Displacement and strain estimation for evaluation of arterial wall stiffness using a familial hypercholesterolemia swine model of atherosclerosis.

Abstract:

PURPOSE:To track variations in the deformation of the arterial wall noninvasively by estimating the accumulated displacement and strain over a cardiac cycle may provide useful indicators of vascular health. METHODS:In this paper, we propose an approach to track a region of interest (ROI) locally and estimate arterial stiffness variation in a familial hypercholesterolemic swine model of spontaneous atherosclerosis that allows for systematic and reproducible study of progression of the disease mechanism. RESULTS:Strain and displacement indices may be derived from the variations of the accumulated displacement and accumulated strain (obtained from the gradient of the accumulated displacement) over a cardiac cycle to predict not only the likelihood of developing vascular diseases, but also the sites where they may occur. Currently, an ROI thickness value of less than one mm within the arterial wall is necessary for the axial accumulated displacement and strain to obtain reproducible estimates. CONCLUSIONS:Accumulated axial displacement and strain estimation on the artery wall shown in this paper indicate the repeatability of these measurements over several cardiac cycles and over five familial hypercholesterolemic swine. Our results also demonstrate the need for a small region of interest within the arterial walls for accurate and robust estimates of arterial function.

journal_name

Med Phys

journal_title

Medical physics

authors

Ge W,Krueger CG,Weichmann A,Shanmuganayagam D,Varghese T

doi

10.1118/1.4722746

subject

Has Abstract

pub_date

2012-07-01 00:00:00

pages

4483-92

issue

7

eissn

0094-2405

issn

2473-4209

journal_volume

39

pub_type

杂志文章
  • An interprojection sensor fusion approach to estimate blocked projection signal in synchronized moving grid-based CBCT system.

    abstract:PURPOSE:A preobject grid can reduce and correct scatter in cone beam computed tomography (CBCT). However, half of the signal in each projection is blocked by the grid. A synchronized moving grid (SMOG) has been proposed to acquire two complimentary projections at each gantry position and merge them into one complete pr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4937934

    authors: Zhang H,Ren L,Kong V,Giles W,Zhang Y,Jin JY

    更新日期:2016-01-01 00:00:00

  • Classification of breast lesions using segmented quantitative ultrasound maps of homodyned K distribution parameters.

    abstract:PURPOSE:Statistical modeling of an ultrasound backscattered echo envelope is used for tissue characterization. However, in the presence of complex structures within the analyzed area, estimation of parameters is disturbed and unreliable, e.g., in the case of breast tumor classification. In order to improve the differen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4962928

    authors: Byra M,Nowicki A,Wróblewska-Piotrzkowska H,Dobruch-Sobczak K

    更新日期:2016-10-01 00:00:00

  • Updated breast CT dose coefficients (DgNCT ) using patient-derived breast shapes and heterogeneous fibroglandular distributions.

    abstract:PURPOSE:The purpose of this work was to generate uncompressed heterogeneous breast phantom models using size-dependent fibroglandular distributions derived from a large cohort of breast CT (bCT) datasets, and to compare differences in normalized glandular dose coefficients for bCT "DgNCT " when the realistic heterogene...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13391

    authors: Hernandez AM,Becker AE,Boone JM

    更新日期:2019-03-01 00:00:00

  • The use of modified single pencil beam dose kernels to improve IMRT dose calculation accuracy.

    abstract::Intensity modulated radiation therapy (IMRT) is used to deliver highly conformal radiation doses to tumors while sparing nearby sensitive tissues. Discrepancies between calculated and measured dose distributions have been reported for regions of high dose gradients corresponding to complex radiation fluence patterns. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1812851

    authors: Bergman AM,Otto K,Duzenli C

    更新日期:2004-12-01 00:00:00

  • The effect of coupling materials on specific absorption rate distributions at 915 MHz.

    abstract::Deionized water is commonly used to couple microwave applicators to the patient surface in the administration of local hyperthermia. Profiles of the specific absorption rate (SAR) at 1-cm depth show that deionized water coupling significantly distorts the SAR distributions of the Clini-Therm 915-MHz 10 X 10 and 15 X 1...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595881

    authors: Waterman FM,Nerlinger RE

    更新日期:1986-05-01 00:00:00

  • Variability of tumor area measurements for response assessment in malignant pleural mesothelioma.

