Broad line quantitative chemical shift spectroscopy.

Abstract:

:Proton NMR spectroscopy was applied to quantitate the measurement of total body water/fat distributions in vivo. A special MR protocol was developed to excite a thick slab of tissue and display the magnitude NMR spectrum of the collected response signal. Very short echo time TE (8 ms) and long repetition time TR (4000 ms) were used to minimize relaxation damping of the signal intensities. The spectrum was then decomposed into individual lines and proton densities of different species were calculated. Proton density information was converted into weight percentage data using stoichiometrical and physiological information. The technique was validated using phantoms that contained different mixtures of water/maize oil. A high-resolution NMR spectrum of maize oil samples was used to determine the stoichiometric information. The test results showed good agreement with the known composition of the phantom within the whole range of water content (0-100%). This method is very fast since no phase encoding of data is required. Preliminary results for monkeys show promising potential in clinical applications.

journal_name

Med Phys

journal_title

Medical physics

authors

Sobol WT,Elster AD,Hinson WH,Chwals WJ

doi

10.1118/1.596935

subject

Has Abstract

pub_date

1992-01-01 00:00:00

pages

61-9

issue

1

eissn

0094-2405

issn

2473-4209

journal_volume

19

pub_type

杂志文章
  • Device-dependent activity estimation and decay correction of radionuclide mixtures with application to Tc-94m PET studies.

    abstract::Multi-instrument activity estimation and decay correction techniques were developed for radionuclide mixtures, motivated by the desire for accurate quantitation of Tc-94m positron emission tomography (PET) studies. Tc-94m and byproduct Tc isotopes were produced by proton irradiation of enriched Mo-94 and natural Mo ta...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1333411

    authors: Smith MF,Daube-Witherspoon ME,Plascjak PS,Szajek LP,Carson RE,Everett JR,Green SL,Territo PR,Balaban RS,Bacharach SL,Eckelman WC

    更新日期:2001-01-01 00:00:00

  • State-of-the-art in two-dimensional ultrasonic transducer array technology.

    abstract::Attention is given to means of sensing ultrasonic energy distributions over an area. Under the restraints appropiate to real-time imaging of deep body organs, piezoelectric arrays offer the most promising method. Adaptation of integrated circuit techniques to array assembly permits very large arrays of small elements ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594247

    authors: Maginness MG,Plummer JD,Beaver WL,Meindl JD

    更新日期:1976-09-01 00:00:00

  • ARPM-net: A novel CNN-based adversarial method with Markov random field enhancement for prostate and organs at risk segmentation in pelvic CT images.

    abstract:PURPOSE:The research is to develop a novel CNN-based adversarial deep learning method to improve and expedite the multi-organ semantic segmentation of CT images and to generate accurate contours on pelvic CT images. METHODS:Planning CT and structure datasets for 120 patients with intact prostate cancer were retrospect...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14580

    authors: Zhang Z,Zhao T,Gay H,Zhang W,Sun B

    更新日期:2020-11-05 00:00:00

  • A formal study of lateral magnification and its influence on mammographic imaging sharpness.

    abstract::Radiographic magnification is often employed in mammography to improve detection of small anatomical details of clinical interest, such as microcalcifications. The image size depends on the conventional magnification factor, on the focal spot size, and on the x-ray angulation. In this paper magnification effects are i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597288

    authors: Schiabel H,Ventura A,Frère AF

    更新日期:1994-02-01 00:00:00

  • Projection-domain scatter correction for cone beam computed tomography using a residual convolutional neural network.

    abstract:PURPOSE:Scatter is a major factor degrading the image quality of cone beam computed tomography (CBCT). Conventional scatter correction strategies require handcrafted analytical models with ad hoc assumptions, which often leads to less accurate scatter removal. This study aims to develop an effective scatter correction ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13583

    authors: Nomura Y,Xu Q,Shirato H,Shimizu S,Xing L

    更新日期:2019-07-01 00:00:00

  • A fast, noniterative approach for accelerated high-temporal resolution cine-CMR using dynamically interleaved streak removal in the power-spectral encoded domain with low-pass filtering (DISPEL) and modulo-prime spokes (MoPS).

