On the development of consensus values of reference dosimetry parameters for interstitial brachytherapy sources.

Abstract:

:The American Association of Physicists in Medicine recommends that the reference dose-rate distribution, used for treatment planning for low-energy photon brachytherapy sources in routine clinical use, must be based on at least two independent determinations: one using experimentally measured dose rates and one using Monte Carlo simulation dosimetry techniques. In this work, we present an approach for developing consensus dosimetry parameters from various independent reference dosimetry studies for interstitial brachytherapy sources. This approach is applied to four recently published papers on the dosimetric properties of the BrachySeed Model LS-1 125I seed. Consensus values for the dose-rate constant, radial dose function, and anisotropy parameters are presented for the LS-1 Model 125I seed.

journal_name

Med Phys

journal_title

Medical physics

authors

Chan GH,Nath R,Williamson JF,American Association of Physicists in Medicine.

doi

10.1118/1.1690712

subject

Has Abstract

pub_date

2004-05-01 00:00:00

pages

1040-5

issue

5

eissn

0094-2405

issn

2473-4209

journal_volume

31

pub_type

指南,杂志文章
  • Off-axis beam quality change in linear accelerator x-ray beams.

    abstract::The effective energy of the x-ray beam from linear accelerators changes as a function of the position in the beam due to nonuniform filtration by the flattening filter. In this work, the transmittance through a water column was measured in good geometry and the beam quality characterized in units of HVL in water. Meas...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594677

    authors: Hanson WF,Berkley LW,Peterson M

    更新日期:1980-03-01 00:00:00

  • Daily check instrument for photon and electron beam quality assurance of medical linacs.

    abstract::An instrument for daily beam checks of medical accelerators is described. Using three silicon diodes, the instrument provides information about calibration, beam symmetry, flatness, and energy variation for both photon and electron beams. Operating characteristics of the instrument and the electronic circuit design pe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595756

    authors: Lutz WR,Maddox BJ,Kase KR

    更新日期:1985-07-01 00:00:00

  • Effect of respiratory gating on reducing lung motion artifacts in PET imaging of lung cancer.

    abstract::Positron emission tomography (PET) has shown an increase in both sensitivity and specificity over computed tomography (CT) in lung cancer. However, motion artifacts in the 18F fluorodioxydoglucose (FDG) PET images caused by respiration persists to be an important factor in degrading PET image quality and quantificatio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1448824

    authors: Nehmeh SA,Erdi YE,Ling CC,Rosenzweig KE,Squire OD,Braban LE,Ford E,Sidhu K,Mageras GS,Larson SM,Humm JL

    更新日期:2002-03-01 00:00:00

  • A novel approach in electron beam radiation therapy of lips carcinoma: a Monte Carlo study.

    abstract:PURPOSE:Squamous cell carcinoma (SCC) is commonly treated by electron beam radiotherapy (EBRT) followed by a boost via brachytherapy. Considering the limitations associated with brachytherapy, in this study, a novel boosting technique in EBRT of lip carcinoma using an internal shield as an internal dose enhancer tool (...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4795756

    authors: Shokrani P,Baradaran-Ghahfarokhi M,Zadeh MK

    更新日期:2013-04-01 00:00:00

  • Leakage and scatter radiation from a double scattering based proton beamline.

    abstract::Proton beams offer several advantages over conventional radiation techniques for treating cancer and other diseases. These advantages might be negated if the leakage and scatter radiation from the beamline and patient are too large. Although the leakage and scatter radiation for the double scattering proton beamlines ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2805086

    authors: Moyers MF,Benton ER,Ghebremedhin A,Coutrakon G

    更新日期:2008-01-01 00:00:00

  • Joint model of motion and anatomy for PET image reconstruction.

    abstract::Anatomy-based positron emission tomography (PET) image enhancement techniques have been shown to have the potential for improving PET image quality. However, these techniques assume an accurate alignment between the anatomical and the functional images, which is not always valid when imaging the chest due to respirato...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2804721

    authors: Qiao F,Pan T,Clark JW Jr,Mawlawi O

    更新日期:2007-12-01 00:00:00

  • Average glandular dose coefficients for pendant-geometry breast CT using realistic breast phantoms.

