Use of local noise power spectrum and wavelet analysis in quantitative image quality assurance for EPIDs.

Abstract:

PURPOSE:To investigate the use of local noise power spectrum (NPS) to characterize image noise and wavelet analysis to isolate defective pixels and inter-subpanel flat-fielding artifacts for quantitative quality assurance (QA) of electronic portal imaging devices (EPIDs). METHODS:A total of 93 image sets including custom-made bar-pattern images and open exposure images were collected from four iViewGT a-Si EPID systems over three years. Global quantitative metrics such as modulation transform function (MTF), NPS, and detective quantum efficiency (DQE) were computed for each image set. Local NPS was also calculated for individual subpanels by sampling region of interests within each subpanel of the EPID. The 1D NPS, obtained by radially averaging the 2D NPS, was fitted to a power-law function. The r-square value of the linear regression analysis was used as a singular metric to characterize the noise properties of individual subpanels of the EPID. The sensitivity of the local NPS was first compared with the global quantitative metrics using historical image sets. It was then compared with two commonly used commercial QA systems with images collected after applying two different EPID calibration methods (single-level gain and multilevel gain). To detect isolated defective pixels and inter-subpanel flat-fielding artifacts, Haar wavelet transform was applied on the images. RESULTS:Global quantitative metrics including MTF, NPS, and DQE showed little change over the period of data collection. On the contrary, a strong correlation between the local NPS (r-square values) and the variation of the EPID noise condition was observed. The local NPS analysis indicated image quality improvement with the r-square values increased from 0.80 ± 0.03 (before calibration) to 0.85 ± 0.03 (after single-level gain calibration) and to 0.96 ± 0.03 (after multilevel gain calibration), while the commercial QA systems failed to distinguish the image quality improvement between the two calibration methods. With wavelet analysis, defective pixels and inter-subpanel flat-fielding artifacts were clearly identified as spikes after thresholding the inversely transformed images. CONCLUSIONS:The proposed local NPS (r-square values) showed superior sensitivity to the noise level variations of individual subpanels compared with global quantitative metrics such as MTF, NPS, and DQE. Wavelet analysis was effective in detecting isolated defective pixels and inter-subpanel flat-fielding artifacts. The proposed methods are promising for the early detection of imaging artifacts of EPIDs.

journal_name

Med Phys

journal_title

Medical physics

authors

Lee S,Yan G,Bassett P,Gopal A,Samant S

doi

10.1118/1.4959541

subject

Has Abstract

pub_date

2016-09-01 00:00:00

pages

4996

issue

9

eissn

0094-2405

issn

2473-4209

journal_volume

43

pub_type

杂志文章
  • Interplay effect on a 6-MV flattening-filter-free linear accelerator with high dose rate and fast multi-leaf collimator motion treating breast and lung phantoms.

    abstract:PURPOSE:Using a new linear accelerator with high dose rate (800 MU/min), fast MLC motions (5.0 cm/s), fast gantry rotation (15 s/rotation), and 1 cm wide MLCs, we aimed to quantify the effects of complexity, arc number, and fractionation on interplay for breast and lung treatments under target motion. METHODS:To study...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12899

    authors: Netherton T,Li Y,Nitsch P,Shaitelman S,Balter P,Gao S,Klopp A,Muruganandham M,Court L

    更新日期:2018-06-01 00:00:00

  • Technical Note: Impact of region of interest size and location in Gafchromic film dosimetry.

    abstract:PURPOSE:To evaluate dependence of measured dose on size and location of region of interest (ROI) in Gafchromic EBT3 film dosimetry. METHODS:Gafchromic EBT3 films were irradiated perpendicularly using the 6MV beam from a linear accelerator at 10 cm depth (100 cm SSD) of a 30 × 30 × 20 cm3 solid water phantom for a rang...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12885

    authors: Gholizadeh Sendani N,Karimian A,Ferreira C,Alaei P

    更新日期:2018-05-01 00:00:00

  • Estimation of organ doses from kilovoltage cone-beam CT imaging used during radiotherapy patient position verification.

    abstract:PURPOSE:The purpose of this study was to develop a practical method for estimating organ doses from kilovoltage cone-beam CT (CBCT) that can be performed with readily available phantoms and dosimeters. The accuracy of organ dose estimates made using the ImPACT patient dose calculator was also evaluated. METHODS:A 100 ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3476459

    authors: Hyer DE,Hintenlang DE

    更新日期:2010-09-01 00:00:00

  • Ultrasound viscoelasticity assessment using an adaptive torsional shear wave propagation method.

