A framework for quantification and visualization of segmentation accuracy and variability in 3D lateral ventricle ultrasound images of preterm neonates.

Abstract:

PURPOSE:Intraventricular hemorrhage (IVH) is a major cause of brain injury in preterm neonates. Three dimensional ultrasound (US) imaging systems have been developed to visualize 3D anatomical structure of preterm neonatal intracranial ventricular system with IVH and ventricular dilation. To allow quantitative analysis, the ventricle system is required to be segmented accurately and efficiently from 3D US images. Although semiautomatic segmentation algorithms have been developed, local segmentation accuracy and variability associated with these algorithms should be evaluated statistically before they can be applied in clinical settings. This work proposes a statistical framework to quantify the local accuracy and variability and performs statistical tests to identify locations where the semiautomatically segmented surfaces are significantly different from manually segmented surfaces. METHODS:Three dimensional lateral ventricle US images of preterm neonates were each segmented six times manually and using a semiautomated segmentation algorithm. The local difference between manually and algorithmically segmented surfaces as well as the segmentation variability for each method was computed and superimposed on the ventricular surface of each subject. To summarize the segmentation performance for a whole group of subjects, the subject-specific local difference and standard deviation maps were registered onto a 3D template ventricular surface using a nonrigid registration algorithm. Pointwise, intersubject average accuracy and pooled variability for the whole group of subjects can be computed and visualized on the template surface, providing a summary of performance of the segmentation algorithm for the whole group of ventricles with highly variable geometry. In addition to pointwise statistical analysis performed on the template surface, statistical conclusion regarding the accuracy of the segmentation algorithm was made for subregions and the whole ventricle with the spatial correlation of pointwise accuracy taken into account. RESULTS:Ten 3D US images were involved in this study. Pointwise local difference, ΔS, its absolute value |ΔS| as well as the standard deviations of the manual and algorithm segmentations were computed and superimposed on the each ventricle surface. Regions with lower segmentation accuracy and higher segmentation variability can be identified from these maps, and the localized information was applied to improve the accuracy of the algorithm. Intersubject average ΔS and |ΔS| as well as pooled standard deviations was computed on the template surface. Intersubject average ΔS and |ΔS| indicated that the algorithm underestimated regions in the neighborhood of the tips of anterior, inferior, and posterior horns. Intersubject pooled standard deviations indicated that manual segmentation had a higher segmentation variability than algorithm segmentation over the whole ventricle. Statistical analysis on the template surface showed that there was significant difference between algorithm and manual methods for segmenting the right lateral ventricle but not for the left lateral ventricle. CONCLUSIONS:A framework was proposed for evaluating, visualizing, and summarizing the local accuracy and variability of a segmentation algorithm. This framework can be used for improving the accuracy of segmentation algorithms, as well as providing useful feedback to improve the manual segmentation performance. More importantly, this framework can be applied for longitudinal monitoring of local ventricular changes of neonates with IVH.

journal_name

Med Phys

journal_title

Medical physics

authors

Chen Y,Qiu W,Kishimoto J,Gao Y,Chan RH,de Ribaupierre S,Fenster A,Chiu B

doi

10.1118/1.4932366

subject

Has Abstract

pub_date

2015-11-01 00:00:00

pages

6387-405

issue

11

eissn

0094-2405

issn

2473-4209

journal_volume

42

pub_type

杂志文章
  • Absolute diameter measurements of coronary arteries based on the first zero crossing of the Fourier spectrum.

    abstract::Current edge detection methods used to determine coronary artery dimensions from digital (DSA) images suffer a strong dependence on the system's modulation transfer function (MTF). The videodensitometric algorithms are less sensitive to MTF blurring, yet still result in an overestimation of the vessel size of 10% to 2...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596370

    authors: Weber DM

    更新日期:1989-03-01 00:00:00

  • The prediction of breast cancer biopsy outcomes using two CAD approaches that both emphasize an intelligible decision process.

    abstract::Mammography is the most effective method for breast cancer screening available today. However, the low positive predictive value of breast biopsy resulting from mammogram interpretation leads to approximately 70% unnecessary biopsies with benign outcomes. To reduce the high number of unnecessary breast biopsies, sever...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2786864

    authors: Elter M,Schulz-Wendtland R,Wittenberg T

    更新日期:2007-11-01 00:00:00

  • Noninvasive eye localization in ocular proton therapy through optical eye tracking: A proof of concept.

    abstract:PURPOSE:Over the last four decades, Ocular Proton Therapy has been successfully used to treat patients affected by intraocular lesions. For this, treatment geometry verification is routinely performed using radiographic images to align a configuration of fiducial radiopaque markers implanted on the sclera outer surface...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12841

    authors: Via R,Hennings F,Fattori G,Fassi A,Pica A,Lomax A,Weber DC,Baroni G,Hrbacek J

