Abstract:
:Treatment simulation is usually performed with a conventional simulator using kV X-rays or with a computed tomography (CT) simulator before the treatment course begins. The purpose is to verify patient setup under the same conditions as for treatment planning. Systematic (preparation) setup errors can be introduced by this process. The purpose of this study is to characterize the setup errors using electronic portal image (EPI) analyses and to propose a method to reduce the systematic component by performing simulation and patient preparation on the treatment machine. In this study, the first four or five days EPIs were analyzed from a total of 533 prostate cancer patients who were simulated on conventional simulators. We characterized setup errors using four parameters: {M(microi), Sigma (microi), RMS(microi), sigma (sigmai)}, where microi and sigmai are individual patient mean and standard deviation, M, Sigma, and RMS are the mean, standard deviation, and root-mean-square of underlying variables (microi and sigmai). We have performed a simulation of removing systematic components by correcting the first day setup error. As a comparison, we also carried out a similar analyses for patients simulated on a CT simulator and patients treated on a linac with an on-board kV CT imaging system, although a limited number of patients were available in these two samples. We found that Sigma (/ui)=(2.6,3.4,2.4) mm, and RMS(sigmai)=(1.5,1.9,1.0) mm in lateral, anterior/posterior, and cranial/caudal directions, indicating that systematic errors are much larger than random errors. Strong correlations were found between measurement on the first day and microi, implying the first day's measurement is a good predictor for microi. The same parameters were also computed for days 2-4, with and without the first day correction. Without correction, M(microi)2-4=(0.7,1.6,-1.0) mm, and Sigma(microi)2-4=(2.6,3.5,2.4) mm. With correction, M(microi)2-4=(0.0,0.4,0.4) mm, much closer to zero, and Sigma(microi)2-4=(1.8,2.2, 1.2) mm, also much smaller. While the use of a CT simulator can reduce the systematic errors, the benefits of first day correction can still be observed, although at a smaller magnitude. Therefore, the systematic setup error can be significantly reduced if the patient is marked and fields are verified on the treatment machine on the first fraction, preferably with an on-board kV imaging system.
journal_name
Med Physjournal_title
Medical physicsauthors
Wu Q,Lockman D,Wong J,Yan Ddoi
10.1118/1.2727299subject
Has Abstractpub_date
2007-05-01 00:00:00pages
1789-96issue
5eissn
0094-2405issn
2473-4209journal_volume
34pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:Concurrent irradiation of the prostate and pelvic lymph nodes is technically challenging due to treating one moving target and one immobile target. The purposes of this article are to propose a new management strategy and to compare this strategy to the conventional isocenter shift method and the previously pro...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3480505
更新日期:2010-09-01 00:00:00
abstract::Many problems in physics involve imaging objects with high spatial frequency content in a limited amount of time. The limitation of available experimental data leads to the infamous problem of diffraction limited data which manifests itself by causing ringing in the image. This ringing is due to the interference pheno...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596427
更新日期:1989-05-01 00:00:00
abstract:PURPOSE:The liver segments divided by Couinaud classification method are used to understand the functional anatomy of liver, which is significant in hepatic resection surgery. In Couinaud classification method, each third-order branch of the portal vein (PV) defines the supplied territory of a corresponding liver segme...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14745
更新日期:2021-02-02 00:00:00
abstract::This study proposes an algorithm for selecting beam weight, wedge angle, and wedge orientation for three-dimensional radiation therapy treatment planning. According to dose gradient analysis, the necessary and sufficient condition for achieving a homogeneous dose over the target volume is that the total vector sum of ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1286591
更新日期:2000-08-01 00:00:00
abstract::Secondary neutron ambient dose equivalents per the treatment absorbed dose in passive carbon-ion and proton radiotherapies were measured using a rem meter, WENDI-II at two carbon-ion radiotherapy facilities and four proton radiotherapy facilities in Japan. Our measured results showed that (1) neutron ambient dose equi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2989019
更新日期:2008-11-01 00:00:00
abstract::Gafchromic XRCT, radiochromic film is assessed over a broad energy range, from kilovoltage to megavoltage x rays for variations in reflected optical density to dose response. A large energy dependence was found with reflected optical density output for the same delivered dose varying from 7.8 +/- 0.35 at 25.5 keV (50 ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2219330
