SU-E-T-389: Accuracy of a VMAT Planning System for Head and Neck Radiotherapy.

Abstract:

PURPOSE:To determine the accuracy of VMAT treatment planning and delivery for patients undergoing radiotherapy in the head and neck. METHOD AND MATERIALS:A dosimetric study of a typical head and neck treatment plan has been carried out using Chamber, film and TLD's placed inside an anthropomorphic phantom. Lateral and AP port films were taken to verify the isocenter prior to treatment. Multiple treatments were performed to assess the reproducibility and uncertainty in the TLD measurements. Gafchromatic film was used between the phantom slices and then analyzed as an independent check on the TLD results. The two data sets, from TLDs and films, were then compared with the treatment planning system dose calculations. RESULTS:The measured dose to the primary planning tumor volume agrees with the planning system within 2%. The comparison of the measured dose to the secondary tumor volume ranges from 3-6% and the spinal cord comparison ranges from 3-10%. CONCLUSION:This new Smart Arc treatment, VMAT, has great benefits to the patient in that patient motion and internal motion of the tumor is dramatically reduced. Challenges arise in predicting the dose near heterogeneities between the treatment planning system and actual measurement.

journal_name

Med Phys

journal_title

Medical physics

authors

Aldaais E,Tedeschi D,Gebreamlak W,Shieder T,Alkhatib H

doi

10.1118/1.4735478

subject

Has Abstract

pub_date

2012-06-01 00:00:00

pages

3793-3794

issue

6Part16

eissn

0094-2405

issn

2473-4209

journal_volume

39

pub_type

杂志文章
  • Development and validation of a measurement-based source model for kilovoltage cone-beam CT Monte Carlo dosimetry simulations.

    abstract:PURPOSE:The purpose of this study is to adapt an equivalent source model originally developed for conventional CT Monte Carlo dose quantification to the radiation oncology context and validate its application for evaluating concomitant dose incurred by a kilovoltage (kV) cone-beam CT (CBCT) system integrated into a lin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4823795

    authors: McMillan K,McNitt-Gray M,Ruan D

    更新日期:2013-11-01 00:00:00

  • Fast reconstruction with uniform noise properties in halfscan computed tomography.

    abstract::The hybrid algorithms developed recently for the reconstruction of fan-beam images possess computational and noise properties superior to those of the fan-beam filtered backprojection (FFBP) algorithm. However, the hybrid algorithms cannot be applied directly to a halfscan fan-beam sinogram because they require knowle...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1288239

    authors: Pan X

    更新日期:2000-09-01 00:00:00

  • The use of modified single pencil beam dose kernels to improve IMRT dose calculation accuracy.

    abstract::Intensity modulated radiation therapy (IMRT) is used to deliver highly conformal radiation doses to tumors while sparing nearby sensitive tissues. Discrepancies between calculated and measured dose distributions have been reported for regions of high dose gradients corresponding to complex radiation fluence patterns. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1812851

    authors: Bergman AM,Otto K,Duzenli C

    更新日期:2004-12-01 00:00:00

  • Evaluation of volumetric modulated arc therapy for cranial radiosurgery using multiple noncoplanar arcs.

    abstract:PURPOSE:To evaluate a commercial volumetric modulated arc therapy (VMAT), using multiple noncoplanar arcs, for linac-based cranial radiosurgery, as well as evaluate the combined accuracy of the VMAT dose calculations and delivery. METHODS:Twelve patients with cranial lesions of variable size (0.1-29 cc) and two multip...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3641874

    authors: Audet C,Poffenbarger BA,Chang P,Jackson PS,Lundahl RE,Ryu SI,Ray GR

    更新日期:2011-11-01 00:00:00

  • An optimization algorithm for intensity modulated radiotherapy--the simulated dynamics with dose-volume constraints.

    abstract::We have developed a new method for optimization in intensity modulated radiation therapy (IMRT) that makes use of simulated dynamics in a classical system of interacting particles. An analogy is drawn between intensity profile optimization in IMRT and relaxation to the equilibrium configuration in a dynamic system. Th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1528179

    authors: Hou Q,Wang J,Chen Y,Galvin JM

    更新日期:2003-01-01 00:00:00

  • Electromagnetic wave propagation in a fast pulse line ion accelerator.

