Comparison of exposure standards in the mammography x-ray region.

Abstract:

:Direct comparisons of the National Institute of Standards and Technology's (NIST) Ritz 20 kV to 100 kV standard free-air ionization chamber and a portable variable-length free-air ionization chamber designed by the University of Wisconsin-Madison Accredited Dosimetry Calibration Laboratory (UW-ADCL) were made on NISTs low-energy tungsten x-ray range. As a result of this direct comparison, NIST has established a UW-ADCL designed chamber, the Attix chamber, as the national standard chamber for the mammography energy x-ray range. The Ritz standard chamber and the Attix standard chamber have been extensively compared using the new molybdenum and rhodium beam qualities. The results indicate that exposure measurements in the mammography energy x-ray region with the two free-air chambers can be made with a discrepancy of less than 0.35%.

journal_name

Med Phys

journal_title

Medical physics

authors

Coletti JG,Pearson DW,DeWerd LA,O'Brien CM,Lamperti PJ

doi

10.1118/1.598148

subject

Has Abstract

pub_date

1997-08-01 00:00:00

pages

1263-7

issue

8

eissn

0094-2405

issn

2473-4209

journal_volume

24

pub_type

杂志文章
  • Performance evaluation of a diode array for enhanced dynamic wedge dosimetry.

    abstract::The performance of a diode array (Profiler) was evaluated by comparing its enhanced dynamic wedge (EDW) profiles measured at various depths with point measurements using a 0.03 cm3 ionization chamber on a commercial linear accelerator. The Profiler, which covers a 22.5 cm width, was used to measure larger field widths...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598019

    authors: Zhu TC,Ding L,Liu CR,Palta JR,Simon WE,Shi J

    更新日期:1997-07-01 00:00:00

  • SU-E-T-145: MRI Gel Dosimetry Applied to Dose Profile Determination for 50kV X-Ray Tube.

    abstract:PURPOSE:The aim of this study was to use MRI gel dosimetry to determine the dose profile of 50kV MAGNUM® X-ray tube, MOXTEK Inc., in order to calibrate small solid dosimeters of alanine, tooth enamel and LiF-TLDs, commonly used in clinical quality assurance and datation dosimetry. METHODS:MAGIC-f polymer gel was kept ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735203

    authors: Schwarcke M,Marques T,Nicolucci P,Filho OB

    更新日期:2012-06-01 00:00:00

  • Breast tumor segmentation in 3D automatic breast ultrasound using Mask scoring R-CNN.

    abstract:PURPOSE:Automatic breast ultrasound (ABUS) imaging has become an essential tool in breast cancer diagnosis since it provides complementary information to other imaging modalities. Lesion segmentation on ABUS is a prerequisite step of breast cancer computer-aided diagnosis (CAD). This work aims to develop a deep learnin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14569

    authors: Lei Y,He X,Yao J,Wang T,Wang L,Li W,Curran WJ,Liu T,Xu D,Yang X

    更新日期:2020-10-30 00:00:00

  • A survey of the information gained from planning treatment with a computer.

    abstract::We designed a questionnaire to be filled out by the physicist at the time of planning treatment with the aid of a computer in order to assess what was learned during the course of the planning session. We analyzed the results to gauge the impact of the 70 treatment planning sessions conducted during the one month peri...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596302

    authors: Doppke KP,Goitein M

    更新日期:1988-03-01 00:00:00

  • A phantom for visualization of three-dimensional drug release by ultrasound-induced mild hyperthermia.

    abstract:PURPOSE:Ultrasound-induced mild hyperthermia has advantages for noninvasive, localized and controlled drug delivery. In this study, a tissue-mimicking agarose-based phantom with a thermally sensitive indicator was developed for studying the spatial drug delivery profile using ultrasound-induced mild hyperthermia. METH...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4813299

    authors: Lai CY,Kruse D,Seo JW,Kheirolomoom A,Ferrara KW

    更新日期:2013-08-01 00:00:00

  • A mobile isocentric C-arm for intraoperative cone-beam CT: Technical assessment of dose and 3D imaging performance.

    abstract:PURPOSE:To characterize the radiation dose and three-dimensional (3D) imaging performance of a recently developed mobile, isocentric C-arm equipped with a flat-panel detector (FPD) for intraoperative cone-beam computed tomography (CBCT) (Cios Spin 3D, Siemens Healthineers) and to identify potential improvements in 3D i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13983

    authors: Sheth NM,De Silva T,Uneri A,Ketcha M,Han R,Vijayan R,Osgood GM,Siewerdsen JH

