Confirmation of a realistic reactor model for BNCT dosimetry at the TRIGA Mainz.

Abstract:

PURPOSE:In order to build up a reliable dose monitoring system for boron neutron capture therapy (BNCT) applications at the TRIGA reactor in Mainz, a computer model for the entire reactor was established, simulating the radiation field by means of the Monte Carlo method. The impact of different source definition techniques was compared and the model was validated by experimental fluence and dose determinations. METHODS:The depletion calculation code origen2 was used to compute the burn-up and relevant material composition of each burned fuel element from the day of first reactor operation to its current core. The material composition of the current core was used in a mcnp5 model of the initial core developed earlier. To perform calculations for the region outside the reactor core, the model was expanded to include the thermal column and compared with the previously established attila model. Subsequently, the computational model is simplified in order to reduce the calculation time. Both simulation models are validated by experiments with different setups using alanine dosimetry and gold activation measurements with two different types of phantoms. RESULTS:The mcnp5 simulated neutron spectrum and source strength are found to be in good agreement with the previous attila model whereas the photon production is much lower. Both mcnp5 simulation models predict all experimental dose values with an accuracy of about 5%. The simulations reveal that a Teflon environment favorably reduces the gamma dose component as compared to a polymethyl methacrylate phantom. CONCLUSIONS:A computer model for BNCT dosimetry was established, allowing the prediction of dosimetric quantities without further calibration and within a reasonable computation time for clinical applications. The good agreement between the mcnp5 simulations and experiments demonstrates that the attila model overestimates the gamma dose contribution. The detailed model can be used for the planning of structural modifications in the thermal column irradiation channel or the use of different irradiation sites than the thermal column, e.g., the beam tubes.

journal_name

Med Phys

journal_title

Medical physics

authors

Ziegner M,Schmitz T,Khan R,Blaickner M,Palmans H,Sharpe P,Hampel G,Böck H

doi

10.1118/1.4897242

subject

Has Abstract

pub_date

2014-11-01 00:00:00

pages

111706

issue

11

eissn

0094-2405

issn

2473-4209

journal_volume

41

pub_type

杂志文章
  • Influence of 0.35 T magnetic field on the response of EBT3 and EBT-XD radiochromic films.

    abstract:PURPOSE:To investigate the inconsistency of recent literature on the effect of magnetic field on the response of radiochromic films, we studied the influence of 0.35 T magnetic field on dosimetric response of EBT3 and EBT-XD GafchromicTM films. METHODS:Two different models of radiochromic films, EBT3 and EBT-XD, were ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14313

    authors: Darafsheh A,Hao Y,Maraghechi B,Cammin J,Reynoso FJ,Khan R

    更新日期:2020-09-01 00:00:00

  • A time-domain wavelet-based approach for fluorescence diffuse optical tomography.

    abstract:PURPOSE:In the context of fluorescence diffuse optical tomography, determining the optimal way to exploit the time-resolved information has been receiving much attention and different features of the time-resolved signals have been introduced. In this article, the authors revisit and generalize the notion of feature, c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3431571

    authors: Ducros N,Da Silva A,Dinten JM,Seelamantula CS,Unser M,Peyrin F

    更新日期:2010-06-01 00:00:00

  • A feasible method for clinical delivery verification and dose reconstruction in tomotherapy.

    abstract::Delivery verification is the process in which the energy fluence delivered during a treatment is verified. This verified energy fluence can be used in conjunction with an image in the treatment position to reconstruct the full three-dimensional dose deposited. A method for delivery verification that utilizes a measure...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1352579

    authors: Kapatoes JM,Olivera GH,Ruchala KJ,Smilowitz JB,Reckwerdt PJ,Mackie TR

    更新日期:2001-04-01 00:00:00

  • Performance characteristics of an orthovoltage x-ray therapy machine.

    abstract::Performance characteristics sufficient to provide physical data base specific to the Siemen's Stabilipan 2 orthovoltage x-ray therapy machine are presented. Operating conditions covering the working range of the unit from 100 to 300 kVp are selected. Beam quality, output, the central axis depth dose, relative output f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596016

    authors: Niroomand-Rad A,Gillin MT,Lopez F,Grimm DF

    更新日期:1987-09-01 00:00:00

  • MO-A-217BCD-01: Internal Emitter Dose Estimation.

