Experimental evaluation of the dosimetric impact of intrafraction prostate rotation using film measurement with a 6DoF robotic arm.

Abstract:

PURPOSE:Tumor motion during radiotherapy can cause a reduction in target dose coverage and an increase in healthy tissue exposure. Tumor motion is not strictly translational and often exhibits complex six degree-of-freedom (6DoF) translational and rotational motion. Although the dosimetric impact of prostate tumor translational motion is well investigated, the dosimetric impact of 6DoF motion has only been studied with simulations or dose reconstruction. This study aims to experimentally quantify the dose error caused by 6DoF motion. The experiment was designed to test the hypothesis that 6DoF motion would cause larger dose errors than translational motion alone through gamma analyses of two-dimensional film measurements. METHODS:Four patient-measured intrafraction prostate motion traces and four VMAT 7.25 Gy/Fx SBRT treatment plans were selected for the experiment. The traces represented typical motion patterns, including small-angle rotations (<4°), transient movement, persistent excursion, and erratic rotations (>6°). Gafchromic film was placed inside a custom-designed phantom, held by a high-precision 6DoF robotic arm for dose measurements in the coronal plane during treatment delivery. For each combination of the motion trace and treatment plan, two film measurements were made, one with 6DoF motion and the other with the three-dimensional (3D) translation components of the same trace. A gamma pass rate criteria of 2% relative dose/2 mm distance-to-agreement was used in this study and evaluated for each measurement with respect to the static reference film. Two test thresholds, 90% and 50% of the reference dose, were applied to investigate the difference in dose coverage for the PTV region and surrounding areas, respectively. The hypothesis was tested using a Wilcoxon signed-rank test. RESULTS:For each of the 16 plan and motion trace pairs, a reduction in the gamma pass rate was observed for 6DoF motion compared with 3D translational motion. With 90% gamma-test threshold, the reduction was 5.8% ± 7.1% (P < 0.01). With 50% gamma-test threshold, the reduction was 4.1% ± 4.8% (P < 0.01). CONCLUSION:For the first time, the dosimetric impact of intrafraction prostate rotation during SBRT treatment was measured experimentally. The experimental results support the hypothesis that 6DoF tumor motion causes higher dose error than translation motion alone.

journal_name

Med Phys

journal_title

Medical physics

authors

Shi K,Dipuglia A,Booth J,Alnaghy S,Kyme A,Keall P,Nguyen DT

doi

10.1002/mp.14502

subject

Has Abstract

pub_date

2020-12-01 00:00:00

pages

6068-6076

issue

12

eissn

0094-2405

issn

2473-4209

journal_volume

47

pub_type

杂志文章
  • Dosimetric properties of radiophotoluminescent glass rod detector in high-energy photon beams from a linear accelerator and cyber-knife.

    abstract::A fully automatic radiophotoluminescent glass rod dosimeter (GRD) system has recently become commercially available. This article discusses the dosimetric properties of the GRD including uniformity and reproducibility of signal, dose linearity, and energy and directional dependence in high-energy photon beams. In addi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1758351

    authors: Arakia F,Moribe N,Shimonobou T,Yamashita Y

    更新日期:2004-07-01 00:00:00

  • Irradiation of gold nanoparticles by x-rays: Monte Carlo simulation of dose enhancements and the spatial properties of the secondary electrons production.

    abstract:PURPOSE:The aim of this study is to understand the characteristics of secondary electrons generated from the interaction of gold nanoparticles (GNPs) with x-rays as a function of nanoparticle size and beam energy and thereby further the understanding of GNP-enhanced radiotherapy. METHODS:The effective range, deflectio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3539623

    authors: Leung MK,Chow JC,Chithrani BD,Lee MJ,Oms B,Jaffray DA

    更新日期:2011-02-01 00:00:00

  • Fast dose optimization for rotating shield brachytherapy.

    abstract:PURPOSE:To provide a fast computational method, based on the proximal graph solver (POGS) - A convex optimization solver using the alternating direction method of multipliers (ADMM), for calculating an optimal treatment plan in rotating shield brachytherapy (RSBT). RSBT treatment planning has more degrees of freedom th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12486

    authors: Cho M,Wu X,Dadkhah H,Yi J,Flynn RT,Kim Y,Xu W

    更新日期:2017-10-01 00:00:00

  • Independent quality assurance of a helical tomotherapy machine using the dose magnifying glass.

