Abstract:
PURPOSE:Determine the effective point of measurement (EPOM) of 12 thimble ion chambers, including miniature chambers and three models widely used for clinical reference dosimetry. The EPOM is the point at which the measured dose would arise in the measurement medium in the absence of the probe: For cylindrical chambers, it is shifted upstream relative to the central axis of the chamber. Although current dosimetry protocols prescribe a blanket upstream EPOM shift of 0.6r, with r as the chamber cavity radius, it has been shown in recent years that the EPOM does, in fact, depend on every detail of the chamber design and on the beam characteristics. In the wake of this finding, the authors undertake a comprehensive study of the EPOM for a series of chambers in water. METHODS:This work relies on EGSnrc Monte Carlo calculations for the central axis depth dose in a water phantom and in ion chambers. They use a full Elekta Precise linac treatment head simulation to generate realistic photon beams with nominal energies of 6 and 25 MV and fields sizes of 10 x 10 and 40 x 40 cm2. The correct EPOM shift for the 12 ion chambers, modeled in realistic detail, is taken as the one minimizing the deviation of the ratio between the dose to water and the dose to the gas of the chamber cavity, according to a method proposed and validated in previous work. RESULTS:The analysis reveals that the actual EPOM shift is significantly smaller than the recommended value in current dosimetry protocols, by up to 25% for reference-class chambers and 80% for miniature chambers. The location of the EPOM also depends on the characteristics of the incident beam and varies in a well-defined way with the cavity length, the central electrode radius, and the thimble wall thickness. CONCLUSIONS:The authors confirm that an upstream EPOM shift of 0.6r is too large for thimble ion chambers in high energy photon beams. Proper values for the EPOM shift could be tabulated per beam and per chamber, but they envisage that a single shift for all practical beams may prove sufficient. Moreover, the systematic dependence on chamber characteristics provides evidence that a universal parametrization in terms of a few design parameters is conceivable and has implication for the calculation of chamber correction factors.
journal_name
Med Physjournal_title
Medical physicsauthors
Tessier F,Kawrakow Idoi
10.1118/1.3266750subject
Has Abstractpub_date
2010-01-01 00:00:00pages
96-107issue
1eissn
0094-2405issn
2473-4209journal_volume
37pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:To use Cone Beam CT scans obtained just prior to treatments of head and neck cancer patients to measure the setup error and cumulative dose uncertainty of the cochlea. METHODS:Data from 10 head and neck patients with 10 planning CTs and 52 Cone Beam CTs taken at time of treatment were used in this study. Patie...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4830427
更新日期:2013-12-01 00:00:00
abstract::With the increased sophistication of lasers used for patient positioning in radiotherapy comes increased possibilities for mistakes in installing the lasers, which can result in serious patient positioning errors. Two principles must be followed when mounting cross-projecting lasers: (1) the horizontal line must be on...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594960
更新日期:1981-05-01 00:00:00
abstract::We investigated the utility of three manual planimetric methods to quantify carotid plaque volume. A single observer measured 15 individual plaques from 15 three-dimensional (3D) ultrasound (3D US) images of patients ten times each using three different planimetric approaches. Individual plaque volumes were measured (...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2715487
更新日期:2007-04-01 00:00:00
abstract::Electron spectral reconstruction of medical accelerators from measured depth doses is a practical method for providing the input initial phase space distribution at the patient surface that is required by Monte Carlo treatment planning systems. The posed inverse problem of spectral reconstruction is ill conditioned an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2161404
更新日期:2006-02-01 00:00:00
abstract:PURPOSE:For stereotactic radiosurgery (SRS), accurate evaluation of dose-volume metrics for small structures is necessary. The purpose of this study was to compare the DVH metric capabilities of five commercially available SRS DVH analysis tools (Eclipse, Elements, Raystation, MIM, and Velocity). METHODS:DICOM RTdose ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14645
更新日期:2020-12-09 00:00:00
abstract:PURPOSE:To develop a novel three-dimensional (3D) hybrid-encoding framework using compressed sensing (CS) and Toeplitz encoding with variable phase-scrambled radio-frequency (RF) excitation, which has the following advantages: low power deposition of RF pulses, reduction of the signal dynamic range, no additional hardw...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13987
