Abstract:
PURPOSE:The feasibility of intensity modulated brachytherapy (IMBT) to improve dose conformity for irregularly shaped targets has been previously investigated by researchers by means of using partially shielded sources. However, partial shielding does not fully explore the potential of IMBT. The goal of this study is to introduce the concept of three dimensional (3D) intensity modulated brachytherapy and solve two fundamental issues regarding the application of 3D IMBT treatment planning: The dose calculation algorithm and the inverse treatment planning method. METHODS:A 3D IMBT treatment planning system prototype was developed using the MATLAB platform. This system consists of three major components: (1) A comprehensive IMBT source calibration method with dosimetric inputs from Monte Carlo (EGSnrc) simulations; (2) a "modified TG-43" (mTG-43) dose calculation formalism for IMBT dosimetry; and (3) a physical constraint based inverse IMBT treatment planning platform utilizing a simulated annealing optimization algorithm. The model S700 Axxent electronic brachytherapy source developed by Xoft, Inc. (Fremont, CA), was simulated in this application. Ten intracavitary accelerated partial breast irradiation (APBI) cases were studied. For each case, an "isotropic plan" with only optimized source dwell time and a fully optimized IMBT plan were generated and compared to the original plan in various dosimetric aspects, such as the plan quality, planning, and delivery time. The issue of the mechanical complexity of the IMBT applicator is not addressed in this study. RESULTS:IMBT approaches showed superior plan quality compared to the original plans and tht isotropic plans to different extents in all studied cases. An extremely difficult case with a small breast and a small distance to the ribs and skin, the IMBT plan minimized the high dose volume V200 by 16.1% and 4.8%, respectively, compared to the original and the isotropic plans. The conformity index for the target was increased by 0.13 and 0.04, respectively. The maximum dose to the skin was reduced by 56 and 28 cGy, respectively, per fraction. Also, the maximum dose to the ribs was reduced by 104 and 96 cGy, respectively, per fraction. The mean dose to the ipsilateral and contralateral breasts and lungs were also slightly reduced by the IMBT plan. The limitations of IMBT are the longer planning and delivery time. The IMBT plan took around 2 h to optimize, while the isotropic plan optimization could reach the global minimum within 5 min. The delivery time for the IMBT plan is typically four to six times longer than the corresponding isotropic plan. CONCLUSIONS:In this study, a dosimetry method for IMBT sources was proposed and an inverse treatment planning system prototype for IMBT was developed. The improvement of plan quality by 3D IMBT was demonstrated using ten APBI case studies. Faster computers and higher output of the source can further reduce plan optimization and delivery time, respectively.
journal_name
Med Physjournal_title
Medical physicsauthors
Shi C,Guo B,Cheng CY,Esquivel C,Eng T,Papanikolaou Ndoi
10.1118/1.3456598subject
Has Abstractpub_date
2010-07-01 00:00:00pages
3725-37issue
7eissn
0094-2405issn
2473-4209journal_volume
37pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::The minimum margins required to compensate for random geometric uncertainties in the delivery of radiotherapy treatment were determined for a spherical Clinical Target Volume, using an analytic model for the cumulative dose. Margins were calculated such that the minimum dose in the target would be no less than 95% of ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1809991
更新日期:2004-11-01 00:00:00
abstract:PURPOSE:When an intensity-modulated radiation beam is delivered to a moving target, the interplay effect between dynamic beam delivery and the target motion due to miss-synchronization can cause unpredictable dose delivery. The portal dose image in electronic portal imaging device (EPID) represents radiation attenuated...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4799941
更新日期:2013-05-01 00:00:00
abstract:PURPOSE:To find an upper bound on the maximum dose reduction possible for any reconstruction algorithm, analytic or iterative, that result from the inclusion of the data statistics. The authors do not analyze noise reduction possible from prior knowledge or assumptions about the object. METHODS:The authors examined th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4941954
更新日期:2016-03-01 00:00:00
abstract::Intensity modulated radiation therapy (IMRT) with a dynamic multileaf collimator (DMLC) requires synchronization of DMLC leaf motion with dose delivery. A delay in DMLC communication is known to cause leaf lag and lead to dosimetric errors. The errors may be exacerbated by gated operation. The purpose of this study wa...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1592017
更新日期:2003-08-01 00:00:00
abstract::A proton beam is extracted from the 200-MeV linear accelerator at the Fermi National Accelerator Laboratory to investigate the efficacy of proton radiography in medical diagnosis. Fluence rates from 2 X 10(3) to 2 X 10(5) protons/cm2s over a 28-cm diameter field are obtained with a full width at half-maximum beam-ener...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594426
更新日期:1978-05-01 00:00:00
abstract:PURPOSE:To quantitatively characterize the interfractional anatomic variations in post-operative radiation therapy (RT) for prostate bed, so that appropriate strategy that can fully address these variations can be developed. METHODS:A total of 102 daily pre-treatment CT acquired using an in-room CT (CTVision, Siemens)...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734844