    abstract:PURPOSE:Helical tomotherapy is a complex delivery technique, integrating CT image guidance and intensity modulated radiotherapy in a single system. The integration of the CT detector ring on the gantry not only allows patient position verification but is also often used to perform various QA procedures. This convenienc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3566067

    authors: Wong JH,Hardcastle N,Tomé WA,Bayliss A,Tolakanahalli R,Lerch ML,Petasecca M,Carolan M,Metcalfe P,Rosenfeld AB

    更新日期:2011-04-01 00:00:00

  • Rotationally resliced 3D prostate TRUS segmentation using convex optimization with shape priors.

    abstract:PURPOSE:Efficient and accurate segmentations of 3D end-firing transrectal ultrasound (TRUS) images play an important role in planning of 3D TRUS guided prostate biopsy. However, poor image quality of the input 3D TRUS images, such as strong imaging artifacts and speckles, often makes it a challenging task to extract th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4906129

    authors: Qiu W,Yuan J,Ukwatta E,Fenster A

    更新日期:2015-02-01 00:00:00

  • Technical Note: Correction for the effect of breathing variations in CT pulmonary ventilation imaging.

    abstract:PURPOSE:The accuracy and precision of computed tomography (CT) pulmonary ventilation imaging with conventional CT scanners are limited by breathing variations. We propose a method to correct for the effect of breathing variations in CT ventilation imaging based on external respiratory signals acquired throughout a scan...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1002/mp.12634

    authors: Yamamoto T,Kabus S

    更新日期:2018-01-01 00:00:00

  • Direct digitization of optical images using a photostimulable phosphor system.

    abstract::The authors describe a method for directly digitizing optical images with a photostimulable phosphor (PSP) system. A PSP plate is initially charged with an exposure to a uniform x-ray field, and is then exposed to an optical image which discharges the plate in relation to the amount of incident light. Two applications...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596917

    authors: Dobbins JT 3rd,Chotas HG,Benveniste H

    更新日期:1992-07-01 00:00:00

  • SU-C-218-06: Evaluation of a CT-Based, Semi-Automated Lung Mass Estimation Method Under Varying Acquisition Conditions.

    abstract:PURPOSE:To evaluate a simple, semi-automated lung mass estimation method on CT scans from a variety of acquisition techniques for mass correction of MIRD dose estimates. METHODS:CT scans from ten patients undergoing stereotactic body radiation therapy treatment planning on a GE DST PET/CT scanner were analyzed retrosp...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734654

    authors: Busse N,Erwin W,Pan T

    更新日期:2012-06-01 00:00:00

  • Sample size requirements for estimating effective dose from computed tomography using solid-state metal-oxide-semiconductor field-effect transistor dosimetry.

    abstract:PURPOSE:Effective dose (ED) is a widely used metric for comparing ionizing radiation burden between different imaging modalities, scanners, and scan protocols. In computed tomography (CT), ED can be estimated by performing scans on an anthropomorphic phantom in which metal-oxide-semiconductor field-effect transistor (M...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4868693

    authors: Trattner S,Cheng B,Pieniazek RL,Hoffmann U,Douglas PS,Einstein AJ

    更新日期:2014-04-01 00:00:00

  • Monte Carlo assessment of computed tomography dose to tissue adjacent to the scanned volume.

    abstract::The assessment of the radiation dose to internal organs or to an embryo or fetus is required on occasion for risk assessment or for comparing imaging studies. Limited resources hinder the ability to accurately assess the radiation dose received to locations outside the tissue volume actually scanned during computed to...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1312809

    authors: Boone JM,Cooper VN 3rd,Nemzek WR,McGahan JP,Seibert JA

    更新日期:2000-10-01 00:00:00

  • Thick phosphor screens for on-line portal imaging.

    abstract::Gd2O2S phosphor screens between 250 and 1000 mg/cm2 thick were evaluated for use in megavoltage imaging systems. The phosphor layers were placed on brass plates ranging from 1 to 5 mm thick, each with and without an optical back reflector (white paint). Light output and spatial resolution were measured at 6- and 23-MV...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597209

    authors: Wowk B,Shalev S

    更新日期:1994-08-01 00:00:00

  • SU-E-T-424: Inter-Fraction Variation of High Dose Regions of OARS in MR Image Based Cervix Brachytherapy Using Rigid Registration.

    abstract:PURPOSE:To quantify the inter fraction variation of spatial location of high dose regions of OARs in MR-image based cervix brachytherapy using rigid registration algorithm. METHODS:Retrospective analysis of 27 previously treated patients under EMBRACE multi-centric trial was evaluated. Each patient had two application...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735513

    authors: Swamidas J,Mahantshetty U,Deshpande D,Shrivastava S

    更新日期:2012-06-01 00:00:00

  • Accuracy of a 3D laser∕camera surface imaging system for setup verification of the pelvic and thoracic regions in radiotherapy treatments.