    abstract:PURPOSE:The pulse line ion accelerator (PLIA) is a low-cost accelerator concept originally designed to accelerate heavy ions. Our group has been investigating the use of PLIA to accelerate light ions and believe a multi-stage PLIA could be useful for short half-life PET isotope production. The goal of this work was to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13875

    authors: Behbahani RA,Diot Q,Kavanagh B,Serkova NJ,Miften M,Westerly DC

    更新日期:2019-12-01 00:00:00

  • Monte Carlo calculation of output factors for circular, rectangular, and square fields of electron accelerators (6-20 MeV).

    abstract::Monte Carlo (MC) techniques can be used to build a simulation model of an electron accelerator to calculate output factors for electron fields. This can be useful during commissioning of electron beams from a linac and in clinical practice where irregular fields are also encountered. The Monte Carlo code BEAM/EGS4 was...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1373402

    authors: Verhaegen F,Mubata C,Pettingell J,Bidmead AM,Rosenberg I,Mockridge D,Nahum AE

    更新日期:2001-06-01 00:00:00

  • Rejection and redistribution of scattered radiation in scan equalization digital radiography (SEDR): simulation with spot images.

    abstract::The anti-scatter grid has been widely used to reject scatter and increase the perceptibility of a low-contrast object in chest radiography; however, it also attenuated the primary x-rays, resulting in a substantial loss of information and an increased relative noise level in heavily attenuated regions. A more dose eff...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2739805

    authors: Liu X,Shaw CC

    更新日期:2007-07-01 00:00:00

  • SU-E-J-160: 4D Dynamic Arc of Non-Modulated Variable-Dose-Rate Fields for Lung SBRT: A Feasibility Study.

    abstract:PURPOSE:Conformal SBRT plans for Lung cancer with static gantry angles are ideal candidates for applying motion tracking because of: (1) better dosimetric conformity with reduced target margin and (2) easier and more faithful target tracking without intensity modulation. This work is to demonstrate that by delivering t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734998

    authors: Yi B,Yang X,Niu Y,Yu C

    更新日期:2012-06-01 00:00:00

  • Physical characteristics of scattered radiation in diagnostic radiology: Monte Carlo simulation studies.

    abstract::We applied Monte Carlo methods for the simulation of x-ray scattering in water phantoms. The phantom thickness was varied from 5 to 20 cm, and the monoenergetic incident x rays were varied from 15 to 100 keV. Eight screen pairs and a total absorption system were used as x-ray receptors. We determined the angular, spec...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595771

    authors: Chan HP,Doi K

    更新日期:1985-03-01 00:00:00

  • Optical image processing with liquid-crystal display for image intensifier/television systems.

    abstract::We have studied the effect of real-time optical image processing (OIP) in an image intensifier/television (II-TV) radiographic imaging system by using a liquid-crystal display (LCD) placed between the II and the TV camera. The LCD compresses the dynamic range of the transmitted image by modulating the spatial distribu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596199

    authors: Lam KL,Chan HP,Doi K

    更新日期:1988-11-01 00:00:00

  • A statistical analysis of ionometrically measured 6-MV x-ray beam parameters.

    abstract::A statistical analysis has been made of ionometrically measured parameters related to the central-axis output, the beam symmetry, the beam flatness, and the depth dose for the 6-MV x-ray beam from the Therac-6 linear accelerator. The means and coefficients of variation of the measurements are determined on a monthly b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595642

    authors: Dawson DJ,Gribble MA

    更新日期:1984-09-01 00:00:00

  • Dosimetric characterization of Ir-192 LDR elongated sources.

    abstract::Ir-192 wires have been used in low-dose-rate brachytherapy for many years. Commercially available treatment planning systems approximate the dose rate distribution of the straight or curved wires applying the superposition principle using one of the following methods: (i) The wire is modeled as a set of point sources,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2839102

    authors: van der Laarse R,Granero D,Pérez-Calatayud J,Meigooni AS,Ballester F

    更新日期:2008-03-01 00:00:00

  • Calculation of photon energy deposition kernels and electron dose point kernels in water.

    abstract::Effects of changes in the physics of EGSnrc compared to EGS4/PRESTA on energy deposition kernels for monoenergetic photons and on dose point kernels for beta sources in water are investigated. In the diagnostic energy range, Compton binding corrections were found to increase the primary energy fraction up to 4.5% at 3...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1861412

    authors: Mainegra-Hing E,Rogers DW,Kawrakow I

    更新日期:2005-03-01 00:00:00

  • Irradiation of gold nanoparticles by x-rays: Monte Carlo simulation of dose enhancements and the spatial properties of the secondary electrons production.