    更新日期:2020-03-01 00:00:00

  • Comparison of p-type commercial electron diodes for in vivo dosimetry.

    abstract::This paper compares the characteristics of three types of commercial p-type electron diodes specially designed for in vivo dosimetry (Scanditronix EDD2, Sun Nuclear QED 111200-0 and PTW T60010E diodes coupled with a Therados DPD510 dosimeter) in electron fields with energies from 4.5 to 21 MeV, and in conditions simil...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1630492

    authors: Marre D,Marinello G

    更新日期:2004-01-01 00:00:00

  • A multipinhole small animal SPECT system with submillimeter spatial resolution.

    abstract::Single photon emission computed tomography (SPECT) is an important technology for molecular imaging studies of small animals. In this arena, there is an increasing demand for high performance imaging systems that offer improved spatial resolution and detection efficiency. We have designed a multipinhole small animal i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2190332

    authors: Funk T,Després P,Barber WC,Shah KS,Hasegawa BH

    更新日期:2006-05-01 00:00:00

  • Simplifying volumes-of-interest (VOIs) definition in quantitative SPECT: Beyond manual definition of 3D whole-organ VOIs.

    abstract:PURPOSE:We investigated the feasibility of using simpler methods than manual whole-organ volume-of-interest (VOI) definition to estimate the organ activity concentration in single photon emission computed tomography (SPECT) in cases where the activity in the organ can be assumed to be uniformly distributed on the scale...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12164

    authors: Vicente EM,Lodge MA,Rowe SP,Wahl RL,Frey EC

    更新日期:2017-05-01 00:00:00

  • Improved quantification of radionuclide uptake using deconvolution and windowed subtraction techniques for scatter compensation in single photon emission computed tomography.

    abstract::A comparison of two methods of scatter compensation in single photon emission computed tomography (SPECT) imaging is made on the basis of improvements in quantification. The methods, scatter-window subtraction and constrained deconvolution of an average point source response function (PSRF), are described; the theoret...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596453

    authors: Yanch JC,Flower MA,Webb S

    更新日期:1990-11-01 00:00:00

  • Poster - Thur Eve - 18: Characterization of a camera and LED lightbox imaging system for radiochromic film dosimetry.

    abstract::Radiation therapy treatment modalities continue to develop and have become increasingly complex. With this, dose verification and quality assurance (QA) is of great importance to ensure that a prescribed dose is accurately and precisely delivered to a patient. Radiochromic film dosimetry has been adopted as a convenie...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740126

    authors: Alexander K,Percy E,Olding T,Schreiner LJ,Salomons G

    更新日期:2012-07-01 00:00:00

  • A pencil beam algorithm for magnetic resonance image-guided proton therapy.

    abstract:PURPOSE:The feasibility of magnetic resonance image (MRI)-based proton therapy is based, among several other factors, on the implementation of appropriate extensions on current dose calculation methods. This work aims to develop a pencil beam algorithm (PBA) for dose calculation of proton beams within magnetic field re...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12854

    authors: Padilla-Cabal F,Georg D,Fuchs H

    更新日期:2018-05-01 00:00:00

  • An automated dosimetry data-acquisition and analysis system at the LAMPF pion therapy facility.

    abstract::An automated data-acquisition and analysis system has been developed for dosimetry measurements on the pion therapy beam at the Clinton P. Anderson Meson Physics Facility Biomedical Channel in Los Alamos using a PDP-11/45 computer and CAMAC interface. Initialization, test, and monitor programs allow the user to set th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594418

    authors: Rosen I,Smith A,Lane R,Kelsey C,Lake D,Hogstrom K,Somers J,Helland J,Kittell R,Amols H,Bradbury J,Richman C

    更新日期:1978-03-01 00:00:00

  • Small SRS photon field profile dosimetry performed using a PinPoint air ion chamber, a diamond detector, a novel silicon-diode array (DOSI), and polymer gel dosimetry. Analysis and intercomparison.