    abstract:PURPOSE:The aim of this paper is to investigate the accuracy of a laser∕camera surface imaging system (Sentinel) when used on patients treated in the thorax or pelvic regions and to evaluate system employment conditions and patient setup procedures that provide more accurate results. METHODS:The system was tested on t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4769428

    authors: Pallotta S,Simontacchi G,Marrazzo L,Ceroti M,Paiar F,Biti G,Bucciolini M

    更新日期:2013-01-01 00:00:00

  • Active energy selective image detector for dual-energy computed radiography.

    abstract::A new energy selective detector for dual energy computed radiography has been developed that combines many of the advantages of x-ray tube voltage switching and single exposure double screen detectors. The new active detector utilizes electro-optical modulation of the response of the storage phosphor screens to allow ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597831

    authors: Alvarez RE

    更新日期:1996-10-01 00:00:00

  • Automated registration of large deformations for adaptive radiation therapy of prostate cancer.

    abstract::Available deformable registration methods are often inaccurate over large organ variation encountered, for example, in the rectum and bladder. The authors developed a novel approach to accurately and effectively register large deformations in the prostate region for adaptive radiation therapy. A software tool combinin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3095777

    authors: Godley A,Ahunbay E,Peng C,Li XA

    更新日期:2009-04-01 00:00:00

  • SU-E-T-635: Effect of Planning Parameters on Tomotherapy Dosimetric Quality and Treatment Efficiency.

    abstract:PURPOSE:To investigate how the setting of optimization parameters, fractional dose and tuning structure in tomotherapy treatment planning affects plan dosimetric quality and treatment efficiency. METHODS:A digital phantom to simulate head and neck radiotherapy was constructed for this study. Tumor was 10cm long C-shap...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735724

    authors: Lian J,Burkhardt K,Chera B,Chang S

    更新日期:2012-06-01 00:00:00

  • A mobile isocentric C-arm for intraoperative cone-beam CT: Technical assessment of dose and 3D imaging performance.

    abstract:PURPOSE:To characterize the radiation dose and three-dimensional (3D) imaging performance of a recently developed mobile, isocentric C-arm equipped with a flat-panel detector (FPD) for intraoperative cone-beam computed tomography (CBCT) (Cios Spin 3D, Siemens Healthineers) and to identify potential improvements in 3D i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13983

    authors: Sheth NM,De Silva T,Uneri A,Ketcha M,Han R,Vijayan R,Osgood GM,Siewerdsen JH

    更新日期:2020-03-01 00:00:00

  • Differentiation between diamagnetic and paramagnetic cerebral lesions based on magnetic susceptibility mapping.

    abstract:PURPOSE:Identification of calcifications and hemorrhages is essential for the etiological diagnosis of cerebral lesions. The purpose of this work was to develop a robust method for characterization of para- and diamagnetic intracerebral lesions based on clinical gradient-echo magnetic resonance phase data acquired at 1...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3481505

    authors: Schweser F,Deistung A,Lehr BW,Reichenbach JR

    更新日期:2010-10-01 00:00:00

  • Iterative algebraic reconstruction algorithms for emission computed tomography: a unified framework and its application to positron emission tomography.

    abstract::In this paper, a unified framework of iterative algebraic reconstruction for emission computed tomography (ECT) and its application to positron emission tomography (PET) is presented. The unified framework is based on an algebraic image restoration model and contains conventional iterative algebraic reconstruction alg...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596954

    authors: Xu XL,Liow JS,Strother SC

    更新日期:1993-11-01 00:00:00

  • A moving blocker system for cone-beam computed tomography scatter correction.

    abstract:PURPOSE:Scatter contamination in cone-beam computed tomography (CBCT) degrades the image quality by introducing shading artifacts. A moving-blocker-based approach has been proposed to simultaneously estimate scatter and reconstruct the complete volume within field of view (FOV) from a single CBCT scan. Promising result...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4811086

    authors: Ouyang L,Song K,Wang J

    更新日期:2013-07-01 00:00:00

  • A new fast and fully automated software based algorithm for extracting respiratory signal from raw PET data and its comparison to other methods.

    abstract:PURPOSE:Respiratory gating in PET is an approach used to minimize the negative effects of respiratory motion on spatial resolution. It is based on an initial determination of a patient's respiratory movements during a scan, typically using hardware based systems. In recent years, several fully automated databased algor...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3483784

    authors: Kesner AL,Kuntner C

    更新日期:2010-10-01 00:00:00

  • A general model of microcirculatory blood flow effects in gradient sensitized MRI.

