Comparison of quantitative Y-90 SPECT and non-time-of-flight PET imaging in post-therapy radioembolization of liver cancer.

Abstract:

PURPOSE:Radioembolization with yttrium-90 microspheres may be optimized with patient-specific pretherapy treatment planning. Dose verification and validation of treatment planning methods require quantitative imaging of the post-therapy distribution of yttrium-90 (Y-90). Methods for quantitative imaging of Y-90 using both bremsstrahlung SPECT and PET have previously been described. The purpose of this study was to compare the two modalities quantitatively in humans. METHODS:Calibration correction factors for both quantitative Y-90 bremsstrahlung SPECT and a non-time-of-flight PET system without compensation for prompt coincidences were developed by imaging three phantoms. The consistency of these calibration correction factors for the different phantoms was evaluated. Post-therapy images from both modalities were obtained from 15 patients with hepatocellular carcinoma who underwent hepatic radioembolization using Y-90 glass microspheres. Quantitative SPECT and PET images were rigidly registered and the total liver activities and activity distributions estimated for each modality were compared. The activity distributions were compared using profiles, voxel-by-voxel correlation and Bland-Altman analyses, and activity-volume histograms. RESULTS:The mean ± standard deviation of difference in the total activity in the liver between the two modalities was 0% ± 9% (range -21%-18%). Voxel-by-voxel comparisons showed a good agreement in regions corresponding roughly to treated tumor and treated normal liver; the agreement was poorer in regions with low or no expected activity, where PET appeared to overestimate the activity. The correlation coefficients between intrahepatic voxel pairs for the two modalities ranged from 0.86 to 0.94. Cumulative activity volume histograms were in good agreement. CONCLUSIONS:These data indicate that, with appropriate reconstruction methods and measured calibration correction factors, either Y-90 SPECT/CT or Y-90 PET/CT can be used for quantitative post-therapy monitoring of Y-90 activity distribution following hepatic radioembolization.

journal_name

Med Phys

journal_title

Medical physics

authors

Yue J,Mauxion T,Reyes DK,Lodge MA,Hobbs RF,Rong X,Dong Y,Herman JM,Wahl RL,Geschwind JH,Frey EC

doi

10.1118/1.4962472

subject

Has Abstract

pub_date

2016-10-01 00:00:00

pages

5779

issue

10

eissn

0094-2405

issn

2473-4209

journal_volume

43

pub_type

杂志文章
  • SU-C-218-06: Evaluation of a CT-Based, Semi-Automated Lung Mass Estimation Method Under Varying Acquisition Conditions.

    abstract:PURPOSE:To evaluate a simple, semi-automated lung mass estimation method on CT scans from a variety of acquisition techniques for mass correction of MIRD dose estimates. METHODS:CT scans from ten patients undergoing stereotactic body radiation therapy treatment planning on a GE DST PET/CT scanner were analyzed retrosp...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734654

    authors: Busse N,Erwin W,Pan T

    更新日期:2012-06-01 00:00:00

  • Comparison of Gafchromic EBT2 and EBT3 films for clinical photon and proton beams.

    abstract:PURPOSE:Dose verification in highly conformal radiation therapy such as IMRT or proton therapy can benefit from the high spatial resolution offered by radio-chromic films such as Gafchromic EBT or EBT2. Recently, a new generation of these films, EBT3, has become available. The composition and thickness of the sensitive...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4737890

    authors: Reinhardt S,Hillbrand M,Wilkens JJ,Assmann W

    更新日期:2012-08-01 00:00:00

  • Proliferative diabetic retinopathy characterization based on fractal features: Evaluation on a publicly available dataset.

    abstract:PURPOSE:Diabetic retinopathy (DR) is one of the most widespread causes of preventable blindness in the world. The most dangerous stage of this condition is proliferative DR (PDR), in which the risk of vision loss is high and treatments are less effective. Fractal features of the retinal vasculature have been previously...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12627

    authors: Orlando JI,van Keer K,Barbosa Breda J,Manterola HL,Blaschko MB,Clausse A

    更新日期:2017-12-01 00:00:00

  • A framework for quantification and visualization of segmentation accuracy and variability in 3D lateral ventricle ultrasound images of preterm neonates.

    abstract:PURPOSE:Intraventricular hemorrhage (IVH) is a major cause of brain injury in preterm neonates. Three dimensional ultrasound (US) imaging systems have been developed to visualize 3D anatomical structure of preterm neonatal intracranial ventricular system with IVH and ventricular dilation. To allow quantitative analysis...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4932366

    authors: Chen Y,Qiu W,Kishimoto J,Gao Y,Chan RH,de Ribaupierre S,Fenster A,Chiu B