    abstract:PURPOSE:To design volume-specific breast phantoms from breast CT (bCT) data sets and estimate the associated normalized mean glandular dose coefficients for breast CT using Monte Carlo methods. METHODS:A large cohort of bCT data sets (N = 215) was used to evaluate breast volume into quintiles (plus the top 5%). The av...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12477

    authors: Hernandez AM,Boone JM

    更新日期:2017-10-01 00:00:00

  • Toward adaptive radiotherapy for head and neck patients: Uncertainties in dose warping due to the choice of deformable registration algorithm.

    abstract:PURPOSE:The aims of this work were to evaluate the performance of several deformable image registration (DIR) algorithms implemented in our in-house software (NiftyReg) and the uncertainties inherent to using different algorithms for dose warping. METHODS:The authors describe a DIR based adaptive radiotherapy workflow...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4905050

    authors: Veiga C,Lourenço AM,Mouinuddin S,van Herk M,Modat M,Ourselin S,Royle G,McClelland JR

    更新日期:2015-02-01 00:00:00

  • Observation and correction of transient cavitation-induced PRFS thermometry artifacts during radiofrequency ablation, using simultaneous ultrasound/MR imaging.

    abstract:PURPOSE:MR thermometry based on the proton resonance frequency shift (PRFS) is the most commonly used method for the monitoring of thermal therapies. As the chemical shift of water protons is temperature dependent, the local temperature variation (relative to an initial baseline) may be calculated from time-dependent p...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3309439

    authors: Viallon M,Terraz S,Roland J,Dumont E,Becker CD,Salomir R

    更新日期:2010-04-01 00:00:00

  • A novel approach to neutron dosimetry.

    abstract:PURPOSE:Having been overlooked for many years, research is now starting to take into account the directional distribution of neutron workplace fields. Existing neutron dosimetry instrumentation does not account for this directional distribution, resulting in conservative estimates of dose in neutron workplace fields (b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4964456

    authors: Balmer MJ,Gamage KA,Taylor GC

    更新日期:2016-11-01 00:00:00

  • Phantom size in brachytherapy source dosimetric studies.

    abstract::An important point to consider in a brachytherapy dosimetry study is the phantom size involved in calculations or experimental measurements. As pointed out by Williamson [Med. Phys. 18, 776-786 (1991)] this topic has a relevant influence on final dosimetric results. Presently, one-dimensional (1-D) algorithms and newl...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1759826

    authors: Pérez-Calatayud J,Granero D,Ballester F

    更新日期:2004-07-01 00:00:00

  • The effect of pitch in multislice spiral/helical CT.

    abstract::The purpose of this study is to understand the effect of pitch on raw data interpolation in multislice spiral/helical computed tomography (CT) and provide guidelines for scanner design and protocol optimization. Multislice spiral CT is mainly characterized by the three parameters: the number of detector arrays, the de...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598804

    authors: Wang G,Vannier MW

    更新日期:1999-12-01 00:00:00

  • An improved bolus configuration for commercial multielement ultrasound and microwave hyperthermia systems.

    abstract::A simple modification is presented for two commercially available hyperthermia applicators which dramatically improves the regulation and dynamic control of the temperature at the bolus/tissue interface. This alteration requires the addition of a variable speed pump, bubble trap, simple heat exchanger, and a few minor...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597196

    authors: Diederich CJ,Stauffer PR,Bozzo D

    更新日期:1994-09-01 00:00:00

  • Dose sculpting with generalized equivalent uniform dose.

    abstract::With intensity-modulated radiotherapy (IMRT), a variety of user-defined dose distribution can be produced using inverse planning. The generalized equivalent uniform dose (gEUD) has been used in IMRT optimization as an alternative objective function to the conventional dose-volume-based criteria. The purpose of this st...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1897464

    authors: Wu Q,Djajaputra D,Liu HH,Dong L,Mohan R,Wu Y

    更新日期:2005-05-01 00:00:00

  • An observer study comparing spot imaging regions selected by radiologists and a computer for an automated stereo spot mammography technique.

