Abstract:
:The BrachySeed model LS-1 is one of the latest in a series of new brachytherapy 125I seeds that have recently become available commercially for interstitial implants. The dosimetric properties of the seed were investigated analytically, experimentally, and by Monte Carlo simulation. Following the AAPM Task Group 43 formalism, the radial dose function, dose rate constant, and anisotropy parameters were determined. Experimental measurements were made in solid water-equivalent phantoms using GafChromic MD-55-2 films, with correction for the low energy film response. Analyses were carried out from absolute measurements, as well as relative measurements against the Nycomed Amersham OncoSeed Model 6711, which also served to validate our experimental methodology. A small, but systematic difference in the absolute measurements was observed depending on the duration of the irradiation. Monte Carlo simulation was performed using the Integrated Tiger Series CYLTRAN code. We benchmarked the code by comparing the dose parameters of Model 6702 with published values. The radial dose function, g(r), of the Model LS-1 seed was computed at distances from 0.25 to 10 cm by analytical and Monte Carlo calculations with reasonably good agreement. The suggested dose rate constant, A, based on the Monte Carlo simulation is 0.90+/-0.03 cGy h(-1) U(-1). This value is smaller than, but overlaps the experimental determination of 0.98+/-0.06 cGy h(-1) U(-1). The anisotropy function, F(r, theta), and anisotropy factor, phi(an)(r), compared favorably with those of the Model 6711.
journal_name
Med Physjournal_title
Medical physicsauthors
Chan GH,Prestwich WVdoi
10.1118/1.1445411subject
Has Abstractpub_date
2002-02-01 00:00:00pages
190-200issue
2eissn
0094-2405issn
2473-4209journal_volume
29pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:State of the art to access radiofrequency (RF) heating near implants is computer modeling of the devices and solving Maxwell's equations for the specific setup. For a set of input parameters, a fixed result is obtained. This work presents a theoretical approach in the alternating current (ac) limit, which can p...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3637495
更新日期:2011-10-01 00:00:00
abstract:PURPOSE:In the past decade, phase-contrast imaging (PCI) has been applied to study different kinds of tissues and human body parts, with an increased improvement of the image quality with respect to simple absorption radiography. A technique closely related to PCI is phase-retrieval imaging (PRI). Indeed, PCI is an ima...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3447727
更新日期:2010-07-01 00:00:00
abstract:PURPOSE:Severe artifacts in kilovoltage-CT simulation images caused by large metallic implants can significantly degrade the conspicuity and apparent CT Hounsfield number of targets and anatomic structures, jeopardize the confidence of anatomical segmentation, and introduce inaccuracies into the radiation therapy treat...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4762814
更新日期:2012-12-01 00:00:00
abstract:PURPOSE:To develop an individually optimized contrast-enhanced (CE) 4D-computed tomography (CT) for radiotherapy simulation in pancreatic ductal adenocarcinomas (PDA). METHODS:Ten PDA patients were enrolled. Each underwent three CT scans: a 4D-CT immediately following a CE 3D-CT and an individually optimized CE 4D-CT ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4963213
更新日期:2016-10-01 00:00:00
abstract::The 1983 AAPM protocol for the determination of absorbed dose from high-energy photon and electron beams recommends using Pion (the reciprocal of collection efficiency), as determined by the two-voltage technique, to correct for recombination losses in ionization chambers. Methods and data for the determination of ion...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595574
更新日期:1984-11-01 00:00:00
abstract::Statistical image reconstruction (SIR) methods have shown potential to substantially improve the image quality of low-dose x-ray computed tomography (CT) as compared to the conventional filtered back-projection (FBP) method. According to the maximum a posteriori (MAP) estimation, the SIR methods are typically formulat...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1002/mp.13123
更新日期:2018-10-01 00:00:00
abstract:PURPOSE:Task Group 119 (TG-119) has been adopted for evaluating the adequacy of intensity-modulated radiation therapy (IMRT) commissioning and for establishing patient-specific IMRT quality assurance (QA) passing criteria in clinical practice. TG-119 establishes 95% confidence limits (CLs), which help clinics identify ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12759
更新日期:2018-03-01 00:00:00
