A technical solution to avoid partial scan artifacts in cardiac MDCT.

Abstract:

:Quantitative evaluation of cardiac image data obtained using multidetector row computed tomography (CT) is compromised by partial scan reconstructions, which improve the temporal resolution but significantly increase image-to-image CT number variations for a fixed region of interest compared to full reconstruction images. The feasibility of a new approach to solve this problem is assessed. An anthropomorphic cardiac phantom and an anesthetized pig were scanned on a dual-source CT scanner using both full and partial scan acquisition modes under different conditions. Additional scans were conducted with the electrocardiogram (ECG) signal being in synchrony with the gantry rotation. In the animal study, a simple x-ray detector was used to generate a signal once per gantry rotation. This signal was then used to pace the pig's heart. Phantom studies demonstrated that partial scan artifacts are strongly dependent on the rotational symmetry of angular projections, which is determined by the object shape and composition and its position with respect to the isocenter. The degree of partial scan artifacts also depends on the location of the region of interest with respect to highly attenuating materials (bones, iodine, etc.) within the object. Single-source partial scan images (165 ms temporal resolution) were significantly less affected by partial scan artifacts compared to dual-source partial scan images (82 ms temporal resolution). When the ECG signal was in synchrony with the gantry rotation, the same cardiac phase always corresponded to the same positions of the x-ray tube(s) and, hence, the same scattering and beam hardening geometry. As a result, the range of image-to-image CT number variations for partial scan reconstruction images acquired in synchronized mode was decreased to that achieved using full reconstruction image data. The success of the new approach, which synchronizes the ECG signal with the position of the x-ray tube(s), was demonstrated both in the phantom and animal experiments.

journal_name

Med Phys

journal_title

Medical physics

authors

Primak AN,Dong Y,Dzyubak OP,Jorgensen SM,McCollough CH,Ritman EL

doi

10.1118/1.2805476

subject

Has Abstract

pub_date

2007-12-01 00:00:00

pages

4726-37

issue

12

eissn

0094-2405

issn

2473-4209

journal_volume

34

pub_type

杂志文章
  • Pharmacokinetic modeling.

    abstract::For radiation dosimetry calculations of radiolabeled monoclonal antibodies, (MAB), pharmacokinetics are critical. Specifically, pharmacokinetic modeling is a useful component of estimation of cumulated activity in various source organs in the body. It is thus important to formulate general methods of pharmacokinetic m...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.597047

    authors: Strand SE,Zanzonico P,Johnson TK

    更新日期:1993-03-01 00:00:00

  • Quantification of breast density with dual energy mammography: a simulation study.

    abstract::Breast density, the percentage of glandular breast tissue, has been identified as an important yet underutilized risk factor in the development of breast cancer. A quantitative method to measure breast density with dual energy imaging was investigated using a computer simulation model. Two configurations to measure br...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3002308

    authors: Ducote JL,Molloi S

    更新日期:2008-12-01 00:00:00

  • Lung morphometry using hyperpolarized 129 Xe multi-b diffusion MRI with compressed sensing in healthy subjects and patients with COPD.

    abstract:PURPOSE:To demonstrate the feasibility of compressed sensing (CS) to accelerate the acquisition of hyperpolarized (HP) 129 Xe multi-b diffusion MRI for quantitative assessments of lung microstructural morphometry. METHODS:Six healthy subjects and six chronic obstructive pulmonary disease (COPD) subjects underwent HP 1...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12944

    authors: Zhang H,Xie J,Xiao S,Zhao X,Zhang M,Shi L,Wang K,Wu G,Sun X,Ye C,Zhou X

    更新日期:2018-07-01 00:00:00

  • Poster - Thurs Eve-32: Dose errors related to the treatment couch.

    abstract::Modern radiotherapy linacs often use carbon fibre for their couch tops due to its radio translucent properties. Beam attenuation by the couches is often ignored during planning and MU calculation. This work examines beam attenuation and loss of "skin sparing" (dose build up region) when various photon beams transit ei...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965951

    authors: Niedbala M,Nyiri B,Gerig L

    更新日期:2008-07-01 00:00:00

  • Surface imaging for real-time patient respiratory function assessment in intensive care.