    更新日期:2018-05-01 00:00:00

  • Direct-conversion flat-panel imager with avalanche gain: feasibility investigation for HARP-AMFPI.

    abstract::The authors are investigating the concept of a direct-conversion flat-panel imager with avalanche gain for low-dose x-ray imaging. It consists of an amorphous selenium (a-Se) photoconductor partitioned into a thick drift region for x-ray-to-charge conversion and a relatively thin region called high-gain avalanche rush...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.3002314

    authors: Wronski MM,Rowlands JA

    更新日期:2008-12-01 00:00:00

  • Correcting kernel tilting and hardening in convolution/superposition dose calculations for clinical divergent and polychromatic photon beams.

    abstract::To account for clinical divergent and polychromatic photon beams, we have developed kernel tilting and kernel hardening correction methods for convolution dose calculation algorithms. The new correction methods were validated by Monte Carlo simulation. The accuracy and computation time of the our kernel tilting and ke...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597960

    authors: Liu HH,Mackie TR,McCullough EC

    更新日期:1997-11-01 00:00:00

  • Tissue-mimicking gelatin-agar gels for use in magnetic resonance imaging phantoms.

    abstract::A new variety of tissue-mimicking materials for use in 1H nuclear magnetic resonance (NMR) phantoms has been developed and extensively tested, principally at 10 MHz and at room temperature. The materials can be formed with a broad range of T1's and T2's representative of soft tissues. They are mixtures of various perc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596219

    authors: Blechinger JC,Madsen EL,Frank GR

    更新日期:1988-07-01 00:00:00

  • Differences among Monte Carlo codes in the calculations of voxel S values for radionuclide targeted therapy and analysis of their impact on absorbed dose evaluations.

    abstract::Several updated Monte Carlo (MC) codes are available to perform calculations of voxel S values for radionuclide targeted therapy. The aim of this work is to analyze the differences in the calculations obtained by different MC codes and their impact on absorbed dose evaluations performed by voxel dosimetry. Voxel S val...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3103401

    authors: Pacilio M,Lanconelli N,Lo MS,Betti M,Montani L,Torres AL,Coca PM

    更新日期:2009-05-01 00:00:00

  • A topographic leaf-sequencing algorithm for delivering intensity modulated radiation therapy.

    abstract::Topographic treatment is a radiation therapy delivery technique for fixed-gantry (nonrotational) treatments on a helical tomotherapy system. The intensity-modulated fields are created by moving the treatment couch relative to a fan-beam positioned at fixed gantry angles. The delivered dose distribution is controlled b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2216876

    authors: Desai D,Ramsey CR,Breinig M,Mahan SL

    更新日期:2006-08-01 00:00:00

  • Delivery validation of an automated modulated electron radiotherapy plan.

    abstract:PURPOSE:Modulated electron radiation therapy (MERT) represents an active area of interest that offers the potential to improve healthy tissue sparing in treatment of certain cancer cases. Challenges remain however in accurate beamlet dose calculation, plan optimization, collimation method, and delivery accuracy. In thi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4876297

    authors: Connell T,Alexander A,Papaconstadopoulos P,Serban M,Devic S,Seuntjens J

    更新日期:2014-06-01 00:00:00

  • Measurement with microscopic MRI and simulation of flow in different aneurysm models.

    abstract:PURPOSE:The impact and the development of aneurysms depend to a significant degree on the exchange of liquid between the regular vessel and the pathological extension. A better understanding of this process will lead to improved prediction capabilities. The aim of the current study was to investigate fluid-exchange in ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4929758

    authors: Edelhoff D,Walczak L,Frank F,Heil M,Schmitz I,Weichert F,Suter D

    更新日期:2015-10-01 00:00:00

  • SU-E-T-283: Carbon Ion Therapy Innovations in Dosimetry and Dose Delivery.

    abstract:OBJECTIVE:Carbon ion particle therapy delivers sharp Bragg's peaks, and hence can produce dose delivery of very high precision and conformality. To complement this characteristic, particle therapy centers implement a number of technologies unique to these centers, and are not commonly known to the medical physics commu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735351

    authors: Cernica G,Mun S

    更新日期:2012-06-01 00:00:00

  • Monte Carlo simulations on the water-to-air stopping power ratio for carbon ion dosimetry.

    abstract::Many papers discussed the I value for water given by the ICRU, concluding that a value of about 80 +/- 2 eV instead of 67.2 eV would reproduce measured ion depth-dose curves. A change in the I value for water would have an effect on the stopping power and, hence, on the water-to-air stopping power ratio, which is impo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3085877

    authors: Henkner K,Bassler N,Sobolevsky N,Jäkel O

    更新日期:2009-04-01 00:00:00

  • Four-dimensional cone-beam computed tomography and digital tomosynthesis reconstructions using respiratory signals extracted from transcutaneously inserted metal markers for liver SBRT.