abstract:PURPOSE:A prototype in-house program was developed to assist deriving image guidance shifts clinically using our 4DCT method for lung SBRT. METHODS:Our in-house prototype program was implemented in MATLAB. The 4D DICOM CT dataset of interest is imported by the program from AW and subsequently accepts input from the us...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735493
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Current respiratory motion monitoring devices used for motion synchronization in medical imaging and radiotherapy provide either 1D respiratory signal over a specific region or 3D information based on few external or internal markers. On the other hand, newer technology may offer the potential to monitor the en...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3589131
更新日期:2011-06-01 00:00:00
abstract::The purpose of this work is to investigate algorithms for the delivery of intensity-modulated fields using independent collimators (IC). Two heuristic algorithms are proposed to calculate jaw-setting sequences for arbitrary 2D intensity distributions. The first algorithm is based on searching the whole intensity matri...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598794
更新日期:1999-12-01 00:00:00
abstract:PURPOSE:To develop an automated technique for evaluating lung stereotactic body radiotherapy (SBRT) plan quality and predicting achievable lung dose constraints. METHODS:We examined the workflow scripting capabilities of a radiation oncology software package (MIM Software Inc) for automatically generating mean dose gr...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735279
更新日期:2012-06-01 00:00:00
abstract::The nuclear magnetic resonance phenomenon has given rise to both magnetic resonance imaging, which yields morphologic data, and magnetic resonance spectroscopy (MRS), which yields chemical data. In humans these data are derived principally from the resonances of the hydrogen nucleus in the low molecular weight compoun...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.2975225
更新日期:2008-10-01 00:00:00
abstract::The modulation transfer function (MTF) is a commonly used metric for defining the spatial resolution characteristics of imaging systems. While the MTF is defined in terms of how an imaging system demodulates the amplitude of a sinusoidal input, this approach has not been in general use to measure MTFs in the medical i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597840
更新日期:1996-12-01 00:00:00
abstract::Because of complex dose distributions and dose gradients that are created in three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiation therapy (IMRT), photon- and electron-energy spectra might change significantly with spatial locations and doses. This study examined variations in photon- and...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2710550
更新日期:2007-04-01 00:00:00
abstract:PURPOSE:Most clinically deployed strategies for respiratory motion management in lung radiotherapy (e.g., gating and tracking) use external markers that serve as surrogates for tumor motion. However, typical lung phantoms used to validate these strategies are based on a rigid exterior and a rigid or a deformable-interi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4918581
更新日期:2015-05-01 00:00:00
abstract::Electronic portal imaging devices (EPIDs) are mainly used for patient setup verification during treatment but other geometric properties like block shape and leaf positions are also determined. Electronic portal dosimetry allows dosimetric treatment verification. By combining geometric and dosimetric information, the ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1640972
更新日期:2004-02-01 00:00:00
abstract::We are evaluating the usefulness of stereomammography in improving breast cancer diagnosis. One area that we are investigating is whether the improved depth perception associated with stereomammography might be significantly enhanced with the use of a virtual 3D cursor. A study was performed to evaluate the accuracy o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.599008
更新日期:2000-06-01 00:00:00
abstract:PURPOSE:The presence of respiratory motion during radiation treatment leads to degradation of the expected dose distribution, both for target coverage and healthy tissue sparing, particularly for techniques like pencil beam scanning proton therapy which have dynamic delivery systems. While tools exist to estimate this ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13182
更新日期:2018-11-01 00:00:00
abstract::The aim of the present study is to examine the validity of using silicon semiconductor detectors in degraded electron beams with a broad energy spectrum and a wide angular distribution. A comparison is made with diamond detector measurements, which is the dosimeter considered to give the best results provided that dos...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1315317
