Abstract:
PURPOSE:To compare beam characteristics of superficial X-rays with 6 MeV Electrons for the purpose of replacing superficial treatments with electron fields for skin lesions. METHODS:Electron beam cutouts were made with 12mm thickness cerrobend in diameters 2-5 cm to match superficial X-ray machine cones. Central axis depth doses and profiles were generated using 0.007 cc Exradin A-16 ion chamber, in PTW water phantom at 1mm steps, at 96 and 100cm SSD for electron beams, and at 15cm SSD for superficial X-rays. From the beam data, radiation penumbra 90-10%, 90% profile width, peripheral dose and percentage depth dose were obtained for comparison. RESULTS:The 90-10% radiation penumbra was ranging 7.4-13.7 mm, 12.6-17.6 mm for 6 MeV electrons at 96 and 100cm SSD respectively, and 4.2-11.4 mm for 2-5 cm superficial X-ray cones. For 90% treatment width, a margin ranging 5-7 mm, 6-9 mm is needed around the periphery of target for 6 MeV Electrons at 96 and 100cm SSD respectively, and 2-3 mm for superficial X-ray cones. For 96cm SSD, the peripheral dose from the geometrical field edge were 3.9% at 1cm and 0.5% at 2cm. It was 2.6% at 1cm and 0.7% at 2cm for 100cm SSD. For superficial, it was 6.2%, 7.5%, 9.1% at 1cm, and 3.4%, 4.3%, 5.6% at 2cm for 100 kV, 120 kV and 150 kV respectively. The electron surface dose was below 90%. CONCLUSION:6 MeV Electron beam shows high superiority with rapid fall off of dose beyond target with lower peripheral dose compared to superficial X-rays. However, the electrons need higher margin around the target and also need appropriate bolus thickness to increase skin dose. The dose at depth beyond 2cm makes very significant advantage using electrons compared to superficial X-rays.
journal_name
Med Physjournal_title
Medical physicsauthors
Avadhani J,Sasidharan S,Carton C,Lowen M,Klapproth T,Licitra Cdoi
10.1118/1.4735294subject
Has Abstractpub_date
2012-06-01 00:00:00pages
3756issue
6Part13eissn
0094-2405issn
2473-4209journal_volume
39pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:In fluoroscopy-guided clinical procedures that involve tracking objects over long treatment times, there is a need for reducing the amount of imaging dose delivered to the patient and the operating staff. In this study, we introduce a feedback metric to minimize tube current while maintaining a targeting precis...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734878
更新日期:2012-06-01 00:00:00
abstract::An in vitro radiographic technique which uses saline/iodine displacement has been developed to study the thickness of bone-equivalent and soft-tissue-equivalent materials within atherosclerotic plaques in arterial specimens which have been cut open longitudinally and laid flat. Results concerning the optimization of t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597916
更新日期:1997-01-01 00:00:00
abstract::Three types of iterative algorithms, algebraic inverse treatment planning (AITP), simultaneous iterative inverse treatment planning (SIITP), and iterative least-square inverse treatment planning (ILSITP), differentiated according to their updating sequences, were generalized to three dimension with true beam geometry ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598374
更新日期:1998-10-01 00:00:00
abstract::Accurate targeting is important in intensity-modulated radiation therapy (IMRT). The positional uncertainties of structures with respect to the external beams arise in part from random organ motion and patient setup errors. While it is important to improve immobilization and reduce the influence of organ motion, the r...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.599023
更新日期:2000-07-01 00:00:00
abstract::Inverse treatment planning of intensity-modulated radiation therapy (IMRT) is complicated by several sources of error, which can cause deviations of optimized plans from the true optimal solution. These errors include the systematic and convergence error, the local minima error, and the optimizer convergence error. We...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2896070
更新日期:2008-05-01 00:00:00
abstract:PURPOSE:The authors discuss measurement methods and instrumentation useful for the characterization of the gray tracking performance of medical color monitors for diagnostic applications. The authors define gray tracking as the variability in the chromaticity of the gray levels in a color monitor. METHODS:The authors ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4953186
更新日期:2016-07-01 00:00:00
abstract::Computer algorithms for rotational therapy beams, in most cases, perform dose calculations by summing stored fixed beam data at finite angular steps. Such an algorithm, based on the Bentley beam model, was evaluated by comparing calculations with measured data for an 18-MV x-ray beam. Measurements were made in a speci...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595985