    abstract:PURPOSE:The aim of this study is to understand the characteristics of secondary electrons generated from the interaction of gold nanoparticles (GNPs) with x-rays as a function of nanoparticle size and beam energy and thereby further the understanding of GNP-enhanced radiotherapy. METHODS:The effective range, deflectio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3539623

    authors: Leung MK,Chow JC,Chithrani BD,Lee MJ,Oms B,Jaffray DA

    更新日期:2011-02-01 00:00:00

  • Bremsstrahlung production at 50 MeV in different target materials and configurations.

    abstract::A combination of Monte Carlo, convolution, and experimental techniques have been used to investigate bremsstrahlung production at 50 MeV in full-range targets to produce narrow elementary photon beams for scanning. Calculations using the ITS 3.0 Monte Carlo system for various target designs, including particle transpo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597681

    authors: Sätherberg A,Andreo P,Karlsson M

    更新日期:1996-04-01 00:00:00

  • Laser heating of thermoluminescent plates: application to intraoperative radiotherapy.

    abstract::A new system of radiation dose mapping based on laser heating of thermoluminescent dosimetric plates (TLDP) has been developed. Application of this technique to intraoperative radiotherapy (IORT) has been investigated. Preliminary results show that TLDP are a possible alternative to radiological films and ionization c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597725

    authors: Beteille D,Setzkom R,Prévost H,Dusseau L,Fesquet J,Gasiot J,Muraro S,Delard R,Dubois JB,Ailleres N,Missous O

    更新日期:1996-08-01 00:00:00

  • Automation of routine elements for spot-scanning proton patient-specific quality assurance.

    abstract:PURPOSE:At our institution, all proton patient plans undergo patient-specific quality assurance (PSQA) prior to treatment delivery. For intensity-modulated proton beam therapy, quality assurance is complex and time consuming, and it may involve multiple measurements per field. We reviewed our PSQA workflow and identifi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13246

    authors: Hernandez Morales D,Shan J,Liu W,Augustine KE,Bues M,Davis MJ,Fatyga M,Johnson JE,Mundy DW,Shen J,Younkin JE,Stoker JB

    更新日期:2019-01-01 00:00:00

  • Integrating prior information into microwave tomography Part 1: Impact of detail on image quality.

    abstract:PURPOSE:The authors investigate the impact that incremental increases in the level of detail of patient-specific prior information have on image quality and the convergence behavior of an inversion algorithm in the context of near-field microwave breast imaging. A methodology is presented that uses image quality measur...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12585

    authors: Kurrant D,Baran A,LoVetri J,Fear E

    更新日期:2017-12-01 00:00:00

  • Tomotherapy dose distribution verification using MAGIC-f polymer gel dosimetry.

    abstract:PURPOSE:This paper presents the application of MAGIC-f gel in a three-dimensional dose distribution measurement and its ability to accurately measure the dose distribution from a tomotherapy unit. METHODS:A prostate intensity-modulated radiation therapy (IMRT) irradiation was simulated in the gel phantom and the treat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4704496

    authors: Pavoni JF,Pike TL,Snow J,DeWerd L,Baffa O

    更新日期:2012-05-01 00:00:00

  • Designing an optical distance indicator for a radiation therapy accelerator.

    abstract::The computational aspects of the design of an optical distance indicator (ODI) for use with a radiation therapy accelerator are discussed. The specifics of the optical and mechanical design of an ODI for use with a superconducting cyclotron used for fast neutron therapy are presented. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598510

    authors: Maughan RL

    更新日期:1999-02-01 00:00:00

  • On the suitability of ultrathin detectors for absorbed dose assessment in the presence of high-density heterogeneities.

    abstract:PURPOSE:The aim of this study was to evaluate the suitability of several detectors for the determination of absorbed dose in bone. METHODS:Three types of ultrathin LiF-based thermoluminescent dosimeters (TLDs)-two LiF:Mg,Cu,P-based (MCP-Ns and TLD-2000F) and a (7)Li-enriched LiF:Mg,Ti-based (MTS-7s)-as well as EBT2 Ga...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4886760

    authors: Bueno M,Carrasco P,Jornet N,Muñoz-Montplet C,Duch MA

    更新日期:2014-08-01 00:00:00

  • Gadolinium neutron capture therapy for brain tumors: a computer study.

