Effect of respiratory gating on reducing lung motion artifacts in PET imaging of lung cancer.

Abstract:

:Positron emission tomography (PET) has shown an increase in both sensitivity and specificity over computed tomography (CT) in lung cancer. However, motion artifacts in the 18F fluorodioxydoglucose (FDG) PET images caused by respiration persists to be an important factor in degrading PET image quality and quantification. Motion artifacts lead to two major effects: First, it affects the accuracy of quantitation, producing a reduction of the measured standard uptake value (SUV). Second, the apparent lesion volume is overestimated. Both impact upon the usage of PET images for radiation treatment planning. The first affects the visibility, or contrast, of the lesion. The second results in an increase in the planning target volume, and consequently a greater radiation dose to the normal tissues. One way to compensate for this effect is by applying a multiple-frame capture technique. The PET data are then acquired in synchronization with the respiratory motion. Reduction in smearing due to gating was investigated in both phantoms and patient studies. Phantom studies showed a dependence of the reduction in smearing on the lesion size, the motion amplitude, and the number of bins used for data acquisition. These studies also showed an improvement in the target-to-background ratio, and a more accurate measurement of the SUV. When applied to one patient, respiratory gating showed a 28% reduction in the total lesion volume, and a 56.5% increase in the SUV. This study was conducted as a proof of principle that a gating technique can effectively reduce motion artifacts in PET image acquisition.

journal_name

Med Phys

journal_title

Medical physics

authors

Nehmeh SA,Erdi YE,Ling CC,Rosenzweig KE,Squire OD,Braban LE,Ford E,Sidhu K,Mageras GS,Larson SM,Humm JL

doi

10.1118/1.1448824

subject

Has Abstract

pub_date

2002-03-01 00:00:00

pages

366-71

issue

3

eissn

0094-2405

issn

2473-4209

journal_volume

29

pub_type

杂志文章
  • WE-E-217BCD-02: Update on the Upcoming ACR Digital Mammography QC Manual.

    abstract:PURPOSE:We propose a new metric called Distance Discordance (DD), which is defined as the distance between two anatomic points from two moving images, which are co-located on some reference image, when deformed onto another reference image. METHODS:To demonstrate the concept of DD, we created a reference software phan...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736139

    authors: Berns E

    更新日期:2012-06-01 00:00:00

  • WE-G-BRB-03: On the Detectability of Jaw Decalibrations with the DAVID System.

    abstract:PURPOSE:To evaluate if the recently described problems with the calibration of jaws at Varian linear accelerators can be detected with the DAVID system. METHODS:Recently Varian Clinac field size issues resulted in a widespread medical device correction notice, stating that incorrect jaw positioning due to excessive co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736189

    authors: Poppe B,Looe H,Harder D

    更新日期:2012-06-01 00:00:00

  • Computerized analysis of radiographic bone patterns: effect of imaging conditions on performance.

    abstract::We are developing computerized methods for characterizing the bone texture pattern from digitized skeletal radiographs. For this method to be useful clinically, it must be able to distinguish between weak and strong bone under the range of exposure conditions potentially encountered in the clinical setting. In this st...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598858

    authors: Chinander MR,Giger ML,Martell JM,Favus MJ

    更新日期:2000-01-01 00:00:00

  • Magnetic resonance and ultrasound image-guided navigation system using a needle manipulator.

    abstract:PURPOSE:Image guidance is crucial for percutaneous tumor ablations, enabling accurate needle-like applicator placement into target tumors while avoiding tissues that are sensitive to injury and/or correcting needle deflection. Although ultrasound (US) is widely used for image guidance, magnetic resonance (MR) is prefer...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13958

    authors: Yamada A,Tokuda J,Naka S,Murakami K,Tani T,Morikawa S

    更新日期:2020-03-01 00:00:00

  • Determination of the initial beam parameters in Monte Carlo linac simulation.

    abstract::For Monte Carlo linac simulations and patient dose calculations, it is important to accurately determine the phase space parameters of the initial electron beam incident on the target. These parameters, such as mean energy and radial intensity distribution, have traditionally been determined by matching the calculated...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2168433

    authors: Aljarrah K,Sharp GC,Neicu T,Jiang SB

    更新日期:2006-04-01 00:00:00

  • Liver segmentation in contrast enhanced CT data using graph cuts and interactive 3D segmentation refinement methods.