更新日期:1987-11-01 00:00:00
abstract:PURPOSE:The aim of this study was to implement a Dirichlet process mixture (DPM) model for automatic tumor edge identification on (18)F-fluorodeoxyglucose positron emission tomography ((18)F-FDG PET) images by optimizing the parameters on which the algorithm depends, to validate it experimentally, and to test its robus...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4947123
更新日期:2016-05-01 00:00:00
abstract:PURPOSE:Motion is a major confound of image quality in MRI. A method of retrospectively correcting the effects of rotations and translations on the acquired k-space data is presented. METHODS:In two phantom experiments of well-controlled translation and rotation, two MRI-compatible infrared cameras recorded motion dat...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3254189
更新日期:2009-12-01 00:00:00
abstract:PURPOSE:To evaluate the dose distribution of a 120-MeV laser-plasma accelerated electron beam which may be of potential interest for high-energy electron radiation therapy. METHODS:In the interaction between an intense laser pulse and a helium gas jet, a well collimated electron beam with very high energy is produced....
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4719962
更新日期:2012-06-01 00:00:00
abstract::Performance characteristics sufficient to provide physical data base specific to the Siemen's Stabilipan 2 orthovoltage x-ray therapy machine are presented. Operating conditions covering the working range of the unit from 100 to 300 kVp are selected. Beam quality, output, the central axis depth dose, relative output f...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596016
更新日期:1987-09-01 00:00:00
abstract:PURPOSE:To investigate how using different sets of decision criteria impacts the quality of intensity modulated radiation therapy (IMRT) plans obtained by multiobjective optimization. METHODS:A multiobjective optimization evolutionary algorithm (MOEA) was used to produce sets of IMRT plans. The MOEA consisted of two i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3589128
更新日期:2011-06-01 00:00:00
abstract::Many problems in physics involve imaging objects with high spatial frequency content in a limited amount of time. The limitation of available experimental data leads to the infamous problem of diffraction limited data which manifests itself by causing ringing in the image. This ringing is due to the interference pheno...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596427
更新日期:1989-05-01 00:00:00
abstract::This study presents experimental results about the effective depth of penetration and about the radiofrequency (rf) power absorption in humans as a function of frequency. The frequency range investigated covers 10 up to 220 MHz. For the main part, the results were derived from bench measurements of the quality factor ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595995
更新日期:1987-11-01 00:00:00
abstract:PURPOSE:The standardized uptake value (SUV) is a quantitative measure of FDG tumor uptake frequently used as a tool to monitor therapeutic response. This study aims to (i) assess the reproducibility and uncertainty of SUV max and SUV mean, due to purely statistical, i.e., nonbiological, effects and (ii) to establish th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3578604
更新日期:2011-05-01 00:00:00
abstract::Quantification of transit time of a remote after-loading high dose rate (HDR) brachytherapy source is important both for accurate treatment planning and for quality assurance checks. In this investigation, an HDR-1000 well ionization chamber and a precision electrometer are used to measure the transit time of the Ir-1...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1386779
更新日期:2001-08-01 00:00:00
abstract::A realistic photon beam model based on Monte Carlo simulation of clinical linear accelerators was implemented in a convolution/superposition dose calculation algorithm. A primary and an extra-focal sources were used in this beam model to represent the direct photons from the target and the scattered photons from other...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598111
更新日期:1997-12-01 00:00:00
abstract::An indirect flat-panel imager (FPI) with avalanche gain is being investigated for low-dose x-ray imaging. It is made by optically coupling a structured x-ray scintillator CsI(Tl) to an amorphous selenium (a-Se) avalanche photoconductor called HARP (high-gain avalanche rushing photoconductor). The final electronic imag...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2008428
更新日期:2005-09-01 00:00:00
