Scattered photons produced by beam-modifying filters.

Abstract:

:When a beam-modifying filter such as a wedge or a compensator is placed in an x-ray beam, scattered photons are generated in the filter material. The magnitude of the dose contribution from these photons for a 4-MV x-ray beam was measured. At a distance of 30 cm from the filter, a copper sheet of 1-cm thickness produced a dose contribution on the centerline of about 6% of the transmitted primary dose in a 20 X 20 cm2 field. At the edges of the beam, this contribution was only about one-half that on the centerline. The presence of these scattered photons leads to only minor dose errors in clinical applications if simple procedures are followed to account for their contribution.

journal_name

Med Phys

journal_title

Medical physics

authors

Huang PH,Chin LM,Bjärngard BE

doi

10.1118/1.595923

subject

Has Abstract

pub_date

1986-01-01 00:00:00

pages

57-63

issue

1

eissn

0094-2405

issn

2473-4209

journal_volume

13

pub_type

杂志文章
  • Fast dose optimization for rotating shield brachytherapy.

    abstract:PURPOSE:To provide a fast computational method, based on the proximal graph solver (POGS) - A convex optimization solver using the alternating direction method of multipliers (ADMM), for calculating an optimal treatment plan in rotating shield brachytherapy (RSBT). RSBT treatment planning has more degrees of freedom th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12486

    authors: Cho M,Wu X,Dadkhah H,Yi J,Flynn RT,Kim Y,Xu W

    更新日期:2017-10-01 00:00:00

  • Eye tracking and gating system for proton therapy of orbital tumors.

    abstract:PURPOSE:A new motion-based gated proton therapy for the treatment of orbital tumors using real-time eye-tracking system was designed and evaluated. METHODS:We developed our system by image-pattern matching, using a normalized cross-correlation technique with LabVIEW 8.6 and Vision Assistant 8.6 (National Instruments, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4729708

    authors: Shin D,Yoo SH,Moon SH,Yoon M,Lee SB,Park SY

    更新日期:2012-07-01 00:00:00

  • SPECT imaging of high energy isotopes and isotopes with high energy contaminants with rotating slat collimators.

    abstract:PURPOSE:Quantitative SPECT imaging is limited by many factors, including penetration of high energy photons through the collimator. Even small peaks of high energy yield extensive contamination in the photopeak energy window. Rotating slat collimators typically offer a 40- to 50-fold increase in geometric detection eff...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3177312

    authors: Van Holen R,Staelens S,Vandenberghe S

    更新日期:2009-09-01 00:00:00

  • Validation of Monte Carlo calculated surface doses for megavoltage photon beams.

    abstract::Recent work has shown that there is significant uncertainty in measuring build-up doses in mega-voltage photon beams especially at high energies. In this present investigation we used a phantom-embedded extrapolation chamber (PEEC) made of Solid Water to validate Monte Carlo (MC)-calculated doses in the dose build-up ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1829401

    authors: Abdel-Rahman W,Seuntjens JP,Verhaegen F,Deblois F,Podgorsak EB

    更新日期:2005-01-01 00:00:00

  • Dosimetric characterization of radionuclides for systemic tumor therapy: influence of particle range, photon emission, and subcellular distribution.

    abstract::Various radionuclides have been proposed for systemic tumor therapy. However, in most dosimetric analysis of proposed radionuclides the charged particles are taken into consideration while the potential photons are ignored. The photons will cause undesirable irradiation of normal tissue, and increase the probability o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2229428

    authors: Uusijärvi H,Bernhardt P,Ericsson T,Forssell-Aronsson E

    更新日期:2006-09-01 00:00:00

  • A boundary element approach for image-guided near-infrared absorption and scatter estimation.

    abstract::Multimodality NIR spectroscopy systems offer the possibility of region-based vascular and molecular characterization of tissue in vivo. However, computationally efficient 3D image reconstruction algorithms specific to these image-guided systems currently do not exist. Image reconstruction is often based on finite-elem...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2795832

    authors: Srinivasan S,Pogue BW,Carpenter C,Yalavarthy PK,Paulsen K

    更新日期:2007-11-01 00:00:00

  • Fast technetium-99m liver SPECT for evaluation of the pretreatment procedure for radioembolization dosimetry.

