In vivo dosimetry by an aSi-based EPID.

Abstract:

:A method for the in vivo determination of the isocenter dose, Diso, and mid-plane dose, Dm, using the transmitted signal St measured by 25 central pixels of an aSi-based EPID is here reported. The method has been applied to check the conformal radiotherapy of pelvic tumors and supplies accurate in vivo dosimetry avoiding many of the disadvantages associated with the use of two diode detectors (at the entrance and exit of the patient) as their periodic recalibration and their positioning. Irradiating water-equivalent phantoms of different thicknesses, a set of correlation functions F(w, l) were obtained by the ratio between St and Dm as a function of the phantom thickness, w, for a different field width, l. For the in vivo determination of Diso and Dm values, the water-equivalent thickness of the patients (along the beam central axis) was evaluated by means of the treatment planning system that uses CT scans calibrated in terms of the electron densities. The Diso and Dm values experimentally determined were compared with the stated doses D(iso,TPS) and D(m,TPS), determined by the treatment planning system for ten pelvic treatments. In particular, for each treatment four fields were checked in six fractions. In these conditions the agreement between the in vivo dosimetry and stated doses at the isocenter point were within 3%. Comparing the 480 dose values obtained in this work with those obtained for 30 patients tested with a similar method, which made use of a small ion-chamber positioned on the EPIDs to obtain the transmitted signal, a similar agreement was observed. The method here proposed is very practical and can be applied in every treatment fraction, supplying useful information about eventual patient dose variations due to the incorrect application of the quality assurance program based on the check of patient setup, machine setting, and calculations.

journal_name

Med Phys

journal_title

Medical physics

authors

Piermattei A,Fidanzio A,Stimato G,Azario L,Grimaldi L,D'Onofrio G,Cilla S,Balducci M,Gambacorta MA,Di Napoli N,Cellini N

doi

10.1118/1.2360014

subject

Has Abstract

pub_date

2006-11-01 00:00:00

pages

4414-22

issue

11

eissn

0094-2405

issn

2473-4209

journal_volume

33

pub_type

杂志文章
  • Clinical Target Volume Segmentation for Stomach Cancer by Stochastic Width Deep Neural Network.

    abstract:PURPOSE:Precise segmentation of clinical target volume (CTV) is the key to stomach cancer radiotherapy. We proposed a novel stochastic width - deep neural network (SW-DNN) for better automatically contouring stomach CTV METHODS: SW-DNN was an end-to-end approach, of which the core component was a novel SW mechanism tha...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14733

    authors: Xu L,Hu J,Song Y,Bai S,Yi Z

    更新日期:2021-01-27 00:00:00

  • SU-D-BRCD-02: A Novel Cylindrical 3D Water Scanner for Beam Data Collection: I. Validation of the Automatic-Setup.

    abstract:PURPOSE:To determine the accuracy and reproducibility of the automatic- setup procedure of a 3D water scanner (3D SCANNER, Sun Nuclear Corp). The procedure automatically aligns the scanner's coordinate system to the Linac coordinate system. A unique off-center detector holder extends the scan range to 630 mm, eliminati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734668

    authors: Li J,Lu B,Yan G,Huang Y,Liu C

    更新日期:2012-06-01 00:00:00

  • Dosimetry for radiocolloid therapy of cystic craniopharyngiomas.

    abstract::The dosimetry for radiocolloid therapy of cystic craniopharyngiomas is investigated. Analytical calculations based on the Loevinger and the Berger formulas for electrons and photons, respectively, are compared with Monte Carlo simulations. The role of the material of which the colloid introduced inside the craniophary...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1599653

    authors: Rojas EL,Al-Dweri FM,Lallena AM,Bodineau C,Galán P

    更新日期:2003-09-01 00:00:00

  • Convolutional neural network-based dosimetry evaluation of esophageal radiation treatment planning.

    abstract:PURPOSE:A dosimetry evaluation model for treatment planning of esophageal radiation therapy is developed using a deep learning model. The model predicts dose volume histogram (DVH) from distance to target histogram (DTH) based on stacked de-noise auto-encoder (SDAE) and one-dimensional convolutional network (1D-CN). M...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14434

    authors: Jiang D,Yan H,Chang N,Li T,Mao R,Du C,Guo B,Liu J

    更新日期:2020-10-01 00:00:00

  • Assessment of flat panel LCD primary class display performance based on AAPM TG 18 acceptance protocol.

