Abstract:
PURPOSE:A multi-institution dosimetry intercomparison has been undertaken of prostate intensity modulated radiation therapy (IMRT) delivery. The dosimetry intercomparison was incorporated into the quality assurance for site credentialing for the Trans-Tasman Radiation Oncology Group Prostate Fractionated Irradiation Trial 08.01 clinical trial. METHODS:An anthropomorphic pelvic phantom with realistic anatomy was used along with multiplanar dosimetry tools for the assessment. Nineteen centers across Australia and New Zealand participated in the study. RESULTS:In comparing planned versus measured dose to the target at the isocenter within the phantom, all centers were able to achieve a total delivered dose within 3% of planned dose. In multiplanar analysis with radiochromic film using the gamma analysis method to compare delivered and planned dose, pass rates for a 5%/3 mm criterion were better than 90% for a coronal slice through the isocenter. Pass rates for an off-axis coronal slice were also better than 90% except for one instance with 84% pass rate. CONCLUSIONS:Strengths of the dosimetry assessment procedure included the true anthropomorphic nature of the phantom used, the involvement of an expert from the reference center in carrying out the assessment at every site, and the ability of the assessment to detect and resolve dosimetry discrepancies.
journal_name
Med Physjournal_title
Medical physicsauthors
Healy B,Frantzis J,Murry R,Martin J,Plank A,Middleton M,Catton C,Kron Tdoi
10.1118/1.4808151subject
Has Abstractpub_date
2013-07-01 00:00:00pages
071706issue
7eissn
0094-2405issn
2473-4209journal_volume
40pub_type
临床试验,杂志文章,多中心研究相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:Brachytherapy with 106 Ru/106 Rh plaques offers good outcomes for small-to-medium choroidal melanomas and retinoblastomas. The dose measurement of the plaques is challenging, due to the small range of the emitted beta particles and steep dose gradients involved. The scarce publications on film dosimetry of 106 ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12777
更新日期:2018-04-01 00:00:00
abstract::In this work, we present a calcification-detection scheme that automatically localizes calcifications in a previously detected cluster in order to generate the input for a cluster-classification scheme developed in the past. The calcification-detection scheme makes use of three pieces of a priori information: the loca...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1559884
更新日期:2003-05-01 00:00:00
abstract::Testing computer-controlled linear accelerators for patient safety and proper patient dose delivery requires that certain beam characteristics be monitored over an extended period of time. Computer-controlled conformal radiation therapy using asymmetric collimator jaw settings necessitates stable symmetric treatment b...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596363
更新日期:1989-07-01 00:00:00
abstract::A commercial optical system developed by Solid Photography, Inc., has been used to generate precise paraffin--polyethylene tissue compensators. A program with the objective of constructing a medical facility has been undertaken to access patient topology for treatment planning, tissue-compensator fabrication, and pati...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594447
更新日期:1978-11-01 00:00:00
abstract::Registration of single slices from FluoroCT, CineMR, or interventional magnetic resonance imaging to three dimensional (3D) volumes is a special aspect of the two-dimensional (2D)/3D registration problem. Rather than digitally rendered radiographs (DRR), single 2D slice images obtained during interventional procedures...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2401661
更新日期:2007-01-01 00:00:00
abstract::We are developing an automated stereo spot mammography technique for improved imaging of suspicious dense regions within digital mammograms. The technique entails the acquisition of a full-field digital mammogram, automated detection of a suspicious dense region within that mammogram by a computer aided detection (CAD...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1737492