    abstract::Tissue absorbed dose (D) is a computed result for internal emitters. For fixed geometries, D is calculated by a matrix (S) multiplication of the integrated activity vector (Ã). The last quantity is usually measured by nuclear imaging of activity in various source organs and performing a temporal integration. Ã is the ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735750

    authors: Williams L

    更新日期:2012-06-01 00:00:00

  • Comparison of p-type commercial electron diodes for in vivo dosimetry.

    abstract::This paper compares the characteristics of three types of commercial p-type electron diodes specially designed for in vivo dosimetry (Scanditronix EDD2, Sun Nuclear QED 111200-0 and PTW T60010E diodes coupled with a Therados DPD510 dosimeter) in electron fields with energies from 4.5 to 21 MeV, and in conditions simil...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1630492

    authors: Marre D,Marinello G

    更新日期:2004-01-01 00:00:00

  • Controlled mold geometry for surgical deficit treatment planning.

    abstract::The relatively precise placement of brachytherapy sources afforded by stereotactic frames for brain implants is not generally achievable for other sites, which lack the fixed geometry of the cranium and its contents. An exception is a source-containing rigid mold that delivers brachytherapy when inserted securely in a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597454

    authors: Anderson LL,Zlotolow IM,McCormick B,Harrison LB

    更新日期:1995-03-01 00:00:00

  • Dose distributions around cylindrical 241Am sources for a clinical intracavitary applicator.

    abstract::Encapsulated, cylindrical sources containing 2, 5, and 8 Ci of 241Am have been designed and fabricated for intracavitary irradiation of uterine cancers. Exposure rates in air and dose rates in water around these sources have been measured using an ionization chamber and a lithium fluoride thermoluminescent dosimetry s...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596007

    authors: Nath R,Gray L,Park CH

    更新日期:1987-09-01 00:00:00

  • Comparison of breast density measured on MR images acquired using fat-suppressed versus nonfat-suppressed sequences.

    abstract:PURPOSE:To investigate the difference of MR percent breast density measured from fat-suppressed versus nonfat-suppressed imaging sequences. METHODS:Breast magnetic resonance imaging (MRI) with and without fat suppression was acquired from 38 subjects. Breasts were divided into subgroups of different morphological patt...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3646756

    authors: Chang DH,Chen JH,Lin M,Bahri S,Yu HJ,Mehta RS,Nie K,Hsiang DJ,Nalcioglu O,Su MY

    更新日期:2011-11-01 00:00:00

  • Technical Note: Comparison of megavoltage, dual-energy, and single-energy CT-based μ-maps for a four-channel breast coil in PET/MRI.

    abstract:PURPOSE:The purpose of this study was to describe and evaluate methods for calculating a megavoltage computed tomography (MVCT)-derived MR hardware attenuation map (μ-map) and dual-energy CT (DECT) for 511 keV photons. METHODS:Phantom measurements were acquired on a whole-body hybrid PET/MRI system, using a four-chann...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12407

    authors: Patrick JC,Terry Thompson R,So A,Butler J,Faul D,Stodilka RZ,Yartsev S,Prato FS,Gaede S

    更新日期:2017-09-01 00:00:00

  • Learning-based automated segmentation of the carotid artery vessel wall in dual-sequence MRI using subdivision surface fitting.

    abstract:PURPOSE:The quantification of vessel wall morphology and plaque burden requires vessel segmentation, which is generally performed by manual delineations. The purpose of our work is to develop and evaluate a new 3D model-based approach for carotid artery wall segmentation from dual-sequence MRI. METHODS:The proposed me...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12476

    authors: Gao S,van 't Klooster R,Kitslaar PH,Coolen BF,van den Berg AM,Smits LP,Shahzad R,Shamonin DP,de Koning PJH,Nederveen AJ,van der Geest RJ

    更新日期:2017-10-01 00:00:00

  • Evaluation of inherent gray-level dynamic range in a digital image using the runs test and join-count statistics.

    abstract::The dynamic range of the gray level of a digital image is limited by the noise it contains. Two statistical methods called "runs test" and "join-count statistic" are used to measure the noise level in a digital image. A residual image is formed by subtracting an original image from its smoothed version. Theoretically,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597058

    authors: Chuang KS,Huang HK

    更新日期:1993-01-01 00:00:00

  • Re-examining TG-142 recommendations in light of modern techniques for linear accelerator based radiosurgery.

    abstract:PURPOSE:The recent development of multifocal stereotactic radiosurgery (SRS) using a single isocenter volumetric modulated arc theory (VMAT) technique warrants a re-examination of the quality assurance (QA) tolerances for routine mechanical QA recommended by the American Association of Physicists in Medicine Task Group...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4962471

    authors: Faught AM,Trager M,Yin FF,Kirkpatrick J,Adamson J

    更新日期:2016-10-01 00:00:00

  • "Battered data"--some clinical effects of the abuse of multiple regression methods: the NSD.