    abstract:PURPOSE:Monitoring of physiological parameters is a major concern in Intensive Care Units (ICU) given their role in the assessment of vital organ function. Within this context, one issue is the lack of efficient noncontact techniques for respiratory monitoring. In this paper, we present a novel noncontact solution for ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14557

    authors: Nazir S,Pateau V,Bert J,Clement JF,Fayad H,l'Her E,Visvikis D

    更新日期:2020-10-28 00:00:00

  • SU-E-T-558: Assessing the Effect of Inter-Fractional Motion in Esophageal Sparing Plans.

    abstract:PURPOSE:To compare esophageal dose distributions in esophageal sparing IMRT plans with predicted dose distributions which include the effect of inter-fraction motion. METHODS:Seven lung cancer patients were used, each with a standard and an esophageal sparing plan (74Gy, 2Gy fractions). The average max dose to esophag...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735647

    authors: Williamson R,Bluett J,Niedzielski J,Liao Z,Gomez D,Court L

    更新日期:2012-06-01 00:00:00

  • Determination of the photon spectrum of a clinical accelerator.

    abstract::An experiment to determine the peak of the energy spectrum of the photon beam from a Toshiba LMR-15 medical linear accelerator is described. It is found that the flattening filters removed much of the bremsstrahlung spectrum below approximately 1 MeV, resulting in a photon spectrum which peaks around 1.2 MeV. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595582

    authors: Brownridge J,Samnick S,Stiles P,Tipton P,Veselka J,Yeh N

    更新日期:1984-11-01 00:00:00

  • Scatter transmission through an ideal grid.

    abstract::An analytic expression is derived for the transmission of isotropic scattered radiation incident upon an ideal parallel grid. It is found that the expression for the transmission usually found in the literature overestimates the transmission by approximately a factor of two. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594877

    authors: Siddon RL

    更新日期:1981-11-01 00:00:00

  • An investigation on the use of removal-diffusion theory for BNCT treatment planning: a method for determining proper removal-diffusion parameters.

    abstract::This paper outlines a method for determining proper removal-diffusion parameters to be used in removal-diffusion theory calculations for the purpose of BNCT treatment planning. Additionally, this paper demonstrates that, given the proper choice of removal-diffusion parameters, removal-diffusion theory may provide an a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1386424

    authors: Albertson BJ,Blue TE,Niemkiewicz J

    更新日期:2001-09-01 00:00:00

  • Maximum likelihood estimation of proton irradiated field and deposited dose distribution.

    abstract::In proton therapy, it is important to evaluate the field irradiated with protons and the deposited dose distribution in a patient's body. Positron emitters generated through fragmentation reactions of target nuclei can be used for this purpose. By detecting the annihilation gamma rays from the positron emitters, the a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2712572

    authors: Inaniwa T,Kohno T,Yamagata F,Tomitani T,Sato S,Kanazawa M,Kanai T,Urakabe E

    更新日期:2007-05-01 00:00:00

  • Ultrasound viscoelasticity assessment using an adaptive torsional shear wave propagation method.

    abstract:PURPOSE:Different approaches have been used in dynamic elastography to assess mechanical properties of biological tissues. Most techniques are based on a simple inversion based on the measurement of the shear wave speed to assess elasticity, whereas some recent strategies use more elaborated analytical or finite elemen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4942813

    authors: Ouared A,Kazemirad S,Montagnon E,Cloutier G

    更新日期:2016-04-01 00:00:00

  • Effects of x-ray beam equalization on mammographic imaging.

    abstract::We employed an elastic reservoir filled with tissue-equivalent fluid as an x-ray beam filter for exposure equalization. The filter is designed to be placed between the upper compression plate and the breast. During compression, it will conform to the shape of the peripheral region of the breast and fill the space betw...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596502

    authors: Lam KL,Chan HP

    更新日期:1990-03-01 00:00:00

  • Wavelength dependence of the precision of noninvasive optical measurement of oxy-, deoxy-, and total-hemoglobin concentration.

    abstract::The precision of noninvasive optical measurement of the concentration changes in oxy-, deoxy-, and total-hemoglobin depends on wavelength. For estimating the precision, we calculated the noise level of the concentration changes as the uncertainty in measurements using several wavelength pairs of light. Seven laser dio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1373401

    authors: Yamashita Y,Maki A,Koizumi H

    更新日期:2001-06-01 00:00:00

  • Sparse and optimal acquisition design for diffusion MRI and beyond.

