SU-E-T-145: MRI Gel Dosimetry Applied to Dose Profile Determination for 50kV X-Ray Tube.

Abstract:

PURPOSE:The aim of this study was to use MRI gel dosimetry to determine the dose profile of 50kV MAGNUM® X-ray tube, MOXTEK Inc., in order to calibrate small solid dosimeters of alanine, tooth enamel and LiF-TLDs, commonly used in clinical quality assurance and datation dosimetry. METHODS:MAGIC-f polymer gel was kept in two plastic containers of 100mL, avoiding attenuation of the primary beam trough the wall. Beam aberture of 3mm and dose rate of 16.5Gy/min were set, reproducing irradiation conditions of interest. The dose rate was assumed based on data of the vendor information of the tube and dose of 30Gy was delivered at the surface of the gel. MAGIC-f gel was irradiated at source-surface distances(SSD) of 0.1cm and 1.0cm. After 24hours of irradiation, gel was scanned in an Achieva® 3T Philips® MRI tomography using relaxometry sequence with 32 Echos, Time-to-Echo(TE) of 15.0ms, Time-to-Repetition(TR) of 6000ms and Field-of-View(FOV) of 0.5×0.5×2.0mm. Dose map at the central plain of irradiation was calculated from T2 relaxometry map. RESULTS:The gel dosimetry results evidenced a build-up depth of 0.13cm for SSD=0.1cm and no build-up was detected for SSD=1.0cm. However, the dose profile evidenced high gradient of dose in SSD=0.1, decreasing the dose from 100% to 30% in 1.4cm depth inside the gel; In turn, the dose distribution is homogeneous after 0.4cm deth for SSD=1.0cm. CONCLUSIONS:MRI gel dosimetry using MAGIC-f presented as feasible technique to determine dose profiles for kilovoltage x-rays tubes. The results evidenced that the calibration of small solid dosimeters can be performed using SSD of 1.0cm in the 50kV MAGNUM® X-ray tube using 0.4cm/g/cm3 filter. This work was funded supported by CNPQ, CAPES and FAPESP.

journal_name

Med Phys

journal_title

Medical physics

authors

Schwarcke M,Marques T,Nicolucci P,Filho OB

doi

10.1118/1.4735203

subject

Has Abstract

pub_date

2012-06-01 00:00:00

pages

3736

issue

6Part12

eissn

0094-2405

issn

2473-4209

journal_volume

39

pub_type

杂志文章
  • Patient doses and projection angle in cone beam CT.

    abstract:PURPOSE:To investigate how x-ray tube projection angle affects organ and effective doses to patients undergoing a CT examination on a cone beam scanner. METHODS:The authors investigated two cone beam CT systems that use a flat panel detector to capture the x-ray pattern transmitted through patients. One system had the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3397458

    authors: He W,Huda W,Magill D,Tavrides E,Yao H

    更新日期:2010-05-01 00:00:00

  • Model-based geometric calibration for medical x-ray systems.

    abstract:PURPOSE:Currently applied calibration approaches lead to satisfying 3D roadmapping overlay and 3D reconstruction accuracies; however, the required calibration times are extensive. The aim of this paper is the introduction of a novel model-based approach for geometric system calibrations, leading to a significant reduct...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4931964

    authors: van der Maas R,de Jager B,Steinbuch M,Dries J

    更新日期:2015-11-01 00:00:00

  • A computer simulation of wavelet noise reduction in computed tomography.

    abstract::We describe the use of a graphical mathematical spreadsheet programming environment which can be used to simulate the acquisition and reconstruction processes of an x-ray computed tomography (CT) machine. The simulation is used to study the effect of photon counting statistics on the noise in the reconstructed image. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598654

    authors: Harpen MD

    更新日期:1999-08-01 00:00:00

  • Static multileaf collimator for fast-neutron therapy.

    abstract::This paper describes a multileaf collimator, designed to obtain irregularly shaped neutron fields, that fits into an existing fixed field-size collimator system. The shape of the desired portal field is obtained by appropriately setting the position of each leaf of the collimator. The collimator consists of 40 polyeth...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596084

    authors: Chu JC,Bloch P

    更新日期:1987-03-01 00:00:00

  • Influence of 0.35 T magnetic field on the response of EBT3 and EBT-XD radiochromic films.

    abstract:PURPOSE:To investigate the inconsistency of recent literature on the effect of magnetic field on the response of radiochromic films, we studied the influence of 0.35 T magnetic field on dosimetric response of EBT3 and EBT-XD GafchromicTM films. METHODS:Two different models of radiochromic films, EBT3 and EBT-XD, were ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14313

    authors: Darafsheh A,Hao Y,Maraghechi B,Cammin J,Reynoso FJ,Khan R

    更新日期:2020-09-01 00:00:00

  • Energy spectra due to the intrinsic radiation of LYSO/LSO scintillators for a wide range of crystal sizes.