    abstract::A Monte Carlo computer study of the total dose distribution from neutrons and prompt gamma emissions (but excluding the contribution from conversion and Auger electrons) for gadolinium neutron capture therapy of brain tumors has been carried out in order to test the theoretic feasibility of this modality using commerc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596761

    authors: Masiakowski JT,Horton JL,Peters LJ

    更新日期:1992-09-01 00:00:00

  • SU-E-T-462: Calculation of Prescribed Dose for Permanent Implant with Cs-131 Using LQ Equation including Resensitization.

    abstract:PURPOSE:To develop a new biological equivalent dose (BED) formulism that includes repair, repopulation and resensitization (redistribution and reoxygenation), and can be used to calculate prescribed dose for permanent implant with Cs-131. METHODS:Because of lack of sufficient clinical data, the prescribed dose with ne...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735551

    authors: Luo W,Aryal P,Randall M

    更新日期:2012-06-01 00:00:00

  • GLAaS: an absolute dose calibration algorithm for an amorphous silicon portal imager. Applications to IMRT verifications.

    abstract::A new calibration algorithm (GLAaS) to derive absolute dose maps from images acquired with the Varian PV-aS500 electronic portal imager (based on amorphous silicon detectors) has been developed incorporating the dependence of detector response on primary and transmitted radiation and on field size. Detector calibratio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2218314

    authors: Nicolini G,Fogliata A,Vanetti E,Clivio A,Cozzi L

    更新日期:2006-08-01 00:00:00

  • On the assay of brachytherapy sources.

    abstract::In many of brachytherapy procedures, a large amount of radioactive sources are used to deliver desired doses to the target volume. It is both the federal regulation recommendation (U.S. Nuclear Regulatory Commission, 10 CFR 35.432) and recommendations of the American Association of Physicists in Medicine (AAPM) [Kutch...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2734723

    authors: Yue NJ,Haffty BG,Yue J

    更新日期:2007-06-01 00:00:00

  • Device-dependent activity estimation and decay correction of radionuclide mixtures with application to Tc-94m PET studies.

    abstract::Multi-instrument activity estimation and decay correction techniques were developed for radionuclide mixtures, motivated by the desire for accurate quantitation of Tc-94m positron emission tomography (PET) studies. Tc-94m and byproduct Tc isotopes were produced by proton irradiation of enriched Mo-94 and natural Mo ta...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1333411

    authors: Smith MF,Daube-Witherspoon ME,Plascjak PS,Szajek LP,Carson RE,Everett JR,Green SL,Territo PR,Balaban RS,Bacharach SL,Eckelman WC

    更新日期:2001-01-01 00:00:00

  • SU-E-T-231: Comparison of Beam Characteristics of Small Field 6 MeV Electrons as Replacement for Superficial X Ray Beam.

    abstract:PURPOSE:To compare beam characteristics of superficial X-rays with 6 MeV Electrons for the purpose of replacing superficial treatments with electron fields for skin lesions. METHODS:Electron beam cutouts were made with 12mm thickness cerrobend in diameters 2-5 cm to match superficial X-ray machine cones. Central axis ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735294

    authors: Avadhani J,Sasidharan S,Carton C,Lowen M,Klapproth T,Licitra C

    更新日期:2012-06-01 00:00:00

  • Electromagnetic guided couch and multileaf collimator tracking on a TrueBeam accelerator.

    abstract:PURPOSE:Couch and MLC tracking are two promising methods for real-time motion compensation during radiation therapy. So far, couch and MLC tracking experiments have mainly been performed by different research groups, and no direct comparison of couch and MLC tracking of volumetric modulated arc therapy (VMAT) plans has...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4946815

    authors: Hansen R,Ravkilde T,Worm ES,Toftegaard J,Grau C,Macek K,Poulsen PR

    更新日期:2016-05-01 00:00:00

  • Convolutional neural network-based pelvic floor structure segmentation using magnetic resonance imaging in pelvic organ prolapse.

    abstract:PURPOSE:Automated segmentation could improve the efficiency of modeling-based pelvic organ prolapse (POP) evaluations. However, segmentation performance is limited by the blurry soft tissue boundaries. In this study, we aimed to present a hybrid solution for uterus, rectum, bladder, and levator ani muscle segmentation ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14377

    authors: Feng F,Ashton-Miller JA,DeLancey JOL,Luo J

    更新日期:2020-09-01 00:00:00