更新日期:2006-08-01 00:00:00
abstract::In previous work it has been shown that a standard backpropagation neural network can be trained to reconstruct sections of single photon emission computed tomography (SPECT) images based on the planar image projections as inputs. In this study, it is demonstrated that an artificial neural network (ANN) trained on a s...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597586
更新日期:1995-05-01 00:00:00
abstract:PURPOSE:The purpose of this study was to evaluate the effect of various computed tomography (CT) thresholds on trapping volumetric measurements by multidetector CT in chronic obstructive pulmonary disease (COPD). METHODS:Twenty-three COPD patients were scanned with a 64-slice CT scanner in both the inspiratory and exp...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4813906
更新日期:2013-08-01 00:00:00
abstract::Encapsulated, cylindrical sources containing 2, 5, and 8 Ci of 241Am have been designed and fabricated for intracavitary irradiation of uterine cancers. Exposure rates in air and dose rates in water around these sources have been measured using an ionization chamber and a lithium fluoride thermoluminescent dosimetry s...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596007
更新日期:1987-09-01 00:00:00
abstract:PURPOSE:To provide a fast computational method, based on the proximal graph solver (POGS) - A convex optimization solver using the alternating direction method of multipliers (ADMM), for calculating an optimal treatment plan in rotating shield brachytherapy (RSBT). RSBT treatment planning has more degrees of freedom th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12486
更新日期:2017-10-01 00:00:00
abstract::Respiratory motion can produce misregistration errors between CT and PET images in cardiac PET/CT imaging. The objective of this study was to determine if manual registration of a single-phase end-expiration CT scan to the PET image would eliminate respiratory-induced artifacts. Listmode data from 71 cardiac PET patie...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2965988
更新日期:2008-07-01 00:00:00
abstract:PURPOSE:Helical tomotherapy is a complex delivery technique, integrating CT image guidance and intensity modulated radiotherapy in a single system. The integration of the CT detector ring on the gantry not only allows patient position verification but is also often used to perform various QA procedures. This convenienc...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3566067
更新日期:2011-04-01 00:00:00
abstract::Conventional IMRT dose verification using film and ion chamber measurements is useful but limited with respect to the actual dose distribution received by the patient. The Monte Carlo simulation has been introduced as an independent dose verification tool for IMRT using the patient CT data and MLC leaf sequence files,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2208916
更新日期:2006-07-01 00:00:00
abstract::Dose uniformity throughout the treatment volume is essential to precision radiation therapy. Tissue compensators are often used as a means to eliminate dose nonuniformity resulting from surface contour irregularities. This paper evaluates the accuracy of using an effective attenuation coefficient for calculating the t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596561
更新日期:1990-01-01 00:00:00
abstract::In this study we address the problem of predicting the position of a moving lung tumor during respiration on the basis of external breathing signals--a technique used for beam gating, tracking, and other dynamic motion management techniques in radiation therapy. We demonstrate the use of neural network filters to corr...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2134958
更新日期:2005-12-01 00:00:00
abstract:PURPOSE:To evaluate plan quality of a novel MRI-compatible direction modulated brachytherapy (DMBT) tandem applicator using 192 Ir, 60 Co, and 169 Yb HDR brachytherapy sources, for various cervical cancer high-risk clinical target volumes (CTVHR ). MATERIALS AND METHODS:The novel DMBT tandem applicator has six periphe...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12598
更新日期:2017-12-01 00:00:00
abstract::The ability to control thermal drifts is essential in operating a calorimeter. We investigated a thermal enclosure, which envelops the calorimeter with temperature-regulated air, thus thermally isolating the calorimeter from the room. The desired temperature in the enclosure is controlled by a control circuit and a th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595760
更新日期:1985-05-01 00:00:00
abstract::A restricted angular scattering model for electron penetration in dense media is presented. In the model, the Fermi-Eyges transport equation is modified through the addition of an extra term which may be interpreted as representing an apparent force opposing the scattering of electrons into wider angles. The introduct...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596747
