Skeletal dosimetry for external exposures to photons based on microCT images of spongiosa: consideration of voxel resolution, cluster size, and medullary bone surfaces.

Abstract:

:Skeletal dosimetry based on microCT images of trabecular bone has recently been introduced to calculate the red bone marrow (RBM) and the bone surface cell (BSC) equivalent doses in human phantoms for external exposure to photons. In order to use the microCT images for skeletal dosimetry, spongiosa voxels in the skeletons were replaced at run time by so-called micromatrices, which have exactly the size of a spongiosa voxel and contain segmented trabecular bone and marrow micro-voxels. A cluster (=parallelepiped) of 2 x 2 x 2 = 8 micromatrices was used systematically and periodically throughout the spongiosa volume during the radiation transport calculation. Systematic means that when a particle leaves a spongiosa voxel to enter into a neighboring spongiosa voxel, then the next micromatrix in the cluster will be used. Periodical means that if the particle travels through more than two spongiosa voxels in a row, then the cluster will be repeated. Based on the bone samples available at the time, clusters of up to 3 x 3 x 3 = 27 micromatrices were studied. While for a given trabecular bone volume fraction the whole-body RBM equivalent dose showed converging results for cluster sizes between 8 and 27 micromatrices, this was not the case for the BSC equivalent dose. The BSC equivalent dose seemed to be very sensitive to the number, form, and thickness of the trabeculae. In addition, the cluster size and/or the microvoxel resolution were considered to be possible causes for the differences observed. In order to resolve this problem, this study used a bone sample large enough to extract clusters containing up to 8 x 8 x 8 = 512 micro-matrices and which was scanned with two different voxel resolutions. Taking into account a recent proposal, this investigation also calculated the BSC equivalent dose on medullary surfaces of cortical bone in the arm and leg bones. The results showed (1) that different voxel resolutions have no effect on the RBM equivalent dose but do influence the BSC equivalent dose due to voxel effects by up to 5% for incident photon energies up to 200 keV, (2) that the whole-body BSC equivalent dose calculated with a cluster with 2 x 2 x 2 = 8 micromatrices is consistent with results received with clusters of up to 8 x 8 x 8 = 512 micromatrices, and (3) that for external whole-body exposure the inclusion of the BSC on medullary surfaces of cortical bone has a negligible effect on the whole-body BSC equivalent dose.

journal_name

Med Phys

journal_title

Medical physics

authors

Kramer R,Khoury HJ,Vieira JW,Robson Brown KA

doi

10.1118/1.3242266

subject

Has Abstract

pub_date

2009-11-01 00:00:00

pages

5007-16

issue

11

eissn

0094-2405

issn

2473-4209

journal_volume

36

pub_type

杂志文章
  • Technical Note: Study of the electron transport parameters used in PENELOPE for the Monte Carlo simulation of Linac targets.

    abstract:PURPOSE:The Monte Carlo simulation of electron transport in Linac targets using the condensed history technique is known to be problematic owing to a potential dependence of absorbed dose distributions on the electron step length. In the PENELOPE code, the step length is partially determined by the transport parameters...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4916686

    authors: Rodriguez M,Sempau J,Brualla L

    更新日期:2015-06-01 00:00:00

  • Characterization of scintillator-based detectors for few-ten-keV high-spatial-resolution x-ray imaging.

    abstract:PURPOSE:High-spatial-resolution x-ray imaging in the few-ten-keV range is becoming increasingly important in several applications, such as small-animal imaging and phase-contrast imaging. The detector properties critically influence the quality of such imaging. Here the authors present a quantitative comparison of scin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4948687

    authors: Larsson JC,Lundström U,Hertz HM

    更新日期:2016-06-01 00:00:00

  • Target motion measurement without implanted markers and its validation by comparison with manually obtained data.

    abstract::For an effective radiotherapy the exact tumor location must be determined. The localization has to take into account patient's setup position as well as internal organ motion. Among the different localization methods, the use of a computer tomography (CT) scanner in the therapy room has been proposed recently. Achievi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2103447

    authors: Vences L,Wulf J,Vordermark D,Sauer O,Berlinger K,Roth M

    更新日期:2005-11-01 00:00:00

  • A fast, noniterative approach for accelerated high-temporal resolution cine-CMR using dynamically interleaved streak removal in the power-spectral encoded domain with low-pass filtering (DISPEL) and modulo-prime spokes (MoPS).

    abstract:PURPOSE:To introduce a pair of accelerated non-Cartesian acquisition principles that when combined, exploit the periodicity of k-space acquisition, and thereby enable acquisition of high-temporal cine Cardiac Magnetic Resonance (CMR). METHODS:The mathematical formulation of a noniterative, undersampled non-Cartesian c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12234

    authors: Kawaji K,Patel MB,Cantrell CG,Tanaka A,Marino M,Tamura S,Wang H,Wang Y,Carroll TJ,Ota T,Patel AR