    更新日期:2015-11-01 00:00:00

  • Monte Carlo dosimetry for 103Pd, 125I, and 131Cs ocular brachytherapy with various plaque models using an eye phantom.

    abstract:PURPOSE:To investigate dosimetry for ocular brachytherapy for a range of eye plaque models containing(103)Pd, (125)I, or (131)Cs seeds with model-based dose calculations. METHODS:Five representative plaque models are developed based on a literature review and are compared to the standardized COMS plaque, including pla...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4864474

    authors: Lesperance M,Martinov M,Thomson RM

    更新日期:2014-03-01 00:00:00

  • SU-D-BRCD-02: A Novel Cylindrical 3D Water Scanner for Beam Data Collection: I. Validation of the Automatic-Setup.

    abstract:PURPOSE:To determine the accuracy and reproducibility of the automatic- setup procedure of a 3D water scanner (3D SCANNER, Sun Nuclear Corp). The procedure automatically aligns the scanner's coordinate system to the Linac coordinate system. A unique off-center detector holder extends the scan range to 630 mm, eliminati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734668

    authors: Li J,Lu B,Yan G,Huang Y,Liu C

    更新日期:2012-06-01 00:00:00

  • Low-dose cone-beam CT via raw counts domain low-signal correction schemes: Performance assessment and task-based parameter optimization (Part II. Task-based parameter optimization).

    abstract:PURPOSE:Different low-signal correction (LSC) methods have been shown to efficiently reduce noise streaks and noise level in CT to provide acceptable images at low-radiation dose levels. These methods usually result in CT images with highly shift-variant and anisotropic spatial resolution and noise, which makes the par...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12855

    authors: Gomez-Cardona D,Hayes JW,Zhang R,Li K,Cruz-Bastida JP,Chen GH

    更新日期:2018-05-01 00:00:00

  • Monte Carlo simulations on the water-to-air stopping power ratio for carbon ion dosimetry.

    abstract::Many papers discussed the I value for water given by the ICRU, concluding that a value of about 80 +/- 2 eV instead of 67.2 eV would reproduce measured ion depth-dose curves. A change in the I value for water would have an effect on the stopping power and, hence, on the water-to-air stopping power ratio, which is impo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3085877

    authors: Henkner K,Bassler N,Sobolevsky N,Jäkel O

    更新日期:2009-04-01 00:00:00

  • Dosimetric characterization of Ir-192 LDR elongated sources.

    abstract::Ir-192 wires have been used in low-dose-rate brachytherapy for many years. Commercially available treatment planning systems approximate the dose rate distribution of the straight or curved wires applying the superposition principle using one of the following methods: (i) The wire is modeled as a set of point sources,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2839102

    authors: van der Laarse R,Granero D,Pérez-Calatayud J,Meigooni AS,Ballester F

    更新日期:2008-03-01 00:00:00

  • WE-E-BRA-03: MR Functional Imaging to Guide Radiotherapy: Opportunities and Challenges in the Clinic.

    abstract::Human tumors are characterized by an abnormal vascular network that develops because of unregulated angiogenesis. This contributes to abnormalities of the tumor microenvironment like hypoxia, acidosis and high interstitial fluid pressure that influence treatment response and patient survival. There is an important cli...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736156

    authors: Milosevic M

    更新日期:2012-06-01 00:00:00

  • Neutron energy spectra and dose-distribution spectra of cyclotron-produced neutron beams.

    abstract::Neutron energy spectra and spectra of dose deposition in tissue-equivalent material have been measured for neutron sources produced by 16-, 22-, 35-, and 45.5-MeV deuterons and 22.5-, 35-, 45-, and 65.5-MeV protons incident upon a thick beryllium target. Neutron spectra were measured using time-of-flight techniques an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594392

    authors: Heintz PH,Johnsen SW,Peek NF

    更新日期:1977-05-01 00:00:00

  • Detection nonuniformity measurements and corrections for cone beam transmission CT on a gamma camera.

    abstract::Cone beam transmission CT (CB-CT) improves SPECT imaging by providing high-quality attenuation maps for attenuation compensation and for correlated SPECT and CT imaging. The present work measures the detection nonuniformity for CB-CT implemented with a gamma camera, and applies nonuniformity corrections to make CB-CT ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596838

    authors: Manglos SH,Capone RB,Bassano DA

    更新日期:1992-03-01 00:00:00

  • Experimental investigation on the accuracy of plastic scintillators and of the spectrum discrimination method in small photon fields.