    abstract::A general expression is derived for the NMR signal from a fluid undergoing random directional flow such as encountered within the microcirculation. The dependence of the echo amplitude on flow velocity, sample morphology, and experimental parameters are described in terms of a temporal velocity autocorrelation functio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597170

    authors: Kennan RP,Gao JH,Zhong J,Gore JC

    更新日期:1994-04-01 00:00:00

  • A numerical study of the acoustic radiation due to eddy current-cryostat interactions.

    abstract:PURPOSE:To investigate the acoustic radiation due to eddy current-cryostat interactions and perform a qualitative analysis on noise reduction methods. METHODS:In order to evaluate the sound pressure level (SPL) of the eddy current induced warm bore wall vibration, a Finite Element (FE) model was created to simulate th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12261

    authors: Wang Y,Liu F,Zhou X,Li Y,Crozier S

    更新日期:2017-06-01 00:00:00

  • A dosimetric comparison of 169Yb and 192Ir for HDR brachytherapy of the breast, accounting for the effect of finite patient dimensions and tissue inhomogeneities.

    abstract::Monte Carlo simulation dosimetry is used to compare 169Yb to 192Ir for breast high dose rate (HDR) brachytherapy applications using multiple catheter implants. Results for bare point sources show that while 169Yb delivers a greater dose rate per unit air kerma strength at the radial distance range of interest to brach...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2392408

    authors: Lymperopoulou G,Papagiannis P,Angelopoulos A,Karaiskos P,Georgiou E,Baltas D

    更新日期:2006-12-01 00:00:00

  • A comparison of the physical imaging properties of Fuji ST-V, ST-VA, and ST-VN computed radiography image plates.

    abstract::The physical imaging performance of ST-V, ST-VA, and ST-VN computed radiography image plates, read with a Philips AC3 acquisition system, was investigated at 70 kVp with 0.5 mm of copper beam filtration for four different entrance air kerma values: 0.5, 2.6, 26, and 260 micro Gy. Measurements included characteristic r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598412

    authors: Kengyelics SM,Davies AG,Cowen AR

    更新日期:1998-11-01 00:00:00

  • On charged particle equilibrium violation in external photon fields.

    abstract:PURPOSE:In a recent paper by Bouchard et al. [Med. Phys. 36(10), 4654-4663 (2009)], a theoretical model of quality correction factors for idealistic so-called plan-class specific reference (PCSR) fields was proposed. The reasoning was founded on the definition of PCSR fields made earlier by Alfonso et al. [Med. Phys. 3...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3684952

    authors: Bouchard H,Seuntjens J,Palmans H

    更新日期:2012-03-01 00:00:00

  • Direct aperture deformation: an interfraction image guidance strategy.

    abstract::A new scheme, called direct aperture deformation (DAD), for online correction of interfraction geometric uncertainties under volumetric imaging guidance is presented. Using deformable image registration, the three-dimensional geometric transformation matrix can be derived that associates the planning image set and the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2374675

    authors: Feng Y,Castro-Pareja C,Shekhar R,Yu C

    更新日期:2006-12-01 00:00:00

  • Discrimination analysis of breast calcifications using x-ray dark-field radiography.

    abstract:BACKGROUND:X-ray dark-field radiography could enhance mammography by providing more information on imaged tissue and microcalcifications. The dark field signal is a measure of small angle scattering and can thus provide additional information on the imaged materials. This information can be useful for material distinct...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14043

    authors: Rauch T,Rieger J,Pelzer G,Horn F,Erber R,Wunderle M,Emons J,Nabieva N,Fuhrich N,Michel T,Hartmann A,Fasching PA,Anton G

    更新日期:2020-04-01 00:00:00

  • Knowledge-based planning for intensity-modulated radiation therapy: A review of data-driven approaches.

    abstract:PURPOSE:Intensity-Modulated Radiation Therapy (IMRT), including its variations (including IMRT, Volumetric Arc Therapy (VMAT), and Tomotherapy), is a widely used and critically important technology for cancer treatment. It is a knowledge-intensive technology due not only to its own technical complexity, but also to the...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1002/mp.13526

    authors: Ge Y,Wu QJ

    更新日期:2019-06-01 00:00:00

  • Structure and adaptation of arteries to pulsatile flow: the case of the ascending aorta.

    abstract:PURPOSE:The objectives are: (i) assess the development of the impedance of some arteries during the first decades of life; (ii) determine the influence of pulse rate in arterial impedance; (iii) compare the structure of some arterial segments with optimized structures with respect to blood flow; and (iv) explain the el...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4876379

    authors: Silva C,Reis AH

    更新日期:2014-06-01 00:00:00