary purpose of this study is to combine the actual breathing trace during each individual treatment fraction with the Linac's log file i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13579

    authors: Freislederer P,von Münchow A,Kamp F,Heinz C,Gerum S,Corradini S,Söhn M,Reiner M,Roeder F,Floca R,Alber M,Belka C,Parodi K

    更新日期:2019-07-01 00:00:00

  • Use of a dynamic rangeshifter for modifying the depth-dose distributions of negative pions.

    abstract::In order to use negative pions for the treatment of large deep-seated tumors in radiotherapy, it is necessary to produce depth-dose distributions tailored to specific shapes. We present here a method of beam shaping which utilizes a fluid-filled piston having a programmable, computer-controlled, time-dependent thickne...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594313

    authors: Amols HI,Liska DJ,Halbig J

    更新日期:1977-09-01 00:00:00

  • Evaluation of a compact multicontrast and multiresolution X-ray phase contrast edge illumination system for small animal imaging.

    abstract:PURPOSE:In this work the performance of a compact multiresolution and multicontrast x-ray phase system based on edge illumination is investigated. It has been designed for small animal imaging and with a limited footprint for ease of deployment in laboratories. METHODS:The presented edge illumination system is based o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14553

    authors: Massimi L,Meganck JA,Towns R,Olivo A,Endrizzi M

    更新日期:2020-10-27 00:00:00

  • Displacement and strain estimation for evaluation of arterial wall stiffness using a familial hypercholesterolemia swine model of atherosclerosis.

    abstract:PURPOSE:To track variations in the deformation of the arterial wall noninvasively by estimating the accumulated displacement and strain over a cardiac cycle may provide useful indicators of vascular health. METHODS:In this paper, we propose an approach to track a region of interest (ROI) locally and estimate arterial ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4722746

    authors: Ge W,Krueger CG,Weichmann A,Shanmuganayagam D,Varghese T

    更新日期:2012-07-01 00:00:00

  • COMS eye plaque brachytherapy dosimetry simulations for 103Pd, 125I, and 131Cs.

    abstract::Monte Carlo (MC) simulations were performed to estimate brachytherapy dose distributions for Collaborative Ocular Melanoma Study (COMS) eye plaques. Brachytherapy seed models 200, 6711, and CS-1 Rev2 carrying 103Pd, 125I, and 131Cs radionuclides, respectively, were modeled and benchmarked against previously published ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2940604

    authors: Melhus CS,Rivard MJ

    更新日期:2008-07-01 00:00:00

  • Experimental implementation of a joint statistical image reconstruction method for proton stopping power mapping from dual-energy CT data.

    abstract:PURPOSE:To experimentally commission a dual-energy CT (DECT) joint statistical image reconstruction (JSIR) method, which is built on a linear basis vector model (BVM) of material characterization, for proton stopping power ratio (SPR) estimation. METHODS:The JSIR-BVM method builds on the relationship between the energ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13287

    authors: Zhang S,Han D,Williamson JF,Zhao T,Politte DG,Whiting BR,O'Sullivan JA

    更新日期:2019-01-01 00:00:00

  • Dual-storage phosphor proton therapy dosimetry: simultaneous quantification of dose and linear energy transfer.

    abstract:PURPOSE:To investigate the feasibility of using the high Zeff storage phosphor material BaFBrI:Eu2+ in conjunction with the low Zeff storage phosphor material KCl:Eu2+ for simultaneous proton dose and linear energy transfer (LET) measurements by 1) measuring the fundamental optical and dosimetric properties of BaFBrI:E...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14748

    authors: Setianegara J,Mazur TR,Yang D,Li HH

    更新日期:2021-02-01 00:00:00

  • Energy spectrum based calculation of the half and the tenth value layers for brachytherapy sources using a semiempirical parametrized mass attenuation coefficient formulism.

    abstract::As different types of radionuclides (e.g., 131Cs source) are introduced for clinical use in brachytherapy, the question is raised regarding whether a relatively simple method exists for the derivation of values of the half value layer (HVL) or the tenth value layer (TVL). For the radionuclide that has been clinically ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2905356

    authors: Yue NJ

    更新日期:2008-06-01 00:00:00

  • Direct data link between a CT scanner and a radiation treatment planning system.

    abstract::A direct data link between a CT scanner and a radiation treatment planning system has been developed. The link transmits the data serially over a coaxial cable using the pseudo-paper-tape punch and reader (serial PIO) interfaces. The data transmission rate with error-check is approximately 25,000 8-bit bytes/s. This t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594536

    authors: Abel RN,Buhler LA,Chu WT,Slater JM,Neilsen IR,Zimmerman DC

    更新日期:1979-09-01 00:00:00

  • Low dose positron emission tomography emulation from decimated high statistics: A clinical validation study.

    abstract:PURPOSE:The fundamental nature of positron emission tomography (PET), as an event detection system, provides some flexibility for data handling, including retrospective data manipulation. The reorganization of acquisition data allows the emulation of new scans arising from identical radiotracer spatial distributions, b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13517

    authors: Schaefferkoetter J,Nai YH,Reilhac A,Townsend DW,Eriksson L,Conti M

    更新日期:2019-06-01 00:00:00

  • Planning strategies in volumetric modulated are therapy for breast.

    abstract:PURPOSE:In breast radiotherapy with intensity modulation, it is a well established practice to extend the dose fluence outside the limit of the body contour to account for small changes in size and position of the target and the rest of the tissues due to respiration or to possible oedema. A simple approach is not appl...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3598442

    authors: Giorgia N,Antonella F,Alessandro C,Eugenio V,Luca C

    更新日期:2011-07-01 00:00:00

  • Evaluation of carbon nanotube x-ray source array for stationary head computed tomography.