    abstract::The NSD equation, D = 1850 x T0.11 x N0.24, is a celebrated transmogrification of Cohen's two well-known collations of data on response to clinical irradiations (3 degrees erythema and 0.90 ablation of skin cancer) in which the relation of D and T is fixed by the data selected by Cohen and the additional constraint th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595034

    authors: Herbert DE Jr

    更新日期:1981-11-01 00:00:00

  • Technical Note: Impact of region of interest size and location in Gafchromic film dosimetry.

    abstract:PURPOSE:To evaluate dependence of measured dose on size and location of region of interest (ROI) in Gafchromic EBT3 film dosimetry. METHODS:Gafchromic EBT3 films were irradiated perpendicularly using the 6MV beam from a linear accelerator at 10 cm depth (100 cm SSD) of a 30 × 30 × 20 cm3 solid water phantom for a rang...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12885

    authors: Gholizadeh Sendani N,Karimian A,Ferreira C,Alaei P

    更新日期:2018-05-01 00:00:00

  • Sci-Thur AM: Planning - 10: Improved dosimetric accuracy for patient specific quality assurance using a dual-detector measurement method for cyberknife output factors.

    abstract::The measurement of output factors for small fields is challenging and can lead to large dose errors in patient treatments if corrections for detector size and scatter from high-Z material are not applied. Due to its high spatial resolution and near tissue equivalence, GAFCHROMIC® film potentially provides a correction...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740095

    authors: Vandervoort E,La Russa D,Ploquin N,Kadir IAE,Szanto J

    更新日期:2012-07-01 00:00:00

  • X-ray imaging technique for in vitro tissue composition measurements using saline/iodine displacement: technique optimization.

    abstract::An in vitro radiographic technique which uses saline/iodine displacement has been developed to study the thickness of bone-equivalent and soft-tissue-equivalent materials within atherosclerotic plaques in arterial specimens which have been cut open longitudinally and laid flat. Results concerning the optimization of t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597916

    authors: Moreau M,Holdsworth DW,Fenster A

    更新日期:1997-01-01 00:00:00

  • Anatomy-based three-dimensional dose optimization in brachytherapy using multiobjective genetic algorithms.

    abstract::In conventional dose optimization algorithms, in brachytherapy, multiple objectives are expressed in terms of an aggregating function which combines individual objective values into a single utility value, making the problem single objective, prior to optimization. A multiobjective genetic algorithm (MOGA) was develop...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598697

    authors: Lahanas M,Baltas D,Zamboglou N

    更新日期:1999-09-01 00:00:00

  • WE-G-217A-08: Routine ACR SNR Measurement Failed to Detect 32-Channel Head Coil Receiver Malfunction.

    abstract:PURPOSE:To study if malfunction of a receiver can be detected robustly using the simple ACR SNR measurement approach on a 32-channel head coil. METHODS:Standard ACR T1W images (11slice) were acquired with a commercial 32 channel head coil on a 3T Philips Achieva MR scanner following the ACR recommended setup. Raw data...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736227

    authors: Peng Q

    更新日期:2012-06-01 00:00:00

  • Measurements and calculations of the absorbed dose distribution around a 60Co source.

    abstract::The data from Meisberger et al. [Radiology 90, 953-957 (1968)] are often used as a basis for dose calculations in brachytherapy. In order to describe the absorbed dose in water around a brachytherapy point source, Meisberger provided a polynomial fit for different isotopes taking into account the effect of attenuation...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597583

    authors: Tiourina TB,Dries WJ,van der Linden PM

    更新日期:1995-05-01 00:00:00

  • Feature selection using factor analysis for Alzheimer's diagnosis using 18F-FDG PET images.

    abstract:PURPOSE:This article presents a computer-aided diagnosis technique for improving the accuracy of the early diagnosis of Alzheimer's disease (AD). Two hundred and ten 18F-FDG PET images from the ADNI initiative [52 normal controls (NC), 114 mild cognitive impairment (MCI), and 53 AD subjects] are studied. METHODS:The p...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3488894

    authors: Salas-Gonzalez D,Górriz JM,Ramírez J,Illán IA,López M,Segovia F,Chaves R,Padilla P,Puntonet CG

    更新日期:2010-11-01 00:00:00

  • Beam properties and stability of a flattening-filter free 7 MV beam-an overview.

