Electromagnetic wave propagation in a fast pulse line ion accelerator.

Abstract:

PURPOSE:The pulse line ion accelerator (PLIA) is a low-cost accelerator concept originally designed to accelerate heavy ions. Our group has been investigating the use of PLIA to accelerate light ions and believe a multi-stage PLIA could be useful for short half-life PET isotope production. The goal of this work was to develop a single prototype fast PLIA structure and demonstrate electromagnetic wave propagation using a high-voltage pulser. MATERIALS AND METHODS:A 1.6 m fast PLIA structure (wave speed > 107  m/s) was constructed along with a high-voltage, sinusoidal pulse generator. The latter uses capacitive voltage doubling and spark gap switching. A step-up transformer couples voltage from the pulser to the PLIA coil. Voltage measurements on the coil were made in air using a high-voltage resistive probe, while capacitive probes placed along the length of the PLIA were used to measure wave propagation with the PLIA structure filled with transformer oil. RESULTS:Voltage measurements acquired on the primary and secondary coils of the transformer coupler in air demonstrated a peak-to-peak voltage step-up of 4.2 relative to the pulser DC charging voltage. The maximum voltage time-rate-of-change on the PLIA coil was 0.76 × 1013  V/s. Capacitive probe measurements indicated voltage oscillations on the PLIA coil with half-period equal to 43 ± 0.9 ns and wave speed (with oil) of 1.2 × 107  m/s. Average and peak accelerating gradients were conservatively estimated to be 0.44 and 0.60 MV/m, respectively, with a charging voltage of 55 kV. Wave propagation was demonstrated at these gradients without flashover at a vacuum pressure of 9 × 10-6  Torr. Submerging the pulser in oil would allow for charging voltages up to 150 kV and produce accelerating gradients >1.2 MV/m. CONCLUSIONS:Use of a multi-stage, fast PLIA for light ion acceleration could provide a low-cost complement to cyclotrons for the production of short half-life isotopes used for PET imaging, including carbon-11, nitrogen-13, oxygen-15, and fluorine-18.

journal_name

Med Phys

journal_title

Medical physics

authors

Behbahani RA,Diot Q,Kavanagh B,Serkova NJ,Miften M,Westerly DC

doi

10.1002/mp.13875

subject

Has Abstract

pub_date

2019-12-01 00:00:00

pages

5714-5721

issue

12

eissn

0094-2405

issn

2473-4209

journal_volume

46

pub_type

杂志文章
  • Lung dosimetry in a linac-MRI radiotherapy unit with a longitudinal magnetic field.

    abstract:PURPOSE:There is interest in developing linac-MR systems for MRI-guided radiation therapy. To date, the designs for such linac-MR devices have been restricted to a transverse geometry where the static magnetic field is oriented perpendicular to the direction of the incident photon beam. This work extends possibilities ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3475942

    authors: Kirkby C,Murray B,Rathee S,Fallone BG

    更新日期:2010-09-01 00:00:00

  • An optimization algorithm for intensity modulated radiotherapy--the simulated dynamics with dose-volume constraints.

    abstract::We have developed a new method for optimization in intensity modulated radiation therapy (IMRT) that makes use of simulated dynamics in a classical system of interacting particles. An analogy is drawn between intensity profile optimization in IMRT and relaxation to the equilibrium configuration in a dynamic system. Th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1528179

    authors: Hou Q,Wang J,Chen Y,Galvin JM

    更新日期:2003-01-01 00:00:00

  • Energy spectra due to the intrinsic radiation of LYSO/LSO scintillators for a wide range of crystal sizes.

    abstract::Most detectors in current positron emission tomography (PET) scanners and prototypes use lutetium oxyorthosilicate (LSO) or lutetium yttrium oxyorthosilicate (LYSO) scintillators. The aim of this work is to provide a complete set of background energy spectra, due to the scintillator intrinsic radioactivity, for a wide...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14729

    authors: Domínguez-Jiménez DY,Alva-Sánchez H

    更新日期:2021-01-21 00:00:00

  • Reference standard and statistical model for intersite and temporal comparisons of CT attenuation in a multicenter quantitative lung study.

    abstract:PURPOSE:The purpose of this study was to detect and analyze anomalies between a large number of computed tomography (CT) scanners, tracked over time, utilized to collect human pulmonary CT data for a national multicenter study: chronic obstructive pulmonary disease genetic epidemiology study (COPDGene). METHODS:A cust...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1118/1.4747342

    authors: Sieren JP,Newell JD,Judy PF,Lynch DA,Chan KS,Guo J,Hoffman EA

    更新日期:2012-09-01 00:00:00

  • Regularization strategies in statistical image reconstruction of low-dose x-ray CT: A review.

