A Dirichlet process mixture model for automatic (18)F-FDG PET image segmentation: Validation study on phantoms and on lung and esophageal lesions.

Abstract:

PURPOSE:The aim of this study was to implement a Dirichlet process mixture (DPM) model for automatic tumor edge identification on (18)F-fluorodeoxyglucose positron emission tomography ((18)F-FDG PET) images by optimizing the parameters on which the algorithm depends, to validate it experimentally, and to test its robustness. METHODS:The DPM model belongs to the class of the Bayesian nonparametric models and uses the Dirichlet process prior for flexible nonparametric mixture modeling, without any preliminary choice of the number of mixture components. The DPM algorithm implemented in the statistical software package R was used in this work. The contouring accuracy was evaluated on several image data sets: on an IEC phantom (spherical inserts with diameter in the range 10-37 mm) acquired by a Philips Gemini Big Bore PET-CT scanner, using 9 different target-to-background ratios (TBRs) from 2.5 to 70; on a digital phantom simulating spherical/uniform lesions and tumors, irregular in shape and activity; and on 20 clinical cases (10 lung and 10 esophageal cancer patients). The influence of the DPM parameters on contour generation was studied in two steps. In the first one, only the IEC spheres having diameters of 22 and 37 mm and a sphere of the digital phantom (41.6 mm diameter) were studied by varying the main parameters until the diameter of the spheres was obtained within 0.2% of the true value. In the second step, the results obtained for this training set were applied to the entire data set to determine DPM based volumes of all available lesions. These volumes were compared to those obtained by applying already known algorithms (Gaussian mixture model and gradient-based) and to true values, when available. RESULTS:Only one parameter was found able to significantly influence segmentation accuracy (ANOVA test). This parameter was linearly connected to the uptake variance of the tested region of interest (ROI). In the first step of the study, a calibration curve was determined to automatically generate the optimal parameter from the variance of the ROI. This "calibration curve" was then applied to contour the whole data set. The accuracy (mean discrepancy between DPM model-based contours and reference contours) of volume estimation was below (1 ± 7)% on the whole data set (1 SD). The overlap between true and automatically segmented contours, measured by the Dice similarity coefficient, was 0.93 with a SD of 0.03. CONCLUSIONS:The proposed DPM model was able to accurately reproduce known volumes of FDG concentration, with high overlap between segmented and true volumes. For all the analyzed inserts of the IEC phantom, the algorithm proved to be robust to variations in radius and in TBR. The main advantage of this algorithm was that no setting of DPM parameters was required in advance, since the proper setting of the only parameter that could significantly influence the segmentation results was automatically related to the uptake variance of the chosen ROI. Furthermore, the algorithm did not need any preliminary choice of the optimum number of classes to describe the ROIs within PET images and no assumption about the shape of the lesion and the uptake heterogeneity of the tracer was required.

journal_name

Med Phys

journal_title

Medical physics

authors

Giri MG,Cavedon C,Mazzarotto R,Ferdeghini M

doi

10.1118/1.4947123

subject

Has Abstract

pub_date

2016-05-01 00:00:00

pages

2491

issue

5

eissn

0094-2405

issn

2473-4209

journal_volume

43

pub_type

杂志文章
  • An accelerator based system for in vivo neutron activation analysis measurements of manganese in human hand bones.

    abstract::Manganese (Mn) is an essential nutrient for growth and development. Unfortunately, overexposure can lead to neurological damage, which is manifested as a movement disorder marked by tremors. Preclinical symptoms have been found in populations occupationally exposed to the element, and it is suggested that in late stag...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1517613

    authors: Arnold ML,McNeill FE,Stronach IM,Pejovic-Milic A,Chettle DR,Waker A

    更新日期:2002-11-01 00:00:00

  • Prostate brachytherapy seed localization by analysis of multiple projections: identifying and addressing the seed overlap problem.

    abstract::Intraoperative three-dimensional reconstruction of seed locations during prostate brachytherapy for purposes of immediate computation of radiation dosimetry is an active area of current investigation, including methods which use multiple fluoroscopic projections. A simulation study using seed locations extracted from ...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.1707740

    authors: Su Y,Davis BJ,Herman MG,Robb RA

    更新日期:2004-05-01 00:00:00

  • In vivo surface dosimetry with a scintillating fiber dosimeter in preclinical image-guided radiotherapy.

    abstract:PURPOSE:New preclinical image-guided irradiators and treatment planning systems represent a huge progress in radiobiology. Nevertheless, quality control of preclinical treatments is not as advanced as in clinical radiotherapy and in vivo dosimetry is less developed. In this study, we evaluate the use of a scintillating...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13903

    authors: Le Deroff C,Pérès EA,Ledoux X,Toutain J,Frelin-Labalme AM

    更新日期:2020-01-01 00:00:00

  • Evaluation of a commercial MRI Linac based Monte Carlo dose calculation algorithm with GEANT4.

