MR acoustic radiation force imaging: in vivo comparison to ultrasound motion tracking.

Abstract:

:MR acoustic radiation force (ARF) imaging was developed for measuring tiSsue elastic properties using focused ultrasound to deliver a localized tissue motion. In this study, an imaging ultrasound transducer was mounted on the focused ultrasound transducer and ultrasound motion tracking was performed simultaneously to MR ARF imaging to validate the measurement results. In vivo studies on rabbit thigh muscle were performed and results showed a general agreement between the two modalities (slope=0.96 and R2=0.67). The temporal information by the ultrasound measurement indicates that the parameters in MR ARF imaging should be optimized according to the tissue type, acoustic power, and envelope and frequency of the ARF modulation.

journal_name

Med Phys

journal_title

Medical physics

authors

Huang Y,Curiel L,Kukic A,Plewes DB,Chopra R,Hynynen K

doi

10.1118/1.3120289

subject

Has Abstract

pub_date

2009-06-01 00:00:00

pages

2016-20

issue

6

eissn

0094-2405

issn

2473-4209

journal_volume

36

pub_type

杂志文章
  • Low-dose dynamic myocardial perfusion CT imaging using a motion adaptive sparsity prior.

    abstract:PURPOSE:Dynamic myocardial perfusion computed tomography (DM-PCT) imaging offers benefits over quantitative assessment of myocardial blood flow (MBF) for diagnosis and risk stratification of coronary artery disease. However, one major drawback of DM-PCT imaging is that a high radiation level is imparted by repeated sca...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12285

    authors: Bian Z,Zeng D,Zhang Z,Gong C,Tian X,Yan G,Huang J,Guo H,Chen B,Zhang J,Feng Q,Chen W,Ma J

    更新日期:2017-09-01 00:00:00

  • Radiation dose to the lungs from ventilation studies with 133Xe.

    abstract::The radiation dose to the lungs from 133Xe in lung air is directly proportional to the time integral of 133Xe concentration; i.e., the cumulated concentration in the lungs. Using kinetic models developed to fit clinical observations, we have studied the effect of retention on cumulated concentration in lung air. The m...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594341

    authors: Watson EE,Cloutier RJ

    更新日期:1977-11-01 00:00:00

  • Practical cone-beam lambda tomography.

    abstract::As a potentially important technology for medical x-ray computed tomography (CT), lambda tomography (LT) is to reconstruct a gradient-like image only from local projection data. Based on our recently derived exact fan-beam LT formula, [H. Y. Gu and G. Wang, Int. J. Biomed. Imaging 2006(1), 1-9 (2006)] here we propose ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2348767

    authors: Yu H,Ye Y,Wang G

    更新日期:2006-10-01 00:00:00

  • Rejection and redistribution of scattered radiation in scan equalization digital radiography (SEDR): simulation with spot images.

    abstract::The anti-scatter grid has been widely used to reject scatter and increase the perceptibility of a low-contrast object in chest radiography; however, it also attenuated the primary x-rays, resulting in a substantial loss of information and an increased relative noise level in heavily attenuated regions. A more dose eff...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2739805

    authors: Liu X,Shaw CC

    更新日期:2007-07-01 00:00:00

  • On the uncertainties in effective dose estimates of adult CT head scans.

    abstract::Estimates of the effective dose to adult patients from computed tomography (CT) head scanning can be calculated using a number of different methods. These estimates can be used for a variety of purposes, such as improving scanning protocols, comparing different CT imaging centers, and weighing the benefits of the scan...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2952359

    authors: Gregory KJ,Bibbo G,Pattison JE

    更新日期:2008-08-01 00:00:00

  • Quantitative CT of lung nodules: dependence of calibration on patient body size, anatomic region, and calibration nodule size for single- and dual-energy techniques.

    abstract::Calcium concentration may be a useful feature for distinguishing benign from malignant lung nodules in computer-aided diagnosis. The calcium concentration can be estimated from the measured CT number of the nodule and a CT number vs calcium concentration calibration line that is derived from CT scans of two or more ca...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3148536

    authors: Goodsitt MM,Chan HP,Way TW,Schipper MJ,Larson SC,Christodoulou EG

    更新日期:2009-07-01 00:00:00

  • Optimization of detector pixel size for stent visualization in x-ray fluoroscopy.