    abstract:PURPOSE:Respiration-induced intrafraction target motion is a concern in liver cancer radiotherapy, especially in stereotactic body radiotherapy (SBRT), and therefore, verification of its motion is necessary. An effective means to localize the liver cancer is to insert metal fiducial markers to or near the tumor with si...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3544369

    authors: Park JC,Park SH,Kim JH,Yoon SM,Kim SS,Kim JS,Liu Z,Watkins T,Song WY

    更新日期:2011-02-01 00:00:00

  • Higher energy: is it necessary, is it worth the cost for radiation oncology?

    abstract::The physical characteristics of the interactions of megavoltage photons and electrons with matter provide distinct advantages, relative to low-energy (orthovoltage) x rays, that lead to better radiation dose distributions in patients. Use of these high-energy radiations has resulted in better patient care, which has b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596779

    authors: Das IJ,Kase KR

    更新日期:1992-07-01 00:00:00

  • Sci-Fri PM: Planning-03: Fundamental understanding of the inter-relation of arc range, angular dose rate and MLC leaf position optimization of Intensity Modulated Arc Therapy for a concave target.

    abstract::Intensity Modulated Arc Therapy (IMAT) is a rotational variant of Intensity Modulated Radiation Therapy (IMRT) that can be implemented with or without angular dose rate optimization. The purpose of this study is to determine the inter-relationship among arc range, Multi-Leaf Collimator (MLC) leaf positions and angular...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965975

    authors: Oliver M,Chen J,Wong E

    更新日期:2008-07-01 00:00:00

  • Detecting electron beam energy shifts with a commercially available energy monitor.

    abstract::Routine electron beam quality assurance requires an accurate, yet practical, method of energy characterization. Subtle shifts in beam energy may be produced by the linac bending magnet assembly, and the sensitivity of a commercially available electron beam energy-monitoring device for monitoring these small energy dri...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.599033

    authors: Evans MD,Moftah BA,Olivares M,Podgorsak EB

    更新日期:2000-07-01 00:00:00

  • Calculation of the radiological depth.

    abstract::The concept of the radiological depth is central to all algorithms which calculate radiation dose in a heterogeneous medium. For a discrete heterogeneous medium, consisting of regions of inhomogeneity, the radiological depth is usually presented as the sum over segments of the product of the segment length and the inh...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595739

    authors: Siddon RL

    更新日期:1985-01-01 00:00:00

  • Pulmonary embolism in pregnant patients: Assessing organ dose to pregnant phantom and its fetus during lung imaging.

    abstract:PURPOSE:The purpose of this study was to provide updated radiation dose from diagnostic exams performed for pregnant patients suspected of pulmonary embolism (PE) using the recently developed BREP phantoms of pregnant woman and the fetus. Also to challenge the validity of current recommendations suggest that ventilatio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12558

    authors: Rafat Motavalli L,Hoseinian Azghadi E,Miri Hakimabad H,Akhlaghi P

    更新日期:2017-11-01 00:00:00

  • The effect of coupling materials on specific absorption rate distributions at 915 MHz.

    abstract::Deionized water is commonly used to couple microwave applicators to the patient surface in the administration of local hyperthermia. Profiles of the specific absorption rate (SAR) at 1-cm depth show that deionized water coupling significantly distorts the SAR distributions of the Clini-Therm 915-MHz 10 X 10 and 15 X 1...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595881

    authors: Waterman FM,Nerlinger RE

    更新日期:1986-05-01 00:00:00

  • 2-Step IMAT and 2-Step IMRT: a geometrical approach.

    abstract::The purpose of this paper is to develop a method that reduces the number of segments for intensity modulated arc therapy (IMAT) and intensity modulated radiotherapy (IMRT) for concave target volumes (TV). The aim was to utilize no more than two intensity levels per organ at risk (OAR) and to derive both optimal segmen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1861161

    authors: Bratengeier K

    更新日期:2005-03-01 00:00:00

  • Heating patterns of microwave applicators in inhomogeneous arm and thigh phantoms.

    abstract::Heating rate (HR) patterns in cylindrical structures were studied with inhomogeneous limb phantoms. These phantoms, arm and thigh models consisting of fat, bone, and muscle material, were heated with Clini-Therm L, M, and MS applicators at 915 MHz. The thigh model is 18 cm in diameter with 2.65-cm-thick fat on the out...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596627

    authors: Chou CK,McDougall JA,Chan KW,Luk KH

    更新日期:1991-11-01 00:00:00

  • Task-based assessment of breast tomosynthesis: effect of acquisition parameters and quantum noise.

