WE-E-213CD-03: Inverse-Consistent Symmetric Registration of Inner Colon Surfaces Derived from Prone and Supine CT Colonography.

Abstract:

PURPOSE:Robust registration of prone and supine colonie surfaces acquired during CT colonography may lead to faster and more accurate detection of colorectal cancer and polyps. Any directional bias when registering one surface to the other could precipitate incorrect anatomical correspondence and engender reader error. Despite this, non-rigid registration methods are often implemented asymmetrically, which could negatively influence the registration. We aimed to reduce directional bias and so increase robustness by adapting a cylindrical registration algorithm to be both symmetric and inverse-consistent. METHODS:The registration task can be simplified by mapping both prone and supine colonie surfaces onto regular cylinders. Spatial correspondence can then be established in cylindrical space using the original surfaces' local shape indices. We implemented a symmetric formulation of the popular non-rigid B-spline image registration method in cylindrical space. A symmetric similarity measure computes the sum of squared differences between both cylindrical representations of prone-to-supine and supine-to-prone directions simultaneously. Inverse consistency of the transformation is enforced by adding an appropriately weighted penalty term to the optimisation function. RESULTS:We selected 8 CT colonography patient cases with marked variation in luminal distension and surface morphology. We randomly allocated 4 of these for tuning an optimal set of registration parameters and 4 for validation. The mean inverse-consistency error was reduced by 32% from 4.8mm to 3.2mm by the new symmetric formulation. The mean registration error improved from 8.2mm to 7.3mm for 330 manually chosen reference points on the 4 validation sets. CONCLUSIONS:A symmetric formulation of prone and supine surface registration improves the quality of registration. Information from both prone-to-supine and supine-to-prone directions helps enforce convergence towards a more accurate solution due to reduced directional bias. A more robust and accurate registration will facilitate interpretation of CT colonography and has the potential to improve existing computer-aided detection methods. The authors gratefully acknowledge financial support for this work from the NIHR program: “Imaging diagnosis of colorectal cancer: Interventions for efficient and acceptable diagnosis in symptomatic and screening populationsâ€.

journal_name

Med Phys

journal_title

Medical physics

authors

Roth H,McClelland J,Modat M,Hampshire T,Boone D,Hu M,Ourselin S,Halligan S,Hawkes D

doi

10.1118/1.4736159

subject

Has Abstract

pub_date

2012-06-01 00:00:00

pages

3959-3960

issue

6Part27

eissn

0094-2405

issn

2473-4209

journal_volume

39

pub_type

杂志文章
  • Noninvasive cardiac arrhythmia ablation with particle beams.

    abstract::Cardiac arrhythmias are a major health burden, associated with reduced quality of life and substantial morbidity and mortality. Current therapy includes moderately effective medication and catheter-based ablation of arrhythmogenic substrates in the heart. Catheter interventions frequently have to be repeated due to re...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1002/mp.12595

    authors: Graeff C,Bert C

    更新日期:2018-11-01 00:00:00

  • Introduction of heat map to fidelity assessment of compressed CT images.

    abstract:PURPOSE:This study aimed to introduce heat map, a graphical data presentation method widely used in gene expression experiments, to the presentation and interpretation of image fidelity assessment data of compressed computed tomography (CT) images. METHODS:The authors used actual assessment data that consisted of five...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3611046

    authors: Lee H,Kim B,Kim KJ,Seo J,Park S,Shin YG,Lee KH

    更新日期:2011-08-01 00:00:00

  • X-ray imaging technique for in vitro tissue composition measurements using saline/iodine displacement: technique optimization.

    abstract::An in vitro radiographic technique which uses saline/iodine displacement has been developed to study the thickness of bone-equivalent and soft-tissue-equivalent materials within atherosclerotic plaques in arterial specimens which have been cut open longitudinally and laid flat. Results concerning the optimization of t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597916

    authors: Moreau M,Holdsworth DW,Fenster A

    更新日期:1997-01-01 00:00:00

  • Accurate measurement of characteristic curves of II-TV digital systems by use of aluminum stepwedge technique.

    abstract::In order to determine accurately the relative x-ray intensities transmitted through the different steps of an aluminum stepwedge and incident on an image intensifier (II)-TV digital system, we used a 100-mm camera which was attached to the II output. The characteristic curves of an II-TV digital system, which relate t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595819

    authors: Fujita H,Doi K

    更新日期:1986-11-01 00:00:00

  • A 3D ultrasound scanning system for image guided liver interventions.