    abstract:PURPOSE:Different approaches have been used in dynamic elastography to assess mechanical properties of biological tissues. Most techniques are based on a simple inversion based on the measurement of the shear wave speed to assess elasticity, whereas some recent strategies use more elaborated analytical or finite elemen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4942813

    authors: Ouared A,Kazemirad S,Montagnon E,Cloutier G

    更新日期:2016-04-01 00:00:00

  • WE-E-213CD-03: Inverse-Consistent Symmetric Registration of Inner Colon Surfaces Derived from Prone and Supine CT Colonography.

    abstract:PURPOSE:Robust registration of prone and supine colonie surfaces acquired during CT colonography may lead to faster and more accurate detection of colorectal cancer and polyps. Any directional bias when registering one surface to the other could precipitate incorrect anatomical correspondence and engender reader error....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736159

    authors: Roth H,McClelland J,Modat M,Hampshire T,Boone D,Hu M,Ourselin S,Halligan S,Hawkes D

    更新日期:2012-06-01 00:00:00

  • Diamond detector versus silicon diode and ion chamber in photon beams of different energy and field size.

    abstract::The aim of this work was to test the suitability of a PTW diamond detector for nonreference condition dosimetry in photon beams of different energy (6 and 25 MV) and field size (from 2.6 cm x 2.6 cm to 10 cm x 10 cm). Diamond behavior was compared to that of a Scanditronix p-type silicon diode and a Scanditronix RK io...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1591431

    authors: Bucciolini M,Buonamici FB,Mazzocchi S,De Angelis C,Onori S,Cirrone GA

    更新日期:2003-08-01 00:00:00

  • Anniversary paper: evolution of ultrasound physics and the role of medical physicists and the AAPM and its journal in that evolution.

    abstract::Ultrasound has been the greatest imaging modality worldwide for many years by equipment purchase value and by number of machines and examinations. It is becoming increasingly the front end imaging modality; serving often as an extension of the physician's fingers. We believe that at the other extreme, high-end systems...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.2992048

    authors: Carson PL,Fenster A

    更新日期:2009-02-01 00:00:00

  • Precision of dosimetry-related measurements obtained on current multidetector computed tomography scanners.

    abstract:PURPOSE:Computed tomography (CT) intrascanner and interscanner variability has not been well characterized. Thus, the purpose of this study was to examine the within-run, between-run, and between-scanner precision of physical dosimetry-related measurements collected over the course of 1 yr on three different makes and ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3426000

    authors: Mathieu KB,McNitt-Gray MF,Zhang D,Kim HJ,Cody DD

    更新日期:2010-08-01 00:00:00

  • Technical Note: Cortical thickness and density estimation from clinical CT using a prior thickness-density relationship.

    abstract:PURPOSE:Cortical thickness and density are critical components in determining the strength of bony structures. Computed tomography (CT) is one possible modality for analyzing the cortex in 3D. In this paper, a model-based approach for measuring the cortical bone thickness and density from clinical CT images is proposed...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4944501

    authors: Humbert L,Hazrati Marangalou J,Del Río Barquero LM,van Lenthe GH,van Rietbergen B

    更新日期:2016-04-01 00:00:00

  • Prostatome: a combined anatomical and disease based MRI atlas of the prostate.

    abstract:PURPOSE:In this work, the authors introduce a novel framework, the anatomically constrained registration (AnCoR) scheme and apply it to create a fused anatomic-disease atlas of the prostate which the authors refer to as the prostatome. The prostatome combines a MRI based anatomic and a histology based disease atlas. St...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4881515

    authors: Rusu M,Bloch BN,Jaffe CC,Genega EM,Lenkinski RE,Rofsky NM,Feleppa E,Madabhushi A

    更新日期:2014-07-01 00:00:00

  • Reference dataset of users' photon beam modeling parameters for the Eclipse, Pinnacle, and RayStation treatment planning systems.

    abstract:PURPOSE:The aim of this work was to provide a novel description of how the radiotherapy community configures treatment planning system (TPS) radiation beam models for clinically used treatment machines. Here we describe the results of a survey of self-reported TPS beam modeling parameter values across different C-arm l...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13892

    authors: Glenn MC,Peterson CB,Followill DS,Howell RM,Pollard-Larkin JM,Kry SF

    更新日期:2020-01-01 00:00:00

  • An iterative technique to segment PET lesions using a Monte Carlo based mathematical model.

    abstract:PURPOSE:The need for an accurate lesion segmentation tool in 18FDG PET is a prerequisite for the estimation of lesion response to therapy, for radionuclide dosimetry, and for the application of 18FDG PET to radiotherapy planning. In this work, the authors have developed an iterative method based on a mathematical fit d...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3222732

    authors: Nehmeh SA,El-Zeftawy H,Greco C,Schwartz J,Erdi YE,Kirov A,Schmidtlein CR,Gyau AB,Larson SM,Humm JL

    更新日期:2009-10-01 00:00:00

  • AAPM Task Group 329: Reference dose specification for dose calculations: Dose-to-water or dose-to-muscle?

