General strategy for the protection of organs at risk in IMRT therapy of a moving body.

Abstract:

:We investigated protection strategies of organs at risk (OARs) in intensity modulated radiation therapy (IMRT). These strategies apply to delivery of IMRT to moving body anatomies that show relative displacement of OAR in close proximity to a tumor target. We formulated an efficient genetic algorithm which makes it possible to search for global minima in a complex landscape of multiple irradiation strategies delivering a given, predetermined intensity map to a target. The optimal strategy was investigated with respect to minimizing the dose delivered to the OAR. The optimization procedure developed relies on variability of all parameters available for control of radiation delivery in modern linear accelerators, including adaptation of leaf trajectories and simultaneous modification of beam dose rate during irradiation. We showed that the optimization algorithms lead to a significant reduction in the dose delivered to OAR in cases where organs at risk move relative to a treatment target.

journal_name

Med Phys

journal_title

Medical physics

authors

Abolfath RM,Papiez L

doi

10.1118/1.3132305

subject

Has Abstract

pub_date

2009-07-01 00:00:00

pages

3013-7

issue

7

eissn

0094-2405

issn

2473-4209

journal_volume

36

pub_type

杂志文章
  • Anatomical pulmonary magnetic resonance imaging segmentation for regional structure-function measurements of asthma.

    abstract:PURPOSE:Pulmonary magnetic-resonance-imaging (MRI) and x-ray computed-tomography have provided strong evidence of spatially and temporally persistent lung structure-function abnormalities in asthmatics. This has generated a shift in their understanding of lung disease and supports the use of imaging biomarkers as inter...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4948999

    authors: Guo F,Svenningsen S,Eddy RL,Capaldi DPI,Sheikh K,Fenster A,Parraga G

    更新日期:2016-06-01 00:00:00

  • An experimental palladium-103 seed (OptiSeedexp) in a biocompatible polymer without a gold marker: characterization of dosimetric parameters including the interseed effect.

    abstract::Permanent implantation of 125I (iodine) or 103Pd (palladium) sources is a popular treatment option in the management of early stage prostate cancer. New sources are being developed, some of which are being marketed for different clinical applications. A new technique of adjuvant stereotactic permanent seed breast impl...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3006151

    authors: Abboud F,Scalliet P,Vynckier S

    更新日期:2008-12-01 00:00:00

  • Technical Note: 4D cone-beam CT reconstruction from sparse-view CBCT data for daily motion assessment in pencil beam scanned proton therapy (PBS-PT).

    abstract:PURPOSE:The number of pencil beam scanned proton therapy (PBS-PT) facilities equipped with cone-beam computed tomography (CBCT) imaging treating thoracic indications is constantly rising. To enable daily internal motion monitoring during PBS-PT treatments of thoracic tumors, we assess the performance of Motion-Aware Re...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14521

    authors: den Otter LA,Chen K,Janssens G,Meijers A,Both S,Langendijk JA,Rosen LR,Wu HT,Knopf AC

    更新日期:2020-12-01 00:00:00

  • Technical note: patient-specific quality assurance methods for TomoDirect(TM) whole breast treatment delivery.

    abstract:PURPOSE:To investigate the feasibility of implementing a novel approach for patient-specific QA of TomoDirect(TM) whole breast treatment. METHODS:The most currently used TomoTherapy DQA method, consisting in the verification of the 2D dose distribution in a coronal or sagittal plane of the Cheese Phantom by means of g...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4722967

    authors: Catuzzo P,Zenone F,Aimonetto S,Peruzzo A,Casanova Borca V,Pasquino M,Franco P,La Porta MR,Ricardi U,Tofani S

    更新日期:2012-07-01 00:00:00

  • Automatic detection of simulated motion blur in mammograms.

    abstract:PURPOSE:To use machine-learning algorithms and blur measure (BM) operators to automatically detect motion blur in mammograms. Motion blur has been reported to reduce lesion detection performance and mask small abnormalities, resulting in failure to detect them until they reach more advanced stages. Automatic detection ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14069

    authors: Kamona N,Loew M

    更新日期:2020-04-01 00:00:00

  • Analysis and correction of imperfections in the image intensifier-TV-digitizer imaging chain.

