Direct aperture deformation: an interfraction image guidance strategy.

Abstract:

:A new scheme, called direct aperture deformation (DAD), for online correction of interfraction geometric uncertainties under volumetric imaging guidance is presented. Using deformable image registration, the three-dimensional geometric transformation matrix can be derived that associates the planning image set and the images acquired on the day of treatment. Rather than replanning or moving the patient, we use the deformation matrix to morph the treatment apertures as a potential online correction method. A proof-of-principle study using an intensity-modulated radiation therapy plan for a prostate cancer patient was conducted. The method, procedure, and algorithm of DAD are described. The dose-volume histograms from the original plan, reoptimized plan, and rigid-body translation plan are compared with the ones from the DAD plan. The study showed the feasibility of the DAD as a general method for both target dislocation and deformation. As compared with using couch translation to move the patient, DAD is capable of correcting both target dislocation and deformations. As compared with reoptimization, online correction using the DAD scheme could be completed within a few minutes rather than tens of minutes and the speed gain would be at a very small cost of plan quality.

journal_name

Med Phys

journal_title

Medical physics

authors

Feng Y,Castro-Pareja C,Shekhar R,Yu C

doi

10.1118/1.2374675

subject

Has Abstract

pub_date

2006-12-01 00:00:00

pages

4490-8

issue

12

eissn

0094-2405

issn

2473-4209

journal_volume

33

pub_type

杂志文章
  • Nitroxide conjugate of a thermally responsive elastin-like polypeptide for noninvasive thermometry.

    abstract::Hyperthermia, as an adjuvant with radiation and chemotherapy, has shown promise in the treatment of cancer. The relevant biological effects of a hyperthermia treatment are both time and temperature-dependent, creating a need for accurate thermometry. We present a novel noninvasive thermometry modality that combines a ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1782677

    authors: Dreher MR,Elas M,Ichikawa K,Barth ED,Chilkoti A,Rosen GM,Halpern HJ,Dewhirst M

    更新日期:2004-10-01 00:00:00

  • An accelerated threshold-based back-projection algorithm for compton camera image reconstruction.

    abstract:PURPOSE:Compton camera imaging (CCI) systems are currently under investigation for radiotherapy dose reconstruction and verification. The ability of such a system to provide real-time images during dose delivery will be limited by the computational speed of the image reconstruction algorithm. In this work, the authors ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3519873

    authors: Mundy DW,Herman MG

    更新日期:2011-01-01 00:00:00

  • A technical solution to avoid partial scan artifacts in cardiac MDCT.

    abstract::Quantitative evaluation of cardiac image data obtained using multidetector row computed tomography (CT) is compromised by partial scan reconstructions, which improve the temporal resolution but significantly increase image-to-image CT number variations for a fixed region of interest compared to full reconstruction ima...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2805476

    authors: Primak AN,Dong Y,Dzyubak OP,Jorgensen SM,McCollough CH,Ritman EL

    更新日期:2007-12-01 00:00:00

  • Medical applications of shortwave FM radar: remote monitoring of cardiac and respiratory motion.

    abstract:PURPOSE:This article introduces the use of low power continuous wave frequency modulated radar for medical applications, specifically for remote monitoring of vital signs in patients. METHODS:Gigahertz frequency radar measures the electromagnetic wave signal reflected from the surface of a human body and from tissue b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3267038

    authors: Mostov K,Liptsen E,Boutchko R

    更新日期:2010-03-01 00:00:00

  • Rare-earth scatter fractions in chest radiography.

    abstract::A beam stop technique was used to measure the densitometric scatter fractions under three regions of a humanoid chest phantom utilizing LaOBr and Gd2O2S screens. For these receptors, the scatter fractions under the lung and retrocardiac areas were 13%-36% lower than published values for CaWO4. In the mediastinal area,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597041

    authors: Petrone TJ,Steidley KD

    更新日期:1993-03-01 00:00:00

  • Investigation of the use of MOSFET for clinical IMRT dosimetric verification.

    abstract::(Received 22 October 2001; accepted for publication 26 March 2002; published 22 May 2002) With advanced conformal radiotherapy using intensity modulated beams, it is important to have radiation dose verification measurements prior to treatment. Metal oxide semiconductor field effect transistors (MOSFET) have the advan...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1481520

    authors: Chuang CF,Verhey LJ,Xia P

    更新日期:2002-06-01 00:00:00

  • Computerized detection of lung nodules through radiomics.