    abstract::Most detectors in current positron emission tomography (PET) scanners and prototypes use lutetium oxyorthosilicate (LSO) or lutetium yttrium oxyorthosilicate (LYSO) scintillators. The aim of this work is to provide a complete set of background energy spectra, due to the scintillator intrinsic radioactivity, for a wide...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14729

    authors: Domínguez-Jiménez DY,Alva-Sánchez H

    更新日期:2021-01-21 00:00:00

  • Investigating CT to CBCT image registration for head and neck proton therapy as a tool for daily dose recalculation.

    abstract:PURPOSE:Intensity modulated proton therapy (IMPT) of head and neck (H&N) cancer patients may be improved by plan adaptation. The decision to adapt the treatment plan based on a dose recalculation on the current anatomy requires a diagnostic quality computed tomography (CT) scan of the patient. As gantry-mounted cone be...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4908223

    authors: Landry G,Nijhuis R,Dedes G,Handrack J,Thieke C,Janssens G,Orban de Xivry J,Reiner M,Kamp F,Wilkens JJ,Paganelli C,Riboldi M,Baroni G,Ganswindt U,Belka C,Parodi K

    更新日期:2015-03-01 00:00:00

  • A limit on dose reduction possible with CT reconstruction algorithms without prior knowledge of the scan subject.

    abstract:PURPOSE:To find an upper bound on the maximum dose reduction possible for any reconstruction algorithm, analytic or iterative, that result from the inclusion of the data statistics. The authors do not analyze noise reduction possible from prior knowledge or assumptions about the object. METHODS:The authors examined th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4941954

    authors: Hsieh SS,Chesler DA,Fleischmann D,Pelc NJ

    更新日期:2016-03-01 00:00:00

  • Maximum likelihood estimation in calibrating a stereo camera setup.

    abstract::Motion and deformation of the cardiac wall may be measured by following the positions of implanted radiopaque markers in three dimensions, using two x-ray cameras simultaneously. Regularly, calibration of the position measurement system is obtained by registration of the images of a calibration object, containing 10-2...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598518

    authors: Muijtjens AM,Roos JM,Arts T,Hasman A

    更新日期:1999-02-01 00:00:00

  • Technical Note: Compact three-tesla magnetic resonance imager with high-performance gradients passes ACR image quality and acoustic noise tests.

    abstract:PURPOSE:A compact, three-tesla magnetic resonance imaging (MRI) system has been developed. It features a 37 cm patient aperture, allowing the use of commercial receiver coils. Its design allows simultaneously for gradient amplitudes of 85 millitesla per meter (mT/m) sustained and 700 tesla per meter per second (T/m/s) ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4941362

    authors: Weavers PT,Shu Y,Tao S,Huston J 3rd,Lee SK,Graziani D,Mathieu JB,Trzasko JD,Foo TK,Bernstein MA

    更新日期:2016-03-01 00:00:00

  • Ultrasonic Nakagami-parameter characterization of parotid-gland injury following head-and-neck radiotherapy: a feasibility study of late toxicity.

    abstract:PURPOSE:The study aims to investigate whether Nakagami parameters--estimated from the statistical distribution of the backscattered ultrasound radio-frequency (RF) signals--could provide a means for quantitative characterization of parotid-gland injury resulting from head-and-neck radiotherapy. METHODS:A preliminary c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4862507

    authors: Yang X,Tridandapani S,Beitler JJ,Yu DS,Wu N,Wang Y,Bruner DW,Curran WJ,Liu T

    更新日期:2014-02-01 00:00:00

  • Performance evaluation of a diode array for enhanced dynamic wedge dosimetry.

    abstract::The performance of a diode array (Profiler) was evaluated by comparing its enhanced dynamic wedge (EDW) profiles measured at various depths with point measurements using a 0.03 cm3 ionization chamber on a commercial linear accelerator. The Profiler, which covers a 22.5 cm width, was used to measure larger field widths...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598019

    authors: Zhu TC,Ding L,Liu CR,Palta JR,Simon WE,Shi J

    更新日期:1997-07-01 00:00:00

  • A 3D ultrasound scanning system for image guided liver interventions.

    abstract:PURPOSE:Two-dimensional ultrasound (2D US) imaging is commonly used for diagnostic and intraoperative guidance of interventional liver procedures; however, 2D US lacks volumetric information that may benefit interventional procedures. Over the past decade, three-dimensional ultrasound (3D US) has been developed to prov...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4824326

    authors: Neshat H,Cool DW,Barker K,Gardi L,Kakani N,Fenster A

    更新日期:2013-11-01 00:00:00

  • Results from a multicenter prostate IMRT dosimetry intercomparison for an OCOG-TROG clinical trial.