    abstract:PURPOSE:To investigate the accuracy of output factor measurements using a commercial (Exradin W1, SI) and a prototype, "in-house" developed, plastic scintillation dosimeter (PSD) in small photon fields. METHODS:Repetitive detector-specific output factor OFdet measurements were performed in water (parallel to the CAX) ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12064

    authors: Papaconstadopoulos P,Archambault L,Seuntjens J

    更新日期:2017-02-01 00:00:00

  • DCE-MRI defined subvolumes of a brain metastatic lesion by principle component analysis and fuzzy-c-means clustering for response assessment of radiation therapy.

    abstract:PURPOSE:To develop a pharmacokinetic modelfree framework to analyze the dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) data for assessment of response of brain metastases to radiation therapy. METHODS:Twenty patients with 45 analyzable brain metastases had MRI scans prior to whole brain radiation thera...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4842556

    authors: Farjam R,Tsien CI,Lawrence TS,Cao Y

    更新日期:2014-01-01 00:00:00

  • Three dimensional intensity modulated brachytherapy (IMBT): dosimetry algorithm and inverse treatment planning.

    abstract:PURPOSE:The feasibility of intensity modulated brachytherapy (IMBT) to improve dose conformity for irregularly shaped targets has been previously investigated by researchers by means of using partially shielded sources. However, partial shielding does not fully explore the potential of IMBT. The goal of this study is t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3456598

    authors: Shi C,Guo B,Cheng CY,Esquivel C,Eng T,Papanikolaou N

    更新日期:2010-07-01 00:00:00

  • Quantitative ultrasound characterization of locally advanced breast cancer by estimation of its scatterer properties.

    abstract:PURPOSE:Tumor grading is an important part of breast cancer diagnosis and currently requires biopsy as its standard. Here, the authors investigate quantitative ultrasound parameters in locally advanced breast cancers that can potentially separate tumors from normal breast tissue and differentiate tumor grades. METHODS...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4852875

    authors: Tadayyon H,Sadeghi-Naini A,Wirtzfeld L,Wright FC,Czarnota G

    更新日期:2014-01-01 00:00:00

  • Measurement of energy dependence for XRCT radiochromic film.

    abstract::Gafchromic XRCT, radiochromic film is assessed over a broad energy range, from kilovoltage to megavoltage x rays for variations in reflected optical density to dose response. A large energy dependence was found with reflected optical density output for the same delivered dose varying from 7.8 +/- 0.35 at 25.5 keV (50 ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2219330

    authors: Butson MJ,Cheung T,Yu PK

    更新日期:2006-08-01 00:00:00

  • Iodine kinetics and dosimetry in the salivary glands during repeated courses of radioiodine therapy for thyroid cancer.

    abstract:PURPOSE:The present study was conducted to investigate salivary iodine kinetics and dosimetry during repeated courses of radioiodine ((131)I) therapy for differentiated thyroid cancer (DTC). Such data could provide a better understanding of the mechanisms of (131)I induced salivary toxicity and help to develop appropri...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3602459

    authors: Liu B,Huang R,Kuang A,Zhao Z,Zeng Y,Wang J,Tian R

    更新日期:2011-10-01 00:00:00

  • Ray-based approach to skeletal muscle perfusion measurement on interventional x-ray systems.

    abstract:PURPOSE:Periprocedural assessment of tissue perfusion by imaging methods could improve outcome control during treatment of peripheral vascular disease. Currently, endovascular revascularization treatments are assessed by planar angiography which only allows for qualitative inspection of blood flow in vessels. In this p...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3679864

    authors: Giordano M,Vonken EJ,Bertram M,Mali W,Viergever MA,Neukirchen C

    更新日期:2012-03-01 00:00:00

  • Multigroup discrete ordinates modeling of 125I 6702 seed dose distributions using a broad energy-group cross section representation.

    abstract::Our purpose in this work is to demonstrate that the efficiency of dose-rate computations in 125I brachytherapy, using multigroup discrete ordinates radiation transport simulations, can be significantly enhanced using broad energy group cross sections without a loss of accuracy. To this end, the DANTSYS multigroup disc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1429238

    authors: Daskalov GM,Baker RS,Rogers DW,Williamson JF

    更新日期:2002-02-01 00:00:00

  • System considerations in CCD-based x-ray imaging for digital chest radiography and digital mammography.

    abstract::System modeling is used to investigate the effect of various system parameters on the image quality in CCD-based x-ray imaging systems. The systems considered consist of a typical phosphor-based scintillating screen coupled to a CCD through lens or fiberoptic taper. Two applications, chest radiography and mammography,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598072

    authors: Hejazi S,Trauernicht DP

    更新日期:1997-02-01 00:00:00

  • Modification of the University of Washington Neutron Radiotherapy Facility for optimization of neutron capture enhanced fast-neutron therapy.