    abstract::Pixel size is of great interest in the flat-panel detector design because of its potential impact on image quality. In the particular case of angiographic x-ray fluoroscopy, small pixels are required in order to adequately visualize interventional devices such as guidewires and stents which have wire diameters as smal...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2169907

    authors: Jiang Y,Wilson DL

    更新日期:2006-03-01 00:00:00

  • Optical image processing with liquid-crystal display for image intensifier/television systems.

    abstract::We have studied the effect of real-time optical image processing (OIP) in an image intensifier/television (II-TV) radiographic imaging system by using a liquid-crystal display (LCD) placed between the II and the TV camera. The LCD compresses the dynamic range of the transmitted image by modulating the spatial distribu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596199

    authors: Lam KL,Chan HP,Doi K

    更新日期:1988-11-01 00:00:00

  • A quality management program in intravascular brachytherapy.

    abstract::While simple, intravascular brachytherapy (IVB) presents a considerable potential for harm to the patient. The medical physicist maintains the responsibility to minimize the likelihood of operational problems or dosimetric errors. The principals for safe operation remain the same as with any radiotherapy treatment: to...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1524167

    authors: Chakri A,Thomadsen B

    更新日期:2002-12-01 00:00:00

  • Influence of gold nanoparticles embedded in water on nanodosimetry for keV photon irradiation.

    abstract:PURPOSE:For the past two decades, high-Z nanoparticles have been of high interest to improve the therapeutic outcomes of radiation therapy, especially for low-energy X-rays. Monte Carlo (MC) simulations have been used to evaluate the boost of dose deposition induced by Auger electrons near the nanoparticle surface, by ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14576

    authors: Poignant F,Monini C,Testa É,Beuve M

    更新日期:2020-11-04 00:00:00

  • AAPM Task Group 329: Reference dose specification for dose calculations: Dose-to-water or dose-to-muscle?

    abstract::Linac calibration is done in water, but patients are comprised primarily of soft tissue. Conceptually, and specified in NRG/RTOG trials, dose should be reported as dose-to-muscle to describe the dose to the patient. Historically, the dose-to-water of the linac calibration was often converted to dose-to-muscle for pati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13995

    authors: Kry SF,Feygelman V,Balter P,Knöös T,Charlie Ma CM,Snyder M,Tonner B,Vassiliev ON

    更新日期:2020-03-01 00:00:00

  • Film dosimetry analyses on the effect of gold shielding for iodine-125 eye plaque therapy for choroidal melanoma.

    abstract::One of the methods currently being used to treat choroidal melanoma employs an episcleral plaque containing I-125 radioactive seeds. However, comprehensive dosimetry studies on the plaque are scarce and controversial. For this work, we use film to study the dosimetry outside the lip of the gold shield of the eye plaqu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596556

    authors: Wu A,Krasin F

    更新日期:1990-09-01 00:00:00

  • On using an adaptive neural network to predict lung tumor motion during respiration for radiotherapy applications.

    abstract::In this study we address the problem of predicting the position of a moving lung tumor during respiration on the basis of external breathing signals--a technique used for beam gating, tracking, and other dynamic motion management techniques in radiation therapy. We demonstrate the use of neural network filters to corr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2134958

    authors: Isaksson M,Jalden J,Murphy MJ

    更新日期:2005-12-01 00:00:00

  • Spacing nomograph for interstitial implants of 125I seeds.

    abstract::Permanent implants of 125I seeds at Memorial Sloan-Kettering Cancer Center are performed by the method of "dimension averaging" to determine the total activity to be implanted; that is, the activity (in mCi) is taken to be five times the average dimension (in cm) of the target region. A nomograph has recently been dev...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594269

    authors: Anderson LL

    更新日期:1976-01-01 00:00:00

  • A novel off-axis scanning method for an enlarged ellipse cone-beam computed tomography field of view.

