Abstract:
:Quantitative evaluation of cardiac image data obtained using multidetector row computed tomography (CT) is compromised by partial scan reconstructions, which improve the temporal resolution but significantly increase image-to-image CT number variations for a fixed region of interest compared to full reconstruction images. The feasibility of a new approach to solve this problem is assessed. An anthropomorphic cardiac phantom and an anesthetized pig were scanned on a dual-source CT scanner using both full and partial scan acquisition modes under different conditions. Additional scans were conducted with the electrocardiogram (ECG) signal being in synchrony with the gantry rotation. In the animal study, a simple x-ray detector was used to generate a signal once per gantry rotation. This signal was then used to pace the pig's heart. Phantom studies demonstrated that partial scan artifacts are strongly dependent on the rotational symmetry of angular projections, which is determined by the object shape and composition and its position with respect to the isocenter. The degree of partial scan artifacts also depends on the location of the region of interest with respect to highly attenuating materials (bones, iodine, etc.) within the object. Single-source partial scan images (165 ms temporal resolution) were significantly less affected by partial scan artifacts compared to dual-source partial scan images (82 ms temporal resolution). When the ECG signal was in synchrony with the gantry rotation, the same cardiac phase always corresponded to the same positions of the x-ray tube(s) and, hence, the same scattering and beam hardening geometry. As a result, the range of image-to-image CT number variations for partial scan reconstruction images acquired in synchronized mode was decreased to that achieved using full reconstruction image data. The success of the new approach, which synchronizes the ECG signal with the position of the x-ray tube(s), was demonstrated both in the phantom and animal experiments.
journal_name
Med Physjournal_title
Medical physicsauthors
Primak AN,Dong Y,Dzyubak OP,Jorgensen SM,McCollough CH,Ritman ELdoi
10.1118/1.2805476subject
Has Abstractpub_date
2007-12-01 00:00:00pages
4726-37issue
12eissn
0094-2405issn
2473-4209journal_volume
34pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::For radiation dosimetry calculations of radiolabeled monoclonal antibodies, (MAB), pharmacokinetics are critical. Specifically, pharmacokinetic modeling is a useful component of estimation of cumulated activity in various source organs in the body. It is thus important to formulate general methods of pharmacokinetic m...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.597047
更新日期:1993-03-01 00:00:00
abstract::Breast density, the percentage of glandular breast tissue, has been identified as an important yet underutilized risk factor in the development of breast cancer. A quantitative method to measure breast density with dual energy imaging was investigated using a computer simulation model. Two configurations to measure br...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3002308
更新日期:2008-12-01 00:00:00
abstract:PURPOSE:To demonstrate the feasibility of compressed sensing (CS) to accelerate the acquisition of hyperpolarized (HP) 129 Xe multi-b diffusion MRI for quantitative assessments of lung microstructural morphometry. METHODS:Six healthy subjects and six chronic obstructive pulmonary disease (COPD) subjects underwent HP 1...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12944
更新日期:2018-07-01 00:00:00
abstract::Modern radiotherapy linacs often use carbon fibre for their couch tops due to its radio translucent properties. Beam attenuation by the couches is often ignored during planning and MU calculation. This work examines beam attenuation and loss of "skin sparing" (dose build up region) when various photon beams transit ei...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2965951
更新日期:2008-07-01 00:00:00
abstract:PURPOSE:Monitoring of physiological parameters is a major concern in Intensive Care Units (ICU) given their role in the assessment of vital organ function. Within this context, one issue is the lack of efficient noncontact techniques for respiratory monitoring. In this paper, we present a novel noncontact solution for ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14557
更新日期:2020-10-28 00:00:00
abstract:PURPOSE:To compare esophageal dose distributions in esophageal sparing IMRT plans with predicted dose distributions which include the effect of inter-fraction motion. METHODS:Seven lung cancer patients were used, each with a standard and an esophageal sparing plan (74Gy, 2Gy fractions). The average max dose to esophag...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735647
更新日期:2012-06-01 00:00:00