    abstract::Statistical image reconstruction (SIR) methods have shown potential to substantially improve the image quality of low-dose x-ray computed tomography (CT) as compared to the conventional filtered back-projection (FBP) method. According to the maximum a posteriori (MAP) estimation, the SIR methods are typically formulat...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1002/mp.13123

    authors: Zhang H,Wang J,Zeng D,Tao X,Ma J

    更新日期:2018-10-01 00:00:00

  • Effect of the first day correction on systematic setup error reduction.

    abstract::Treatment simulation is usually performed with a conventional simulator using kV X-rays or with a computed tomography (CT) simulator before the treatment course begins. The purpose is to verify patient setup under the same conditions as for treatment planning. Systematic (preparation) setup errors can be introduced by...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2727299

    authors: Wu Q,Lockman D,Wong J,Yan D

    更新日期:2007-05-01 00:00:00

  • Effects of constant frequency noise in magnetic resonance imaging with nonuniform k-space sampling.

    abstract::Magnetic resonance images can be compromised by constant frequency (CF) noise, such as radio frequency (RF) noise. We investigate the effects of CF noise in four imaging methods with non-uniform k-space sampling: single-shot echo-planar imaging (EPI) with sinusoidal readout gradients, phase-encoded echo-planar spectro...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1496096

    authors: Du W,Karczmar GS,Pan X

    更新日期:2002-08-01 00:00:00

  • A comparison of gantry-mounted x-ray-based real-time target tracking methods.

    abstract:PURPOSE:Most modern radiotherapy machines are built with a 2D kV imaging system. Combining this imaging system with a 2D-3D inference method would allow for a ready-made option for real-time 3D tumor tracking. This work investigates and compares the accuracy of four existing 2D-3D inference methods using both motion tr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12765

    authors: Montanaro T,Nguyen DT,Keall PJ,Booth J,Caillet V,Eade T,Haddad C,Shieh CC

    更新日期:2018-03-01 00:00:00

  • Subvoxel precise skeletons of volumetric data based on fast marching methods.

    abstract::The accurate calculation of the skeleton of an object is a problem not satisfactorily solved by existing approaches. Most algorithms require a significant amount of user interaction and use a voxel grid to compute discrete and often coarse approximations of this representation of the data. We present a novel, automati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2409238

    authors: Van Uitert R,Bitter I

    更新日期:2007-02-01 00:00:00

  • Liquid ionization chambers for absorbed dose measurements in water at low dose rates and intermediate photon energies.

    abstract::Two new liquid ionization chamber (LIC) designs, consisting of cylindrical and plane-parallel configurations, are presented. They are designed to be suitable for high-precision measurements of absorbed dose-to-water at dose rates and photon energies typical for LDR intermediate photon energy brachytherapy sources. The...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598268

    authors: Wickman G,Johansson B,Bahar-Gogani J,Holmström T,Grindborg JE

    更新日期:1998-06-01 00:00:00

  • Image-based iterative compensation of motion artifacts in computed tomography.

    abstract:PURPOSE:This article presents an iterative method for compensation of motion artifacts for slowly rotating computed tomography (CT) systems. Patient's motion introduces inconsistencies among projections and yields severe reconstruction artifacts for free-breathing acquisitions. Streaks and doubling of structures can ap...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3244035

    authors: Schretter C,Rose G,Bertram M

    更新日期:2009-11-01 00:00:00

  • SU-E-I-16: Automated Liver Segmentation Method for CBCT Dataset by Probabilistic Atlas Construction.

    abstract:PURPOSE:The aiming is getting accurate liver contour structures automatically for following adaptive radiation therapy in daily CBCT images which is very low-contrast comparing the planning CT. METHODS:Probabilistic atlas is constructed by 50 intravenous contrast planning CT images by iterative affine registration pro...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734730

    authors: Li D,Li H,Yin Y,Chen J

    更新日期:2012-06-01 00:00:00

  • Improved quantification of radionuclide uptake using deconvolution and windowed subtraction techniques for scatter compensation in single photon emission computed tomography.

    abstract::A comparison of two methods of scatter compensation in single photon emission computed tomography (SPECT) imaging is made on the basis of improvements in quantification. The methods, scatter-window subtraction and constrained deconvolution of an average point source response function (PSRF), are described; the theoret...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596453

    authors: Yanch JC,Flower MA,Webb S

    更新日期:1990-11-01 00:00:00

  • Position detection accuracy of a novel linac-mounted intrafractional x-ray imaging system.