    abstract:PURPOSE:Stationary computed tomography (s-CT) conceptually offers several advantages over existing rotating gantry-based CT. Over the last 40 yr, s-CT has been investigated using different technological approaches. We are developing a s-CT system specifically for head/brain imaging using carbon nanotube (CNT)-based fie...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14696

    authors: Spronk D,Luo Y,Inscoe CR,Lee YZ,Lu J,Zhou O

    更新日期:2020-12-31 00:00:00

  • Electron dose calculation using multiple-scattering theory. A. Gaussian multiple-scattering theory.

    abstract::This article is the first in a series on the calculation of electron dose using multiple-scattering theory. In it we develop a unified theory, which we term Gaussian multiple-scattering theory, starting from a number of contributions already in the literature: the Fermi-Eyges multiple-scattering theory, the Yang path ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596166

    authors: Jette D

    更新日期:1988-03-01 00:00:00

  • ITAR: A modified TAR method to determine depth dose distribution for an ophthalmic device that performs kilovoltage x-ray pencil-beam stereotaxy.

    abstract:PURPOSE:New technology has been developed to treat age-related macular degeneration (AMD) using 100 kVp pencil-beams that enter the patient through the radio-resistant sclera with a depth of interest between 1.6 and 2.6 cm. Measurement of reference and relative dose in a kilovoltage x-ray beam with a 0.42 cm diameter f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4863482

    authors: Hanlon J,Chell E,Firpo M,Koruga I

    更新日期:2014-02-01 00:00:00

  • Mitigating differential baseline shifts in locally advanced lung cancer patients using an average anatomy model.

    abstract:BACKGROUND AND PURPOSE:Differential baseline shifts between primary tumor and involved lymph nodes in locally advanced lung cancer patients compromise the accuracy of radiotherapy. The purpose of this study was to evaluate the performance of an average anatomy model (AAM) derived from repeat imaging and deformable regi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12271

    authors: Abdoli M,Van Kranen SR,Stankovic U,Rossi MMG,Belderbos JSA,Sonke JJ

    更新日期:2017-07-01 00:00:00

  • A voxel-based multiscale model to simulate the radiation response of hypoxic tumors.

    abstract:PURPOSE:In radiotherapy, it is important to predict the response of tumors to irradiation prior to the treatment. This is especially important for hypoxic tumors, which are known to be highly radioresistant. Mathematical modeling based on the dose distribution, biological parameters, and medical images may help to impr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4903298

    authors: Espinoza I,Peschke P,Karger CP

    更新日期:2015-01-01 00:00:00

  • Predicting radiotherapy-induced cardiac perfusion defects.

    abstract::The purpose of this work is to compare the efficacy of mathematical models in predicting the occurrence of radiotherapy-induced left ventricular perfusion defects assessed using single-photon emission computed tomography (SPECT). The basis of this study is data from 73 left-sided breast/ chestwall patients treated wit...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1823571

    authors: Das SK,Baydush AH,Zhou S,Miften M,Yu X,Craciunescu O,Oldham M,Light K,Wong T,Blazing M,Borges-Neto S,Dewhirst MW,Marks LB

    更新日期:2005-01-01 00:00:00

  • A pencil beam algorithm for magnetic resonance image-guided proton therapy.

    abstract:PURPOSE:The feasibility of magnetic resonance image (MRI)-based proton therapy is based, among several other factors, on the implementation of appropriate extensions on current dose calculation methods. This work aims to develop a pencil beam algorithm (PBA) for dose calculation of proton beams within magnetic field re...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12854

    authors: Padilla-Cabal F,Georg D,Fuchs H

    更新日期:2018-05-01 00:00:00

  • Updated breast CT dose coefficients (DgNCT ) using patient-derived breast shapes and heterogeneous fibroglandular distributions.

    abstract:PURPOSE:The purpose of this work was to generate uncompressed heterogeneous breast phantom models using size-dependent fibroglandular distributions derived from a large cohort of breast CT (bCT) datasets, and to compare differences in normalized glandular dose coefficients for bCT "DgNCT " when the realistic heterogene...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13391

    authors: Hernandez AM,Becker AE,Boone JM

    更新日期:2019-03-01 00:00:00

  • Integration of microwave tomography with magnetic resonance for improved breast imaging.

    abstract:PURPOSE:Breast magnetic resonance imaging is highly sensitive but not very specific for the detection of breast cancer. Opportunities exist to supplement the image acquisition with a more specific modality provided the technical challenges of meeting space limitations inside the bore, restricted breast access, and elec...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4820361

    authors: Meaney PM,Golnabi AH,Epstein NR,Geimer SD,Fanning MW,Weaver JB,Paulsen KD

    更新日期:2013-10-01 00:00:00

  • Liver segmentation in contrast enhanced CT data using graph cuts and interactive 3D segmentation refinement methods.

    abstract:PURPOSE:Liver segmentation is an important prerequisite for the assessment of liver cancer treatment options like tumor resection, image-guided radiation therapy (IGRT), radiofrequency ablation, etc. The purpose of this work was to evaluate a new approach for liver segmentation. METHODS:A graph cuts segmentation metho...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3682171

    authors: Beichel R,Bornik A,Bauer C,Sorantin E

    更新日期:2012-03-01 00:00:00

  • Correcting and reweighting false label masks in brain tumor segmentation.

    abstract:PURPOSE:Recently, brain tumor segmentation has made important progress. However, the quality of manual labels plays an important role in the performance, while in practice, it could vary greatly and in turn could substantially mislead the learning process and decrease the accuracy. We need to design a mechanism to comb...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14480

    authors: Cheng G,Ji H,He L

    更新日期:2020-09-24 00:00:00