    abstract:PURPOSE:Diffusion magnetic resonance imaging (MRI) in combination with functional MRI promises a whole new vista for scientists to investigate noninvasively the structural and functional connectivity of the human brain-the human connectome, which had heretofore been out of reach. As with other imaging modalities, diffu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3700166

    authors: Koay CG,Ozarslan E,Johnson KM,Meyerand ME

    更新日期:2012-05-01 00:00:00

  • Automated lung segmentation of diseased and artifact-corrupted magnetic resonance sections.

    abstract::Segmentation of the lungs within magnetic resonance (MR) scans is a necessary step in the computer-based analysis of thoracic MR images. This process is often confounded by image acquisition artifacts and disease-induced morphological deformation. We have developed an automated method for lung segmentation that is ins...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2214165

    authors: Sensakovic WF,Armato SG 3rd,Starkey A,Caligiuri P

    更新日期:2006-09-01 00:00:00

  • Evaluation of a commercial MRI Linac based Monte Carlo dose calculation algorithm with GEANT4.

    abstract:PURPOSE:This paper provides a comparison between a fast, commercial, in-patient Monte Carlo dose calculation algorithm (GPUMCD) and geant4. It also evaluates the dosimetric impact of the application of an external 1.5 T magnetic field. METHODS:A stand-alone version of the Elekta™ GPUMCD algorithm, to be used within th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4939808

    authors: Ahmad SB,Sarfehnia A,Paudel MR,Kim A,Hissoiny S,Sahgal A,Keller B

    更新日期:2016-02-01 00:00:00

  • Validation for 2D/3D registration. I: A new gold standard data set.

    abstract:PURPOSE:In this article, the authors propose a new gold standard data set for the validation of two-dimensional/three-dimensional (2D/3D) and 3D/3D image registration algorithms. METHODS:A gold standard data set was produced using a fresh cadaver pig head with attached fiducial markers. The authors used several imagin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3553402

    authors: Pawiro SA,Markelj P,Pernus F,Gendrin C,Figl M,Weber C,Kainberger F,Nöbauer-Huhmann I,Bergmeister H,Stock M,Georg D,Bergmann H,Birkfellner W

    更新日期:2011-03-01 00:00:00

  • Small SRS photon field profile dosimetry performed using a PinPoint air ion chamber, a diamond detector, a novel silicon-diode array (DOSI), and polymer gel dosimetry. Analysis and intercomparison.

    abstract::Small photon fields are increasingly used in modern radiotherapy and especially in IMRT and SRS/SRT treatments. The uncertainties related to small field profile measurements can introduce significant systematic errors to the overall treatment process. These measurements are challenging mainly due to the absence of cha...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2977829

    authors: Pappas E,Maris TG,Zacharopoulou F,Papadakis A,Manolopoulos S,Green S,Wojnecki C

    更新日期:2008-10-01 00:00:00

  • A material sensitivity study on the accuracy of deformable organ registration using linear biomechanical models.

    abstract::Model-based deformable organ registration techniques using the finite element method (FEM) have recently been investigated intensively and applied to image-guided adaptive radiotherapy (IGART). These techniques assume that human organs are linearly elastic material, and their mechanical properties are predetermined. U...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2163838

    authors: Chi Y,Liang J,Yan D

    更新日期:2006-02-01 00:00:00

  • Performance tests of two portable mini gamma cameras for medical applications.

    abstract::We have developed two prototypes of portable gamma cameras for medical applications based on a previous prototype designed and tested by our group. These cameras use a CsI(Na) continuous scintillation crystal coupled to the new flat-panel-type multianode position-sensitive photomultiplier tube, H8500 from Hamamatsu Ph...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2358199

    authors: Sánchez F,Fernández MM,Giménez M,Benlloch JM,Rodríguez-Alvarez MJ,García de Quirós F,Lerche Ch,Pavón N,Palazón JA,Martínez J,Sebastiá A

    更新日期:2006-11-01 00:00:00

  • A survey of the information gained from planning treatment with a computer.

    abstract::We designed a questionnaire to be filled out by the physicist at the time of planning treatment with the aid of a computer in order to assess what was learned during the course of the planning session. We analyzed the results to gauge the impact of the 70 treatment planning sessions conducted during the one month peri...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596302

    authors: Doppke KP,Goitein M

    更新日期:1988-03-01 00:00:00

  • Dosimetric characterization of Ir-192 LDR elongated sources.