    abstract:PURPOSE:The authors have developed a system that monitors intrafractional target motion perpendicular to the treatment beam with the aid of radioopaque markers by means of separating kV image and megavoltage (MV) treatment field on a single flat-panel detector. METHODS:They equipped a research Siemens Artiste linear a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3665712

    authors: Fast MF,Krauss A,Oelfke U,Nill S

    更新日期:2012-01-01 00:00:00

  • Evaluation of the accuracy of fetal dose estimates using TG-36 data.

    abstract::The American Association of Physicists in Medicine Radiation Therapy Committee Task Group 36 report (TG-36) provides guidelines for managing radiation therapy of pregnant patients. Included in the report are data that can be used to estimate the dose to the fetus. The purpose of this study is to evaluate the accuracy ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2710332

    authors: Kry SF,Starkschall G,Antolak JA,Salehpour M

    更新日期:2007-04-01 00:00:00

  • Modeling acute and chronic hypoxia using serial images of 18F-FMISO PET.

    abstract:PURPOSE:Two types of tumor hypoxia most likely exist in human cancers: Chronic hypoxia due to the paucity of blood capillaries and acute hypoxia due to temporary shutdoWn of microvasculatures or fluctuation in the red cell flux. In a recent hypoxia imaging study using 18F-FMISO PET, the authors observed variation in tr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3213092

    authors: Wang K,Yorke E,Nehmeh SA,Humm JL,Ling CC

    更新日期:2009-10-01 00:00:00

  • Development of an automated region of interest selection method for 3D surface monitoring of head motion.

    abstract:PURPOSE:To simplify the often complex and user-dependent manual region of interest (ROI) selection process for head motion monitoring, an automatic ROI selection method was developed. METHODS:The automatic ROI selection algorithm calculated the displacements and velocities of 3D surface points between a temporally cor...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4711805

    authors: Kang HJ,Grelewicz Z,Wiersma RD

    更新日期:2012-06-01 00:00:00

  • WE-G-211-02: Origins and Development of Magnetic Resonance Imaging.

    abstract::The method of magnetic resonance imaging (MRI) was an extension of nuclear magnetic resonance (NMR) spectroscopy that was enabled by computational systems capable of performing the Fast Fourier Transform. Initially, a diverse group of methods were proposed for producing images with NMR, with the multi-slice spin-warp ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736176

    authors: Clarke G

    更新日期:2012-06-01 00:00:00

  • Assessment of the spectral performance of hybrid photon counting x-ray detectors.

    abstract:PURPOSE:Hybrid Photon Counting (HPC) detectors profoundly improved x-ray diffraction experiments at third generation synchrotron facilities. Enabling the simultaneous measurement of x-ray intensities in multiple energy bins, they also have many potential applications in the field of medical imaging. A prerequisite for ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12323

    authors: Trueb P,Zambon P,Broennimann C

    更新日期:2017-09-01 00:00:00

  • Feasibility of MRI-only treatment planning for proton therapy in brain and prostate cancers: Dose calculation accuracy in substitute CT images.

    abstract:PURPOSE:Magnetic resonance imaging (MRI) is increasingly used for radiotherapy target delineation, image guidance, and treatment response monitoring. Recent studies have shown that an entire external x-ray radiotherapy treatment planning (RTP) workflow for brain tumor or prostate cancer patients based only on MRI refer...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4958677

    authors: Koivula L,Wee L,Korhonen J

    更新日期:2016-08-01 00:00:00

  • Four-dimensional cone-beam computed tomography and digital tomosynthesis reconstructions using respiratory signals extracted from transcutaneously inserted metal markers for liver SBRT.

    abstract:PURPOSE:Respiration-induced intrafraction target motion is a concern in liver cancer radiotherapy, especially in stereotactic body radiotherapy (SBRT), and therefore, verification of its motion is necessary. An effective means to localize the liver cancer is to insert metal fiducial markers to or near the tumor with si...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3544369

    authors: Park JC,Park SH,Kim JH,Yoon SM,Kim SS,Kim JS,Liu Z,Watkins T,Song WY

    更新日期:2011-02-01 00:00:00

  • Iodine quantification in limited angle tomography.