    abstract::The image display is an important component of the Picture Archiving and Communication System (PACS) and of digital imaging in general. In this paper, we assess the display performance of 32 different flat panel LCD devices, in terms of their reflection, luminance response, luminance uniformity, resolution, noise, vei...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1764946

    authors: Jung H,Kim HJ,Kang WS,Yoo SK,Fujioka K,Hasegawa M,Samei E

    更新日期:2004-07-01 00:00:00

  • Radiofrequency penetration and absorption in the human body: limitations to high-field whole-body nuclear magnetic resonance imaging.

    abstract::This study presents experimental results about the effective depth of penetration and about the radiofrequency (rf) power absorption in humans as a function of frequency. The frequency range investigated covers 10 up to 220 MHz. For the main part, the results were derived from bench measurements of the quality factor ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595995

    authors: Röschmann P

    更新日期:1987-11-01 00:00:00

  • Photon attenuation in computed tomography.

    abstract::The analysis and understanding of results of computed tomography (CT) require an understanding of photon attenuation in matter. The high sensitivity and resolution of these devices coupled with the use of a polychromatic photon source require a level and breadth of understanding about photon attenuation not usually re...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594199

    authors: McCullough EC

    更新日期:1975-11-01 00:00:00

  • Development of PET/MRI with insertable PET for simultaneous PET and MR imaging of human brain.

    abstract:PURPOSE:The purpose of this study was to develop a dual-modality positron emission tomography (PET)/magnetic resonance imaging (MRI) with insertable PET for simultaneous PET and MR imaging of the human brain. METHODS:The PET detector block was composed of a 4 × 4 matrix of detector modules, each consisting of a 4 × 4 ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4918321

    authors: Jung JH,Choi Y,Jung J,Kim S,Lim HK,Im KC,Oh CH,Park HW,Kim KM,Kim JG

    更新日期:2015-05-01 00:00:00

  • Influence of cold walls on PET image quantification and volume segmentation: a phantom study.

    abstract:PURPOSE:Commercially available fillable plastic inserts used in positron emission tomography phantoms usually have thick plastic walls, separating their content from the background activity. These "cold" walls can modify the intensity values of neighboring active regions due to the partial volume effect, resulting in e...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4813302

    authors: Berthon B,Marshall C,Edwards A,Evans M,Spezi E

    更新日期:2013-08-01 00:00:00

  • Calibration of a scintillation dosemeter for beta rays using an extrapolation ionization chamber.

    abstract::A scintillation dosemeter is calibrated for 90Sr/90Y beta rays from an ophthalmic applicator, using an extrapolation ionization chamber as a reference instrument. The calibration factor for the scintillation dosemeter agrees with that given by the manufacturer of the dosemeter within ca. 2%. The estimated overall unce...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1709490

    authors: Hakanen AT,Sipilä PM,Kosunen A

    更新日期:2004-05-01 00:00:00

  • Effect of T1-mapping technique and diminished image resolution on quantification of infarct mass and its ability in predicting appropriate ICD therapy.

    abstract:PURPOSE:Myocardial infarct (MI) may consist of an infarct core (IC) and a heterogeneous, semi-viable border zone (BZ). Patients with chronic MI in the left ventricular (LV) myocardium are at increased risk of developing ventricular arrhythmias, and may therefore qualify for implantable cardioverter defibrillator (ICD) ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12840

    authors: Farrag NA,Ramanan V,Wright GA,Ukwatta E

    更新日期:2018-04-01 00:00:00

  • Technical Note: 4D cone-beam CT reconstruction from sparse-view CBCT data for daily motion assessment in pencil beam scanned proton therapy (PBS-PT).

    abstract:PURPOSE:The number of pencil beam scanned proton therapy (PBS-PT) facilities equipped with cone-beam computed tomography (CBCT) imaging treating thoracic indications is constantly rising. To enable daily internal motion monitoring during PBS-PT treatments of thoracic tumors, we assess the performance of Motion-Aware Re...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14521

    authors: den Otter LA,Chen K,Janssens G,Meijers A,Both S,Langendijk JA,Rosen LR,Wu HT,Knopf AC

    更新日期:2020-12-01 00:00:00

  • SU-E-I-103: Detecting Anomalous Pixels and Correlated Artifacts in Digital Detectors from Flat-Field Images.

    abstract:PURPOSE:Anomalous pixels may be defined as those pixels whose exposure response relationship is deviant from the typical, expected or calibrated response. A group of anomalous pixels may Result in visible correlated artifacts. Here we demonstrate an approach to identify anomalous pixels and correlated artifacts using f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734820

    authors: Dave J,Gingold E,Yorkston J,Bercha I,Goldman L,Walz-Flannigan A,Willis C

    更新日期:2012-06-01 00:00:00

  • Determination of x-ray tube focal spot position.