    abstract:PURPOSE:The measurement of malignant pleural mesothelioma is critical to the assessment of tumor response to therapy. Current response assessment standards utilize summed linear measurements acquired on three computed tomography (CT) sections. The purpose of this study was to evaluate manual area measurements as an alt...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4810940

    authors: Labby ZE,Straus C,Caligiuri P,MacMahon H,Li P,Funaki A,Kindler HL,Armato SG 3rd

    更新日期:2013-08-01 00:00:00

  • Absolute x-ray dosimetry on a synchrotron medical beam line with a graphite calorimeter.

    abstract:PURPOSE:The absolute dose rate of the Imaging and Medical Beamline (IMBL) on the Australian Synchrotron was measured with a graphite calorimeter. The calorimetry results were compared to measurements from the existing free-air chamber, to provide a robust determination of the absolute dose in the synchrotron beam and p...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4870387

    authors: Harty PD,Lye JE,Ramanathan G,Butler DJ,Hall CJ,Stevenson AW,Johnston PN

    更新日期:2014-05-01 00:00:00

  • Experimental evaluation of the dosimetric impact of intrafraction prostate rotation using film measurement with a 6DoF robotic arm.

    abstract:PURPOSE:Tumor motion during radiotherapy can cause a reduction in target dose coverage and an increase in healthy tissue exposure. Tumor motion is not strictly translational and often exhibits complex six degree-of-freedom (6DoF) translational and rotational motion. Although the dosimetric impact of prostate tumor tran...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14502

    authors: Shi K,Dipuglia A,Booth J,Alnaghy S,Kyme A,Keall P,Nguyen DT

    更新日期:2020-12-01 00:00:00

  • Use of 48Ca as a stable isotope tracer analyzed by proton activation.

    abstract::The use of the stable isotope 48Ca as a tracer in biological systems has been studied. Determination of 48Ca concentrations in samples was accomplished by proton activation via the (p,n) reaction with subsequent measurement of gamma-ray spectra from 44-h 48Sc and 4-h 44Sc. With protons of about 5.5 MeV and a Ge(Li) ga...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594303

    authors: Edwards FM,Kraushaar JJ,Ristinen RA,Rudolph H

    更新日期:1977-01-01 00:00:00

  • Single shot MR tagging to quantify local tissue deformation during MRI-guided needle interventions: a feasibility study.

    abstract:PURPOSE:In MRI-guided needle interventions, such as biopsies and brachytherapy, tissue deformation caused by needle movement may result in localization errors and thus hamper the outcome of the procedure. Monitoring the local tissue deformation provides the ability to compensate for it, e.g., by increasing the needle i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3633906

    authors: van den Bosch MR,de Leeuw H,Zwanenburg JJ,Lagendijk JJ,Moerland MA

    更新日期:2011-10-01 00:00:00

  • Accuracy of deformable image registration on magnetic resonance images in digital and physical phantoms.

    abstract:PURPOSE:Accurate deformable image registration is necessary for longitudinal studies. The error associated with commercial systems has been evaluated using computed tomography (CT). Several in-house algorithms have been evaluated for use with magnetic resonance imaging (MRI), but there is still relatively little inform...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12406

    authors: Ger RB,Yang J,Ding Y,Jacobsen MC,Fuller CD,Howell RM,Li H,Jason Stafford R,Zhou S,Court LE

    更新日期:2017-10-01 00:00:00

  • A field-shaping multi-well avalanche detector for direct conversion amorphous selenium.

    abstract:PURPOSE:A practical detector structure is proposed to achieve stable avalanche multiplication gain in direct-conversion amorphous selenium radiation detectors. METHODS:The detector structure is referred to as a field-shaping multi-well avalanche detector. Stable avalanche multiplication gain is achieved by eliminating...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1118/1.4769110

    authors: Goldan AH,Zhao W

    更新日期:2013-01-01 00:00:00

  • Acuros CTS: A fast, linear Boltzmann transport equation solver for computed tomography scatter - Part I: Core algorithms and validation.

    abstract:PURPOSE:To describe Acuros® CTS, a new software tool for rapidly and accurately estimating scatter in x-ray projection images by deterministically solving the linear Boltzmann transport equation (LBTE). METHODS:The LBTE describes the behavior of particles as they interact with an object across spatial, energy, and dir...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12850

    authors: Maslowski A,Wang A,Sun M,Wareing T,Davis I,Star-Lack J

    更新日期:2018-05-01 00:00:00

  • Technical Note: Evaluation of a 160-mm/256-row CT scanner for whole-heart quantitative myocardial perfusion imaging.