    abstract:PURPOSE:This paper provides a comparison between a fast, commercial, in-patient Monte Carlo dose calculation algorithm (GPUMCD) and geant4. It also evaluates the dosimetric impact of the application of an external 1.5 T magnetic field. METHODS:A stand-alone version of the Elekta™ GPUMCD algorithm, to be used within th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4939808

    authors: Ahmad SB,Sarfehnia A,Paudel MR,Kim A,Hissoiny S,Sahgal A,Keller B

    更新日期:2016-02-01 00:00:00

  • Dual-storage phosphor proton therapy dosimetry: simultaneous quantification of dose and linear energy transfer.

    abstract:PURPOSE:To investigate the feasibility of using the high Zeff storage phosphor material BaFBrI:Eu2+ in conjunction with the low Zeff storage phosphor material KCl:Eu2+ for simultaneous proton dose and linear energy transfer (LET) measurements by 1) measuring the fundamental optical and dosimetric properties of BaFBrI:E...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14748

    authors: Setianegara J,Mazur TR,Yang D,Li HH

    更新日期:2021-02-01 00:00:00

  • Automated segmentation of anatomic regions in chest radiographs using an adaptive-sized hybrid neural network.

    abstract::The purposes of this research are to investigate the effectiveness of our novel image features for segmentation of anatomic regions such as the lungs and the mediastinum in chest radiographs and to develop an automatic computerized method for image processing. A total of 85 screening chest radiographs from Johns Hopki...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598277

    authors: Tsujii O,Freedman MT,Mun SK

    更新日期:1998-06-01 00:00:00

  • The management of imaging dose during image-guided radiotherapy: report of the AAPM Task Group 75.

    abstract::Radiographic image guidance has emerged as the new paradigm for patient positioning, target localization, and external beam alignment in radiotherapy. Although widely varied in modality and method, all radiographic guidance techniques have one thing in common--they can give a significant radiation dose to the patient....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2775667

    authors: Murphy MJ,Balter J,Balter S,BenComo JA Jr,Das IJ,Jiang SB,Ma CM,Olivera GH,Rodebaugh RF,Ruchala KJ,Shirato H,Yin FF

    更新日期:2007-10-01 00:00:00

  • On the accuracy of techniques for obtaining the calibration coefficient N(K) of 192Ir HDR brachytherapy sources.

    abstract::The accuracy of interpolation or averaging procedures for obtaining the calibration coefficient N(K) for 192Ir high-dose-rate brachytherapy sources has been investigated using the EGSnrc Monte Carlo simulation system. It is shown that the widely used two-point averaging procedure of Goetsch et al. [Med. Phys. 18, 462 ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2239198

    authors: Mainegra-Hing E,Rogers DW

    更新日期:2006-09-01 00:00:00

  • SU-E-T-178: Optically Stimulated Luminescence (OSL) Dosimetry: A Study of A-Al2O3:C Assessed by PENELOPE Monte Carlo Simulation.

    abstract:PURPOSE:To use the Monte Carlo code PENELOPE to study attenuation and tissue equivalence properties of a-Al2O3:C for OSL dosimetry. METHODS:Mass attenuation coefficients of α-Al2O3 and α-Al2O3:C with carbon percent weight concentrations from 1% to 150% were simulated with PENELOPE Monte Carlo code and compared to mass...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735237

    authors: Nicolucci P,Schuch F

    更新日期:2012-06-01 00:00:00

  • Anniversary paper: Role of medical physicists and the AAPM in improving geometric aspects of treatment accuracy and precision.

    abstract::The last 50 years have seen great advances in the accuracy of external beam radiation therapy. Geometrical uncertainties have been reduced from a centimeter or more in presimulation, skin-mark guided days to 1-2 mm in today's image-guided radiation therapy treatments. Medical physicists, with the support and guidance ...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.2836420

    authors: Yorke ED,Keall P,Verhaegen F

    更新日期:2008-03-01 00:00:00

  • Correcting kernel tilting and hardening in convolution/superposition dose calculations for clinical divergent and polychromatic photon beams.

    abstract::To account for clinical divergent and polychromatic photon beams, we have developed kernel tilting and kernel hardening correction methods for convolution dose calculation algorithms. The new correction methods were validated by Monte Carlo simulation. The accuracy and computation time of the our kernel tilting and ke...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597960

    authors: Liu HH,Mackie TR,McCullough EC

    更新日期:1997-11-01 00:00:00

  • Determination of the initial beam parameters in Monte Carlo linac simulation.