    abstract::In x-ray spectral measurement using a semiconductor detector system, accurate positioning of the detector in front of the anode is very important. This needs accurate determination of the focal spot position on the target in an x-ray tube. We present a simple technique to determine the focal spot position accurately. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597122

    authors: Kubota H,Ozaki Y,Matsumoto M,Kanamori H

    更新日期:1993-07-01 00:00:00

  • Current status and future perspective of flattening filter free photon beams.

    abstract:PURPOSE:Flattening filters (FFs) have been considered as an integral part of the treatment head of a medical accelerator for more than 50 years. The reasons for the longstanding use are, however, historical ones. Advanced treatment techniques, such as stereotactic radiotherapy or intensity modulated radiotherapy have s...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.3554643

    authors: Georg D,Knöös T,McClean B

    更新日期:2011-03-01 00:00:00

  • Rotational micro-CT using a clinical C-arm angiography gantry.

    abstract::Rotational angiography (RA) gantries are used routinely to acquire sequences of projection images of patients from which 3D renderings of vascular structures are generated using Feldkamp cone-beam reconstruction algorithms. However, these systems have limited resolution (<4 lp/mm). Micro-computed tomography (micro-CT)...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1118/1.2989989

    authors: Patel V,Hoffmann KR,Ionita CN,Keleshis C,Bednarek DR,Rudin S

    更新日期:2008-10-01 00:00:00

  • Investigating energy deposition in glandular tissues for mammography using multiscale Monte Carlo simulations.

    abstract:PURPOSE:To investigate energy deposition in glandular tissues of the breast on macro- and microscopic length scales in the context of mammography. METHODS:Multiscale mammography models of breasts are developed, which include segmented, voxelized macroscopic tissue structure as well as nine regions of interest (ROIs) e...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13372

    authors: Oliver PAK,Thomson RM

    更新日期:2019-03-01 00:00:00

  • Effective and equivalent organ doses in patients undergoing coronary angiography and percutaneous coronary intervention.

    abstract:PURPOSE:Recent recommendations of the International Commission on Radiological Protection state that the use of effective dose (E) for assessing patient exposure has severe limitations, though it can be kept for dose comparisons. In cardiology procedures, the equivalent dose (H(T)) is one of the most appropriate dose q...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3561508

    authors: Compagnone G,Ortolani P,Domenichelli S,Ovi V,Califano G,Dall'Ara G,Marzocchi A

    更新日期:2011-04-01 00:00:00

  • Dual-storage phosphor proton therapy dosimetry: simultaneous quantification of dose and linear energy transfer.

    abstract:PURPOSE:To investigate the feasibility of using the high Zeff storage phosphor material BaFBrI:Eu2+ in conjunction with the low Zeff storage phosphor material KCl:Eu2+ for simultaneous proton dose and linear energy transfer (LET) measurements by 1) measuring the fundamental optical and dosimetric properties of BaFBrI:E...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14748

    authors: Setianegara J,Mazur TR,Yang D,Li HH

    更新日期:2021-02-01 00:00:00

  • Introduction of a novel dose saving acquisition mode for the PortalVision aS500 EPID to facilitate on-line patient setup verification.

    abstract::In external beam radiotherapy, electronic portal imaging becomes more and more an indispensable tool for the verification of the patient setup. For the safe clinical introduction of high dose conformal radiotherapy like intensity modulated radiation therapy, on-line patient setup verification is a prerequisite to ensu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1668391

    authors: Vetterli D,Riem H,Aebersold DM,Greiner RH,Manser P,Cossmann P,Kemmerling L,Born EJ,Mini R

    更新日期:2004-04-01 00:00:00

  • Quantitative study of focused ultrasound enhanced doxorubicin delivery to prostate tumor in vivo with MRI guidance.

    abstract:PURPOSE:The purpose of this study was to investigate the potential of MR-guided pulsed focused ultrasound (pFUS) for the enhancement of drug uptake in prostate tumors in vivo using doxorubicin (Dox). METHODS:An antitumor drug Dox, an orthotopic animal prostate tumor model using human prostate cancer, LNCaP cell line, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4705346

    authors: Chen X,Cvetkovic D,Ma CM,Chen L

    更新日期:2012-05-01 00:00:00

  • Learning-based automated segmentation of the carotid artery vessel wall in dual-sequence MRI using subdivision surface fitting.

    abstract:PURPOSE:The quantification of vessel wall morphology and plaque burden requires vessel segmentation, which is generally performed by manual delineations. The purpose of our work is to develop and evaluate a new 3D model-based approach for carotid artery wall segmentation from dual-sequence MRI. METHODS:The proposed me...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12476

    authors: Gao S,van 't Klooster R,Kitslaar PH,Coolen BF,van den Berg AM,Smits LP,Shahzad R,Shamonin DP,de Koning PJH,Nederveen AJ,van der Geest RJ