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Magnetic particle imaging (MPI) is a relatively new method to image the spatial distribution of magnetic nanoparticle (MNP) tracers administered to the body with high spatial and temporal resolution using an inhomogeneous magnetic field. The spatial information of the MNP's is encoded using a field free point (...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13411
更新日期:2019-04-01 00:00:00
abstract:PURPOSE:Radiosurgery uses small fields and high-radiation doses to treat intra- and extracranial lesions in a single session. The lack of a lateral electronic equilibrium and the presence of high-dose gradients in these fields are challenges for adequate measurements. The availability of radiation detectors with the hi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4752211
更新日期:2012-10-01 00:00:00
abstract::Vessel size measurement is perhaps the most often performed quantitative analysis in diagnostic and interventional angiography. Although automated vessel sizing techniques are generally considered to have good accuracy and precision, we have observed that clinicians rarely use these techniques in standard clinical pra...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1562491
更新日期:2003-04-01 00:00:00
abstract::The synchronization of dynamic multileaf collimator (DMLC) response with respiratory motion is critical to ensure the accuracy of DMLC-based four dimensional (4D) radiation delivery. In practice, however, a finite time delay (response time) between the acquisition of tumor position and multileaf collimator response ne...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1915017
更新日期:2005-06-01 00:00:00
abstract::Clinical and biological evidence suggest that the success of GRID therapy in debulking large tumors depends on the high peak-to-valley contrast in the dose distribution. In this study, we show that the peaks and valleys can be significantly blurred out by respiration-induced tumor motion, possibly affecting the clinic...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2977538
更新日期:2008-10-01 00:00:00
abstract::In x-ray spectral measurement using a semiconductor detector system, accurate positioning of the detector in front of the anode is very important. This needs accurate determination of the focal spot position on the target in an x-ray tube. We present a simple technique to determine the focal spot position accurately. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597122
更新日期:1993-07-01 00:00:00
abstract::Complementary metal-oxide-semiconductors (CMOS) active pixel sensors can be optically coupled to CsI:Tl phosphors forming a indirect active pixel flat panel imager (APFPI) for high performance medical imaging. The aim of this work is to determine the x-ray imaging capabilities of CMOS-based APFPI and study the signal ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3036117
更新日期:2009-01-01 00:00:00
abstract:PURPOSE:The authors investigate the extent to which Response Evaluation Criteria in Solid Tumors (RECIST) can predict tumor volumes in ideal geometric settings and using clinical data. METHODS:The authors consider a hierarchy of models including uniaxial ellipsoids, general ellipsoids, and composites of ellipsoids, us...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3577602
更新日期:2011-05-01 00:00:00
abstract:PURPOSE:To develop and evaluate the impact on lesion conspicuity of a software-based x-ray scatter correction algorithm for digital breast tomosynthesis (DBT) imaging into which a precomputed library of x-ray scatter maps is incorporated. METHODS:A previously developed model of compressed breast shapes undergoing mamm...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4866229
更新日期:2014-03-01 00:00:00
abstract:PURPOSE:In radiotherapy, it is important to predict the response of tumors to irradiation prior to the treatment. This is especially important for hypoxic tumors, which are known to be highly radioresistant. Mathematical modeling based on the dose distribution, biological parameters, and medical images may help to impr...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4903298
更新日期:2015-01-01 00:00:00
abstract:PURPOSE:The purpose of this study is to evaluate the feasibility of kilovoltage cone-beam CT (CBCT) images that are obtained with the Varian On-Board Imager in dose calculation at each radiation therapy. METHODS:CBCT images are commonly degraded by scattered radiations originating in the patient's body, and so the CT ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734936
更新日期:2012-06-01 00:00:00
abstract::The availability of digital radiographic imaging on simulators has led to the investigation of a number of new imaging possibilities, including digital linear tomography (tomosynthesis). It has been shown that a single set of projections in this case is sufficient to reconstruct images from multiple planes, including ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598006
更新日期:1997-06-01 00:00:00
abstract::Using high-energy photon and electron beams, the response of two solid water parallel-plate chambers is evaluated against a PTW (Physicallsch-Technische Werkstatten) Farmer-type chamber. These two chambers are (1) a Memorial "Holt" chamber which was further modified by this author to take advantage of electrically con...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597074
更新日期:1993-03-01 00:00:00
abstract:PURPOSE:To develop a novel aperture-based algorithm for volumetric modulated are therapy (VMAT) treatment plan optimization with high quality and high efficiency. METHODS:The VMAT optimization problem is formulated as a large-scale convex programming problem solved by a column generation approach. The authors consider...