    abstract::We are developing an automated stereo spot mammography technique for improved imaging of suspicious dense regions within digital mammograms. The technique entails the acquisition of a full-field digital mammogram, automated detection of a suspicious dense region within that mammogram by a computer aided detection (CAD...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1737492

    authors: Goodsitt MM,Chan HP,Lydick JT,Gandra CR,Chen NG,Helvie MA,Bailey JE,Roubidoux MA,Paramagul C,Blane CE,Sahiner B,Petrick NA

    更新日期:2004-06-01 00:00:00

  • Reduced order constrained optimization (ROCO): clinical application to lung IMRT.

    abstract:PURPOSE:The authors use reduced-order constrained optimization (ROCO) to create clinically acceptable IMRT plans quickly and automatically for advanced lung cancer patients. Their new ROCO implementation works with the treatment planning system and full dose calculation used at Memorial Sloan-Kettering Cancer Center (M...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3575416

    authors: Stabenau H,Rivera L,Yorke E,Yang J,Lu R,Radke RJ,Jackson A

    更新日期:2011-05-01 00:00:00

  • Measurements of the neutron yields from 7Li(p,n)7Be reaction (thick target) with incident energies from 1.885 to 2.0 MeV.

    abstract::Accelerator-based neutron source have been considered to be practical for boron neutron capture therapy (BNCT). Based on experience with a parameters of the Brookhaven National Laboratory BMRR reactor neutron source, which has been used in treatment experiments, the future accelerator-based neutron source for BNCT sho...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598299

    authors: Yu W,Yue G,Han X,Chen J,Tian B

    更新日期:1998-07-01 00:00:00

  • A correction-based dose calculation algorithm for kilovoltage x rays.

    abstract::Frequent and repeated imaging procedures such as those performed in image-guided radiotherapy (IGRT) programs may add significant dose to radiosensitive organs of radiotherapy patients. It has been shown that kV-CBCT results in doses to bone that are up to a factor of 3-4 higher than those in surrounding soft tissue. ...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1118/1.3014197

    authors: Ding GX,Pawlowski JM,Coffey CW

    更新日期:2008-12-01 00:00:00

  • SU-E-T-231: Comparison of Beam Characteristics of Small Field 6 MeV Electrons as Replacement for Superficial X Ray Beam.

    abstract:PURPOSE:To compare beam characteristics of superficial X-rays with 6 MeV Electrons for the purpose of replacing superficial treatments with electron fields for skin lesions. METHODS:Electron beam cutouts were made with 12mm thickness cerrobend in diameters 2-5 cm to match superficial X-ray machine cones. Central axis ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735294

    authors: Avadhani J,Sasidharan S,Carton C,Lowen M,Klapproth T,Licitra C

    更新日期:2012-06-01 00:00:00

  • JADA: a graphical user interface for comprehensive internal dose assessment in nuclear medicine.

    abstract:PURPOSE:The main objective of this work was to design a comprehensive dosimetry package that would keep all aspects of internal dose calculation within the framework of a single software environment and that would be applicable for a variety of dose calculation approaches. METHODS:Our MATLAB-based graphical user inter...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4810963

    authors: Grimes J,Uribe C,Celler A

    更新日期:2013-07-01 00:00:00

  • Feasibility of estimating regional mechanical properties of cerebral aneurysms in vivo.

    abstract:PURPOSE:In this article, the authors studied the feasibility of estimating regional mechanical properties in cerebral aneurysms, integrating information extracted from imaging and physiological data with generic computational models of the arterial wall behavior. METHODS:A data assimilation framework was developed to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3355933

    authors: Balocco S,Camara O,Vivas E,Sola T,Guimaraens L,Gratama van Andel HA,Majoie CB,Pozo JM,Bijnens BH,Frangi AF

    更新日期:2010-04-01 00:00:00

  • A quality assurance program for monitor unit calculators.

    abstract::A quality assurance protocol has been developed to assess the relative accuracy of computerized monitor unit calculations. Results from this testing reveal that errors (defined as the difference between the computer results and those obtained using a standard formula with manual calculation) in monitor unit calculator...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596539

    authors: Dahl RA,McCullough EC,Mellenberg DE

    更新日期:1990-01-01 00:00:00

  • Patient specific optimization of the relation between CT-hounsfield units and proton stopping power with proton radiography.