    更新日期:2017-10-01 00:00:00

  • A topographic leaf-sequencing algorithm for delivering intensity modulated radiation therapy.

    abstract::Topographic treatment is a radiation therapy delivery technique for fixed-gantry (nonrotational) treatments on a helical tomotherapy system. The intensity-modulated fields are created by moving the treatment couch relative to a fan-beam positioned at fixed gantry angles. The delivered dose distribution is controlled b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2216876

    authors: Desai D,Ramsey CR,Breinig M,Mahan SL

    更新日期:2006-08-01 00:00:00

  • Intensity inhomogeneity correction for magnetic resonance imaging of human brain at 7T.

    abstract:PURPOSE:To evaluate the performance and efficacy for intensity inhomogeneity correction of various sequences of the human brain in 7T MRI using the extended version of the unified segmentation algorithm. MATERIALS:Ten healthy volunteers were scanned with four different sequences (2D spin echo [SE], 3D fast SE, 2D fast...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4860954

    authors: Uwano I,Kudo K,Yamashita F,Goodwin J,Higuchi S,Ito K,Harada T,Ogawa A,Sasaki M

    更新日期:2014-02-01 00:00:00

  • Technical Note: Immunohistochemical evaluation of mouse brain irradiation targeting accuracy with 3D-printed immobilization device.

    abstract:PURPOSE:Small animal immobilization devices facilitate positioning of animals for reproducible imaging and accurate focal radiation therapy. In this study, the authors demonstrate the use of three-dimensional (3D) printing technology to fabricate a custom-designed mouse head restraint. The authors evaluate the accuracy...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4933200

    authors: Zarghami N,Jensen MD,Talluri S,Foster PJ,Chambers AF,Dick FA,Wong E

    更新日期:2015-11-01 00:00:00

  • Study of the secondary neutral radiation in proton therapy: toward an indirect in vivo dosimetry.

    abstract:PURPOSE:Secondary particles produced in the collision of protons with beam modifiers are of concern in proton therapy. Nevertheless, secondary radiation can provide information on the dosimetric parameters through its dependency on the modulating accessories (range shifter and range modulating wheel). Relatively little...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4765049

    authors: Carnicer A,Letellier V,Rucka G,Angellier G,Sauerwein W,Herault J

    更新日期:2012-12-01 00:00:00

  • Practical reconstruction protocol for quantitative (90)Y bremsstrahlung SPECT/CT.

    abstract:PURPOSE:To develop a practical background compensation (BC) technique to improve quantitative (90)Y-bremsstrahlung single-photon emission computed tomography (SPECT)/computed tomography (CT) using a commercially available imaging system. METHODS:All images were acquired using medium-energy collimation in six energy wi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4960629

    authors: Siman W,Mikell JK,Kappadath SC

    更新日期:2016-09-01 00:00:00

  • Updated breast CT dose coefficients (DgNCT ) using patient-derived breast shapes and heterogeneous fibroglandular distributions.

    abstract:PURPOSE:The purpose of this work was to generate uncompressed heterogeneous breast phantom models using size-dependent fibroglandular distributions derived from a large cohort of breast CT (bCT) datasets, and to compare differences in normalized glandular dose coefficients for bCT "DgNCT " when the realistic heterogene...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13391

    authors: Hernandez AM,Becker AE,Boone JM

    更新日期:2019-03-01 00:00:00

  • Quantification of body-torso-wide tissue composition on low-dose CT images via automatic anatomy recognition.

    abstract:PURPOSE:Quantification of body composition plays an important role in many clinical and research applications. Radiologic imaging techniques such as Dual-energy X-ray absorptiometry (DXA), magnetic resonance imaging (MRI), and computed tomography (CT) imaging make accurate quantification of the body composition possibl...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13373

    authors: Liu T,Udupa JK,Miao Q,Tong Y,Torigian DA

    更新日期:2019-03-01 00:00:00

  • The use of modified single pencil beam dose kernels to improve IMRT dose calculation accuracy.

    abstract::Intensity modulated radiation therapy (IMRT) is used to deliver highly conformal radiation doses to tumors while sparing nearby sensitive tissues. Discrepancies between calculated and measured dose distributions have been reported for regions of high dose gradients corresponding to complex radiation fluence patterns. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1812851

    authors: Bergman AM,Otto K,Duzenli C

    更新日期:2004-12-01 00:00:00