    abstract:PURPOSE:A multi-institution dosimetry intercomparison has been undertaken of prostate intensity modulated radiation therapy (IMRT) delivery. The dosimetry intercomparison was incorporated into the quality assurance for site credentialing for the Trans-Tasman Radiation Oncology Group Prostate Fractionated Irradiation Tr...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1118/1.4808151

    authors: Healy B,Frantzis J,Murry R,Martin J,Plank A,Middleton M,Catton C,Kron T

    更新日期:2013-07-01 00:00:00

  • Comparison of Gafchromic EBT2 and EBT3 films for clinical photon and proton beams.

    abstract:PURPOSE:Dose verification in highly conformal radiation therapy such as IMRT or proton therapy can benefit from the high spatial resolution offered by radio-chromic films such as Gafchromic EBT or EBT2. Recently, a new generation of these films, EBT3, has become available. The composition and thickness of the sensitive...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4737890

    authors: Reinhardt S,Hillbrand M,Wilkens JJ,Assmann W

    更新日期:2012-08-01 00:00:00

  • A strategy to decrease partial scan reconstruction artifacts in myocardial perfusion CT: phantom and in vivo evaluation.

    abstract:PURPOSE:Partial scan reconstruction (PSR) artifacts are present in myocardial perfusion imaging using dynamic multidetector computed tomography (MDCT). PSR artifacts appear as temporal CT number variations due to inconsistencies in the angular data range used to reconstruct images and compromise the quantitative value ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3665767

    authors: Ramirez-Giraldo JC,Yu L,Kantor B,Ritman EL,McCollough CH

    更新日期:2012-01-01 00:00:00

  • Investigations of interference between electromagnetic transponders and wireless MOSFET dosimeters: a phantom study.

    abstract:PURPOSE:To evaluate both the Calypso Systems' (Calypso Medical Technologies, Inc., Seattle, WA) localization accuracy in the presence of wireless metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters of dose verification system (DVS, Sicel Technologies, Inc., Morrisville, NC) and the dosimeters' reading...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3578602

    authors: Su Z,Zhang L,Ramakrishnan V,Hagan M,Anscher M

    更新日期:2011-05-01 00:00:00

  • In vivo dosimetry by an aSi-based EPID.

    abstract::A method for the in vivo determination of the isocenter dose, Diso, and mid-plane dose, Dm, using the transmitted signal St measured by 25 central pixels of an aSi-based EPID is here reported. The method has been applied to check the conformal radiotherapy of pelvic tumors and supplies accurate in vivo dosimetry avoid...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2360014

    authors: Piermattei A,Fidanzio A,Stimato G,Azario L,Grimaldi L,D'Onofrio G,Cilla S,Balducci M,Gambacorta MA,Di Napoli N,Cellini N

    更新日期:2006-11-01 00:00:00

  • An improved bolus configuration for commercial multielement ultrasound and microwave hyperthermia systems.

    abstract::A simple modification is presented for two commercially available hyperthermia applicators which dramatically improves the regulation and dynamic control of the temperature at the bolus/tissue interface. This alteration requires the addition of a variable speed pump, bubble trap, simple heat exchanger, and a few minor...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597196

    authors: Diederich CJ,Stauffer PR,Bozzo D

    更新日期:1994-09-01 00:00:00

  • Vision 20/20: Magnetic resonance imaging-guided attenuation correction in PET/MRI: Challenges, solutions, and opportunities.

    abstract::Attenuation correction is an essential component of the long chain of data correction techniques required to achieve the full potential of quantitative positron emission tomography (PET) imaging. The development of combined PET/magnetic resonance imaging (MRI) systems mandated the widespread interest in developing nov...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.4941014

    authors: Mehranian A,Arabi H,Zaidi H

    更新日期:2016-03-01 00:00:00

  • Sensitivity of amorphous selenium to x rays from 40 kVp to 18 MV: measurements and implications for portal imaging.

    abstract::Recently, the clinical application of electronic portal imaging devices has enabled more frequent verification of patient setup for radiation treatment. However, the image quality has sometimes proven to be inadequate, motivating the investigation of alternative sensors with better image quality. Amorphous selenium (a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598219

    authors: Mah D,Rowlands JA,Rawlinson JA

    更新日期:1998-04-01 00:00:00

  • Proliferative diabetic retinopathy characterization based on fractal features: Evaluation on a publicly available dataset.