    abstract::Image intensifier-television-video digitizer (IITVD) systems are commonly used for digital planar image acquisition in radiology. However, the well-known distortions inherent in these systems limit their utility in research and in some clinical applications where quantitatively correct images are required. Software co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596718

    authors: Boone JM,Seibert JA,Barrett WA,Blood EA

    更新日期:1991-03-01 00:00:00

  • Fully automatic deformable registration of pretreatment MRI/CT for image-guided prostate radiotherapy planning.

    abstract:PURPOSE:In prostate radiotherapy, dose distribution may be calculated on CT images, while the MRI can be used to enhance soft tissue visualization. Therefore, a registration between MR and CT images could improve the overall treatment planning process, by improving visualization with a demonstrated interobserver deline...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12629

    authors: Hamdan I,Bert J,Rest CCL,Tasu JP,Boussion N,Valeri A,Dardenne G,Visvikis D

    更新日期:2017-12-01 00:00:00

  • The x-ray time of flight method for investigation of ghosting in amorphous selenium-based flat panel medical x-ray imagers.

    abstract::Amorphous selenium (a-Se) based real-time flat-panel imagers (FPIs) are finding their way into the digital radiology department because they offer the practical advantages of digital x-ray imaging combined with an image quality that equals or outperforms that of conventional systems. The temporal imaging characteristi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2042248

    authors: Rau AW,Bakueva L,Rowlands JA

    更新日期:2005-10-01 00:00:00

  • Determination of x-ray tube focal spot position.

    abstract::In x-ray spectral measurement using a semiconductor detector system, accurate positioning of the detector in front of the anode is very important. This needs accurate determination of the focal spot position on the target in an x-ray tube. We present a simple technique to determine the focal spot position accurately. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597122

    authors: Kubota H,Ozaki Y,Matsumoto M,Kanamori H

    更新日期:1993-07-01 00:00:00

  • Imaging of moving fiducial markers during radiotherapy using a fast, efficient active pixel sensor based EPID.

    abstract:PURPOSE:The purpose of this work was to investigate the use of an experimental complementary metal-oxide-semiconductor (CMOS) active pixel sensor (APS) for tracking of moving fiducial markers during radiotherapy. METHODS:The APS has an active area of 5.4 × 5.4 cm and maximum full frame read-out rate of 20 frame s(-1),...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3651632

    authors: Osmond JP,Zin HM,Harris EJ,Lupica G,Allinson NM,Evans PM

    更新日期:2011-11-01 00:00:00

  • Experimental study of the relationship between the base impedance and its time derivative in impedance plethysmography.

    abstract::Transthoracic electrical impedance Z consists of a constant baseline component Z0 and the time variable component delta Z such that Z = Z0 + delta Z. The first time derivative of Z has a negative peak, the magnitude of which is (dZ/dt)min. Measurements of 170 volunteers show that (dZ/dt)min is a function of the consta...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594910

    authors: Djordjevich L,Sadove MS

    更新日期:1981-01-01 00:00:00

  • SU-E-T-231: Comparison of Beam Characteristics of Small Field 6 MeV Electrons as Replacement for Superficial X Ray Beam.

    abstract:PURPOSE:To compare beam characteristics of superficial X-rays with 6 MeV Electrons for the purpose of replacing superficial treatments with electron fields for skin lesions. METHODS:Electron beam cutouts were made with 12mm thickness cerrobend in diameters 2-5 cm to match superficial X-ray machine cones. Central axis ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735294

    authors: Avadhani J,Sasidharan S,Carton C,Lowen M,Klapproth T,Licitra C

    更新日期:2012-06-01 00:00:00

  • Dose planning with comparison to in vivo dosimetry for epithermal neutron irradiation of the dog brain.

    abstract::Boron neutron capture therapy (BNCT) is an experimental type of radiotherapy, presently being used to treat glioblastoma and melanoma. To improve patient safety and to determine the radiobiological characteristics of the epithermal neutron beam of Finnish BNCT facility (FiR 1) dose-response studies were carried on the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1517048

    authors: Seppälä T,Auterinen I,Aschan C,Serén T,Benczik J,Snellman M,Huiskamp R,Ramadan UA,Kankaanranta L,Joensuu H,Savolainen S

    更新日期:2002-11-01 00:00:00

  • Repeatability of SUV measurements in serial PET.