    abstract::Small photon fields are increasingly used in modern radiotherapy and especially in IMRT and SRS/SRT treatments. The uncertainties related to small field profile measurements can introduce significant systematic errors to the overall treatment process. These measurements are challenging mainly due to the absence of cha...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2977829

    authors: Pappas E,Maris TG,Zacharopoulou F,Papadakis A,Manolopoulos S,Green S,Wojnecki C

    更新日期:2008-10-01 00:00:00

  • A moving slanted-edge method to measure the temporal modulation transfer function of fluoroscopic systems.

    abstract::Lag in fluoroscopic systems introduces a frame-averaging effect that reduces measurements of image noise and incorrectly inflates measurements of the detective quantum efficiency (DQE). A correction can be implemented based on measurements of the temporal modulation transfer function (MTF). We introduce a method of me...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2919724

    authors: Friedman SN,Cunningham IA

    更新日期:2008-06-01 00:00:00

  • Determination of electron energy, spectral width, and beam divergence at the exit window for clinical megavoltage x-ray beams.

    abstract::Monte Carlo simulations of x-ray beams typically take parameters of the electron beam in the accelerating waveguide to be free parameters. In this paper, a methodology is proposed and implemented to determine the energy, spectral width, and beam divergence of the electron source. All treatment head components were rem...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3070547

    authors: Sawkey DL,Faddegon BA

    更新日期:2009-03-01 00:00:00

  • Systematic calibration of an integrated x-ray and optical tomography system for preclinical radiation research.

    abstract:PURPOSE:The cone beam computed tomography (CBCT) guided small animal radiation research platform (SARRP) has been developed for focal tumor irradiation, allowing laboratory researchers to test basic biological hypotheses that can modify radiotherapy outcomes in ways that were not feasible previously. CBCT provides exce...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4914860

    authors: Yang Y,Wang KK,Eslami S,Iordachita II,Patterson MS,Wong JW

    更新日期:2015-04-01 00:00:00

  • Theoretical study of temperature elevation at muscle/bone interface during ultrasound hyperthermia.

    abstract::This paper examines the distributions of the SAR (specific absorption rate) ratio and temperature elevation when an ultrasound beam propagates through the interface of muscle and bone. This interface is regarded as a flat boundary to partition the energy of the ultrasound beam, and the analytical solution of temperatu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598979

    authors: Lin WL,Liauh CT,Chen YY,Liu HC,Shieh MJ

    更新日期:2000-05-01 00:00:00

  • Real-time distortionless high-factor compression scheme.

    abstract::Nowadays, digital subtraction angiography systems must be able to sustain real-time acquisition (30 frames per second) of 512 x 512 x 8 bit images and store several sequences of such images on low cost and general-purpose mass memories. Concretely, that means a 7.8 Mbytes per second rate and about 780 Mbytes disk spac...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596309

    authors: Liénard J

    更新日期:1989-11-01 00:00:00

  • The effects of target size and tissue density on the minimum margin required for random errors.

    abstract::The minimum margins required to compensate for random geometric uncertainties in the delivery of radiotherapy treatment were determined for a spherical Clinical Target Volume, using an analytic model for the cumulative dose. Margins were calculated such that the minimum dose in the target would be no less than 95% of ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1809991

    authors: Witte MG,van der Geer J,Schneider C,Lebesque JV,van Herk M

    更新日期:2004-11-01 00:00:00

  • An adaptive probabilistic atlas for anomalous brain segmentation in MR images.

    abstract:PURPOSE:Automated segmentation of brain structures (objects) in MR three-dimensional (3D) images for quantitative analysis has been a challenge and probabilistic atlases (PAs) are among the most well-succeeded approaches. However, the existing models do not adapt to possible object anomalies due to the presence of a di...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13771

    authors: Martins SB,Bragantini J,Falcão AX,Yasuda CL

    更新日期:2019-11-01 00:00:00

  • Determination of the photon spectrum of a clinical accelerator.

    abstract::An experiment to determine the peak of the energy spectrum of the photon beam from a Toshiba LMR-15 medical linear accelerator is described. It is found that the flattening filters removed much of the bremsstrahlung spectrum below approximately 1 MeV, resulting in a photon spectrum which peaks around 1.2 MeV. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595582

    authors: Brownridge J,Samnick S,Stiles P,Tipton P,Veselka J,Yeh N

    更新日期:1984-11-01 00:00:00

  • Multiattribute probabilistic prostate elastic registration (MAPPER): application to fusion of ultrasound and magnetic resonance imaging.