    abstract:PURPOSE:Diabetic retinopathy (DR) is one of the most widespread causes of preventable blindness in the world. The most dangerous stage of this condition is proliferative DR (PDR), in which the risk of vision loss is high and treatments are less effective. Fractal features of the retinal vasculature have been previously...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12627

    authors: Orlando JI,van Keer K,Barbosa Breda J,Manterola HL,Blaschko MB,Clausse A

    更新日期:2017-12-01 00:00:00

  • Technical Note: Evaluation of a 160-mm/256-row CT scanner for whole-heart quantitative myocardial perfusion imaging.

    abstract:PURPOSE:The authors investigated the performance of a recently introduced 160-mm/256-row CT system for low dose quantitative myocardial perfusion (MP) imaging of the whole heart. This platform is equipped with a gantry capable of rotating at 280 ms per full cycle, a second generation of adaptive statistical iterative r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4957389

    authors: So A,Imai Y,Nett B,Jackson J,Nett L,Hsieh J,Wisenberg G,Teefy P,Yadegari A,Islam A,Lee TY

    更新日期:2016-08-01 00:00:00

  • SU-E-T-429: Image-Guided Eye Plaque Brachytherapy Optimization: Implications for Patients at 2-Year Follow-up.

    abstract:PURPOSE:Episcleral eye plaque brachytherapy has been utilized in the treatment of intra-ocular malignancies, delivering large prescription doses to the apex of the tumor. Advances in dose calculation and image guidance, via calibrated fundus images, enable localization of the tumor and determination of dose to the macu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735518

    authors: Guida K,Niermann K,Malcolm A,Sternberg P,Munn G,Coffey C

    更新日期:2012-06-01 00:00:00

  • Astigmatic single photon emission computed tomography imaging with a displaced center of rotation.

    abstract::A filtered backprojection algorithm is developed for single photon emission computed tomography (SPECT) imaging with an astigmatic collimator having a displaced center of rotation. The astigmatic collimator has two perpendicular focal lines, one that is parallel to the axis of rotation of the gamma camera and one that...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598325

    authors: Wang H,Smith MF,Stone CD,Jaszczak RJ

    更新日期:1998-08-01 00:00:00

  • Automated lung segmentation of diseased and artifact-corrupted magnetic resonance sections.

    abstract::Segmentation of the lungs within magnetic resonance (MR) scans is a necessary step in the computer-based analysis of thoracic MR images. This process is often confounded by image acquisition artifacts and disease-induced morphological deformation. We have developed an automated method for lung segmentation that is ins...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2214165

    authors: Sensakovic WF,Armato SG 3rd,Starkey A,Caligiuri P

    更新日期:2006-09-01 00:00:00

  • A novel respiratory tracking system for smart-gated PET acquisition.

    abstract:PURPOSE:In this study, the authors validated a novel respiratory tracking device, the multidimensional respiratory tracking (MDRT) system, that was designed to assist in correcting for respiratory motion in PET/CT images. The authors also investigated a novel PET acquisition technique, smart gating (SG), that enables t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3523100

    authors: Nehmeh SA,Haj-Ali AA,Qing C,Stearns C,Kalaigian H,Kohlmyer S,Schoder H,Ho AY,Larson SM,Humm JL

    更新日期:2011-01-01 00:00:00

  • Calculation of x-ray spectra emerging from an x-ray tube. Part II. X-ray production and filtration in x-ray targets.

    abstract::A new approach to the calculation of the x-ray spectrum emerging from an x-ray tube is proposed. Theoretical results for the bremsstrahlung cross section appearing in the literature are summarized. Four different treatments of electron penetration, based on the work presented in Part I, are then used to generate brems...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2734726

    authors: Poludniowski GG

    更新日期:2007-06-01 00:00:00

  • Technical Note: exploring the limit for the conversion of energy-subtracted CT number to electron density for high-atomic-number materials.

    abstract:PURPOSE:For accurate tissue inhomogeneity correction in radiotherapy treatment planning, the authors had previously proposed a novel conversion of the energy-subtracted CT number to an electron density (ΔHU-ρe conversion), which provides a single linear relationship between ΔHU and ρe over a wide ρe range. The purpose ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4881327

    authors: Saito M,Tsukihara M

    更新日期:2014-07-01 00:00:00

  • Nonlinear magnetic stereotaxis: three-dimensional, in vivo remote magnetic manipulation of a small object in canine brain.

    abstract::In a series of in vivo experiments on five adult canines, a small cylindrical permanent magnet (approximately 5-mm diameter x 5 mm long) was magnetically moved under fluoroscopic guidance from an occipital-lobe burr hole to a predetermined destination within the brain and then removed. On three of the animals, dorsal ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596520

    authors: Grady MS,Howard MA 3rd,Molloy JA,Ritter RC,Quate EG,Gillies GT

    更新日期:1990-05-01 00:00:00