    abstract:PURPOSE:Tomosynthesis is a promising modality for breast imaging. The appearance of the tomosynthesis reconstructed image is greatly affected by the choice of acquisition and reconstruction parameters. The purpose of this study was to investigate the limitations of tomosynthesis breast imaging due to scan parameters an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3357288

    authors: Reiser I,Nishikawa RM

    更新日期:2010-04-01 00:00:00

  • An interprojection sensor fusion approach to estimate blocked projection signal in synchronized moving grid-based CBCT system.

    abstract:PURPOSE:A preobject grid can reduce and correct scatter in cone beam computed tomography (CBCT). However, half of the signal in each projection is blocked by the grid. A synchronized moving grid (SMOG) has been proposed to acquire two complimentary projections at each gantry position and merge them into one complete pr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4937934

    authors: Zhang H,Ren L,Kong V,Giles W,Zhang Y,Jin JY

    更新日期:2016-01-01 00:00:00

  • In vivo functional chronic imaging of a small animal model using optical-resolution photoacoustic microscopy.

    abstract::Optical-resolution photoacoustic microscopy (OR-PAM) has been validated as a valuable tool for label-free volumetric microvascular imaging. More importantly, the advantages of noninvasiveness and measurement consistency suggest the use of OR-PAM for chronic imaging of intact microcirculation. Here, such chronic imagin...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1118/1.3137572

    authors: Hu S,Maslov K,Wang LV

    更新日期:2009-06-01 00:00:00

  • Repeatability of SUV measurements in serial PET.

    abstract:PURPOSE:The standardized uptake value (SUV) is a quantitative measure of FDG tumor uptake frequently used as a tool to monitor therapeutic response. This study aims to (i) assess the reproducibility and uncertainty of SUV max and SUV mean, due to purely statistical, i.e., nonbiological, effects and (ii) to establish th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3578604

    authors: Schwartz J,Humm JL,Gonen M,Kalaigian H,Schoder H,Larson SM,Nehmeh SA

    更新日期:2011-05-01 00:00:00

  • Dosimetry study of Re-188 liquid balloon for intravascular brachytherapy using polymer gel dosimeters and laser-beam optical CT scanner.

    abstract::Angioplasty balloons inflated with a solution of the beta-emitter Re-188 have been used for intravascular brachytherapy to prevent restenosis. Coronary stents are in extensive clinical use for the treatment of de novo atherosclerotic stenoses. In this study, the effect of an interposed stent on the dose distribution h...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1533749

    authors: Wuu CS,Schiff P,Maryanski MJ,Liu T,Borzillary S,Weinberger J

    更新日期:2003-02-01 00:00:00

  • A scintillator-based approach to monitor secondary neutron production during proton therapy.

    abstract:PURPOSE:The primary objective of this work is to measure the secondary neutron field produced by an uncollimated proton pencil beam impinging on different tissue-equivalent phantom materials using organic scintillation detectors. Additionally, the Monte Carlo code mcnpx-PoliMi was used to simulate the detector response...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4963813

    authors: Clarke SD,Pryser E,Wieger BM,Pozzi SA,Haelg RA,Bashkirov VA,Schulte RW

    更新日期:2016-11-01 00:00:00

  • Robust experiment design for estimating myocardial beta adrenergic receptor concentration using PET.

    abstract::Myocardial beta adrenergic receptor (beta-AR) concentration can substantially decrease in congestive heart failure and significantly increase in chronic volume overload, such as in severe aortic valve regurgitation. Positron emission tomography (PET) with an appropriate ligand-receptor model can be used for noninvasiv...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2402585

    authors: Salinas C,Muzic RF Jr,Ernsberger P,Saidel GM

    更新日期:2007-01-01 00:00:00

  • Technical Note: modification of the standard gain correction algorithm to compensate for the number of used reference flat frames in detector performance studies.

    abstract:PURPOSE:The x-ray performance evaluation of digital x-ray detectors is based on the calculation of the modulation transfer function (MTF), the noise power spectrum (NPS), and the resultant detective quantum efficiency (DQE). The flat images used for the extraction of the NPS should not contain any fixed pattern noise (...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3664003

    authors: Konstantinidis AC,Olivo A,Speller RD

    更新日期:2011-12-01 00:00:00

  • Anatomical noise in contrast-enhanced digital mammography. Part I. Single-energy imaging.

    abstract:PURPOSE:The use of an intravenously injected iodinated contrast agent could help increase the sensitivity of digital mammography by adding information on tumor angiogenesis. Two approaches have been made for clinical implementation of contrast-enhanced digital mammography (CEDM), namely, single-energy (SE) and dual-ene...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4801905

    authors: Hill ML,Mainprize JG,Carton AK,Muller S,Ebrahimi M,Jong RA,Dromain C,Yaffe MJ

    更新日期:2013-05-01 00:00:00