    abstract::For Monte Carlo linac simulations and patient dose calculations, it is important to accurately determine the phase space parameters of the initial electron beam incident on the target. These parameters, such as mean energy and radial intensity distribution, have traditionally been determined by matching the calculated...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2168433

    authors: Aljarrah K,Sharp GC,Neicu T,Jiang SB

    更新日期:2006-04-01 00:00:00

  • SU-E-T-635: Effect of Planning Parameters on Tomotherapy Dosimetric Quality and Treatment Efficiency.

    abstract:PURPOSE:To investigate how the setting of optimization parameters, fractional dose and tuning structure in tomotherapy treatment planning affects plan dosimetric quality and treatment efficiency. METHODS:A digital phantom to simulate head and neck radiotherapy was constructed for this study. Tumor was 10cm long C-shap...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735724

    authors: Lian J,Burkhardt K,Chera B,Chang S

    更新日期:2012-06-01 00:00:00

  • Electron disequilibrium in high-energy x-ray beams.

    abstract::The ratio between scatter dose and scatter kerma for points on the central axis of 15-MV x-ray beams has been examined by Monte Carlo calculations. This ratio, beta'S, behaves differently from that between the primary dose and kerma, beta'p. Both the primary and scatter components of beta' undergo an initial rapid bui...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597749

    authors: Hannallah D,Zhu TC,Bjärngard BE

    更新日期:1996-11-01 00:00:00

  • Effective point of measurement of thimble ion chambers in megavoltage photon beams.

    abstract:PURPOSE:Determine the effective point of measurement (EPOM) of 12 thimble ion chambers, including miniature chambers and three models widely used for clinical reference dosimetry. The EPOM is the point at which the measured dose would arise in the measurement medium in the absence of the probe: For cylindrical chambers...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3266750

    authors: Tessier F,Kawrakow I

    更新日期:2010-01-01 00:00:00

  • Low dose fraction behavior of high sensitivity radiochromic film.

    abstract::A high sensitivity (HS) model of radiochromic film is receiving increasing use. The film's linear sensitometric response in the range of 0.5-40 Gy would make this film an ideal candidate for complex dosimetry applications that require tissue equivalence. This study investigates the potential use for clinical dosimetry...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1883565

    authors: Hirata EY,Cunningham C,Micka JA,Keller H,Kissick MW,DeWerd LA

    更新日期:2005-04-01 00:00:00

  • Comparison of measured with calculated dose distribution from a 120-MeV electron beam from a laser-plasma accelerator.

    abstract:PURPOSE:To evaluate the dose distribution of a 120-MeV laser-plasma accelerated electron beam which may be of potential interest for high-energy electron radiation therapy. METHODS:In the interaction between an intense laser pulse and a helium gas jet, a well collimated electron beam with very high energy is produced....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4719962

    authors: Lundh O,Rechatin C,Faure J,Ben-Ismaïl A,Lim J,De Wagter C,De Neve W,Malka V

    更新日期:2012-06-01 00:00:00

  • Modification and benchmarking of MCNP for low-energy tungsten spectra.

    abstract::The MCNP Monte Carlo radiation transport code was modified for diagnostic medical physics applications. In particular, the modified code was thoroughly benchmarked for the production of polychromatic tungsten x-ray spectra in the 30-150 kV range. Validating the modified code for coupled electron-photon transport with ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1288397

    authors: Mercier JR,Kopp DT,McDavid WD,Dove SB,Lancaster JL,Tucker DM

    更新日期:2000-12-01 00:00:00

  • Deadtime correction for two multihead Anger cameras in 131I dual-energy-window-acquisition mode.

    abstract::Two side-by-side energy windows, one at the photopeak and one at lower energy, are sometimes employed in quantitative SPECT studies. We measured the count-rate losses at moderately high activities of 131I for two multihead Anger cameras in such a dual-window-acquisition mode by imaging a decaying source composed of tw...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598162

    authors: Koral KF,Zasadny KR,Ackermann RJ,Ficaro EP

    更新日期:1998-01-01 00:00:00

  • Technical Note: Performance comparison of ultra-high-resolution scan modes of two clinical computed tomography systems.

    abstract:PURPOSE:Two ultra-high-resolution (UHR) computed tomography (CT) scanners are clinically available. One is achieved by a CT system with a 0.25 mm × 160 row detector (Detector-UHR), whereas the other is with a 0.6 mm × 32 row detector with in-plane comb filtering in a dual source CT (Comb-UHR). We compared radiation dos...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13949

    authors: Kawashima H,Ichikawa K,Takata T,Nagata H,Hoshika M,Akagi N

    更新日期:2020-02-01 00:00:00

  • Toward consensus on quantitative assessment of medical imaging systems.

    abstract::Consensus has been developing over the past few decades on a number of measurements required for the laboratory assessment of medical imaging modalities. Nevertheless, understanding of the connection between these measurements and human observer performance in a broad range of tasks remains far from complete. Focusing...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.597511

    authors: Metz CE,Wagner RF,Doi K,Brown DG,Nishikawa RM,Myers KJ

    更新日期:1995-07-01 00:00:00

  • Errors in cerebral blood flow determinations by xenon-enhanced computed tomography due to estimation of arterial xenon concentrations.