abstract::An experiment to determine the peak of the energy spectrum of the photon beam from a Toshiba LMR-15 medical linear accelerator is described. It is found that the flattening filters removed much of the bremsstrahlung spectrum below approximately 1 MeV, resulting in a photon spectrum which peaks around 1.2 MeV. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595582
更新日期:1984-11-01 00:00:00
abstract::An analytic expression is derived for the transmission of isotropic scattered radiation incident upon an ideal parallel grid. It is found that the expression for the transmission usually found in the literature overestimates the transmission by approximately a factor of two. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594877
更新日期:1981-11-01 00:00:00
abstract::This paper outlines a method for determining proper removal-diffusion parameters to be used in removal-diffusion theory calculations for the purpose of BNCT treatment planning. Additionally, this paper demonstrates that, given the proper choice of removal-diffusion parameters, removal-diffusion theory may provide an a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1386424
更新日期:2001-09-01 00:00:00
abstract::In proton therapy, it is important to evaluate the field irradiated with protons and the deposited dose distribution in a patient's body. Positron emitters generated through fragmentation reactions of target nuclei can be used for this purpose. By detecting the annihilation gamma rays from the positron emitters, the a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2712572
更新日期:2007-05-01 00:00:00
abstract:PURPOSE:Different approaches have been used in dynamic elastography to assess mechanical properties of biological tissues. Most techniques are based on a simple inversion based on the measurement of the shear wave speed to assess elasticity, whereas some recent strategies use more elaborated analytical or finite elemen...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4942813
更新日期:2016-04-01 00:00:00
abstract::We employed an elastic reservoir filled with tissue-equivalent fluid as an x-ray beam filter for exposure equalization. The filter is designed to be placed between the upper compression plate and the breast. During compression, it will conform to the shape of the peripheral region of the breast and fill the space betw...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596502
更新日期:1990-03-01 00:00:00
abstract::The precision of noninvasive optical measurement of the concentration changes in oxy-, deoxy-, and total-hemoglobin depends on wavelength. For estimating the precision, we calculated the noise level of the concentration changes as the uncertainty in measurements using several wavelength pairs of light. Seven laser dio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1373401
更新日期:2001-06-01 00:00:00
abstract:PURPOSE:Diffusion magnetic resonance imaging (MRI) in combination with functional MRI promises a whole new vista for scientists to investigate noninvasively the structural and functional connectivity of the human brain-the human connectome, which had heretofore been out of reach. As with other imaging modalities, diffu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3700166
更新日期:2012-05-01 00:00:00
abstract::Segmentation of the lungs within magnetic resonance (MR) scans is a necessary step in the computer-based analysis of thoracic MR images. This process is often confounded by image acquisition artifacts and disease-induced morphological deformation. We have developed an automated method for lung segmentation that is ins...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2214165
更新日期:2006-09-01 00:00:00
abstract:PURPOSE:This paper provides a comparison between a fast, commercial, in-patient Monte Carlo dose calculation algorithm (GPUMCD) and geant4. It also evaluates the dosimetric impact of the application of an external 1.5 T magnetic field. METHODS:A stand-alone version of the Elekta™ GPUMCD algorithm, to be used within th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4939808
更新日期:2016-02-01 00:00:00
abstract:PURPOSE:In this article, the authors propose a new gold standard data set for the validation of two-dimensional/three-dimensional (2D/3D) and 3D/3D image registration algorithms. METHODS:A gold standard data set was produced using a fresh cadaver pig head with attached fiducial markers. The authors used several imagin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3553402
更新日期:2011-03-01 00:00:00
abstract::Small photon fields are increasingly used in modern radiotherapy and especially in IMRT and SRS/SRT treatments. The uncertainties related to small field profile measurements can introduce significant systematic errors to the overall treatment process. These measurements are challenging mainly due to the absence of cha...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2977829
更新日期:2008-10-01 00:00:00