更新日期:2004-06-01 00:00:00
abstract:PURPOSE:The focus of this work was the demonstration and validation of VirtuaLinac with clinical photon beams and to investigate the implementation of low-Z targets in a TrueBeam linear accelerator (Linac) using Monte Carlo modeling. METHODS:VirtuaLinac, a cloud based web application utilizing Geant4 Monte Carlo code,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4861818
更新日期:2014-02-01 00:00:00
abstract:PURPOSE:To evaluate the accuracy of skin dose determination for composite multibeam 3D conformal radiation therapy (3DCRT) and intensity modulated radiation therapy (IMRT) treatments using optically stimulated luminescent dosimeters (OSLDs) and Eclipse treatment planning system. METHODS:Surface doses measured by OSLDs...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4890795
更新日期:2014-08-01 00:00:00
abstract::Preclinical experiments are carried out with approximately 20-30 microm wide, approximately 10 mm high parallel microbeams of hard, broad-"white"-spectrum x rays (approximately 50-600 keV) to investigate microbeam radiation therapy (MRT) of brain tumors in infants for whom other kinds of radiotherapy are inadequate an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1562169
更新日期:2003-04-01 00:00:00
abstract:PURPOSE:Tissue textures have been recognized as biomarkers for various clinical tasks. In computed tomography (CT) image reconstruction, it is important but challenging to preserve the texture when lowering x-ray exposure from full- toward low-/ultra-low dose level. Therefore, this paper aims to explore the texture-dos...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14449
更新日期:2020-10-01 00:00:00
abstract:PURPOSE:This article introduces the use of low power continuous wave frequency modulated radar for medical applications, specifically for remote monitoring of vital signs in patients. METHODS:Gigahertz frequency radar measures the electromagnetic wave signal reflected from the surface of a human body and from tissue b...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3267038
更新日期:2010-03-01 00:00:00
abstract::We propose a new starting point for comparing planar dose distributions using a Jacobian-based measure. The measure is normalization independent, i.e., is sensitive to dose patterns while not being biased by global dose scaling. The measure is free of tunable parameters and is bounded between zero and one. We also pro...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2982136
更新日期:2008-11-01 00:00:00
abstract::In this paper, two new boundary tracing algorithms for segmentation of breast masses are presented. These new algorithms are based on the dynamic programming-based boundary tracing (DPBT) algorithm proposed in Timp and Karssemeijer, [S. Timp and N. Karssemeijer, Med. Phys. 31, 958-971 (2004)] The DPBT algorithm contai...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2791034
更新日期:2007-11-01 00:00:00
abstract::Monte Carlo calculations have been performed for the purpose of characterizing the dosimetric properties of three brachytherapy sources. The three sources are manufactured by Syncor Pharmaceuticals Inc. and consist of two 125I seeds (BT-125-1 and BT-125-2) and one 103Pd seed (BT-103-3). The BT-125-1 and BT-125-2 seed ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1469627
更新日期:2002-05-01 00:00:00
abstract::Skeletal dosimetry based on microCT images of trabecular bone has recently been introduced to calculate the red bone marrow (RBM) and the bone surface cell (BSC) equivalent doses in human phantoms for external exposure to photons. In order to use the microCT images for skeletal dosimetry, spongiosa voxels in the skele...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3242266
更新日期:2009-11-01 00:00:00
abstract:PURPOSE:Adequate evaluation of the results from multi-institutional trials involving light ion beam treatments requires consideration of the planning margins applied to both targets and organs at risk. A major uncertainty that affects the size of these margins is the conversion of x ray computed tomography numbers (XCT...