    abstract::Errors in the determination of xenon concentrations in arterial blood during inhalation of xenon-oxygen mixtures are used to assess errors in the derivation of regional cerebral blood flow by the xenon-enhanced computed tomography (CT) method. The results of this study indicate that approximating the arterial buildup ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596051

    authors: Good WF,Gur D,Yonas H,Herron JM

    更新日期:1987-05-01 00:00:00

  • Ultrasonic Nakagami-parameter characterization of parotid-gland injury following head-and-neck radiotherapy: a feasibility study of late toxicity.

    abstract:PURPOSE:The study aims to investigate whether Nakagami parameters--estimated from the statistical distribution of the backscattered ultrasound radio-frequency (RF) signals--could provide a means for quantitative characterization of parotid-gland injury resulting from head-and-neck radiotherapy. METHODS:A preliminary c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4862507

    authors: Yang X,Tridandapani S,Beitler JJ,Yu DS,Wu N,Wang Y,Bruner DW,Curran WJ,Liu T

    更新日期:2014-02-01 00:00:00

  • SU-E-T-389: Accuracy of a VMAT Planning System for Head and Neck Radiotherapy.

    abstract:PURPOSE:To determine the accuracy of VMAT treatment planning and delivery for patients undergoing radiotherapy in the head and neck. METHOD AND MATERIALS:A dosimetric study of a typical head and neck treatment plan has been carried out using Chamber, film and TLD's placed inside an anthropomorphic phantom. Lateral and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735478

    authors: Aldaais E,Tedeschi D,Gebreamlak W,Shieder T,Alkhatib H

    更新日期:2012-06-01 00:00:00

  • Metallic nanoparticles irradiated by low-energy protons for radiation therapy: Are there significant physical effects to enhance the dose delivery?

    abstract:PURPOSE:To identify which physical properties of nanoparticles are correlated with the survival fraction of cells exposed in vitro to low-energy protons in combination with nanoparticles. METHODS:The Geant4 simulation toolkit (version 10.3) was used to model nanoparticles of different sizes (5-50 nm) and materials (Ti...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12362

    authors: Heuskin AC,Gallez B,Feron O,Martinive P,Michiels C,Lucas S

    更新日期:2017-08-01 00:00:00

  • Some possible effects of a catheter on the arterial wall.

    abstract::When a catheter is inserted through an artery, the wall shear stress increases and the secondary flow exhibits an increased number of instantaneous vortices. These effects become more evident when the annular gap between the catheter and the artery becomes more narrow. Accordingly it is suggested that these factors ma...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596448

    authors: Karahalios GT

    更新日期:1990-09-01 00:00:00

  • Simplifying volumes-of-interest (VOIs) definition in quantitative SPECT: Beyond manual definition of 3D whole-organ VOIs.

    abstract:PURPOSE:We investigated the feasibility of using simpler methods than manual whole-organ volume-of-interest (VOI) definition to estimate the organ activity concentration in single photon emission computed tomography (SPECT) in cases where the activity in the organ can be assumed to be uniformly distributed on the scale...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12164

    authors: Vicente EM,Lodge MA,Rowe SP,Wahl RL,Frey EC

    更新日期:2017-05-01 00:00:00

  • Broadband lung dielectric properties over the ablative temperature range: Experimental measurements and parametric models.

    abstract:PURPOSE:Computational models of microwave tissue ablation are widely used to guide the development of ablation devices, and are increasingly being used for the development of treatment planning and monitoring platforms. Knowledge of temperature-dependent dielectric properties of lung tissue is essential for accurate mo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13704

    authors: Sebek J,Bortel R,Prakash P

    更新日期:2019-10-01 00:00:00

  • SU-E-T-555: Weighted Four-Dimensional IMRT Planning for Dynamic MLC Tracking Using a Practical and Simple Framework.

    abstract:PURPOSE:We present a simple, practical framework for truly 4D lung IMRT planning based on a weighted individual-phase optimization paradigm. This strategy is specifically developed for use in real-time tumor tracking delivery systems so as to utilize respiratory motion as an additional degree of freedom rather than a c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735644

    authors: Tachibana H,Cheung Y,Jain S,Sawant A

    更新日期:2012-06-01 00:00:00

  • Efficient low-dose CT artifact mitigation using an artifact-matched prior scan.

    abstract:PURPOSE:Low-dose CT has attracted increasing attention due to growing concerns about radiation exposure in medical scans. However, the frugal use of x-ray radiation inevitably reduces the quality of the CT images, introducing artifacts such as noise and streaks which make the reconstructed images difficult to read in c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736528

    authors: Xu W,Mueller K

    更新日期:2012-08-01 00:00:00