更新日期:1991-01-01 00:00:00
abstract:PURPOSE:Different approaches have been used in dynamic elastography to assess mechanical properties of biological tissues. Most techniques are based on a simple inversion based on the measurement of the shear wave speed to assess elasticity, whereas some recent strategies use more elaborated analytical or finite elemen...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4942813
更新日期:2016-04-01 00:00:00
abstract:PURPOSE:Our aim was to compare different magnet arrangements for magnetic cell delivery to human lower leg arteries and investigate the theoretical targeting efficiency under realistic flow conditions as a possible treatment after angioplasty. Additionally the potential of scaling down or translating the magnetic actua...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3593363
更新日期:2011-07-01 00:00:00
abstract::The accuracy of interpolation or averaging procedures for obtaining the calibration coefficient N(K) for 192Ir high-dose-rate brachytherapy sources has been investigated using the EGSnrc Monte Carlo simulation system. It is shown that the widely used two-point averaging procedure of Goetsch et al. [Med. Phys. 18, 462 ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2239198
更新日期:2006-09-01 00:00:00
abstract:PURPOSE:CT reconstruction algorithms implemented on the GPU are highly sensitive to their implementation details and the hardware they run on. Fine-tuning an implementation for optimal performance can be a time consuming task and require many updates when the hardware changes. There are some techniques that do automati...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4773045
更新日期:2013-03-01 00:00:00
abstract::In this paper, the authors review the field of resolution modeling in positron emission tomography (PET) image reconstruction, also referred to as point-spread-function modeling. The review includes theoretical analysis of the resolution modeling framework as well as an overview of various approaches in the literature...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.4800806
更新日期:2013-06-01 00:00:00
abstract::Segmentation of the lungs within magnetic resonance (MR) scans is a necessary step in the computer-based analysis of thoracic MR images. This process is often confounded by image acquisition artifacts and disease-induced morphological deformation. We have developed an automated method for lung segmentation that is ins...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2214165
更新日期:2006-09-01 00:00:00
abstract:PURPOSE:Adding magnetic resonance (MR)-derived information to standard transrectal ultrasound (TRUS) images for guiding prostate biopsy is of substantial clinical interest. A tumor visible on MR images can be projected on ultrasound (US) by using MR-US registration. A common approach is to use surface-based registratio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4917481
更新日期:2015-05-01 00:00:00
abstract:PURPOSE:The aim of this study is to understand the characteristics of secondary electrons generated from the interaction of gold nanoparticles (GNPs) with x-rays as a function of nanoparticle size and beam energy and thereby further the understanding of GNP-enhanced radiotherapy. METHODS:The effective range, deflectio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3539623
更新日期:2011-02-01 00:00:00
abstract::Direct comparisons of the National Institute of Standards and Technology's (NIST) Ritz 20 kV to 100 kV standard free-air ionization chamber and a portable variable-length free-air ionization chamber designed by the University of Wisconsin-Madison Accredited Dosimetry Calibration Laboratory (UW-ADCL) were made on NISTs...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598148
更新日期:1997-08-01 00:00:00
abstract:PURPOSE:To identify which physical properties of nanoparticles are correlated with the survival fraction of cells exposed in vitro to low-energy protons in combination with nanoparticles. METHODS:The Geant4 simulation toolkit (version 10.3) was used to model nanoparticles of different sizes (5-50 nm) and materials (Ti...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12362
更新日期:2017-08-01 00:00:00
abstract::The Monte Carlo (MC) method has been shown through many research studies to calculate accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient tissues where the effects of electron transport cannot be accurately handled with conventional, deterministic dose algorithms. Despite its p...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.2795842
更新日期:2007-12-01 00:00:00
abstract::Traditionally, short scan helical FDK algorithms have been implemented based on horizontal transaxial slices. However, not every point on the horizontal transaxial slice satisfies Tuy's condition for the corresponding (pi+fan angle) segment of helix, which means that some points on the horizontal slices are incomplete...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1916077
更新日期:2005-06-01 00:00:00