    abstract::Ir-192 wires have been used in low-dose-rate brachytherapy for many years. Commercially available treatment planning systems approximate the dose rate distribution of the straight or curved wires applying the superposition principle using one of the following methods: (i) The wire is modeled as a set of point sources,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2839102

    authors: van der Laarse R,Granero D,Pérez-Calatayud J,Meigooni AS,Ballester F

    更新日期:2008-03-01 00:00:00

  • Determination of the quality index (Q) for photon beams at arbitrary field sizes.

    abstract:PURPOSE:A commonly used beam quality index (Q) for high-energy photon beams is the tissue phantom ratio (TPR20,10) for a square field of 10 x 10 cm2 and SDD of 100 cm. On some specialized radiotherapy treatment equipment such a reference collimator setting is not achievable. Likewise a flat beam profile, not explicitly...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3197062

    authors: Sauer OA

    更新日期:2009-09-01 00:00:00

  • Rapid in vivo localization of a lost brachytherapy seed.

    abstract::We adapted a small sodium iodide scintillation detector for rapid, in vivo localization of a lost brachytherapy seed. Using the detector, we were able to locate and remove an Ir-192 seed that was not visible to the unaided eye. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595528

    authors: Woolfenden JM,Barber HB,Oleson JR,Wild WJ

    更新日期:1984-07-01 00:00:00

  • SU-E-T-126: Non-Reference Condition Correction Factor KNR of Typical Radiation Detectors for the Dosimetry of High-Energy Photons.

    abstract:PURPOSE:To correct for the deviations of the detector response when typical radiation detectors are used under non-reference conditions, factor kNR was calculated from the known energy dependence of the detector response at photon energies from 10 keV upwards and from clinical photon spectra within a large water phanto...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735184

    authors: Chofor N,Poppe B,Harder D

    更新日期:2012-06-01 00:00:00

  • Projection-based improvement of 3D reconstructions from motion-impaired dental cone beam CT data.

    abstract:PURPOSE:Computed tomography (CT) and, in particular, cone beam CT (CBCT) have been increasingly used as a diagnostic tool in recent years. Patient motion during acquisition is common in CBCT due to long scan times. This results in degraded image quality and may potentially increase the number of retakes. Our aim was to...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13731

    authors: Niebler S,Schömer E,Tjaden H,Schwanecke U,Schulze R

    更新日期:2019-10-01 00:00:00

  • Penalized likelihood fluence optimization with evolutionary components for intensity modulated radiation therapy treatment planning.

    abstract::A novel iterative penalized likelihood algorithm with evolutionary components for the optimization of beamlet fluences for intensity modulated radiation therapy (IMRT) is presented. This algorithm is designed to be flexible in terms of the objective function and automatically escalates dose, as long as the objective f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1773631

    authors: Baydush AH,Marks LB,Das SK

    更新日期:2004-08-01 00:00:00

  • Computation of energy imparted in diagnostic radiology.

    abstract::Energy imparted is a measure of the total ionizing energy deposited in the patient during a radiologic examination and may be used to quantify the patient dose in diagnostic radiology. Values of the energy imparted per unit exposure-area product, omega (z), absorbed by a semi-infinite water phantom with a thickness z,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597939

    authors: Gkanatsios NA,Huda W

    更新日期:1997-04-01 00:00:00

  • Automated registration of large deformations for adaptive radiation therapy of prostate cancer.

    abstract::Available deformable registration methods are often inaccurate over large organ variation encountered, for example, in the rectum and bladder. The authors developed a novel approach to accurately and effectively register large deformations in the prostate region for adaptive radiation therapy. A software tool combinin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3095777

    authors: Godley A,Ahunbay E,Peng C,Li XA

    更新日期:2009-04-01 00:00:00

  • Dosimetry for 252Cf neutron emitting brachytherapy sources: protocol, measurements, and calculations.

    abstract::The mixed-field dosimetry for 252Cf Applicator Tube (AT) type medical sources available from Oak Ridge National Laboratory (ORNL) has been characterized using ionization chambers, a GM counter, and Monte Carlo methods. Unlike the AAPM Task Group No. 43 (TG-43), specification of dose to muscle instead of water is recom...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598646

    authors: Rivard MJ

    更新日期:1999-08-01 00:00:00