    abstract:PURPOSE:Liver segmentation is an important prerequisite for the assessment of liver cancer treatment options like tumor resection, image-guided radiation therapy (IGRT), radiofrequency ablation, etc. The purpose of this work was to evaluate a new approach for liver segmentation. METHODS:A graph cuts segmentation metho...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3682171

    authors: Beichel R,Bornik A,Bauer C,Sorantin E

    更新日期:2012-03-01 00:00:00

  • Low-dose dynamic myocardial perfusion CT imaging using a motion adaptive sparsity prior.

    abstract:PURPOSE:Dynamic myocardial perfusion computed tomography (DM-PCT) imaging offers benefits over quantitative assessment of myocardial blood flow (MBF) for diagnosis and risk stratification of coronary artery disease. However, one major drawback of DM-PCT imaging is that a high radiation level is imparted by repeated sca...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12285

    authors: Bian Z,Zeng D,Zhang Z,Gong C,Tian X,Yan G,Huang J,Guo H,Chen B,Zhang J,Feng Q,Chen W,Ma J

    更新日期:2017-09-01 00:00:00

  • Isotope specific resolution recovery image reconstruction in high resolution PET imaging.

    abstract:PURPOSE:Measuring and incorporating a scanner-specific point spread function (PSF) within image reconstruction has been shown to improve spatial resolution in PET. However, due to the short half-life of clinically used isotopes, other long-lived isotopes not used in clinical practice are used to perform the PSF measure...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4870985

    authors: Kotasidis FA,Angelis GI,Anton-Rodriguez J,Matthews JC,Reader AJ,Zaidi H

    更新日期:2014-05-01 00:00:00

  • Scattered photons produced by beam-modifying filters.

    abstract::When a beam-modifying filter such as a wedge or a compensator is placed in an x-ray beam, scattered photons are generated in the filter material. The magnitude of the dose contribution from these photons for a 4-MV x-ray beam was measured. At a distance of 30 cm from the filter, a copper sheet of 1-cm thickness produc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595923

    authors: Huang PH,Chin LM,Bjärngard BE

    更新日期:1986-01-01 00:00:00

  • Characterization of statistical prior image constrained compressed sensing (PICCS): II. Application to dose reduction.

    abstract:PURPOSE:The ionizing radiation imparted to patients during computed tomography exams is raising concerns. This paper studies the performance of a scheme called dose reduction using prior image constrained compressed sensing (DR-PICCS). The purpose of this study is to characterize the effects of a statistical model of x...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4773866

    authors: Lauzier PT,Chen GH

    更新日期:2013-02-01 00:00:00

  • Evaluation of diffusion models in breast cancer.

    abstract:PURPOSE:The purpose of this study is to investigate whether the microvascular pseudodiffusion effects resulting with non-monoexponential behavior are present in breast cancer, taking into account tumor spatial heterogeneity. Additionally, methodological factors affecting the signal in low and high diffusion-sensitizing...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4927255

    authors: Panek R,Borri M,Orton M,O'Flynn E,Morgan V,Giles SL,deSouza N,Leach MO,Schmidt MA

    更新日期:2015-08-01 00:00:00

  • Dependence with air density of the response of the PTW SourceCheck ionization chamber for low energy brachytherapy sources.

    abstract:PURPOSE:Air-communicating well ionization chambers are commonly used to assess air kerma strength of sources used in brachytherapy. The signal produced is supposed to be proportional to the air density within the chamber and, therefore, a density-independent air kerma strength is obtained when the measurement is correc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4831757

    authors: Tornero-López AM,Guirado D,Perez-Calatayud J,Ruiz-Arrebola S,Simancas F,Gazdic-Santic M,Lallena AM

    更新日期:2013-12-01 00:00:00

  • Neutron energy spectra and dose-distribution spectra of cyclotron-produced neutron beams.

    abstract::Neutron energy spectra and spectra of dose deposition in tissue-equivalent material have been measured for neutron sources produced by 16-, 22-, 35-, and 45.5-MeV deuterons and 22.5-, 35-, 45-, and 65.5-MeV protons incident upon a thick beryllium target. Neutron spectra were measured using time-of-flight techniques an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594392

    authors: Heintz PH,Johnsen SW,Peek NF

    更新日期:1977-05-01 00:00:00

  • Postal intercomparison of absorbed dose for high energy x rays with thermoluminescence dosimeters.