journal_title:Medical physics
pub_type: 杂志文章,多中心研究
doi:10.1118/1.4870956
更新日期:2014-06-01 00:00:00
abstract::The relatively precise placement of brachytherapy sources afforded by stereotactic frames for brain implants is not generally achievable for other sites, which lack the fixed geometry of the cranium and its contents. An exception is a source-containing rigid mold that delivers brachytherapy when inserted securely in a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597454
更新日期:1995-03-01 00:00:00
abstract::Intensity modulated radiation therapy (IMRT) treatment planning typically considers beam optimization and beam delivery as separate tasks. Following optimization, a multi-leaf collimator (MLC) or other beam delivery device is used to generate fluence patterns for patient treatment delivery. Due to limitations and char...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1477230
更新日期:2002-06-01 00:00:00
abstract::In the present investigation, the necessary tests for implementing a quality assurance program for a commercial treatment planning system (TPS), recently installed at Sao Paulo University School of Medicine Clinicas Hospital-Brazil, was established and performed in accordance with the new IAEA publication TRS 430, and...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2742779
更新日期:2007-07-01 00:00:00
abstract:PURPOSE:Having been overlooked for many years, research is now starting to take into account the directional distribution of neutron workplace fields. Existing neutron dosimetry instrumentation does not account for this directional distribution, resulting in conservative estimates of dose in neutron workplace fields (b...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4964456
更新日期:2016-11-01 00:00:00
abstract:PURPOSE:Metal artifact reduction (MAR) is a major problem and a challenging issue in x-ray computed tomography (CT) examinations. Iterative reconstruction from sinograms unaffected by metals shows promising potential in detail recovery. This reconstruction has been the subject of much research in recent years. However,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4950722
更新日期:2016-06-01 00:00:00
abstract::Proton beams offer several advantages over conventional radiation techniques for treating cancer and other diseases. These advantages might be negated if the leakage and scatter radiation from the beamline and patient are too large. Although the leakage and scatter radiation for the double scattering proton beamlines ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2805086
更新日期:2008-01-01 00:00:00
abstract::Single photon emission computed tomography (SPECT) was investigated for imaging on-board radiation therapy machines in order to localize functional and molecular targets. A computer-simulated female NCAT phantom was positioned supine on a flat-top treatment couch. Twenty tumor locations were defined in the upper torso...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3113902
更新日期:2009-05-01 00:00:00
abstract:PURPOSE:To evaluate dosimetric variations of planning target volume (PTV) on critical organs such as rectal wall, bladder and femoral head, when the patient size changes due to weight loss in prostate volumetric modulated arc therapy (VMAT). METHODS:Three patients with small (32.0 cm3 ), medium (48.4 cm3 ) and large (...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735610
更新日期:2012-06-01 00:00:00
abstract::Current MRI nonuniformity correction techniques are reviewed and investigated. Many approaches are used to remedy this artifact, but it is not clear which method is the most appropriate in a given situation, as the applications have been with different MRI coils and different clinical applications. In this work four w...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.598357
更新日期:1998-09-01 00:00:00
abstract::Four different expressions, derived from the diffusion theory or the random walk model, were used to fit time-resolved reflectance data for the evaluation of tissue optical properties. The experimental reflectance curves were obtained from phantoms of known optical parameters (absorption and transport scattering coeff...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597739
更新日期:1996-09-01 00:00:00
abstract:PURPOSE:A series of examples are presented in which potential errors in the delivery of radiation therapy were prevented through use of incident learning. These examples underscore the value of reporting near miss incidents. METHODS:Using a departmental incident learning system, eight incidents were noted over a two-y...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4760774
更新日期:2012-11-01 00:00:00
abstract::Computed tomography dose index (CTDI) is a conventional indicator of the patient dose in CT studies. It is measured as the integration of the longitudinal single scan dose profile (SSDP) by using a 100-mm-long pencil ionization chamber and a single axial scan. However, the assumption that most of the SSDP is contained...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1835571
更新日期:2005-01-01 00:00:00
abstract::Tissue absorbed dose (D) is a computed result for internal emitters. For fixed geometries, D is calculated by a matrix (S) multiplication of the integrated activity vector (Ã). The last quantity is usually measured by nuclear imaging of activity in various source organs and performing a temporal integration. Ã is the ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735750
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:A 3-year project called LABSYNC has been recently funded by the European Commission, with the aim of designing a radiation facility based on a compact light source, i.e., a laboratory-sized commercial synchrotron, capable of accelerating electrons up to 6 or 20 MeV. An accurate spectral description of hard x ra...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3223357
更新日期:2009-10-01 00:00:00