    abstract:PURPOSE:Transrectal ultrasound (TRUS)-guided needle biopsy is the current gold standard for prostate cancer diagnosis. However, up to 40% of prostate cancer lesions appears isoechoic on TRUS. Hence, TRUS-guided biopsy has a high false negative rate for prostate cancer diagnosis. Magnetic resonance imaging (MRI) is bett...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4905104

    authors: Sparks R,Bloch BN,Feleppa E,Barratt D,Moses D,Ponsky L,Madabhushi A

    更新日期:2015-03-01 00:00:00

  • Balancing dose and image registration accuracy for cone beam tomosynthesis (CBTS) for breast patient setup.

    abstract:PURPOSE:To balance dose reduction and image registration accuracy in breast setup imaging. In particular, the authors demonstrate the relationship between scan angle and dose delivery for cone beam tomosynthesis (CBTS) when employed for setup verification of breast cancer patients with surgical clips. METHODS:The dose...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3464716

    authors: Winey BA,Zygmanski P,Cormack RA,Lyatskaya Y

    更新日期:2010-08-01 00:00:00

  • A fast GPU-based Monte Carlo simulation of proton transport with detailed modeling of nonelastic interactions.

    abstract:PURPOSE:Very fast Monte Carlo (MC) simulations of proton transport have been implemented recently on graphics processing units (GPUs). However, these MCs usually use simplified models for nonelastic proton-nucleus interactions. Our primary goal is to build a GPU-based proton transport MC with detailed modeling of elast...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4921046

    authors: Wan Chan Tseung H,Ma J,Beltran C

    更新日期:2015-06-01 00:00:00

  • Beam scanning for heavy charged particle radiotherapy.

    abstract::An important aspect of heavy charged particle radiotherapy is its ability to localize dose to the target volume. Current techniques generally employ beam delivery schemes which use range modulated beams in which the Bragg peak is spread out over a range of depths. The range modulation is constant over the entire beam ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595419

    authors: Goitein M,Chen GT

    更新日期:1983-11-01 00:00:00

  • Simultaneous super-resolution and contrast synthesis of routine clinical magnetic resonance images of the knee for improving automatic segmentation of joint cartilage: data from the Osteoarthritis Initiative.

    abstract:PURPOSE:High resolution three-dimensional (3D) magnetic resonance (MR) images are well suited for automated cartilage segmentation in the human knee joint. However, volumetric scans such as 3D Double-Echo Steady-State (DESS) images are not routinely acquired in clinical practice which limits opportunities for reliable ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14421

    authors: Neubert A,Bourgeat P,Wood J,Engstrom C,Chandra SS,Crozier S,Fripp J

    更新日期:2020-10-01 00:00:00

  • Dosimetric impact of motion in free-breathing and gated lung radiotherapy: a 4D Monte Carlo study of intrafraction and interfraction effects.

    abstract::The purpose of this study was to investigate if interfraction and intrafraction motion in free-breathing and gated lung IMRT can lead to systematic dose differences between 3DCT and 4DCT. Dosimetric effects were studied considering the breathing pattern of three patients monitored during the course of their treatment ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2821704

    authors: Seco J,Sharp GC,Wu Z,Gierga D,Buettner F,Paganetti H

    更新日期:2008-01-01 00:00:00

  • Attenuation, scattering, and absorption of ultrasound in the skull bone.

    abstract:PURPOSE:Measured values of ultrasound attenuation in bone represent a combination of different loss mechanisms. As a wave is transmitted from a fluid into bone, reflections occur at the interface. In the bone, mode conversion occurs between longitudinal and shear modes and the mechanical wave is scattered by its comple...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3668316

    authors: Pinton G,Aubry JF,Bossy E,Muller M,Pernot M,Tanter M

    更新日期:2012-01-01 00:00:00

  • WE-E-217BCD-02: Update on the Upcoming ACR Digital Mammography QC Manual.

    abstract:PURPOSE:We propose a new metric called Distance Discordance (DD), which is defined as the distance between two anatomic points from two moving images, which are co-located on some reference image, when deformed onto another reference image. METHODS:To demonstrate the concept of DD, we created a reference software phan...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736139

    authors: Berns E

    更新日期:2012-06-01 00:00:00