    abstract:PURPOSE:Lung cancer is a major cause of cancer deaths, and the 5-year survival rate of stage IV lung cancer patients is only 2%. However, the 5-year survival rate of stage I lung cancer patients significantly increases to 50%. As such, spiral computed tomography (CT) scans are necessary to diagnose high-risk lung cance...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12331

    authors: Ma J,Zhou Z,Ren Y,Xiong J,Fu L,Wang Q,Zhao J

    更新日期:2017-08-01 00:00:00

  • Patient doses and projection angle in cone beam CT.

    abstract:PURPOSE:To investigate how x-ray tube projection angle affects organ and effective doses to patients undergoing a CT examination on a cone beam scanner. METHODS:The authors investigated two cone beam CT systems that use a flat panel detector to capture the x-ray pattern transmitted through patients. One system had the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3397458

    authors: He W,Huda W,Magill D,Tavrides E,Yao H

    更新日期:2010-05-01 00:00:00

  • Unwanted radiation produced by leakage neutrons from medical electron accelerators.

    abstract::Monte Carlo calculations have been made to determine the energy delivered to a phantom by neutrons escaping from the head of a Varian Clinac 35 medical accelerator at an SSD of 1 m. The energy was sorted into two regions: inside and outside a volume defined by a circular beam of area 100 and 600 cm2. For the two beam ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595067

    authors: Ing H,Shore RA

    更新日期:1982-01-01 00:00:00

  • Patch-based generation of a pseudo CT from conventional MRI sequences for MRI-only radiotherapy of the brain.

    abstract:PURPOSE:In radiotherapy (RT) based on magnetic resonance imaging (MRI) as the only modality, the information on electron density must be derived from the MRI scan by creating a so-called pseudo computed tomography (pCT). This is a nontrivial task, since the voxel-intensities in an MRI scan are not uniquely related to e...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4914158

    authors: Andreasen D,Van Leemput K,Hansen RH,Andersen JA,Edmund JM

    更新日期:2015-04-01 00:00:00

  • Automatic measurements of image geometry for online calibration of C-arm fluoroscopy.

    abstract::Calibrated C-arm fluoroscopy is used for a variety of surgical procedures where surgical tools and anatomical structures need to be located in space. Calibration can be performed online by combining measurements of the geometry of the image (center and radius) with measurements of a grid of fiducial markers. This arti...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1118/1.1781331

    authors: Archip N,Rohling R

    更新日期:2004-09-01 00:00:00

  • Metal artifact correction for x-ray computed tomography using kV and selective MV imaging.

    abstract:PURPOSE:The overall goal of this work is to improve the computed tomography (CT) image quality for patients with metal implants or fillings by completing the missing kilovoltage (kV) projection data with selectively acquired megavoltage (MV) data that do not suffer from photon starvation. When both of these imaging sys...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4901551

    authors: Wu M,Keil A,Constantin D,Star-Lack J,Zhu L,Fahrig R

    更新日期:2014-12-01 00:00:00

  • Spatial and temporal performance of 3D optical surface imaging for real-time head position tracking.

    abstract:PURPOSE:The spatial and temporal tracking performance of a commercially available 3D optical surface imaging system is evaluated for its potential use in frameless stereotactic radiosurgery head tracking applications. METHODS:Both 3D surface and infrared (IR) marker tracking were performed simultaneously on a head pha...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4823757

    authors: Wiersma RD,Tomarken SL,Grelewicz Z,Belcher AH,Kang H

    更新日期:2013-11-01 00:00:00

  • Effects of finite angular steps and extent of profile data on the calculation of rotational x-ray dose distributions.

    abstract::Computer algorithms for rotational therapy beams, in most cases, perform dose calculations by summing stored fixed beam data at finite angular steps. Such an algorithm, based on the Bentley beam model, was evaluated by comparing calculations with measured data for an 18-MV x-ray beam. Measurements were made in a speci...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595985

    authors: Kurup RG,Hogstrom KR,Hwang CC

    更新日期:1987-11-01 00:00:00

  • Novel detector design for reducing intercell x-ray cross-talk in the variable resolution x-ray CT scanner: a Monte Carlo study.