abstract:PURPOSE:The Synchrony respiratory motion tracking of the CyberKnife system purports to provide real-time tumor motion compensation during robotic radiosurgery. Such a complex delivery system requires thorough quality assurance. In this work, RADPOS applicability as a dose and position quality assurance tool for CyberKn...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13102
更新日期:2018-07-25 00:00:00
abstract::The aim of this work was to test the suitability of a PTW diamond detector for nonreference condition dosimetry in photon beams of different energy (6 and 25 MV) and field size (from 2.6 cm x 2.6 cm to 10 cm x 10 cm). Diamond behavior was compared to that of a Scanditronix p-type silicon diode and a Scanditronix RK io...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1591431
更新日期:2003-08-01 00:00:00
abstract::An adaptive linear element (Adaline) was developed to estimate the two-dimensional scatter exposure distribution in digital portable chest radiographs (DPCXR). DPCXRs and quantitative scatter exposure measurements at 64 locations throughout the chest were acquired for ten radiographically normal patients. The Adaline ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596978
更新日期:1993-07-01 00:00:00
abstract:PURPOSE:In Stereotactic body radiation therapy (SBRT) higher dose per fraction is delivered to patients and thus the need for an accurate dose computation is further elevated. However under such conditions of small field geometries, the electronic equilibrium can be lost, making it challenging for the dose-calculation ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735539
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:To develop a method of using two-dimensional (2D) magnetic resonance thermometry, and three-dimensional (3D) Gaussian modeling to predict the volume, shape, and location of 1 day postoperative T1w high-intensity focused ultrasound lesions in medication refractory tremor patients; thereby facilitating a better c...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13868
更新日期:2019-12-01 00:00:00
abstract::A scintillation dosemeter is calibrated for 90Sr/90Y beta rays from an ophthalmic applicator, using an extrapolation ionization chamber as a reference instrument. The calibration factor for the scintillation dosemeter agrees with that given by the manufacturer of the dosemeter within ca. 2%. The estimated overall unce...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1709490
更新日期:2004-05-01 00:00:00
abstract::Secondary neutron ambient dose equivalents per the treatment absorbed dose in passive carbon-ion and proton radiotherapies were measured using a rem meter, WENDI-II at two carbon-ion radiotherapy facilities and four proton radiotherapy facilities in Japan. Our measured results showed that (1) neutron ambient dose equi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2989019
更新日期:2008-11-01 00:00:00
abstract::In this paper, the consistency of kilovoltage (tube potentials between 40 and 300 kV) x-ray beam dosimetry using the "in-air" method and the in-phantom measurement has been studied. The procedures for the measurement of the central-axis depth-dose curve, which serve as a link between the dose at the reference depth to...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598448
更新日期:1998-12-01 00:00:00
abstract::Proton beams offer several advantages over conventional radiation techniques for treating cancer and other diseases. These advantages might be negated if the leakage and scatter radiation from the beamline and patient are too large. Although the leakage and scatter radiation for the double scattering proton beamlines ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2805086
更新日期:2008-01-01 00:00:00
abstract::Noise characterization through estimation of the noise power spectrum (NPS) is a central component of the evaluation of digital x-ray systems. We begin with a brief review of the fundamentals of NPS theory and measurement, derive explicit expressions for calculation of the one- and two-dimensional (1D and 2D) NPS, and...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598623
更新日期:1999-07-01 00:00:00
abstract::Encapsulated, cylindrical sources containing 2, 5, and 8 Ci of 241Am have been designed and fabricated for intracavitary irradiation of uterine cancers. Exposure rates in air and dose rates in water around these sources have been measured using an ionization chamber and a lithium fluoride thermoluminescent dosimetry s...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596007
更新日期:1987-09-01 00:00:00
abstract:PURPOSE:Diffusion magnetic resonance imaging (MRI) in combination with functional MRI promises a whole new vista for scientists to investigate noninvasively the structural and functional connectivity of the human brain-the human connectome, which had heretofore been out of reach. As with other imaging modalities, diffu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3700166
更新日期:2012-05-01 00:00:00