    abstract:PURPOSE:The standardized uptake value (SUV) is a quantitative measure of FDG tumor uptake frequently used as a tool to monitor therapeutic response. This study aims to (i) assess the reproducibility and uncertainty of SUV max and SUV mean, due to purely statistical, i.e., nonbiological, effects and (ii) to establish th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3578604

    authors: Schwartz J,Humm JL,Gonen M,Kalaigian H,Schoder H,Larson SM,Nehmeh SA

    更新日期:2011-05-01 00:00:00

  • A Monte Carlo comparison of the response of the PTW-diamond and the TL-diamond detectors in megavoltage photon beams.

    abstract::A detailed Monte Carlo study of the PTW-diamond solid state detector response in megavoltage photon beams (60Co gamma rays to 25 MV x rays) has been performed with the EGS4 Monte Carlo Code. The sensitive volume of the diamond detector is a disk of diameter 4.4 mm and thickness 0.40 mm. The phantom material was water ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598771

    authors: Mobit PN,Sandison GA

    更新日期:1999-11-01 00:00:00

  • An MLC calibration method using a detector array.

    abstract:PURPOSE:The authors have developed a quantitative calibration method for a multileaf collimator (MLC) which measures individual leaf positions relative to the MLC backup jaw on an Elekta Synergy linear accelerator. METHODS:The method utilizes a commercially available two-axis detector array (Profiler 2; Sun Nuclear Co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3218767

    authors: Simon TA,Kahler D,Simon WE,Fox C,Li J,Palta J,Liu C

    更新日期:2009-10-01 00:00:00

  • Multiscale entropy of laser Doppler flowmetry signals in healthy human subjects.

    abstract:PURPOSE:The cardiovascular system (CVS) regulation can be studied from a central viewpoint, through heart rate variability (HRV) data, and from a peripheral viewpoint, through laser Doppler flowmetry (LDF) signals. Both the central and peripheral CVSs are regulated by several interacting mechanisms, each having its own...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3512796

    authors: Humeau A,Buard B,Mahé G,Rousseau D,Chapeau-Blondeau F,Abraham P

    更新日期:2010-12-01 00:00:00

  • Evaluating IMRT and VMAT dose accuracy: practical examples of failure to detect systematic errors when applying a commonly used metric and action levels.

    abstract:PURPOSE:This study (1) examines a variety of real-world cases where systematic errors were not detected by widely accepted methods for IMRT/VMAT dosimetric accuracy evaluation, and (2) drills-down to identify failure modes and their corresponding means for detection, diagnosis, and mitigation. The primary goal of detai...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4826166

    authors: Nelms BE,Chan MF,Jarry G,Lemire M,Lowden J,Hampton C,Feygelman V

    更新日期:2013-11-01 00:00:00

  • Energy spectra due to the intrinsic radiation of LYSO/LSO scintillators for a wide range of crystal sizes.

    abstract::Most detectors in current positron emission tomography (PET) scanners and prototypes use lutetium oxyorthosilicate (LSO) or lutetium yttrium oxyorthosilicate (LYSO) scintillators. The aim of this work is to provide a complete set of background energy spectra, due to the scintillator intrinsic radioactivity, for a wide...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14729

    authors: Domínguez-Jiménez DY,Alva-Sánchez H

    更新日期:2021-01-21 00:00:00

  • Adaptation of a clustered lumpy background model for task-based image quality assessment in x-ray phase-contrast mammography.

    abstract:PURPOSE:Since the introduction of clinical x-ray phase-contrast mammography (PCM), a technique that exploits refractive-index variations to create edge enhancement at tissue boundaries, a number of optimization studies employing physical image-quality metrics have been performed. Ideally, task-based assessment of PCM w...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3676183

    authors: Zysk AM,Brankov JG,Wernick MN,Anastasio MA

    更新日期:2012-02-01 00:00:00

  • The use of PET images for radiotherapy treatment planning: an error analysis using radiobiological endpoints.

    abstract:PURPOSE:There is significant current interest in the use of biological image guidance in radiotherapy planning. In lung-cancer treatment, tumor motion due to respiration is known to be a limitation. This is particularly true in PET, where image data are collected over a number of minutes. An in-house-developed 4D PET a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3276776

    authors: Perrin R,Evans PM,Webb S,Partridge M

    更新日期:2010-02-01 00:00:00

  • Photon dose calculation incorporating explicit electron transport.

    abstract::Significant advances have been made in recent years to improve photon dose calculation. However, accurate prediction of dose perturbation effects near the interfaces of different media, where charged particle equilibrium is not established, remain unsolved. Furthermore, changes in atomic number, which affect the multi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597611

    authors: Yu CX,Mackie TR,Wong JW

    更新日期:1995-07-01 00:00:00

  • Characteristics of metal-plate/film detectors at therapy energies. II. Detective quantum efficiency.