    abstract:PURPOSE:Several works have recently focused on flattening-filter-free (FFF) beams of linear accelerators of various companies (in particular, Varian and Elekta), but no overview as yet exists for the flattening-filter free 7XU beam (Siemens Artiste). METHODS:Dosimetric properties of the 7XU beam were measured in May a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3703835

    authors: Dzierma Y,Licht N,Nuesken F,Ruebe C

    更新日期:2012-05-01 00:00:00

  • Dosimetric properties of the new 125I BrachySeed model LS-1 source.

    abstract::The BrachySeed model LS-1 is one of the latest in a series of new brachytherapy 125I seeds that have recently become available commercially for interstitial implants. The dosimetric properties of the seed were investigated analytically, experimentally, and by Monte Carlo simulation. Following the AAPM Task Group 43 fo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1445411

    authors: Chan GH,Prestwich WV

    更新日期:2002-02-01 00:00:00

  • 3T MRI evaluation of the accuracy of atlas-based subthalamic nucleus identification.

    abstract::Modulation of the activity of the subthalamic nucleus (STN) using deep brain stimulation (DBS) in patients with advanced Parkinson's disease is the most common procedure performed today by functional neurosurgeons. The STN contours cannot be entirely identified on common 1.5 T images; in particular, the ventromedial b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2936229

    authors: Stancanello J,Muacevic A,Sebastiano F,Modugno N,Cerveri P,Ferrigno G,Uggeri F,Romanelli P

    更新日期:2008-07-01 00:00:00

  • X-ray imaging with amorphous selenium: X-ray to charge conversion gain and avalanche multiplication gain.

    abstract::Fluoroscopy is a low dose imaging technique. As such, a very sensitive detector is required to create images of good quality. Present day flat panel active matrix read out systems introduce an amount of noise that inhibits present direct and indirect methods from producing optimal quality images at fluoroscopic exposu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1513157

    authors: Hunt DC,Kirby SS,Rowlands JA

    更新日期:2002-11-01 00:00:00

  • Principles in positioning cross-projecting lasers.

    abstract::With the increased sophistication of lasers used for patient positioning in radiotherapy comes increased possibilities for mistakes in installing the lasers, which can result in serious patient positioning errors. Two principles must be followed when mounting cross-projecting lasers: (1) the horizontal line must be on...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594960

    authors: Thomadsen BR

    更新日期:1981-05-01 00:00:00

  • On the development of consensus values of reference dosimetry parameters for interstitial brachytherapy sources.

    abstract::The American Association of Physicists in Medicine recommends that the reference dose-rate distribution, used for treatment planning for low-energy photon brachytherapy sources in routine clinical use, must be based on at least two independent determinations: one using experimentally measured dose rates and one using ...

    journal_title:Medical physics

    pub_type: 指南,杂志文章

    doi:10.1118/1.1690712

    authors: Chan GH,Nath R,Williamson JF,American Association of Physicists in Medicine.

    更新日期:2004-05-01 00:00:00

  • Direct aperture optimization: a turnkey solution for step-and-shoot IMRT.

    abstract::IMRT treatment plans for step-and-shoot delivery have traditionally been produced through the optimization of intensity distributions (or maps) for each beam angle. The optimization step is followed by the application of a leaf-sequencing algorithm that translates each intensity map into a set of deliverable aperture ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1477415

    authors: Shepard DM,Earl MA,Li XA,Naqvi S,Yu C

    更新日期:2002-06-01 00:00:00

  • Evaluating IMRT and VMAT dose accuracy: practical examples of failure to detect systematic errors when applying a commonly used metric and action levels.

    abstract:PURPOSE:This study (1) examines a variety of real-world cases where systematic errors were not detected by widely accepted methods for IMRT/VMAT dosimetric accuracy evaluation, and (2) drills-down to identify failure modes and their corresponding means for detection, diagnosis, and mitigation. The primary goal of detai...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4826166

    authors: Nelms BE,Chan MF,Jarry G,Lemire M,Lowden J,Hampton C,Feygelman V

    更新日期:2013-11-01 00:00:00

  • Absorbed dose in the presence of contrast agents during pediatric cardiac catheterization.

    abstract::Administration of x-ray contrast agents during heart catheterization examination increases the absorbed radiation dose in tissue. To estimate the dose absorbed by the blood of children undergoing diagnostic heart catheterization and angiocardiography, a number of measurements and calculations were conducted. First, en...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594613

    authors: Callisen HH,Norman A,Adams FH

    更新日期:1979-11-01 00:00:00