    abstract:PURPOSE:The variable resolution x-ray (VRX) CT scanner provides substantial improvement in the spatial resolution by matching the scanner's field of view (FOV) to the size of the object being imaged. Intercell x-ray cross-talk is one of the most important factors limiting the spatial resolution of the VRX detector. In ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3555035

    authors: Arabi H,Asl AR,Ay MR,Zaidi H

    更新日期:2011-03-01 00:00:00

  • Incorporation of treatment plan spatial and temporal dose patterns into a prostate intrafractional motion management strategy.

    abstract:PURPOSE:Periodic MV∕KV radiographs taken during volumetric modulated arc therapy (VMAT) for hypofractionated treatment provide guidance in intrafractional motion management. The choice of imaging frequency and timing are key components in delivering the desired dose while reducing associated overhead such as imaging do...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4742846

    authors: Zhang P,Hunt M,Happersett L,Cox B,Mageras G

    更新日期:2012-09-01 00:00:00

  • Plan averaging for multicriteria navigation of sliding window IMRT and VMAT.

    abstract:PURPOSE:To describe a method for combining sliding window plans [intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT)] for use in treatment plan averaging, which is needed for Pareto surface navigation based multicriteria treatment planning. METHODS:The authors show that by taking an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4859295

    authors: Craft D,Papp D,Unkelbach J

    更新日期:2014-02-01 00:00:00

  • Validating FMEA output against incident learning data: A study in stereotactic body radiation therapy.

    abstract:PURPOSE:Though failure mode and effects analysis (FMEA) is becoming more widely adopted for risk assessment in radiation therapy, to our knowledge, its output has never been validated against data on errors that actually occur. The objective of this study was to perform FMEA of a stereotactic body radiation therapy (SB...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4919440

    authors: Yang F,Cao N,Young L,Howard J,Logan W,Arbuckle T,Sponseller P,Korssjoen T,Meyer J,Ford E

    更新日期:2015-06-01 00:00:00

  • Technical Note: Noninvasive mid-IR fiber-optic evanescent wave spectroscopy (FEWS) for early detection of skin cancers.

    abstract:PURPOSE:Melanoma is the most lethal of the three primary skin cancers, including also basal cell carcinoma (BCC) and squamous cell carcinoma (SCC), which are less lethal. The accepted diagnosis process involves manually observing a suspicious lesion through a Dermascope (i.e., a magnifying glass), followed by a biopsy....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14471

    authors: Basov S,Dankner Y,Weinstein M,Katzir A,Platkov M

    更新日期:2020-11-01 00:00:00

  • Evaluation of two methods of predicting MLC leaf positions using EPID measurements.

    abstract::In intensity modulated radiation treatments (IMRT), the position of the field edges and the modulation within the beam are often achieved with a multileaf collimator (MLC). During the MLC calibration process, due to the finite accuracy of leaf position measurements, a systematic error may be introduced to leaf positio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2335490

    authors: Parent L,Seco J,Evans PM,Dance DR,Fielding A

    更新日期:2006-09-01 00:00:00

  • A Monte Carlo comparison of the response of the PTW-diamond and the TL-diamond detectors in megavoltage photon beams.

    abstract::A detailed Monte Carlo study of the PTW-diamond solid state detector response in megavoltage photon beams (60Co gamma rays to 25 MV x rays) has been performed with the EGS4 Monte Carlo Code. The sensitive volume of the diamond detector is a disk of diameter 4.4 mm and thickness 0.40 mm. The phantom material was water ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598771

    authors: Mobit PN,Sandison GA

    更新日期:1999-11-01 00:00:00

  • Statistical analysis of dose-volume and dose-wall histograms for rectal toxicity following 3D-CRT in prostate cancer.

    abstract::The purpose of this paper is to determine the correlation between dose-volume histogram (DVH) and dose wall-histogram (DWH) in the evaluation of rectal complications for prostate cancer patients treated with three-dimensional conformal radiotherapy (3D-CRT). A retrospective analysis of DVHs and DWHs of a subset of 25 ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1951427

    authors: García-Vicente F,Zapatero A,Floriano A,Cruz-Conde A,Perez L,Marín A,Mínguez C,Torres JJ