journal_title:Medical physics
pub_type: 信件
doi:10.1118/1.3491675
更新日期:2010-11-01 00:00:00
abstract:PURPOSE:Temporal subtraction is used to detect the interval change in chest radiographs and aid radiologists in patient diagnosis. This method registers two temporally different images by geometrically warping the lung region, or "lung mask," of a previous radiographic image to align with the current image. The gray le...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3259712
更新日期:2009-12-01 00:00:00
abstract:PURPOSE:To develop a pencil beam dose calculation algorithm for scanned proton beams that improves modeling of scatter events. METHODS:Our pencil beam algorithm (PBA) was developed for calculating dose from monoenergetic, parallel proton beams in homogeneous media. Fermi-Eyges theory was implemented for pencil beam tr...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735624
更新日期:2012-06-01 00:00:00
abstract::MR acoustic radiation force (ARF) imaging was developed for measuring tiSsue elastic properties using focused ultrasound to deliver a localized tissue motion. In this study, an imaging ultrasound transducer was mounted on the focused ultrasound transducer and ultrasound motion tracking was performed simultaneously to ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3120289
更新日期:2009-06-01 00:00:00
abstract:PURPOSE:To develop and test the feasibility of a two-pass iterative reconstruction algorithm with material decomposition designed to obtain quantitative iodine measurements in digital breast tomosynthesis. METHODS:Contrast-enhanced mammography has shown promise as a cost-effective alternative to magnetic resonance ima...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14400
更新日期:2020-10-01 00:00:00
abstract:PURPOSE:An original radionuclide calibrator method for activity determination is presented. The method could be used for intercomparison surveys for short half-life radioactive sources used in Nuclear Medicine, such as(99m)Tc or most positron emission tomography radiopharmaceuticals. METHODS:By evaluation of the resul...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4884035
更新日期:2014-07-01 00:00:00
abstract:PURPOSE:We propose a new method for efficient particle transportation in voxelized geometry for Monte Carlo simulations. We describe its use for calculating dose distribution in CT images for radiation therapy. MATERIAL AND METHODS:The proposed approach, based on an implicit volume representation named segmented volum...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2884854
更新日期:2008-04-01 00:00:00
abstract:PURPOSE:A prototype in-house program was developed to assist deriving image guidance shifts clinically using our 4DCT method for lung SBRT. METHODS:Our in-house prototype program was implemented in MATLAB. The 4D DICOM CT dataset of interest is imported by the program from AW and subsequently accepts input from the us...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735493
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The aim of this study was to develop a dose calculation method which is applicable to the interseed attenuation and the geometry lacking the equilibrium radiation scatter conditions in brachytherapy. METHODS:The dose obtained from measurement with a radiophotoluminescent glass rod dosimeter (GRD) was compared ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3590370
更新日期:2011-06-01 00:00:00
abstract::In many of brachytherapy procedures, a large amount of radioactive sources are used to deliver desired doses to the target volume. It is both the federal regulation recommendation (U.S. Nuclear Regulatory Commission, 10 CFR 35.432) and recommendations of the American Association of Physicists in Medicine (AAPM) [Kutch...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2734723
更新日期:2007-06-01 00:00:00
abstract::Interstitial brachytherapy for carcinoma of the prostate is achieved through the use of a configuration of radioactive seeds placed in a manner that delivers a customized, reasonably uniform dose to the target volume. Accurate dose delivery depends on both precise seed placement and reliable seed strength in the impla...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598877
更新日期:2000-01-01 00:00:00