    abstract::A modified neutron production target assembly has been developed to provide improved performance of the proton-cyclotron-based neutron radiotherapy facility at the University of Washington for applications involving neutron capture enhanced fast-neutron therapy. The new target produces a neutron beam that yields essen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598839

    authors: Nigg DW,Wemple CA,Risler R,Hartwell JK,Harker YD,Laramore GE

    更新日期:2000-02-01 00:00:00

  • Deformable mapping technique to correlate lesions in digital breast tomosynthesis and automated breast ultrasound images.

    abstract:PURPOSE:To develop a deformable mapping technique to match corresponding lesions between digital breast tomosynthesis (DBT) and automated breast ultrasound (ABUS) images. METHODS:External fiducial markers were attached to the surface of two CIRS multi-modality compressible breast phantoms (A and B) containing multiple...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13113

    authors: Green CA,Goodsitt MM,Brock KK,Davis CL,Larson ED,Lau JH,Carson PL

    更新日期:2018-10-01 00:00:00

  • Target motion measurement without implanted markers and its validation by comparison with manually obtained data.

    abstract::For an effective radiotherapy the exact tumor location must be determined. The localization has to take into account patient's setup position as well as internal organ motion. Among the different localization methods, the use of a computer tomography (CT) scanner in the therapy room has been proposed recently. Achievi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2103447

    authors: Vences L,Wulf J,Vordermark D,Sauer O,Berlinger K,Roth M

    更新日期:2005-11-01 00:00:00

  • Registration of clinical volumes to beams-eye-view images for real-time tracking.

    abstract:PURPOSE:The authors combine the registration of 2D beam's eye view (BEV) images and 3D planning computed tomography (CT) images, with relative, markerless tumor tracking to provide automatic absolute tracking of physician defined volumes such as the gross tumor volume (GTV). METHODS:During treatment of lung SBRT cases...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4900603

    authors: Bryant JH,Rottmann J,Lewis JH,Mishra P,Keall PJ,Berbeco RI

    更新日期:2014-12-01 00:00:00

  • An artificial neural network for estimating scatter exposures in portable chest radiography.

    abstract::An adaptive linear element (Adaline) was developed to estimate the two-dimensional scatter exposure distribution in digital portable chest radiographs (DPCXR). DPCXRs and quantitative scatter exposure measurements at 64 locations throughout the chest were acquired for ten radiographically normal patients. The Adaline ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596978

    authors: Lo JY,Floyd CE Jr,Baker JA,Ravin CE

    更新日期:1993-07-01 00:00:00

  • Continuous time-dependence in computed tomography.

    abstract::Computed tomography is sensitive to changes in the imaged distribution during acquisition of the projection data. Previous investigations have emphasized discrete or discontinuous changes in the imaged object. Recent advances have motivated our investigation of object time-dependence characterized by a continuous func...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594458

    authors: Holden JE,Ip WR

    更新日期:1978-11-01 00:00:00

  • Flattening filter removal for improved image quality of megavoltage fluoroscopy.

    abstract:PURPOSE:Removal of the linear accelerator (linac) flattening filter enables a high rate of dose deposition with reduced treatment time. When used for megavoltage imaging, an unflat beam has reduced primary beam scatter resulting in sharper images. In fluoroscopic imaging mode, the unflat beam has higher photon count pe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4812678

    authors: Christensen JD,Kirichenko A,Gayou O

    更新日期:2013-08-01 00:00:00

  • Broad line quantitative chemical shift spectroscopy.

    abstract::Proton NMR spectroscopy was applied to quantitate the measurement of total body water/fat distributions in vivo. A special MR protocol was developed to excite a thick slab of tissue and display the magnitude NMR spectrum of the collected response signal. Very short echo time TE (8 ms) and long repetition time TR (4000...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596935

    authors: Sobol WT,Elster AD,Hinson WH,Chwals WJ

    更新日期:1992-01-01 00:00:00

  • Superiorization: an optimization heuristic for medical physics.

    abstract:PURPOSE:To describe and mathematically validate the superiorization methodology, which is a recently developed heuristic approach to optimization, and to discuss its applicability to medical physics problem formulations that specify the desired solution (of physically given or otherwise obtained constraints) by an opti...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4745566

    authors: Herman GT,Garduno E,Davidi R,Censor Y

    更新日期:2012-09-01 00:00:00