    abstract::This study concerns the accuracy and precision of the IAEA/WHO LiF TLD system used in intercomparison by mail of absorbed doses from 60Co gamma-radiation and 4-25 MV x rays. The system employs 160 mg LiF powder in polystyrene capsules, which are placed at 5 or 7 cm depth in water and irradiated to doses close to 200 r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594746

    authors: Bjärngard BE,Kase KR,Rudén BI,Biggs PJ,Boyer AL,Johansson KA

    更新日期:1980-09-01 00:00:00

  • Determination of exit skin dose for 192Ir intracavitary accelerated partial breast irradiation with thermoluminescent dosimeters.

    abstract:PURPOSE:Intracavitary accelerated partial breast irradiation (APBI) has become a popular treatment for early stage breast cancer in recent years due to its shortened course of treatment and simplified treatment planning compared to traditional external beam breast conservation therapy. However, the exit dose to the ski...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3429089

    authors: Raffi JA,Davis SD,Hammer CG,Micka JA,Kunugi KA,Musgrove JE,Winston JW Jr,Ricci-Ott TJ,DeWerd LA

    更新日期:2010-06-01 00:00:00

  • A K alpha dual energy x-ray source for coronary angiography.

    abstract::The use of characteristic-line radiation from rare-earth targets bombarded by high-energy (up to 1 MeV) electron beams has been evaluated as an x-ray source for dual energy K-edge subtraction imaging of the human coronary arteries. Two characteristic-line x-ray sources, one using the split K alpha 1 and K alpha 2 line...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596648

    authors: Manning HL,Shefer RE,Klinkowstein RE,Mistretta CA

    更新日期:1991-09-01 00:00:00

  • Projection-based improvement of 3D reconstructions from motion-impaired dental cone beam CT data.

    abstract:PURPOSE:Computed tomography (CT) and, in particular, cone beam CT (CBCT) have been increasingly used as a diagnostic tool in recent years. Patient motion during acquisition is common in CBCT due to long scan times. This results in degraded image quality and may potentially increase the number of retakes. Our aim was to...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13731

    authors: Niebler S,Schömer E,Tjaden H,Schwanecke U,Schulze R

    更新日期:2019-10-01 00:00:00

  • SU-E-T-541: Dose Calculation Algorithm for External Neutron Radiotherapy Based on Pencil Beam Method.

    abstract:PURPOSE:To evaluate the availability and performance of pencil beam algorithm for fast neutrons radiotherapy dose calculations and to achieve improvements in universality, speed and inhomogeneities corrections. METHODS:Pencil beam (PB) method uses integration of dose kernel cross field size to estimate dose distributi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735630

    authors: Moiseev A,Klimanov V

    更新日期:2012-06-01 00:00:00

  • Model-based calculations of off-axis ratio of conic beams for a dedicated 6 MV radiosurgery unit.

    abstract:PURPOSE:Because the small-radius photon beams shaped by cones in stereotactic radiosurgery (SRS) lack lateral electronic equilibrium and a detector's finite cross section, direct experimental measurement of dosimetric data for these beams can be subject to large uncertainties. As the dose calculation accuracy of a trea...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3488900

    authors: Yang JN,Ding X,Du W,Pino R

    更新日期:2010-10-01 00:00:00

  • A study of effective attenuation coefficient for calculating tissue compensator thickness.

    abstract::Dose uniformity throughout the treatment volume is essential to precision radiation therapy. Tissue compensators are often used as a means to eliminate dose nonuniformity resulting from surface contour irregularities. This paper evaluates the accuracy of using an effective attenuation coefficient for calculating the t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596561

    authors: Bagne FR,Samsami N,Hoke SW,Bronn DG

    更新日期:1990-01-01 00:00:00

  • Anatomy-based three-dimensional dose optimization in brachytherapy using multiobjective genetic algorithms.

    abstract::In conventional dose optimization algorithms, in brachytherapy, multiple objectives are expressed in terms of an aggregating function which combines individual objective values into a single utility value, making the problem single objective, prior to optimization. A multiobjective genetic algorithm (MOGA) was develop...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598697

    authors: Lahanas M,Baltas D,Zamboglou N

    更新日期:1999-09-01 00:00:00

  • Ultrasonic tissue characterization via 2-D spectrum analysis: theory and in vitro measurements.