    更新日期:2017-07-01 00:00:00

  • Broad line quantitative chemical shift spectroscopy.

    abstract::Proton NMR spectroscopy was applied to quantitate the measurement of total body water/fat distributions in vivo. A special MR protocol was developed to excite a thick slab of tissue and display the magnitude NMR spectrum of the collected response signal. Very short echo time TE (8 ms) and long repetition time TR (4000...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596935

    authors: Sobol WT,Elster AD,Hinson WH,Chwals WJ

    更新日期:1992-01-01 00:00:00

  • A framework for defining FLASH dose rate for pencil beam scanning.

    abstract:PURPOSE:To develop a method of (a) calculating the dose rate of voxels within a proton field delivered using pencil beam scanning (PBS), and (b) reporting a representative dose rate for the PBS treatment field that enables correspondence between multiple treatment modalities. This method takes into account the unique s...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14456

    authors: Folkerts MM,Abel E,Busold S,Perez JR,Krishnamurthi V,Ling CC

    更新日期:2020-12-01 00:00:00

  • WE-G-217A-08: Routine ACR SNR Measurement Failed to Detect 32-Channel Head Coil Receiver Malfunction.

    abstract:PURPOSE:To study if malfunction of a receiver can be detected robustly using the simple ACR SNR measurement approach on a 32-channel head coil. METHODS:Standard ACR T1W images (11slice) were acquired with a commercial 32 channel head coil on a 3T Philips Achieva MR scanner following the ACR recommended setup. Raw data...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736227

    authors: Peng Q

    更新日期:2012-06-01 00:00:00

  • Clinical implementation and commissioning of the MedAustron Particle Therapy Accelerator for non-isocentric scanned proton beam treatments.

    abstract:PURPOSE:This paper describes the clinical implementation and medical commissioning of the MedAustron Particle Therapy Accelerator (MAPTA) for non-isocentric scanned proton beam treatments. METHODS:Medical physics involvement during technical commissioning work is presented. Acceptance testing procedures, including adv...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13928

    authors: Grevillot L,Osorio Moreno J,Letellier V,Dreindl R,Elia A,Fuchs H,Carlino A,Kragl G,Palmans H,Vatnitsky S,Stock M

    更新日期:2020-02-01 00:00:00

  • High-resolution fiber-optic dosimeters for microbeam radiation therapy.

    abstract:PURPOSE:A high resolution, water equivalent, optical and passive x-ray dosimeter has been constructed using plastic scintillator and optical fiber. This dosimeter has a peak edge-on spatial resolution of 100 μm in one dimension, with a 10 μm resolution dosimeter under investigation. The dosimeter design has a potential...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12209

    authors: Archer J,Li E,Petasecca M,Lerch M,Rosenfeld A,Carolan M

    更新日期:2017-05-01 00:00:00

  • Portal dose image (PDI) prediction for dosimetric treatment verification in radiotherapy. I. An algorithm for open beams.

    abstract::A method is presented for calculation of transmission functions for high energy photon beams through patients. These functions are being used in our clinic for prediction of portal dose images (PDIs) which are compared with PDIs measured with an electronic portal imaging device (EPID). The calculations are based on th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598293

    authors: Pasma KL,Heijmen BJ,Kroonwijk M,Visser AG

    更新日期:1998-06-01 00:00:00

  • Patient dose simulations for scanning-beam digital x-ray tomosynthesis of the lungs.

    abstract:PURPOSE:An improved method of image guidance for lung tumor biopsies could help reduce the high rate of false negatives. The aim of this work is to optimize the geometry of the scanning-beam digital tomography system (SBDX) for providing real-time 3D tomographic reconstructions for target verification. The unique geome...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4826159

    authors: Nelson G,Yoon S,Krishna G,Wilfley B,Fahrig R

    更新日期:2013-11-01 00:00:00

  • A K alpha dual energy x-ray source for coronary angiography.

    abstract::The use of characteristic-line radiation from rare-earth targets bombarded by high-energy (up to 1 MeV) electron beams has been evaluated as an x-ray source for dual energy K-edge subtraction imaging of the human coronary arteries. Two characteristic-line x-ray sources, one using the split K alpha 1 and K alpha 2 line...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596648

    authors: Manning HL,Shefer RE,Klinkowstein RE,Mistretta CA

    更新日期:1991-09-01 00:00:00

  • Acuros CTS: A fast, linear Boltzmann transport equation solver for computed tomography scatter - Part I: Core algorithms and validation.