abstract::Model-based deformable organ registration techniques using the finite element method (FEM) have recently been investigated intensively and applied to image-guided adaptive radiotherapy (IGART). These techniques assume that human organs are linearly elastic material, and their mechanical properties are predetermined. U...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2163838
更新日期:2006-02-01 00:00:00
abstract::We have developed two prototypes of portable gamma cameras for medical applications based on a previous prototype designed and tested by our group. These cameras use a CsI(Na) continuous scintillation crystal coupled to the new flat-panel-type multianode position-sensitive photomultiplier tube, H8500 from Hamamatsu Ph...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2358199
更新日期:2006-11-01 00:00:00
abstract::We designed a questionnaire to be filled out by the physicist at the time of planning treatment with the aid of a computer in order to assess what was learned during the course of the planning session. We analyzed the results to gauge the impact of the 70 treatment planning sessions conducted during the one month peri...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596302
更新日期:1988-03-01 00:00:00
abstract::Ir-192 wires have been used in low-dose-rate brachytherapy for many years. Commercially available treatment planning systems approximate the dose rate distribution of the straight or curved wires applying the superposition principle using one of the following methods: (i) The wire is modeled as a set of point sources,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2839102
更新日期:2008-03-01 00:00:00
abstract:PURPOSE:A commonly used beam quality index (Q) for high-energy photon beams is the tissue phantom ratio (TPR20,10) for a square field of 10 x 10 cm2 and SDD of 100 cm. On some specialized radiotherapy treatment equipment such a reference collimator setting is not achievable. Likewise a flat beam profile, not explicitly...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3197062
更新日期:2009-09-01 00:00:00
abstract::We adapted a small sodium iodide scintillation detector for rapid, in vivo localization of a lost brachytherapy seed. Using the detector, we were able to locate and remove an Ir-192 seed that was not visible to the unaided eye. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595528
更新日期:1984-07-01 00:00:00
abstract:PURPOSE:To correct for the deviations of the detector response when typical radiation detectors are used under non-reference conditions, factor kNR was calculated from the known energy dependence of the detector response at photon energies from 10 keV upwards and from clinical photon spectra within a large water phanto...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735184
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Computed tomography (CT) and, in particular, cone beam CT (CBCT) have been increasingly used as a diagnostic tool in recent years. Patient motion during acquisition is common in CBCT due to long scan times. This results in degraded image quality and may potentially increase the number of retakes. Our aim was to...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13731
更新日期:2019-10-01 00:00:00
abstract::A novel iterative penalized likelihood algorithm with evolutionary components for the optimization of beamlet fluences for intensity modulated radiation therapy (IMRT) is presented. This algorithm is designed to be flexible in terms of the objective function and automatically escalates dose, as long as the objective f...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1773631
更新日期:2004-08-01 00:00:00
abstract::Energy imparted is a measure of the total ionizing energy deposited in the patient during a radiologic examination and may be used to quantify the patient dose in diagnostic radiology. Values of the energy imparted per unit exposure-area product, omega (z), absorbed by a semi-infinite water phantom with a thickness z,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597939
更新日期:1997-04-01 00:00:00
abstract::Available deformable registration methods are often inaccurate over large organ variation encountered, for example, in the rectum and bladder. The authors developed a novel approach to accurately and effectively register large deformations in the prostate region for adaptive radiation therapy. A software tool combinin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3095777
更新日期:2009-04-01 00:00:00
abstract::The mixed-field dosimetry for 252Cf Applicator Tube (AT) type medical sources available from Oak Ridge National Laboratory (ORNL) has been characterized using ionization chambers, a GM counter, and Monte Carlo methods. Unlike the AAPM Task Group No. 43 (TG-43), specification of dose to muscle instead of water is recom...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598646
更新日期:1999-08-01 00:00:00