    abstract:PURPOSE:To introduce a pair of accelerated non-Cartesian acquisition principles that when combined, exploit the periodicity of k-space acquisition, and thereby enable acquisition of high-temporal cine Cardiac Magnetic Resonance (CMR). METHODS:The mathematical formulation of a noniterative, undersampled non-Cartesian c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12234

    authors: Kawaji K,Patel MB,Cantrell CG,Tanaka A,Marino M,Tamura S,Wang H,Wang Y,Carroll TJ,Ota T,Patel AR

    更新日期:2017-07-01 00:00:00

  • Toward adaptive radiotherapy for head and neck patients: Uncertainties in dose warping due to the choice of deformable registration algorithm.

    abstract:PURPOSE:The aims of this work were to evaluate the performance of several deformable image registration (DIR) algorithms implemented in our in-house software (NiftyReg) and the uncertainties inherent to using different algorithms for dose warping. METHODS:The authors describe a DIR based adaptive radiotherapy workflow...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4905050

    authors: Veiga C,Lourenço AM,Mouinuddin S,van Herk M,Modat M,Ourselin S,Royle G,McClelland JR

    更新日期:2015-02-01 00:00:00

  • Semiautomated four-dimensional computed tomography segmentation using deformable models.

    abstract::The purpose of this work is to demonstrate a proof of feasibility of the application of a commercial prototype deformable model algorithm to the problem of delineation of anatomic structures on four-dimensional (4D) computed tomography (CT) image data sets. We acquired a 4D CT image data set of a patient's thorax that...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1929207

    authors: Ragan D,Starkschall G,McNutt T,Kaus M,Guerrero T,Stevens CW

    更新日期:2005-07-01 00:00:00

  • Comparison of organ-at-risk sparing and plan robustness for spot-scanning proton therapy and volumetric modulated arc photon therapy in head-and-neck cancer.

    abstract:PURPOSE:Proton radiotherapy for head-and-neck cancer (HNC) aims to improve organ-at-risk (OAR) sparing over photon radiotherapy. However, it may be less robust for setup and range uncertainties. The authors investigated OAR sparing and plan robustness for spot-scanning proton planning techniques and compared these with...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4933245

    authors: Barten DL,Tol JP,Dahele M,Slotman BJ,Verbakel WF

    更新日期:2015-11-01 00:00:00

  • An investigation on the use of removal-diffusion theory for BNCT treatment planning: a method for determining proper removal-diffusion parameters.

    abstract::This paper outlines a method for determining proper removal-diffusion parameters to be used in removal-diffusion theory calculations for the purpose of BNCT treatment planning. Additionally, this paper demonstrates that, given the proper choice of removal-diffusion parameters, removal-diffusion theory may provide an a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1386424

    authors: Albertson BJ,Blue TE,Niemkiewicz J

    更新日期:2001-09-01 00:00:00

  • Contamination dose from photoneutron processes in bodily tissues during therapeutic radiation delivery.

    abstract::Dose to the total body from induced radiation resulting from primary exposure to radiotherapeutic beams is not detailed in routine treatment planning though this information is potentially important for better estimates of health risks including secondary cancers. This information can also allow better management of p...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1612947

    authors: Difilippo F,Papiez L,Moskvin V,Peplow D,DesRosiers C,Johnson J,Timmerman R,Randall M,Lillie R

    更新日期:2003-10-01 00:00:00

  • A simple test phantom for stereotactic computed tomography.

    abstract::An easy-to-use phantom has been constructed for checking the accuracy of a stereotactic computed tomography localization system. This phantom has been used on a commercially available stereotactic radiosurgery system. With this system, the phantom reference point, whose location is established by means of a precision ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597034

    authors: Ekstrand KE,Olds WW,Branch CL

    更新日期:1993-03-01 00:00:00

  • Incorporation of treatment plan spatial and temporal dose patterns into a prostate intrafractional motion management strategy.

    abstract:PURPOSE:Periodic MV∕KV radiographs taken during volumetric modulated arc therapy (VMAT) for hypofractionated treatment provide guidance in intrafractional motion management. The choice of imaging frequency and timing are key components in delivering the desired dose while reducing associated overhead such as imaging do...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4742846

    authors: Zhang P,Hunt M,Happersett L,Cox B,Mageras G

    更新日期:2012-09-01 00:00:00

  • Single shot MR tagging to quantify local tissue deformation during MRI-guided needle interventions: a feasibility study.