    更新日期:2005-08-01 00:00:00

  • Stereomammography: evaluation of depth perception using a virtual 3D cursor.

    abstract::We are evaluating the usefulness of stereomammography in improving breast cancer diagnosis. One area that we are investigating is whether the improved depth perception associated with stereomammography might be significantly enhanced with the use of a virtual 3D cursor. A study was performed to evaluate the accuracy o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.599008

    authors: Goodsitt MM,Chan HP,Hadjiiski L

    更新日期:2000-06-01 00:00:00

  • Efficient generation of a magnetic field-free line.

    abstract:PURPOSE:Signal encoding in magnetic particle imaging (MPI) is achieved by moving a field-free point (FFP) through the region of interest. One way to increase the sensitivity of the method is to scan the region of interest with a field-free line (FFL) instead of the FFP. Recently, the first feasible FFL coil setup was i...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1118/1.3447726

    authors: Knopp T,Erbe M,Biederer S,Sattel TF,Buzug TM

    更新日期:2010-07-01 00:00:00

  • A multimodality segmentation framework for automatic target delineation in head and neck radiotherapy.

    abstract:PURPOSE:To develop an automatic segmentation algorithm integrating imaging information from computed tomography (CT), positron emission tomography (PET), and magnetic resonance imaging (MRI) to delineate target volume in head and neck cancer radiotherapy. METHODS:Eleven patients with unresectable disease at the tonsil...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4928485

    authors: Yang J,Beadle BM,Garden AS,Schwartz DL,Aristophanous M

    更新日期:2015-09-01 00:00:00

  • Quantitation of SPECT performance: Report of Task Group 4, Nuclear Medicine Committee.

    abstract::A comprehensive performance testing program is an essential ingredient of high-quality single-photon emission computed tomography (SPECT). Many of the procedures previously published are complicated, time consuming, or require a special testing environment. This Task Group developed a protocol for evaluating SPECT ima...

    journal_title:Medical physics

    pub_type: 指南,杂志文章

    doi:10.1118/1.597605

    authors: Graham LS,Fahey FH,Madsen MT,van Aswegen A,Yester MV

    更新日期:1995-04-01 00:00:00

  • Improved modeling of multiple scattering in the Voxel Monte Carlo model.

    abstract::The implementation of an improved model for multiple scattering into the-Voxel Monte Carlo (VMC) algorithm for fast electron dose calculation in radiation therapy is presented. The model takes into account path-length corrections (PLC) and lateral displacement in the individual electron steps. The extraction of the sc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597933

    authors: Kawrakow I

    更新日期:1997-04-01 00:00:00

  • Tomosynthesis-based localization of radioactive seeds in prostate brachytherapy.

    abstract::Accurately assessing the quality of prostate brachytherapy intraoperatively would be valuable for improved clinical outcome by ensuring the delivery of a prescribed tumoricidal radiation dose to the entire prostate gland. One necessary step towards this goal is the robust and rapid localization of implanted seeds. Sev...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1624755

    authors: Tutar IB,Managuli R,Shamdasani V,Cho PS,Pathak SD,Kim Y

    更新日期:2003-12-01 00:00:00

  • On the use of C-arm fluoroscopy for treatment planning in high dose rate brachytherapy.

    abstract::Treatment planning for brachytherapy requires the acquisition of geometrical information of the implant applicator and the patient anatomy. This is typically done using a simulator or a computed tomography scanner. In this study, we present a different method by which orthogonal images from a C-arm fluoroscopic machin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1598851

    authors: Liu L,Bassano DA,Prasad SC,Keshler BL,Hahn SS

    更新日期:2003-09-01 00:00:00

  • Objective characterization of GE discovery CT750 HD scanner: gemstone spectral imaging mode.

    abstract:PURPOSE:To objectively characterize the performance of the gemstone spectral imaging (GSI) mode of GE CT750 HD scanner from a user's perspective. METHODS:A regular scan protocol that approximates the adult abdomen scan protocol frequently used in the authors' institute was selected as the baseline, and a GSI protocol ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3551999

    authors: Zhang D,Li X,Liu B

    更新日期:2011-03-01 00:00:00