    abstract::A theoretical model is described for application in ultrasonic tissue characterization using a calibrated 2-D spectrum analysis method. This model relates 2-D spectra computed from ultrasonic backscatter signals to intrinsic physical properties of tissue microstructures, e.g., size, shape, and acoustic impedance. The ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2436978

    authors: Liu T,Lizzi FL,Ketterling JA,Silverman RH,Kutcher GJ

    更新日期:2007-03-01 00:00:00

  • A fast double template convolution isocenter evaluation algorithm with subpixel accuracy.

    abstract:PURPOSE:To design a fast Winston Lutz (fWL) algorithm for accurate analysis of radiation isocenter from images without edge detection or center of mass calculations. METHODS:An algorithm has been developed to implement the Winston Lutz test for mechanical/ radiation isocenter agreement using an electronic portal imagi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3524227

    authors: Winey B,Sharp G,Bussière M

    更新日期:2011-01-01 00:00:00

  • SU-F-BRCD-06: Multiple Anatomy Optimization of Accumulated Dose.

    abstract:PURPOSE:Multiple anatomy optimization (MAO) utilizing deformable dose accumulation on entire 4DCT data sets is implemented to overcome ambiguity between optimal dose defined on a single anatomy and optimal accumulated dose resulting from dose delivery to moving and deforming anatomy. METHODS:Six lung cancer patients a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735744

    authors: Watkins WT,Moore JA,Sharma M,Dial C,Xu H,Hugo GD,Gordon JJ,Siebers JV

    更新日期:2012-06-01 00:00:00

  • Detection nonuniformity measurements and corrections for cone beam transmission CT on a gamma camera.

    abstract::Cone beam transmission CT (CB-CT) improves SPECT imaging by providing high-quality attenuation maps for attenuation compensation and for correlated SPECT and CT imaging. The present work measures the detection nonuniformity for CB-CT implemented with a gamma camera, and applies nonuniformity corrections to make CB-CT ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596838

    authors: Manglos SH,Capone RB,Bassano DA

    更新日期:1992-03-01 00:00:00

  • Evaluating the impact of extended field-of-view CT reconstructions on CT values and dosimetric accuracy for radiation therapy.

    abstract:PURPOSE:Wide bore CT scanners use extended field-of-view (eFOV) reconstruction algorithms to attempt to recreate tissue truncated due to large patient habitus. Radiation therapy planning systems rely on accurate CT numbers in order to correctly plan and calculate radiation dose. This study looks at the impact of eFOV r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13299

    authors: Cheung JP,Shugard E,Mistry N,Pouliot J,Chen J

    更新日期:2019-02-01 00:00:00

  • An automatic seed finder for brachytherapy CT postplans based on the Hough transform.

    abstract:PURPOSE:The purpose of the work is to describe a new algorithm for the automatic detection of implanted radioactive seeds within the prostate. The algorithm is based on the traditional Hough transform. A method of quality assurance is described as well as a quantitative phantom study to determine the accuracy of the al...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.1778837

    authors: Holupka EJ,Meskell PM,Burdette EC,Kaplan ID

    更新日期:2004-09-01 00:00:00

  • Conceptual design of beryllium targets for the generation of neutron beams for radiation therapy by the (p,n) reaction.

    abstract::A conceptual design is presented showing that, by judiciously choosing the beryllium target thickness and the backstop material, improvements can be achieved in dose-rate, skin sparing, and penetration of neutron beams generated by the same proton accelerator. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594748

    authors: Awschalom M,Rosenberg I

    更新日期:1980-09-01 00:00:00

  • Positional radiotherapy beam dosimetry using a laser heated thermoluminescent plate.

    abstract::A 4-W, laser-based system for the positional readout of thermoluminescent (TL) plates was utilized to obtain dose profiles for a 60Co radiotherapy beam. Experimentally obtained glow curves for LiF resulting from the rapid heating rates characteristic of laser heating agreed well with results predicted using a first-or...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596580

    authors: Kearfott KJ,Grupen-Shemansky ME

    更新日期:1990-05-01 00:00:00

  • Use of a dynamic rangeshifter for modifying the depth-dose distributions of negative pions.

    abstract::In order to use negative pions for the treatment of large deep-seated tumors in radiotherapy, it is necessary to produce depth-dose distributions tailored to specific shapes. We present here a method of beam shaping which utilizes a fluid-filled piston having a programmable, computer-controlled, time-dependent thickne...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594313

    authors: Amols HI,Liska DJ,Halbig J

    更新日期:1977-09-01 00:00:00