    abstract::Linac calibration is done in water, but patients are comprised primarily of soft tissue. Conceptually, and specified in NRG/RTOG trials, dose should be reported as dose-to-muscle to describe the dose to the patient. Historically, the dose-to-water of the linac calibration was often converted to dose-to-muscle for pati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13995

    authors: Kry SF,Feygelman V,Balter P,Knöös T,Charlie Ma CM,Snyder M,Tonner B,Vassiliev ON

    更新日期:2020-03-01 00:00:00

  • Computerized detection of lung nodules through radiomics.

    abstract:PURPOSE:Lung cancer is a major cause of cancer deaths, and the 5-year survival rate of stage IV lung cancer patients is only 2%. However, the 5-year survival rate of stage I lung cancer patients significantly increases to 50%. As such, spiral computed tomography (CT) scans are necessary to diagnose high-risk lung cance...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12331

    authors: Ma J,Zhou Z,Ren Y,Xiong J,Fu L,Wang Q,Zhao J

    更新日期:2017-08-01 00:00:00

  • Temporal stability assessment in shear wave elasticity images validated by deep learning neural network for chronic liver disease fibrosis stage assessment.

    abstract:PURPOSE:To automatically detect and isolate areas of low and high stiffness temporal stability in shear wave elastography (SWE) image sequences and define their impact in chronic liver disease (CLD) diagnosis improvement by means of clinical examination study and deep learning algorithm employing convolutional neural n...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13521

    authors: Gatos I,Tsantis S,Spiliopoulos S,Karnabatidis D,Theotokas I,Zoumpoulis P,Loupas T,Hazle JD,Kagadis GC

    更新日期:2019-05-01 00:00:00

  • A simple test phantom for stereotactic computed tomography.

    abstract::An easy-to-use phantom has been constructed for checking the accuracy of a stereotactic computed tomography localization system. This phantom has been used on a commercially available stereotactic radiosurgery system. With this system, the phantom reference point, whose location is established by means of a precision ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597034

    authors: Ekstrand KE,Olds WW,Branch CL

    更新日期:1993-03-01 00:00:00

  • Balancing dose and image registration accuracy for cone beam tomosynthesis (CBTS) for breast patient setup.

    abstract:PURPOSE:To balance dose reduction and image registration accuracy in breast setup imaging. In particular, the authors demonstrate the relationship between scan angle and dose delivery for cone beam tomosynthesis (CBTS) when employed for setup verification of breast cancer patients with surgical clips. METHODS:The dose...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3464716

    authors: Winey BA,Zygmanski P,Cormack RA,Lyatskaya Y

    更新日期:2010-08-01 00:00:00

  • Inter- and intra-software reproducibility of computed tomography lung density measurements.

    abstract:PURPOSE:Multiple commercial, open-source, and academic software tools exist for objective quantification of lung density in computed tomography (CT) images. The purpose of this study was to evaluate the intersoftware reproducibility of CT lung density measurements. METHODS:Computed tomography images from 50 participan...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14130

    authors: Kirby M,Hatt C,Obuchowski N,Humphries SM,Sieren J,Lynch DA,Fain SB,QIBA Lung Density Committee.

    更新日期:2020-07-01 00:00:00

  • Use of proximal operator graph solver for radiation therapy inverse treatment planning.

    abstract:PURPOSE:Most radiation therapy optimization problems can be formulated as an unconstrained problem and solved efficiently by quasi-Newton methods such as the Limited-memory Broyden-Fletcher-Goldfarb-Shanno (L-BFGS) algorithm. However, several next generation planning techniques such as total variation regularization- b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12165

    authors: Liu X,Pelizzari C,Belcher AH,Grelewicz Z,Wiersma RD

    更新日期:2017-04-01 00:00:00

  • Reliability of water proton chemical shift temperature calibration for focused ultrasound ablation therapy.

    abstract::Our purpose in this work was to assess the reliability of the calibration coefficient for magnetic resonance water proton chemical shift temperature mapping. Over a six month period, the calibration coefficient was measured 15 times in several different phantoms. A highly linear relationship between water proton chemi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598864

    authors: Wu T,Kendell KR,Felmlee JP,Lewis BD,Ehman RL

    更新日期:2000-01-01 00:00:00

  • WE-G-213CD-03: A Dual Complementary Verification Method for Dynamic Tumor Tracking on Vero SBRT.

    abstract:PURPOSE:to use complementary cine EPID and gimbals log file analysis for in-vivo tracking accuracy monitoring. METHODS:A clinical prototype of dynamic tracking (DT) was installed on the Vero SBRT system. This prototype version allowed tumor tracking by gimballed linac rotations using an internal-external correspondenc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736204

    authors: Poels K,Depuydt T,Verellen D,De Ridder M

    更新日期:2012-06-01 00:00:00

  • Monte Carlo study of ionization chamber magnetic field correction factors as a function of angle and beam quality.