    abstract::Noise power spectrum (NPS) and detective quantum efficiency (DQE) for metal-plate/film portal detectors are reported for the Co-60 and Linac 10 MV spectra. The detectors consist of a double-emulsion portal film secured between plates of aluminum, copper, brass, or lead. The NPS was found to be independent of the detec...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598437

    authors: Falco T,Fallone BG

    更新日期:1998-12-01 00:00:00

  • Comparison of quantitative Y-90 SPECT and non-time-of-flight PET imaging in post-therapy radioembolization of liver cancer.

    abstract:PURPOSE:Radioembolization with yttrium-90 microspheres may be optimized with patient-specific pretherapy treatment planning. Dose verification and validation of treatment planning methods require quantitative imaging of the post-therapy distribution of yttrium-90 (Y-90). Methods for quantitative imaging of Y-90 using b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4962472

    authors: Yue J,Mauxion T,Reyes DK,Lodge MA,Hobbs RF,Rong X,Dong Y,Herman JM,Wahl RL,Geschwind JH,Frey EC

    更新日期:2016-10-01 00:00:00

  • A quality assurance program for monitor unit calculators.

    abstract::A quality assurance protocol has been developed to assess the relative accuracy of computerized monitor unit calculations. Results from this testing reveal that errors (defined as the difference between the computer results and those obtained using a standard formula with manual calculation) in monitor unit calculator...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596539

    authors: Dahl RA,McCullough EC,Mellenberg DE

    更新日期:1990-01-01 00:00:00

  • Application of radiomics for the prediction of HPV status for patients with head and neck cancers.

    abstract:PURPOSE:To perform radiomic analysis of primary tumors extracted from pretreatment contrast-enhanced computed tomography (CE-CT) images for patients with oropharyngeal cancers to identify discriminant features and construct an optimal classifier for the characterization and prediction of human papilloma virus (HPV) sta...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13977

    authors: Bagher-Ebadian H,Lu M,Siddiqui F,Ghanem AI,Wen N,Wu Q,Liu C,Movsas B,Chetty IJ

    更新日期:2020-02-01 00:00:00

  • DCE-MRI defined subvolumes of a brain metastatic lesion by principle component analysis and fuzzy-c-means clustering for response assessment of radiation therapy.

    abstract:PURPOSE:To develop a pharmacokinetic modelfree framework to analyze the dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) data for assessment of response of brain metastases to radiation therapy. METHODS:Twenty patients with 45 analyzable brain metastases had MRI scans prior to whole brain radiation thera...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4842556

    authors: Farjam R,Tsien CI,Lawrence TS,Cao Y

    更新日期:2014-01-01 00:00:00

  • SU-E-I-57: CT Dose Metrics: What Are We Tracking.

    abstract:PURPOSE:Recent guidance by The Joint Commission and CRCPD recommendations require establishing CT reference dose levels (RDLs) for clinical protocols and recording CT dose metrics in the patient's medical record. This presentation addresses which dose values in the CT report should be recorded for the purposes of monit...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734773

    authors: Guild J,Arbique G,Blackburn T,Gallet J,Anderson J

    更新日期:2012-06-01 00:00:00

  • Characterization of electron contamination in megavoltage photon beams.

    abstract::The purpose of the present study is to characterize electron contamination in photon beams in different clinical situations. Variations with field size, beam modifier (tray, shaping block) and source-surface distance (SSD) were studied. Percentage depth dose measurements with and without a purging magnet and replacing...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1895793

    authors: Lopez Medina A,Teijeiro A,Garcia J,Esperon J,Terron JA,Ruiz DP,Carrion MC

    更新日期:2005-05-01 00:00:00

  • A framework for quantification and visualization of segmentation accuracy and variability in 3D lateral ventricle ultrasound images of preterm neonates.

    abstract:PURPOSE:Intraventricular hemorrhage (IVH) is a major cause of brain injury in preterm neonates. Three dimensional ultrasound (US) imaging systems have been developed to visualize 3D anatomical structure of preterm neonatal intracranial ventricular system with IVH and ventricular dilation. To allow quantitative analysis...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4932366

    authors: Chen Y,Qiu W,Kishimoto J,Gao Y,Chan RH,de Ribaupierre S,Fenster A,Chiu B

    更新日期:2015-11-01 00:00:00