    abstract:PURPOSE:To develop and test the feasibility of a two-pass iterative reconstruction algorithm with material decomposition designed to obtain quantitative iodine measurements in digital breast tomosynthesis. METHODS:Contrast-enhanced mammography has shown promise as a cost-effective alternative to magnetic resonance ima...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14400

    authors: Michielsen K,Rodríguez-Ruiz A,Reiser I,Nagy JG,Sechopoulos I

    更新日期:2020-10-01 00:00:00

  • Iterative algebraic reconstruction algorithms for emission computed tomography: a unified framework and its application to positron emission tomography.

    abstract::In this paper, a unified framework of iterative algebraic reconstruction for emission computed tomography (ECT) and its application to positron emission tomography (PET) is presented. The unified framework is based on an algebraic image restoration model and contains conventional iterative algebraic reconstruction alg...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596954

    authors: Xu XL,Liow JS,Strother SC

    更新日期:1993-11-01 00:00:00

  • Multiscale entropy of laser Doppler flowmetry signals in healthy human subjects.

    abstract:PURPOSE:The cardiovascular system (CVS) regulation can be studied from a central viewpoint, through heart rate variability (HRV) data, and from a peripheral viewpoint, through laser Doppler flowmetry (LDF) signals. Both the central and peripheral CVSs are regulated by several interacting mechanisms, each having its own...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3512796

    authors: Humeau A,Buard B,Mahé G,Rousseau D,Chapeau-Blondeau F,Abraham P

    更新日期:2010-12-01 00:00:00

  • Technical Note: Noninvasive mid-IR fiber-optic evanescent wave spectroscopy (FEWS) for early detection of skin cancers.

    abstract:PURPOSE:Melanoma is the most lethal of the three primary skin cancers, including also basal cell carcinoma (BCC) and squamous cell carcinoma (SCC), which are less lethal. The accepted diagnosis process involves manually observing a suspicious lesion through a Dermascope (i.e., a magnifying glass), followed by a biopsy....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14471

    authors: Basov S,Dankner Y,Weinstein M,Katzir A,Platkov M

    更新日期:2020-11-01 00:00:00

  • Simplified skipped phase encoding and edge deghosting (SPEED) for imaging sparse objects with applications to MRA.

    abstract::The fast imaging method named skipped phase encoding and edge deghosting (SPEED) has been demonstrated to reduce scan time considerably with typical magnetic resonance imaging data. In this work, SPEED is simplified with improved efficiency to accelerate the scan of sparse objects; we refer to this method as S-SPEED. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2750966

    authors: Chang Z,Xiang QS

    更新日期:2007-08-01 00:00:00

  • Noise, sampling, and the number of projections in cone-beam CT with a flat-panel detector.

    abstract:PURPOSE:To investigate the effect of the number of projection views on image noise in cone-beam CT (CBCT) with a flat-panel detector. METHODS:This fairly fundamental consideration in CBCT system design and operation was addressed experimentally (using a phantom presenting a uniform medium as well as statistically moti...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4875688

    authors: Zhao Z,Gang GJ,Siewerdsen JH

    更新日期:2014-06-01 00:00:00

  • Effect of surrounding vasculature on intravoxel BOLD signal.

    abstract:PURPOSE:The nonlocal influence from distant magnetization will affect the magnetic field at a voxel in question. Existing reports on BOLD simulation only consider vasculature inside a single voxel, thus omitting the contribution from the surrounding regions. In this article, the authors study the effect of the surround...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3366251

    authors: Chen Z,Caprihan A,Calhoun V

    更新日期:2010-04-01 00:00:00

  • Analytical considerations of beam hardening in medical accelerator photon spectra.

    abstract::Beam hardening is a well-known phenomenon for therapeutic accelerator beams passing through matter in narrow beam geometry. This study assesses quantitatively the magnitude of beam hardening of therapeutic beams in water. A formal concept of beam hardening is proposed which is based on the decrease of the mean attenua...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598704

    authors: Kleinschmidt C

    更新日期:1999-09-01 00:00:00

  • Predicting high-intensity focused ultrasound thalamotomy lesions using 2D magnetic resonance thermometry and 3D Gaussian modeling.

    abstract:PURPOSE:To develop a method of using two-dimensional (2D) magnetic resonance thermometry, and three-dimensional (3D) Gaussian modeling to predict the volume, shape, and location of 1 day postoperative T1w high-intensity focused ultrasound lesions in medication refractory tremor patients; thereby facilitating a better c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13868

    authors: Seasons GM,Mazerolle EL,Sankar T,Martino D,Kiss ZHT,Pichardo S,Pike GB

    更新日期:2019-12-01 00:00:00