    abstract:PURPOSE:To describe Acuros® CTS, a new software tool for rapidly and accurately estimating scatter in x-ray projection images by deterministically solving the linear Boltzmann transport equation (LBTE). METHODS:The LBTE describes the behavior of particles as they interact with an object across spatial, energy, and dir...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12850

    authors: Maslowski A,Wang A,Sun M,Wareing T,Davis I,Star-Lack J

    更新日期:2018-05-01 00:00:00

  • A strategy to decrease partial scan reconstruction artifacts in myocardial perfusion CT: phantom and in vivo evaluation.

    abstract:PURPOSE:Partial scan reconstruction (PSR) artifacts are present in myocardial perfusion imaging using dynamic multidetector computed tomography (MDCT). PSR artifacts appear as temporal CT number variations due to inconsistencies in the angular data range used to reconstruct images and compromise the quantitative value ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3665767

    authors: Ramirez-Giraldo JC,Yu L,Kantor B,Ritman EL,McCollough CH

    更新日期:2012-01-01 00:00:00

  • Comparison of three strategies in management of independent movement of the prostate and pelvic lymph nodes.

    abstract:PURPOSE:Concurrent irradiation of the prostate and pelvic lymph nodes is technically challenging due to treating one moving target and one immobile target. The purposes of this article are to propose a new management strategy and to compare this strategy to the conventional isocenter shift method and the previously pro...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3480505

    authors: Xia P,Qi P,Hwang A,Kinsey E,Pouliot J,Roach M 3rd

    更新日期:2010-09-01 00:00:00

  • Parametrization of head-scatter factors for rectangular photon fields using an equivalent square formalism.

    abstract::Head-scatter factors of symmetric square and rectangular fields (field center on the central beam axis) defined by the upper (Y) and lower (X) jaws for 6 and 15 MV photon beams from 2300CD and 600C accelerators (Varian Associates, Inc., Palo Alto, CA) were measured, as well as those for fields shaped by the Y jaws and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597617

    authors: Yu MK,Murray B,Sloboda R

    更新日期:1995-08-01 00:00:00

  • Unequal weighting of given doses in opposed fields in treatment of cancer of the tonsillar region using 60Co, 4-, 8-, 15-, 24-MVp photons.

    abstract::Weighting of given doses from parallel opposed fields is a widespread practice in radiation therapy of cancer in the tonsillar region. In order to determine when weighting is useful, dose distributions on the central axis were calculated for various energies (60Co, 4-, 8-, 15-, and MVp photons), weighting factors, and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594276

    authors: Wollin M,Gilbert HA,Kagan AR

    更新日期:1976-03-01 00:00:00

  • Confirmation of a realistic reactor model for BNCT dosimetry at the TRIGA Mainz.

    abstract:PURPOSE:In order to build up a reliable dose monitoring system for boron neutron capture therapy (BNCT) applications at the TRIGA reactor in Mainz, a computer model for the entire reactor was established, simulating the radiation field by means of the Monte Carlo method. The impact of different source definition techni...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4897242

    authors: Ziegner M,Schmitz T,Khan R,Blaickner M,Palmans H,Sharpe P,Hampel G,Böck H

    更新日期:2014-11-01 00:00:00

  • Measurement of transit time of a remote after-loading high dose rate brachytherapy source.

    abstract::Quantification of transit time of a remote after-loading high dose rate (HDR) brachytherapy source is important both for accurate treatment planning and for quality assurance checks. In this investigation, an HDR-1000 well ionization chamber and a precision electrometer are used to measure the transit time of the Ir-1...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1386779

    authors: Sahoo N

    更新日期:2001-08-01 00:00:00

  • Poster - Thur Eve - 18: Characterization of a camera and LED lightbox imaging system for radiochromic film dosimetry.

    abstract::Radiation therapy treatment modalities continue to develop and have become increasingly complex. With this, dose verification and quality assurance (QA) is of great importance to ensure that a prescribed dose is accurately and precisely delivered to a patient. Radiochromic film dosimetry has been adopted as a convenie...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740126

    authors: Alexander K,Percy E,Olding T,Schreiner LJ,Salomons G

    更新日期:2012-07-01 00:00:00

  • Potential of high-Z contrast agents in clinical contrast-enhanced computed tomography.

    abstract:PURPOSE:Currently, only iodine- and barium-based contrast media (CM) are used in clinical contrast-enhanced computed tomography (CE-CT). High-Z metals would produce a higher contrast at equal mass density for the x-ray spectra used in clinical CT. Using such materials might allow for significant dose reductions in CE-C...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3658738

    authors: Nowak T,Hupfer M,Brauweiler R,Eisa F,Kalender WA

    更新日期:2011-12-01 00:00:00

  • Potential increase in biological effectiveness from field timing optimization for stereotactic body radiation therapy.