    abstract:PURPOSE:In MRI-guided needle interventions, such as biopsies and brachytherapy, tissue deformation caused by needle movement may result in localization errors and thus hamper the outcome of the procedure. Monitoring the local tissue deformation provides the ability to compensate for it, e.g., by increasing the needle i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3633906

    authors: van den Bosch MR,de Leeuw H,Zwanenburg JJ,Lagendijk JJ,Moerland MA

    更新日期:2011-10-01 00:00:00

  • Smoothing intensity-modulated treatment delivery under hardware constraints.

    abstract::A method is developed to smooth intensity-modulated beam delivery while considering hardware constraints. The method uses matrix algebra to model MLC leaf motion and hardware constraints such as interleaf digitization, synchronization requirements, and intersegment field abutment to deliver intensity modulated beam se...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1521121

    authors: Ma L

    更新日期:2002-12-01 00:00:00

  • Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning.

    abstract::The Monte Carlo (MC) method has been shown through many research studies to calculate accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient tissues where the effects of electron transport cannot be accurately handled with conventional, deterministic dose algorithms. Despite its p...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.2795842

    authors: Chetty IJ,Curran B,Cygler JE,DeMarco JJ,Ezzell G,Faddegon BA,Kawrakow I,Keall PJ,Liu H,Ma CM,Rogers DW,Seuntjens J,Sheikh-Bagheri D,Siebers JV

    更新日期:2007-12-01 00:00:00

  • Feasibility of estimating volumetric breast density from mammographic x-ray spectra using a cadmium telluride photon-counting detector.

    abstract:PURPOSE:Mammographic density of glandular breast tissue has a masking effect that can reduce lesion detection accuracy and is also a strong risk factor for breast cancer. Therefore, accurate quantitative estimation of breast density is clinically important. In this study, we investigate experimentally the feasibility o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13031

    authors: Ghammraoui B,Badal A,Glick SJ

    更新日期:2018-06-03 00:00:00

  • Calibrated breast density methods for full field digital mammography: a system for serial quality control and inter-system generalization.

    abstract:PURPOSE:The authors are developing a system for calibrated breast density measurements using full field digital mammography (FFDM). Breast tissue equivalent (BTE) phantom images are used to establish baseline (BL) calibration curves at time zero. For a given FFDM unit, the full BL dataset is comprised of approximately ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4903299

    authors: Lu B,Smallwood AM,Sellers TA,Drukteinis JS,Heine JJ,Fowler EE

    更新日期:2015-02-01 00:00:00

  • Comment on: Polarity effects and apparent ion recombination in microionization chambers Med. Phys. 43(5), 2141-2152 (2016).

    abstract::In a recent paper of Miller et al. (Med. Phys. 43(5), 2141-2152 (2016), the voltage dependence polarity effect of microionization chambers was studied. It was identified that polarity effect arises from the difference in electric potential between the collecting electrode and the guard electrode, which in turn deforms...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1002/mp.12019

    authors: Brivio D,Sajo E,Zygmanski P

    更新日期:2017-03-01 00:00:00

  • Computer-aided mass detection in mammography: false positive reduction via gray-scale invariant ranklet texture features.

    abstract::In this work, gray-scale invariant ranklet texture features are proposed for false positive reduction (FPR) in computer-aided detection (CAD) of breast masses. Two main considerations are at the basis of this proposal. First, false positive (FP) marks surviving our previous CAD system seem to be characterized by speci...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3049588

    authors: Masotti M,Lanconelli N,Campanini R

    更新日期:2009-02-01 00:00:00

  • Matching photon and electron fields with dynamic intensity modulation.

    abstract::A technique was developed to reduce the size and magnitude of the hot and cold spots in the abutting regions of photon and electron fields. The photon and electron fields were set up such that the photon field extended approximately 2 cm into the electron field in the abutting region. The region of the photon beam tha...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598753

    authors: Li JG,Xing L,Boyer AL,Hamilton RJ,Spelbring DR,Turian JV

    更新日期:1999-11-01 00:00:00

  • Application- and patient size-dependent optimization of x-ray spectra for CT.