    abstract:PURPOSE:The efficiency of radioembolization procedures could be greatly enhanced if results of the 99m Tc-MAA pretreatment procedure were immediately available in the interventional suite, enabling 1-day procedures as a result of direct estimation of the hepatic radiation dose and lung shunt fraction. This would, howev...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13253

    authors: van der Velden S,Dietze MMA,Viergever MA,de Jong HWAM

    更新日期:2019-01-01 00:00:00

  • WE-E-BRA-03: MR Functional Imaging to Guide Radiotherapy: Opportunities and Challenges in the Clinic.

    abstract::Human tumors are characterized by an abnormal vascular network that develops because of unregulated angiogenesis. This contributes to abnormalities of the tumor microenvironment like hypoxia, acidosis and high interstitial fluid pressure that influence treatment response and patient survival. There is an important cli...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736156

    authors: Milosevic M

    更新日期:2012-06-01 00:00:00

  • Calculations of two-dimensional electric field and potential distributions around electrodes in conducting media.

    abstract::Tumor cells can be killed by heating to 42.5 degrees C. It is convenient to localize heating by passing electric current at 500 kHz through tissue between a pair of electrodes. It is desirable to determine, for a given electrode-tissue configuration, what the resulting field and, therefore, current distribution will b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594235

    authors: Hutson RL

    更新日期:1976-07-01 00:00:00

  • An investigation of a new amorphous silicon electronic portal imaging device for transit dosimetry.

    abstract::The relationship between the pixel value and exit dose was investigated for a new commercially available amorphous silicon electronic portal imaging device. The pixel to dose mapping function was established to be linear for detector distances between 116.5 cm to 150 cm from the source, radiation field sizes from 5 x ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1508108

    authors: Grein EE,Lee R,Luchka K

    更新日期:2002-10-01 00:00:00

  • Quantitative CT of lung nodules: dependence of calibration on patient body size, anatomic region, and calibration nodule size for single- and dual-energy techniques.

    abstract::Calcium concentration may be a useful feature for distinguishing benign from malignant lung nodules in computer-aided diagnosis. The calcium concentration can be estimated from the measured CT number of the nodule and a CT number vs calcium concentration calibration line that is derived from CT scans of two or more ca...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3148536

    authors: Goodsitt MM,Chan HP,Way TW,Schipper MJ,Larson SC,Christodoulou EG

    更新日期:2009-07-01 00:00:00

  • Absolute depth-dose-rate measurements for an 192Ir HDR brachytherapy source in water using MOSFET detectors.

    abstract::Reported MOSFET measurements concern mostly external radiotherapy and in vivo dosimetry. In this paper, we apply the technique for absolute dosimetry in the context of HDR brachytherapy using an 192Ir source. Measured radial dose rate distributions in water for different planes perpendicular to the source axis are pre...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2198168

    authors: Zilio VO,Joneja OP,Popowski Y,Rosenfeld A,Chawla R

    更新日期:2006-06-01 00:00:00

  • Confirmation of a realistic reactor model for BNCT dosimetry at the TRIGA Mainz.

    abstract:PURPOSE:In order to build up a reliable dose monitoring system for boron neutron capture therapy (BNCT) applications at the TRIGA reactor in Mainz, a computer model for the entire reactor was established, simulating the radiation field by means of the Monte Carlo method. The impact of different source definition techni...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4897242

    authors: Ziegner M,Schmitz T,Khan R,Blaickner M,Palmans H,Sharpe P,Hampel G,Böck H

    更新日期:2014-11-01 00:00:00

  • The accuracy of SPECT brain activation images: propagation of registration errors.

    abstract::Functional single photon emission computed tomography (SPECT) images of brain activation are based on a comparison of base line and activation images. The correctness of the functional images depends, among other factors, on the accurate spatial registration (alignment) of the base line and activation image data. The ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597228

    authors: Sychra JJ,Pavel DG,Chen Y,Jani A

    更新日期:1994-12-01 00:00:00

  • Statistical analysis of dose-volume and dose-wall histograms for rectal toxicity following 3D-CRT in prostate cancer.