    abstract:PURPOSE:Current on-board imaging systems commonly used by modern linear accelerators (LINACs) have a limited field of view (FOV) for a cone-beam CT (CBCT) scan, which is typically less than 50 cm. Consequently, truncation artifacts often occur for large patients. The goal of this work is to investigate a novel method t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3514130

    authors: Li T,Li X,Yang Y,Heron DE,Huq MS

    更新日期:2010-12-01 00:00:00

  • A simple model for transit dosimetry based on a water equivalent EPID.

    abstract:PURPOSE:The aim of this study was to demonstrate a new model for implementing a transit dosimetry system as a means of in vivo dose verification with a water equivalent electronic portal imaging device (WE-EPID) and a conventional treatment planning system (TPS). METHOD AND MATERIALS:A standard amorphous silicon (a-Si...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12742

    authors: Deshpande S,Blake SJ,Xing A,Metcalfe PE,Holloway LC,Vial P

    更新日期:2018-03-01 00:00:00

  • On calculating kerma, collision kerma and radiative yields.

    abstract:PURPOSE:To study the relationships between dose (D), kerma (K), and collision kerma ( K col ) in photon beams and to investigate total radiative yields for electrons and positrons as a functio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13744

    authors: Rogers DWO,Townson RW

    更新日期:2019-11-01 00:00:00

  • Dosimetric effect of respiration-gated beam on IMRT delivery.

    abstract::Intensity modulated radiation therapy (IMRT) with a dynamic multileaf collimator (DMLC) requires synchronization of DMLC leaf motion with dose delivery. A delay in DMLC communication is known to cause leaf lag and lead to dosimetric errors. The errors may be exacerbated by gated operation. The purpose of this study wa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1592017

    authors: Duan J,Shen S,Fiveash JB,Brezovich IA,Popple RA,Pareek PN

    更新日期:2003-08-01 00:00:00

  • Micro-angiography for neuro-vascular imaging. II. Cascade model analysis.

    abstract::A micro-angiographic detector was designed and its performance was previously tested to evaluate its feasibility as an improvement over current x-ray detectors for neuro-interventional imaging. The detector was shown to have a modulation transfer function value of about 2% at the Nyquist frequency of 10 cycles/mm and ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1617550

    authors: Ganguly A,Rudin S,Bednarek DR,Hoffmann KR

    更新日期:2003-11-01 00:00:00

  • The effects of divergence and nonuniformity on the x-ray pencil-beam dose kernel.

    abstract::The scattered-photon part of pencil-beam dose kernels for high-energy x-ray beams can be derived experimentally by differentiating the broad-beam scatter-to-primary dose ratio as a function of radius. Formally, this requires a uniform and parallel beam, and the procedure is complicated by the nonideal, actual beam con...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597884

    authors: Ceberg CP,Bjärngard BE

    更新日期:1996-09-01 00:00:00

  • Transient noise characterization and filtration in CCD cameras exposed to stray radiation from a medical linear accelerator.

    abstract::Charge coupled devices (CCDs) are being increasingly used in radiation therapy for dosimetric purposes. However, CCDs are sensitive to stray radiation. This effect induces transient noise. Radiation-induced noise strongly alters the image and therefore limits its quantitative analysis. The purpose of this work is to c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2975147

    authors: Archambault L,Briere TM,Beddar S

    更新日期:2008-10-01 00:00:00

  • Cone-beam CT dose and imaging performance evaluation with a modular, multipurpose phantom.

    abstract:PURPOSE:A modular phantom for dosimetry and imaging performance evaluation in cone-beam computed tomography (CBCT) is reported, providing a tool for quantitative technical assessment that can be adapted to a broad variety of CBCT imaging configurations and clinical applications. METHODS:The phantom presents a set of m...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13952

    authors: Siewerdsen JH,Uneri A,Hernandez AM,Burkett GW,Boone JM

    更新日期:2020-02-01 00:00:00

  • A methodology to determine margins by EPID measurements of patient setup variation and motion as applied to immobilization devices.