更新日期:2000-11-01 00:00:00
abstract:PURPOSE:Distortions in magnetic resonance imaging (MRI) compromise spatial fidelity, potentially impacting delineation and dose calculation. We characterized 2D and 3D large field of view (FOV), sequence-independent distortion at various positions in a 1.0 T high-field open MR simulator (MR-SIM) to implement correction...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4930245
更新日期:2015-10-01 00:00:00
abstract:PURPOSE:Anatomical variations occur during head and neck (H&N) radiotherapy treatment. kV cone-beam computed tomography (CBCT) images can be used for daily dose monitoring to assess dose variations owing to anatomic changes. Deep learning methods (DLMs) have recently been proposed to generate pseudo-CT (pCT) from CBCT ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14387
更新日期:2020-10-01 00:00:00
abstract:PURPOSE:There is an increasing interest in calculating linear energy transfer (LET) distributions for proton therapy treatments in order to assess the influence of this quantity in biological terms. Microdosimetric Monte Carlo (MC) simulations are useful tools to calculate dose-averaged LET, as this has been broadly pr...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13643
更新日期:2019-09-01 00:00:00
abstract::With the recent clinical implementation of real-time MRI-guided x-ray beam therapy (MRXT), attention is turning to the concept of combining real-time MRI guidance with proton beam therapy; MRI-guided proton beam therapy (MRPT). MRI guidance for proton beam therapy is expected to offer a compelling improvement to the c...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12371
更新日期:2017-08-01 00:00:00
abstract:PURPOSE:To determine the accuracy and reproducibility of the automatic- setup procedure of a 3D water scanner (3D SCANNER, Sun Nuclear Corp). The procedure automatically aligns the scanner's coordinate system to the Linac coordinate system. A unique off-center detector holder extends the scan range to 630 mm, eliminati...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734668
更新日期:2012-06-01 00:00:00
abstract::With intensity-modulated radiotherapy (IMRT), a variety of user-defined dose distribution can be produced using inverse planning. The generalized equivalent uniform dose (gEUD) has been used in IMRT optimization as an alternative objective function to the conventional dose-volume-based criteria. The purpose of this st...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1897464
更新日期:2005-05-01 00:00:00
abstract::An experiment to determine the peak of the energy spectrum of the photon beam from a Toshiba LMR-15 medical linear accelerator is described. It is found that the flattening filters removed much of the bremsstrahlung spectrum below approximately 1 MeV, resulting in a photon spectrum which peaks around 1.2 MeV. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595582
更新日期:1984-11-01 00:00:00
abstract:PURPOSE:The purpose of this study was to detect and analyze anomalies between a large number of computed tomography (CT) scanners, tracked over time, utilized to collect human pulmonary CT data for a national multicenter study: chronic obstructive pulmonary disease genetic epidemiology study (COPDGene). METHODS:A cust...
journal_title:Medical physics
pub_type: 杂志文章,多中心研究
doi:10.1118/1.4747342
更新日期:2012-09-01 00:00:00
abstract::It is well established that the diffusion approximation (DA) is valid for light propagation in highly scattering media, but it breaks down in nonscattering void regions. The methods that handle the void with refractive index matched boundary were previously developed. For the void with refractive index mismatched boun...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1766418
更新日期:2004-08-01 00:00:00
abstract::Small photon fields are increasingly used in modern radiotherapy and especially in IMRT and SRS/SRT treatments. The uncertainties related to small field profile measurements can introduce significant systematic errors to the overall treatment process. These measurements are challenging mainly due to the absence of cha...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2977829
更新日期:2008-10-01 00:00:00
abstract:PURPOSE:The feasibility of intensity modulated brachytherapy (IMBT) to improve dose conformity for irregularly shaped targets has been previously investigated by researchers by means of using partially shielded sources. However, partial shielding does not fully explore the potential of IMBT. The goal of this study is t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3456598