    abstract:PURPOSE:The authors investigated the performance of a recently introduced 160-mm/256-row CT system for low dose quantitative myocardial perfusion (MP) imaging of the whole heart. This platform is equipped with a gantry capable of rotating at 280 ms per full cycle, a second generation of adaptive statistical iterative r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4957389

    authors: So A,Imai Y,Nett B,Jackson J,Nett L,Hsieh J,Wisenberg G,Teefy P,Yadegari A,Islam A,Lee TY

    更新日期:2016-08-01 00:00:00

  • Automated registration of large deformations for adaptive radiation therapy of prostate cancer.

    abstract::Available deformable registration methods are often inaccurate over large organ variation encountered, for example, in the rectum and bladder. The authors developed a novel approach to accurately and effectively register large deformations in the prostate region for adaptive radiation therapy. A software tool combinin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3095777

    authors: Godley A,Ahunbay E,Peng C,Li XA

    更新日期:2009-04-01 00:00:00

  • SU-E-T-382: An Analysis of VMAT Monthly Quality Assurance.

    abstract:PURPOSE:The purpose of this study is to quantify the change in monthly VMAT quality assurance (QA) and determine the tests to maintain consistent delivery with a baseline. METHODS:VMAT monthly QA has been performed for over 14 months on two Elekta Synergy LINACs. A baseline was established at acceptance and the monthl...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735470

    authors: Stenbeck J,Oves S,Gebreamlak W,Alkhatib H

    更新日期:2012-06-01 00:00:00

  • Explicit optimization of plan quality measures in intensity-modulated radiation therapy treatment planning.

    abstract:PURPOSE:To formulate convex planning objectives of treatment plan multicriteria optimization with explicit relationships to the dose-volume histogram (DVH) statistics used in plan quality evaluation. METHODS:Conventional planning objectives are designed to minimize the violation of DVH statistics thresholds using pena...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12146

    authors: Engberg L,Forsgren A,Eriksson K,Hårdemark B

    更新日期:2017-06-01 00:00:00

  • A phantom evaluation of Sentinel(™), a commercial laser/camera surface imaging system for patient setup verification in radiotherapy.

    abstract:PURPOSE:The aim of this study is to investigate the performance of Sentinel(™), a patient setup verification device based on a laser/camera system, when used on rigid-body phantoms. METHODS:The Sentinel system consists of a scanner unit, containing the laser and the camera, and surface-matching registration software. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3675973

    authors: Pallotta S,Marrazzo L,Ceroti M,Silli P,Bucciolini M

    更新日期:2012-02-01 00:00:00

  • Vessel size measurements in angiograms: manual measurements.

    abstract::Vessel size measurement is perhaps the most often performed quantitative analysis in diagnostic and interventional angiography. Although automated vessel sizing techniques are generally considered to have good accuracy and precision, we have observed that clinicians rarely use these techniques in standard clinical pra...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1562491

    authors: Hoffmann KR,Dmochowski J,Nazareth DP,Miskolczi L,Nemes B,Gopal A,Wang Z,Rudin S,Bednarek DR

    更新日期:2003-04-01 00:00:00

  • Calculations of two-dimensional electric field and potential distributions around electrodes in conducting media.

    abstract::Tumor cells can be killed by heating to 42.5 degrees C. It is convenient to localize heating by passing electric current at 500 kHz through tissue between a pair of electrodes. It is desirable to determine, for a given electrode-tissue configuration, what the resulting field and, therefore, current distribution will b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594235

    authors: Hutson RL

    更新日期:1976-07-01 00:00:00

  • The water-equivalence of phantom materials for 90Sr-90Y beta particles.

    abstract::Intravascular brachytherapy requires that the dose be specified within millimeters of the source. High dose gradients near brachytherapy sources require that the source-detector distance be accurately known for dosimetry purposes. Solid phantoms can be designed to accommodate these stringent requirements. This study r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1376176

    authors: Buckley LA,Thomadsen BR,DeWerd LA

    更新日期:2001-06-01 00:00:00

  • Medical applications of shortwave FM radar: remote monitoring of cardiac and respiratory motion.