    abstract::Assessment of clinic and site specific margins are essential for the effective use of three-dimensional and intensity modulated radiation therapy. An electronic portal imaging device (EPID) based methodology is introduced which allows individual and population based CTV-to-PTV margins to be determined and compared wit...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.1800712

    authors: Prisciandaro JI,Frechette CM,Herman MG,Brown PD,Garces YI,Foote RL

    更新日期:2004-11-01 00:00:00

  • Library based x-ray scatter correction for dedicated cone beam breast CT.

    abstract:PURPOSE:The image quality of dedicated cone beam breast CT (CBBCT) is limited by substantial scatter contamination, resulting in cupping artifacts and contrast-loss in reconstructed images. Such effects obscure the visibility of soft-tissue lesions and calcifications, which hinders breast cancer detection and diagnosis...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4955121

    authors: Shi L,Vedantham S,Karellas A,Zhu L

    更新日期:2016-08-01 00:00:00

  • Temporal and spectral imaging with micro-CT.

    abstract:PURPOSE:Micro-CT is widely used for small animal imaging in preclinical studies of cardiopulmonary disease, but further development is needed to improve spatial resolution, temporal resolution, and material contrast. We present a technique for visualizing the changing distribution of iodine in the cardiac cycle with du...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736809

    authors: Johnston SM,Johnson GA,Badea CT

    更新日期:2012-08-01 00:00:00

  • Results from a multicenter prostate IMRT dosimetry intercomparison for an OCOG-TROG clinical trial.

    abstract:PURPOSE:A multi-institution dosimetry intercomparison has been undertaken of prostate intensity modulated radiation therapy (IMRT) delivery. The dosimetry intercomparison was incorporated into the quality assurance for site credentialing for the Trans-Tasman Radiation Oncology Group Prostate Fractionated Irradiation Tr...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1118/1.4808151

    authors: Healy B,Frantzis J,Murry R,Martin J,Plank A,Middleton M,Catton C,Kron T

    更新日期:2013-07-01 00:00:00

  • Analysis of fractionation correction methodologies for multiple phase treatment plans in radiation therapy.

    abstract:PURPOSE:Radiation therapy is often delivered by multiple sequential treatment plans. For an accurate radiobiological evaluation of the overall treatment, fractionation corrections to each dose distribution must be applied before summing the three-dimensional dose matrix of each plan since the simpler approach of perfor...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4792636

    authors: Mavroidis P,Ferreira BC,Papanikolaou N,Lopes Mdo C

    更新日期:2013-03-01 00:00:00

  • Clinical reference dosimetry: comparison between AAPM TG-21 and TG-51 protocols.

    abstract::We compare the results of absorbed dose determined at reference conditions according to the AAPM TG-21 dose calibration protocol and the new AAPM TG-51 protocol. The AAPM TG-21 protocol for absorbed dose calibration is based on ionization chambers having exposure calibration factors for 60Co gamma rays, N(x). The new ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598999

    authors: Ding GX,Cygler JE,Kwok CB

    更新日期:2000-06-01 00:00:00

  • Reproducibility of the lung anatomy under active breathing coordinator control: Dosimetric consequences for scanned proton treatments.

    abstract:PURPOSE:The treatment of moving targets with scanned proton beams is challenging. For motion mitigation, an Active Breathing Coordinator (ABC) can be used to assist breath-holding. The delivery of pencil beam scanning fields often exceeds feasible breath-hold durations, requiring high breath-hold reproducibility. We ev...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13195

    authors: den Otter LA,Kaza E,Kierkels RGJ,Meijers A,Ubbels FJF,Leach MO,Collins DJ,Langendijk JA,Knopf AC

    更新日期:2018-12-01 00:00:00

  • Nitroxide conjugate of a thermally responsive elastin-like polypeptide for noninvasive thermometry.

    abstract::Hyperthermia, as an adjuvant with radiation and chemotherapy, has shown promise in the treatment of cancer. The relevant biological effects of a hyperthermia treatment are both time and temperature-dependent, creating a need for accurate thermometry. We present a novel noninvasive thermometry modality that combines a ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1782677

    authors: Dreher MR,Elas M,Ichikawa K,Barth ED,Chilkoti A,Rosen GM,Halpern HJ,Dewhirst M

    更新日期:2004-10-01 00:00:00