    abstract::Although x-ray computed tomography (CT) has been in clinical use for over 3 decades, spectral optimization has not been a topic of great concern; high voltages around 120 kV have been in use since the beginning of CT. It is the purpose of this study to analyze, in a rigorous manner, the energies at which the patient d...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3075901

    authors: Kalender WA,Deak P,Kellermeier M,van Straten M,Vollmar SV

    更新日期:2009-03-01 00:00:00

  • Monte Carlo simulation of diagnostic x-ray scatter.

    abstract::A Monte Carlo method was developed and implemented to simulate x-ray photon transport. Simulations consisted of a pencil beam of monoenergetic photons with energies from 50 to 110 keV incident on water and aluminum slabs. The dependence of scatter fraction and multiple scattering on x-ray energy, scatterer thickness, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596268

    authors: Papin PJ,Rielly PS

    更新日期:1988-11-01 00:00:00

  • Dosimetric problems at low monitor unit settings for scanned and scattering foil electron beams.

    abstract::Electron beam dosimetry at low monitor unit (MU) settings is important for dosimetric applications. Dose linearity, beam flatness, and beam energies were studied at low MU settings with various dose rates for different types of linear accelerators. It is observed that for the scattering foil units, the dose/MU is a sm...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597328

    authors: Das IJ,Harrington JC,Akber SF,Tomer AF,Murray JC,Cheng CW

    更新日期:1994-06-01 00:00:00

  • TU-E-213AB-01: JMPSLC Has Morphed into Medical Physics Licensure and Regulatory Recognition Subcommittee.

    abstract::Based on direction from AAM Board of Directors, JMPLSC has redefined its scope and name. On November 4, 2011 the subcommittee renamed itself the Medical Physics Licensure and Regulatory Recognition Subcommittee. Its newly defined charge is to promote the protection of the public through the recognition of the professi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735947

    authors: Pizzutiello R

    更新日期:2012-06-01 00:00:00

  • On-board SPECT for localizing functional targets: a simulation study.

    abstract::Single photon emission computed tomography (SPECT) was investigated for imaging on-board radiation therapy machines in order to localize functional and molecular targets. A computer-simulated female NCAT phantom was positioned supine on a flat-top treatment couch. Twenty tumor locations were defined in the upper torso...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3113902

    authors: Roper J,Bowsher J,Yin FF

    更新日期:2009-05-01 00:00:00

  • Effective point of measurement of thimble ion chambers in megavoltage photon beams.

    abstract:PURPOSE:Determine the effective point of measurement (EPOM) of 12 thimble ion chambers, including miniature chambers and three models widely used for clinical reference dosimetry. The EPOM is the point at which the measured dose would arise in the measurement medium in the absence of the probe: For cylindrical chambers...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3266750

    authors: Tessier F,Kawrakow I

    更新日期:2010-01-01 00:00:00

  • Evaluation of the Gafchromic(®) EBT2 film for the dosimetry of radiosurgical beams.

    abstract:PURPOSE:Radiosurgery uses small fields and high-radiation doses to treat intra- and extracranial lesions in a single session. The lack of a lateral electronic equilibrium and the presence of high-dose gradients in these fields are challenges for adequate measurements. The availability of radiation detectors with the hi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4752211

    authors: Larraga-Gutierrez JM,Garcia-Hernandez D,Garcia-Garduno OA,Galvan de la Cruz OO,Ballesteros-Zebadua P,Esparza-Moreno KP

    更新日期:2012-10-01 00:00:00

  • Electron dosimetry based on the absorbed dose to water concept: a comparison of the AAPM TG-51 and DIN 6800-2 protocols.

    abstract::The dosimetry protocols DIN 6800-2 and AAPM TG-51, both based on the absorbed dose to water concept, are compared in their theoretical background and in their application to electron dosimetry. The agreement and disagreement in correction factors and energy parameters used in both protocols will be shown and discussed...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1414008

    authors: Dohm OS,Christ G,Nüsslin F,Schüle E,Bruggmoser G

    更新日期:2001-11-01 00:00:00

  • Medical applications of shortwave FM radar: remote monitoring of cardiac and respiratory motion.

    abstract:PURPOSE:This article introduces the use of low power continuous wave frequency modulated radar for medical applications, specifically for remote monitoring of vital signs in patients. METHODS:Gigahertz frequency radar measures the electromagnetic wave signal reflected from the surface of a human body and from tissue b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3267038

    authors: Mostov K,Liptsen E,Boutchko R

    更新日期:2010-03-01 00:00:00