更新日期:2020-04-01 00:00:00
abstract::The aim of the current study was to (a) provide normalized dose data for the estimation of the radiation dose from upper gastrointestinal tract contrast (UGIC) studies carried out to infants and (b) estimate the average patient dose and risks associated with radiation from UGIC examinations performed in our institutio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2181297
更新日期:2006-04-01 00:00:00
abstract::Quantitative evaluation of cardiac image data obtained using multidetector row computed tomography (CT) is compromised by partial scan reconstructions, which improve the temporal resolution but significantly increase image-to-image CT number variations for a fixed region of interest compared to full reconstruction ima...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2805476
更新日期:2007-12-01 00:00:00
abstract::Ultrasound-induced blood stasis has been observed for more than 30 years. Most of the literature has been focused on the health risks associated with this phenomenon and methods employed to prevent stasis from occurring during ultrasound imaging. To date, experimental observations have been either in vitro or invasive...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2198196
更新日期:2006-06-01 00:00:00
abstract::In a practical classifier design problem, the true population is generally unknown and the available sample is finite-sized. A common approach is to use a resampling technique to estimate the performance of the classifier that will be trained with the available sample. We conducted a Monte Carlo simulation study to co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2868757
更新日期:2008-04-01 00:00:00
abstract::Although x-ray computed tomography (CT) has been in clinical use for over 3 decades, spectral optimization has not been a topic of great concern; high voltages around 120 kV have been in use since the beginning of CT. It is the purpose of this study to analyze, in a rigorous manner, the energies at which the patient d...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3075901
更新日期:2009-03-01 00:00:00
abstract:PURPOSE:The purpose of this study was to develop a dual-modality positron emission tomography (PET)/magnetic resonance imaging (MRI) with insertable PET for simultaneous PET and MR imaging of the human brain. METHODS:The PET detector block was composed of a 4 × 4 matrix of detector modules, each consisting of a 4 × 4 ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4918321
更新日期:2015-05-01 00:00:00
abstract:PURPOSE:Alpha-emitting radionuclides exhibit a potential advantage for cancer treatments because they release large amounts of ionizing energy over a few cell diameters (50-80 μm), causing localized, irreparable double-strand DNA breaks that lead to cell death. Radioimmunotherapy (RIT) approaches using monoclonal antib...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4921997
更新日期:2015-07-01 00:00:00
abstract:PURPOSE:A prototype in-house program was developed to assist deriving image guidance shifts clinically using our 4DCT method for lung SBRT. METHODS:Our in-house prototype program was implemented in MATLAB. The 4D DICOM CT dataset of interest is imported by the program from AW and subsequently accepts input from the us...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735493
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:In 3D gradient echo magnetic resonance imaging (MRI), strong field gradients B0macro are visually observed at air/tissue interfaces. At low spatial resolution in particular, the respective field gradients lead to an apparent increase in intravoxel dephasing, and subsequently, to signal loss or inaccurate R2* es...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12318
更新日期:2017-07-01 00:00:00
abstract:PURPOSE:On-board MRI can provide superb soft tissue contrast for improving liver SBRT localization. However, the availability of on-board MRI in clinics is extremely limited. On the contrary, on-board kV imaging systems are widely available on radiotherapy machines, but its capability to localize tumors in soft tissue ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12998
更新日期:2018-07-01 00:00:00
abstract::A water beam imaging system (WBIS) has been developed and used to verify dose distributions for intensity modulated radiotherapy using dynamic multileaf collimator. This system consisted of a water container, a scintillator screen, a charge-coupled device camera, and a portable personal computer. The scintillation ima...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1413519
更新日期:2001-12-01 00:00:00
abstract:PURPOSE:Theoretical reasoning suggests that direct conversion digital x-ray detectors based upon photoconductive amorphous-selenium (a-Se) could attain very high values of the MTF (modulation transfer function) at spatial frequencies well beyond 20 cycles mm(-1). One of the fundamental factors affecting resolution loss...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3673957