    abstract::The purpose of this work is to show the feasibility of using in vivo proton radiography of a radiotherapy patient for the patient individual optimization of the calibration from CT-Hounsfield units to relative proton stopping power. Water equivalent tissue (WET) calibrated proton radiographs of a dog patient treated f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1833041

    authors: Schneider U,Pemler P,Besserer J,Pedroni E,Lomax A,Kaser-Hotz B

    更新日期:2005-01-01 00:00:00

  • Neutron energy spectra and dose-distribution spectra of cyclotron-produced neutron beams.

    abstract::Neutron energy spectra and spectra of dose deposition in tissue-equivalent material have been measured for neutron sources produced by 16-, 22-, 35-, and 45.5-MeV deuterons and 22.5-, 35-, 45-, and 65.5-MeV protons incident upon a thick beryllium target. Neutron spectra were measured using time-of-flight techniques an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594392

    authors: Heintz PH,Johnsen SW,Peek NF

    更新日期:1977-05-01 00:00:00

  • High resolution digital autoradiographic and dosimetric analysis of heterogeneous radioactivity distribution in xenografted prostate tumors.

    abstract:PURPOSE:The first main aim of this study was to illustrate the absorbed dose rate distribution from 177Lu in sections of xenografted prostate cancer (PCa) tumors using high resolution digital autoradiography (DAR) and compare it with hypothetical identical radioactivity distributions of 90Y or 7 MeV alpha-particles. Th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4967877

    authors: Timmermand OV,Nilsson J,Strand SE,Elgqvist J

    更新日期:2016-12-01 00:00:00

  • Use of capillary optics as a beam intensifier for a Compton x-ray source.

    abstract::The use of Kumakhov capillary optics will significantly enhance the performance of near-monochromatic, Compton backscattered x-ray programs. The Vanderbilt University Medical Free-Electron Laser Center is developing the capability to create these tunable x rays for medical imaging. The present transport has only refle...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597218

    authors: Tompkins PA,Abreu CC,Carroll FE,Xiao QF,MacDonald CA

    更新日期:1994-11-01 00:00:00

  • Effect of phantom voxelization in CT simulations.

    abstract::In computer simulations of x-ray CT systems one can either use continuous geometrical descriptions for phantoms or a voxelized representation. The voxelized approach allows arbitrary phantoms to be defined without being confined to geometrical shapes. The disadvantage of the voxelized approach is that inherent errors ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1461841

    authors: Goertzen AL,Beekman FJ,Cherry SR

    更新日期:2002-04-01 00:00:00

  • Sci-Thur PM: YIS - 08: The effect of copper conversion plates on low-Z target image quality.

    abstract::Current generation electronic portal imaging devices (EPID) contain a 1.0 mm copper conversion plate to increase detection efficiency of a therapeutic megavoltage spectrum. When using these EPIDs for low-Z target imaging, the conversion plate largely attenuates the large populations of diagnostic energy photons, there...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740105

    authors: Parsons D,Robar JL

    更新日期:2012-07-01 00:00:00

  • Evaluation of deformable registration of patient lung 4DCT with subanatomical region segmentations.

    abstract::Deformable registration is needed for a variety of tasks in establishing the voxel correspondence between respiratory phases. Most registration algorithms assume or imply that the deformation field is smooth and continuous everywhere. However, the lungs are contained within closed invaginated sacs called pleurae and a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2828378

    authors: Wu Z,Rietzel E,Boldea V,Sarrut D,Sharp GC

    更新日期:2008-02-01 00:00:00

  • A new fast and fully automated software based algorithm for extracting respiratory signal from raw PET data and its comparison to other methods.

    abstract:PURPOSE:Respiratory gating in PET is an approach used to minimize the negative effects of respiratory motion on spatial resolution. It is based on an initial determination of a patient's respiratory movements during a scan, typically using hardware based systems. In recent years, several fully automated databased algor...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3483784

    authors: Kesner AL,Kuntner C

    更新日期:2010-10-01 00:00:00