    abstract::The purpose of this paper is to determine the correlation between dose-volume histogram (DVH) and dose wall-histogram (DWH) in the evaluation of rectal complications for prostate cancer patients treated with three-dimensional conformal radiotherapy (3D-CRT). A retrospective analysis of DVHs and DWHs of a subset of 25 ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1951427

    authors: García-Vicente F,Zapatero A,Floriano A,Cruz-Conde A,Perez L,Marín A,Mínguez C,Torres JJ

    更新日期:2005-08-01 00:00:00

  • Dose and dose averaged LET comparison of ¹H, ⁴He, ⁶Li, ⁸Be, ¹⁰B, ¹²C, ¹⁴N, and ¹⁶O ion beams forming a spread-out Bragg peak.

    abstract:PURPOSE:Modern clinical accelerators are capable of producing ion beams from protons up to neon. This work compares the depth dose distribution and corresponding dose averaged linear energy transfer (LET) distribution, which is related to the biological effectiveness, for different ion beams (¹H, ⁴He, ⁶Li, ⁸Be, ¹⁰B, ¹²...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3662911

    authors: Kantemiris I,Karaiskos P,Papagiannis P,Angelopoulos A

    更新日期:2011-12-01 00:00:00

  • SU-D-218-05: Material Quantification in Spectral X-Ray Imaging: Optimization and Validation.

    abstract:PURPOSE:To develop and validate a multivariate statistical method to optimize scanning parameters for material quantification in spectral x-rayimaging. METHODS:An optimization metric was constructed by extensively sampling the thickness space for the expected number of counts for m (two or three) materials. This resul...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734708

    authors: Nik SJ,Thing RS,Watts R,Meyer J

    更新日期:2012-06-01 00:00:00

  • Reverse mapping of normal tissue complication probabilities onto dose volume histogram space: the problem of randomness of the dose volume histogram sampling.

    abstract::A very important issue in contemporary inverse treatment radiotherapy planning is the specification of proper dose-volume constraints limiting the treatment planning algorithm from delivering high doses to the normal tissue surrounding the tumor. Recently we have proposed a method called reverse mapping of normal tiss...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2198307

    authors: Markov K,Schinkel C,Stavreva N,Stavrev P,Weldon M,Fallone BG

    更新日期:2006-09-01 00:00:00

  • Scatter rejection by electronic collimation.

    abstract::An electronic scanning-slit technology is under development which involves replacing paired fore and aft slits for scatter rejection with only one fore slit. As the slit scans across the portion of the patient to be imaged, pulsed x-ray exposures produce images of the slit in successive positions, which are digitized ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595940

    authors: Plenkovich D,Sorenson JA,Kruger RA

    更新日期:1986-03-01 00:00:00

  • Dosimetric properties of the new 125I BrachySeed model LS-1 source.

    abstract::The BrachySeed model LS-1 is one of the latest in a series of new brachytherapy 125I seeds that have recently become available commercially for interstitial implants. The dosimetric properties of the seed were investigated analytically, experimentally, and by Monte Carlo simulation. Following the AAPM Task Group 43 fo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1445411

    authors: Chan GH,Prestwich WV

    更新日期:2002-02-01 00:00:00

  • Leakage and scatter radiation from a double scattering based proton beamline.

    abstract::Proton beams offer several advantages over conventional radiation techniques for treating cancer and other diseases. These advantages might be negated if the leakage and scatter radiation from the beamline and patient are too large. Although the leakage and scatter radiation for the double scattering proton beamlines ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2805086

    authors: Moyers MF,Benton ER,Ghebremedhin A,Coutrakon G

    更新日期:2008-01-01 00:00:00

  • 3T MRI evaluation of the accuracy of atlas-based subthalamic nucleus identification.

    abstract::Modulation of the activity of the subthalamic nucleus (STN) using deep brain stimulation (DBS) in patients with advanced Parkinson's disease is the most common procedure performed today by functional neurosurgeons. The STN contours cannot be entirely identified on common 1.5 T images; in particular, the ventromedial b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2936229

    authors: Stancanello J,Muacevic A,Sebastiano F,Modugno N,Cerveri P,Ferrigno G,Uggeri F,Romanelli P

    更新日期:2008-07-01 00:00:00

  • Design and experimental testing of air slab caps which convert commercial electron diodes into dual purpose, correction-free diodes for small field dosimetry.