更新日期:2012-02-01 00:00:00
abstract::Electron beam dosimetry at low monitor unit (MU) settings is important for dosimetric applications. Dose linearity, beam flatness, and beam energies were studied at low MU settings with various dose rates for different types of linear accelerators. It is observed that for the scattering foil units, the dose/MU is a sm...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597328
更新日期:1994-06-01 00:00:00
abstract::Two experimental methods are described for obtaining average energies of neutron spectra produced by an electron accelerator in a medical treatment room. In the first method, the dose equivalent is measured by means of indium activation foils in an Andersson-Braun moderator. Fluences are determined by the usual activa...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595662
更新日期:1985-11-01 00:00:00
abstract:PURPOSE:Potential collision between the patient∕couch and the gantry could delay the start of the treatment and reduce clinical efficiency. The ability to accurately detect possible collisions during the treatment planning phase is desired. Such collision detection should account for the specific proton gantry design, ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4760988
更新日期:2012-11-01 00:00:00
abstract::Generating an optimized radiation treatment plan requires understanding the factors affecting tumour control. Mathematical models of tumour dynamics may help in future studies of factors predicting tumor sensitivity to radiotherapy. In this study, a time-dependent differential model, incorporating biological cancer ma...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2965923
更新日期:2008-07-01 00:00:00
abstract::The implementation of an improved model for multiple scattering into the-Voxel Monte Carlo (VMC) algorithm for fast electron dose calculation in radiation therapy is presented. The model takes into account path-length corrections (PLC) and lateral displacement in the individual electron steps. The extraction of the sc...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597933
更新日期:1997-04-01 00:00:00
abstract:PURPOSE:A nanodosimeter is a type of detector which measures single ionizations in a small gaseous volume in order to obtain ionization cluster size probability distributions for characterization of radiation types. Working nanodosimeter detectors are usually bulky machines which require a lot of space. In this work, t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14738
更新日期:2021-01-28 00:00:00
abstract::We have developed an analytic solution for spatially resolved diffuse reflectance within the deltaP1 approximation to the radiative transport equation for a semi-infinite homogeneous turbid medium. We evaluate the performance of this solution by comparing its predictions with those provided by Monte Carlo simulations ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2828184
更新日期:2008-02-01 00:00:00
abstract::We investigated protection strategies of organs at risk (OARs) in intensity modulated radiation therapy (IMRT). These strategies apply to delivery of IMRT to moving body anatomies that show relative displacement of OAR in close proximity to a tumor target. We formulated an efficient genetic algorithm which makes it po...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3132305
更新日期:2009-07-01 00:00:00
abstract:PURPOSE:External beam radiation therapy (EBRT) usually uses heterogeneous dose distributions in a given volume. Designing detectors for quality control of these treatments is still a developing subject. The size of the detectors should be small to enhance spatial resolution and ensure low perturbation of the beam. A hi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4837178
更新日期:2014-01-01 00:00:00
abstract:PURPOSE:There is significant current interest in the use of biological image guidance in radiotherapy planning. In lung-cancer treatment, tumor motion due to respiration is known to be a limitation. This is particularly true in PET, where image data are collected over a number of minutes. An in-house-developed 4D PET a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3276776
更新日期:2010-02-01 00:00:00
abstract:PURPOSE:The Small Animal Radiation Research Platform (SARRP) has been developed for conformal microirradiation with on-board cone beam CT (CBCT) guidance. The graphics processing unit (GPU)-accelerated Superposition-Convolution (SC) method for dose computation has been integrated into the treatment planning system (TPS...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12862
更新日期:2018-05-01 00:00:00
abstract::Calibration of an imported strontium-90 ophthalmic applicator at the U.S. National Bureau of Standards (now the National Institute of Standards and Technology) has disclose a significant discrepancy in dose rate calibration (32%-35%) with that quoted by the manufacturer. The University of Wisconsin has investigated th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596702
更新日期:1991-03-01 00:00:00