    abstract:PURPOSE:This article introduces the use of low power continuous wave frequency modulated radar for medical applications, specifically for remote monitoring of vital signs in patients. METHODS:Gigahertz frequency radar measures the electromagnetic wave signal reflected from the surface of a human body and from tissue b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3267038

    authors: Mostov K,Liptsen E,Boutchko R

    更新日期:2010-03-01 00:00:00

  • TU-E-217BCD-10: Dose Reduction in Digital Breast Tomosynthesis with the Dose Reduction Prior Image Constrained Compressed Sensing (DR-PICCS) Algorithm.

    abstract:PURPOSE:To reduce image noise and radiation dose in Digital Breast Tomosynthesis (DBT) reconstructions. METHODS:A retrospective study was performed on clinical data sets acquired at a normal dose with Hologic Selenia Dimensions DBT systems. The Prior Image Constrained Compressed Sensing (PICCS) algorithm was used to r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735982

    authors: Garrett J,Tang J,Zhang Y,Ruth C,Jing Z,Chen GH

    更新日期:2012-06-01 00:00:00

  • Verification of absorbed dose determined with plane-parallel chambers in clinical electron beams following AAPM Task Group 39 protocol using ferrous sulphate dosimetry.

    abstract::The absorbed dose values determined with the Exradin and PTW-Markus plane-parallel chambers were compared to the values obtained with the ferrous sulphate dosimetry for a number of the Philips SL25 and the Therac 20 electron beams. For the plane-parallel chambers, the cavity-gas calibration factor Ngaspp, was derived ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597800

    authors: Xu Z,Li H,Almond PR,Guan TY

    更新日期:1996-03-01 00:00:00

  • Off-axis beam quality change in linear accelerator x-ray beams.

    abstract::The effective energy of the x-ray beam from linear accelerators changes as a function of the position in the beam due to nonuniform filtration by the flattening filter. In this work, the transmittance through a water column was measured in good geometry and the beam quality characterized in units of HVL in water. Meas...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594677

    authors: Hanson WF,Berkley LW,Peterson M

    更新日期:1980-03-01 00:00:00

  • Mammogram synthesis using a three-dimensional simulation. III. Modeling and evaluation of the breast ductal network.

    abstract::A method is proposed for realistic simulation of the breast ductal network as part of a computer three-dimensional (3-D) breast phantom. The ductal network is simulated using tree models. Synthetic trees are generated based upon a description of ductal branching by ramification matrices (R matrices), whose elements re...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1586453

    authors: Bakic PR,Albert M,Brzakovic D,Maidment AD

    更新日期:2003-07-01 00:00:00

  • Choice of material for HVL measurements in megavoltage x-ray beams.

    abstract::The relative sensitivity of the half-value layer (HVL) method as a quality index for megavoltage x-ray beams is examined by theoretical calculation and experimental measurements for 4-, 6-, 10-, and 25-MV x-ray beams. It is shown that lower atomic number materials are more sensitive to beam quality changes than higher...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595794

    authors: Meli JA,Nath R

    更新日期:1985-01-01 00:00:00

  • Evaluation of CT-based lean-body SUV.

    abstract:PURPOSE:The authors introduce a novel method for defining standardized uptake values (SUVs) in PET∕CT based on routinely collected CT data. The goal of the study is to reduce, if possible, the variability of SUV in a heterogeneous population. Two well established methods for defining SUV are based on body weight (BW) a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4816656

    authors: Hamill JJ,Sunderland JJ,LeBlanc AK,Kojima CJ,Wall J,Martin EB

    更新日期:2013-09-01 00:00:00

  • Compensator models for fluence field modulated computed tomography.

    abstract:PURPOSE:Fluence field modulated computed tomography (FFMCT) presents a novel approach for acquiring CT images, whereby a patient model guides dynamically changing fluence patterns in an attempt to achieve task-based, user-prescribed, regional variations in image quality, while also controlling dose to the patient. This...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4829513

    authors: Bartolac S,Jaffray D

    更新日期:2013-12-01 00:00:00

  • Specific recommendations for accurate and direct use of PET-CT in PET guided radiotherapy for head and neck sites.

    abstract:PURPOSE:To provide specific experience-based guidance and recommendations for centers wishing to develop, validate, and implement an accurate and efficient process for directly using positron emission tomography-computed tomography (PET-CT) for the radiotherapy planning of head and neck cancer patients. METHODS:A PET-...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4867856

    authors: Thomas CM,Pike LC,Hartill CE,Baker S,Woods E,Convery DJ,Greener AG

    更新日期:2014-04-01 00:00:00