    abstract:PURPOSE:Two diodes which do not require correction factors for small field relative output measurements are designed and validated using experimental methodology. This was achieved by adding an air layer above the active volume of the diode detectors, which canceled out the increase in response of the diodes in small f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4894728

    authors: Charles PH,Cranmer-Sargison G,Thwaites DI,Kairn T,Crowe SB,Pedrazzini G,Aland T,Kenny J,Langton CM,Trapp JV

    更新日期:2014-10-01 00:00:00

  • Application of high field magnetic resonance microimaging in polymer gel dosimetry.

    abstract:PURPOSE:The purpose of this work was to examine the suitability of VIPARnd polymer gel-9.4 T magnetic resonance microimaging system for high spatial resolution dose distribution measurements. METHODS:The VIPARnd samples (3 cm in outside diameter and 12 cm in height) were exposed to ionizing radiation by using a linear...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14186

    authors: Skorupa A,Woźnica A,Ciszek M,Staniszewski M,Kijonka M,Kozicki M,Woźniak B,Orlef A,Polański A,Boguszewicz Ł,Sokół M

    更新日期:2020-08-01 00:00:00

  • Dose distributions in bifurcated coronary vessels treated with catheter-based photon and beta emitters in intravascular brachytherapy.

    abstract::The dose distributions in the bifurcated vessels treated with intravascular brachytherapyline sources are complicated and depend on the bifurcation geometry consisting of a main and a branch vessel at different angles. To investigate the dosimetric effects at the bifurcation, calculations were performed on branching v...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1582813

    authors: Yue N,Roberts KB,Pfau SE,Nath R

    更新日期:2003-07-01 00:00:00

  • Anthropomorphic 1H MRS head phantom.

    abstract::An anthropomorphic 1H MRS head phantom has been developed which mimics the in vivo structure, metabolite concentrations, and relaxation times (for both water and metabolites) of human brain tissue. Different brain regions and two tumor types, fluid-containing ventricles, and air-filled sinus, and subcutaneous fat are ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598306

    authors: Rice JR,Milbrandt RH,Madsen EL,Frank GR,Boote EJ,Blechinger JC

    更新日期:1998-07-01 00:00:00

  • WE-E-213CD-03: Inverse-Consistent Symmetric Registration of Inner Colon Surfaces Derived from Prone and Supine CT Colonography.

    abstract:PURPOSE:Robust registration of prone and supine colonie surfaces acquired during CT colonography may lead to faster and more accurate detection of colorectal cancer and polyps. Any directional bias when registering one surface to the other could precipitate incorrect anatomical correspondence and engender reader error....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736159

    authors: Roth H,McClelland J,Modat M,Hampshire T,Boone D,Hu M,Ourselin S,Halligan S,Hawkes D

    更新日期:2012-06-01 00:00:00

  • Sinusoidal modulation analysis for optical system MTF measurements.

    abstract::The modulation transfer function (MTF) is a commonly used metric for defining the spatial resolution characteristics of imaging systems. While the MTF is defined in terms of how an imaging system demodulates the amplitude of a sinusoidal input, this approach has not been in general use to measure MTFs in the medical i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597840

    authors: Boone JM,Yu T,Seibert JA

    更新日期:1996-12-01 00:00:00

  • Sparse and optimal acquisition design for diffusion MRI and beyond.

    abstract:PURPOSE:Diffusion magnetic resonance imaging (MRI) in combination with functional MRI promises a whole new vista for scientists to investigate noninvasively the structural and functional connectivity of the human brain-the human connectome, which had heretofore been out of reach. As with other imaging modalities, diffu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3700166

    authors: Koay CG,Ozarslan E,Johnson KM,Meyerand ME

    更新日期:2012-05-01 00:00:00

  • Reduced order constrained optimization (ROCO): clinical application to lung IMRT.

    abstract:PURPOSE:The authors use reduced-order constrained optimization (ROCO) to create clinically acceptable IMRT plans quickly and automatically for advanced lung cancer patients. Their new ROCO implementation works with the treatment planning system and full dose calculation used at Memorial Sloan-Kettering Cancer Center (M...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3575416

    authors: Stabenau H,Rivera L,Yorke E,Yang J,Lu R,Radke RJ,Jackson A

    更新日期:2011-05-01 00:00:00