    abstract:PURPOSE:Stereotactic body radiation therapy (SBRT) is a radiotherapy technique which uses high dose fractions with multiple coplanar and noncoplanar beams. Due to the large fractional doses, treatments are typically protracted and there are more fields than in conventional radiation treatment schemes. The effect of tem...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4709605

    authors: Schmitt JD,Warren GW,Wang IZ

    更新日期:2012-06-01 00:00:00

  • Hybrid computational phantoms of the 15-year male and female adolescent: applications to CT organ dosimetry for patients of variable morphometry.

    abstract::Currently, two classes of the computational phantoms have been developed for dosimetry calculation: (1) stylized (or mathematical) and (2) voxel (or tomographic) phantoms describing human anatomy through mathematical surface equations and three-dimensional labeled voxel matrices, respectively. Mathematical surface equ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2912178

    authors: Lee C,Lodwick D,Williams JL,Bolch WE

    更新日期:2008-06-01 00:00:00

  • Signal, noise power spectrum, and detective quantum efficiency of indirect-detection flat-panel imagers for diagnostic radiology.

    abstract::The performance of an indirect-detection, active matrix flat-panel imager (FPI) at diagnostic energies is reported in terms of measured and theoretical signal size, noise power spectrum (NPS), and detective quantum efficiency (DQE). Based upon a 1536 x 1920 pixel, 127 microns pitch array of a-Si:H thin-film transistor...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598243

    authors: Siewerdsen JH,Antonuk LE,el-Mohri Y,Yorkston J,Huang W,Cunningham IA

    更新日期:1998-05-01 00:00:00

  • Calculation of monitor units for a linear accelerator with asymmetric jaws.

    abstract::A simple approach was developed that calculates the output factors and tissue maximum ratio of an asymmetric field at any point within the open field, and specifically both at the central axis (when the jaws do not shadow it) and at the effective center of the open field, using the existing tables for symmetric fields...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597524

    authors: Rosenberg I,Chu JC,Saxena V

    更新日期:1995-01-01 00:00:00

  • Treatment planning system and beam data validation for the ZAP-X: a novel self-shielded stereotactic radiosurgery system.

    abstract:PURPOSE:To evaluate the treatment planning system (TPS) performance of the ZAP-X stereotactic radiosurgery (SRS) system through nondosimetric, dosimetric, and end-to-end (E2E) tests. METHODS:A comprehensive set of TPS commissioning and validation tests were developed using published guidelines. Nondosimetric validatio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14740

    authors: Srivastava SP,Jani SS,Pinnaduwage DS,Yan X,Rogers L,Barranco FD,Barani IJ,Sorensen S

    更新日期:2021-01-28 00:00:00

  • Calculation of surface dose in rotational total skin electron irradiation.

    abstract::A single-field rotational total skin electron irradiation technique has recently been developed at the McGill University for treatment of skin malignancies. The dose received by a given surface point during rotation in a uniform large electron field depends on the radius of rotation of the surface point, on the local ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595524

    authors: Pla C,Heese R,Pla M,Podgorsak EB

    更新日期:1984-07-01 00:00:00

  • Measurement of neutron ambient dose equivalent in passive carbon-ion and proton radiotherapies.

    abstract::Secondary neutron ambient dose equivalents per the treatment absorbed dose in passive carbon-ion and proton radiotherapies were measured using a rem meter, WENDI-II at two carbon-ion radiotherapy facilities and four proton radiotherapy facilities in Japan. Our measured results showed that (1) neutron ambient dose equi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2989019

    authors: Yonai S,Matsufuji N,Kanai T,Matsui Y,Matsushita K,Yamashita H,Numano M,Sakae T,Terunuma T,Nishio T,Kohno R,Akagi T

    更新日期:2008-11-01 00:00:00

  • Image noise and dose performance across a clinical population: Patient size adaptation as a metric of CT performance.

    abstract:PURPOSE:Modern CT systems adjust X-ray flux accommodating for patient size to achieve certain image noise values. The effectiveness of this adaptation is an important aspect of CT performance and should ideally be characterized in the context of real patient cases. The objective of this study was to characterize CT per...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12172

    authors: Ria F,Wilson JM,Zhang Y,Samei E

    更新日期:2017-06-01 00:00:00

  • Invertibility of the dual energy x-ray data transform.

    abstract:PURPOSE:The Alvarez-Macovski method extracts the x-ray energy-dependent information by expanding the attenuation coefficient as a linear combination of functions of energy multiplied by basis set coefficients. Since the basis functions are known a priori, the coefficients represent all the energy-dependent information....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13255

    authors: Alvarez RE

    更新日期:2019-01-01 00:00:00