    abstract:PURPOSE:To use EGSnrc Monte Carlo simulations for magnetic field dosimetry to determine optimal measurement orientations, calculate beam quality conversion factors for 32 cylindrical and three parallel-plate (PP) ion chambers, evaluate the beam quality and angular dependence of these factors, and examine the magnetic f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12716

    authors: Malkov VN,Rogers DWO

    更新日期:2018-02-01 00:00:00

  • A quality assurance program for monitor unit calculators.

    abstract::A quality assurance protocol has been developed to assess the relative accuracy of computerized monitor unit calculations. Results from this testing reveal that errors (defined as the difference between the computer results and those obtained using a standard formula with manual calculation) in monitor unit calculator...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596539

    authors: Dahl RA,McCullough EC,Mellenberg DE

    更新日期:1990-01-01 00:00:00

  • A real time dose monitoring and dose reconstruction tool for patient specific VMAT QA and delivery.

    abstract:PURPOSE:To develop a real time dose monitoring and dose reconstruction tool to identify and quantify sources of errors during patient specific volumetric modulated arc therapy (VMAT) delivery and quality assurance. METHODS:The authors develop a VMAT delivery monitor tool called linac data monitor that connects to the ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4764482

    authors: Tyagi N,Yang K,Gersten D,Yan D

    更新日期:2012-12-01 00:00:00

  • On the suitability of ultrathin detectors for absorbed dose assessment in the presence of high-density heterogeneities.

    abstract:PURPOSE:The aim of this study was to evaluate the suitability of several detectors for the determination of absorbed dose in bone. METHODS:Three types of ultrathin LiF-based thermoluminescent dosimeters (TLDs)-two LiF:Mg,Cu,P-based (MCP-Ns and TLD-2000F) and a (7)Li-enriched LiF:Mg,Ti-based (MTS-7s)-as well as EBT2 Ga...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4886760

    authors: Bueno M,Carrasco P,Jornet N,Muñoz-Montplet C,Duch MA

    更新日期:2014-08-01 00:00:00

  • Measuring uncertainty in dose delivered to the cochlea due to setup error during external beam treatment of patients with cancer of the head and neck.

    abstract:PURPOSE:To use Cone Beam CT scans obtained just prior to treatments of head and neck cancer patients to measure the setup error and cumulative dose uncertainty of the cochlea. METHODS:Data from 10 head and neck patients with 10 planning CTs and 52 Cone Beam CTs taken at time of treatment were used in this study. Patie...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4830427

    authors: Yan M,Lovelock D,Hunt M,Mechalakos J,Hu Y,Pham H,Jackson A

    更新日期:2013-12-01 00:00:00

  • A time-domain wavelet-based approach for fluorescence diffuse optical tomography.

    abstract:PURPOSE:In the context of fluorescence diffuse optical tomography, determining the optimal way to exploit the time-resolved information has been receiving much attention and different features of the time-resolved signals have been introduced. In this article, the authors revisit and generalize the notion of feature, c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3431571

    authors: Ducros N,Da Silva A,Dinten JM,Seelamantula CS,Unser M,Peyrin F

    更新日期:2010-06-01 00:00:00

  • Tomosynthesis-based localization of radioactive seeds in prostate brachytherapy.

    abstract::Accurately assessing the quality of prostate brachytherapy intraoperatively would be valuable for improved clinical outcome by ensuring the delivery of a prescribed tumoricidal radiation dose to the entire prostate gland. One necessary step towards this goal is the robust and rapid localization of implanted seeds. Sev...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1624755

    authors: Tutar IB,Managuli R,Shamdasani V,Cho PS,Pathak SD,Kim Y

    更新日期:2003-12-01 00:00:00

  • Numerical and experimental investigation of impacts of nonlinear scattering encapsulated microbubbles on Nakagami distribution.

    abstract:PURPOSE:The Nakagami statistical model and Nakagami shape parameter m have been widely used in linear tissue characterization and preliminarily characterized the envelope distributions of nonlinear encapsulated microbubbles (EMBs). However, the Nakagami distribution of nonlinear scattering EMBs lacked a systematical in...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13833

    authors: Wang D,Sang Y,Zhang X,Hu H,Lu S,Zhang Y,Fu C,Cloutier G,Wan M

    更新日期:2019-12-01 00:00:00

  • A general algorithm for calculation of recombination losses in ionization chambers exposed to ion beams.

    abstract:PURPOSE:Dosimetry with ionization chambers in clinical ion beams for radiation therapy requires correction for recombination effects. However, common radiation protocols discriminate between initial and general recombination and provide no universal correction method for the presence of both recombination types in ion ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4962483

    authors: Christensen JB,Tölli H,Bassler N

    更新日期:2016-10-01 00:00:00