    abstract:PURPOSE:Two-dimensional ultrasound (2D US) imaging is commonly used for diagnostic and intraoperative guidance of interventional liver procedures; however, 2D US lacks volumetric information that may benefit interventional procedures. Over the past decade, three-dimensional ultrasound (3D US) has been developed to prov...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4824326

    authors: Neshat H,Cool DW,Barker K,Gardi L,Kakani N,Fenster A

    更新日期:2013-11-01 00:00:00

  • Low dose positron emission tomography emulation from decimated high statistics: A clinical validation study.

    abstract:PURPOSE:The fundamental nature of positron emission tomography (PET), as an event detection system, provides some flexibility for data handling, including retrospective data manipulation. The reorganization of acquisition data allows the emulation of new scans arising from identical radiotracer spatial distributions, b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13517

    authors: Schaefferkoetter J,Nai YH,Reilhac A,Townsend DW,Eriksson L,Conti M

    更新日期:2019-06-01 00:00:00

  • Octavius 4D characterization for flattened and flattening filter free rotational deliveries.

    abstract:PURPOSE:In this study the Octavius detector 729 ionization chamber (IC) array with the Octavius 4D phantom was characterized for flattening filter (FF) and flattening filter free (FFF) static and rotational beams. The device was assessed for verification with FF and FFF RapidArc treatment plans. METHODS:The response o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4817482

    authors: McGarry CK,O'Connell BF,Grattan MW,Agnew CE,Irvine DM,Hounsell AR

    更新日期:2013-09-01 00:00:00

  • Poster - Thur Eve - 77: Coordinate transformation from DICOM to DOSXYZnrc.

    abstract::DICOM format is the de facto standard for communications between therapeutic and diagnostic modalities. A plan generated by a treatment planning system (TPS) is often exported to DICOM format. BEAMnrc/DOSXYZnrc is a widely used Monte Carlo (MC) package for beam and dose simulations in radiotherapy. It has its own defi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740186

    authors: Zhan L,Jiang R,Osei EK

    更新日期:2012-07-01 00:00:00

  • Superiorization: an optimization heuristic for medical physics.

    abstract:PURPOSE:To describe and mathematically validate the superiorization methodology, which is a recently developed heuristic approach to optimization, and to discuss its applicability to medical physics problem formulations that specify the desired solution (of physically given or otherwise obtained constraints) by an opti...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4745566

    authors: Herman GT,Garduno E,Davidi R,Censor Y

    更新日期:2012-09-01 00:00:00

  • Automatic treatment planning based on three-dimensional dose distribution predicted from deep learning technique.

    abstract:PURPOSE:To develop an automated treatment planning strategy for external beam intensity-modulated radiation therapy (IMRT), including a deep learning-based three-dimensional (3D) dose prediction and a dose distribution-based plan generation algorithm. METHODS AND MATERIALS:A residual neural network-based deep learning...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13271

    authors: Fan J,Wang J,Chen Z,Hu C,Zhang Z,Hu W

    更新日期:2019-01-01 00:00:00

  • Dependence with air density of the response of the PTW SourceCheck ionization chamber for low energy brachytherapy sources.

    abstract:PURPOSE:Air-communicating well ionization chambers are commonly used to assess air kerma strength of sources used in brachytherapy. The signal produced is supposed to be proportional to the air density within the chamber and, therefore, a density-independent air kerma strength is obtained when the measurement is correc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4831757

    authors: Tornero-López AM,Guirado D,Perez-Calatayud J,Ruiz-Arrebola S,Simancas F,Gazdic-Santic M,Lallena AM

    更新日期:2013-12-01 00:00:00

  • Study of dosimetry consistency for kilovoltage x-ray beams.

    abstract::In this paper, the consistency of kilovoltage (tube potentials between 40 and 300 kV) x-ray beam dosimetry using the "in-air" method and the in-phantom measurement has been studied. The procedures for the measurement of the central-axis depth-dose curve, which serve as a link between the dose at the reference depth to...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598448

    authors: Ma CM,Li XA,Seuntjens JP

    更新日期:1998-12-01 00:00:00

  • TU-E-213AB-01: JMPSLC Has Morphed into Medical Physics Licensure and Regulatory Recognition Subcommittee.

    abstract::Based on direction from AAM Board of Directors, JMPLSC has redefined its scope and name. On November 4, 2011 the subcommittee renamed itself the Medical Physics Licensure and Regulatory Recognition Subcommittee. Its newly defined charge is to promote the protection of the public through the recognition of the professi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735947

    authors: Pizzutiello R

    更新日期:2012-06-01 00:00:00

  • Simplified skipped phase encoding and edge deghosting (SPEED) for imaging sparse objects with applications to MRA.

    abstract::The fast imaging method named skipped phase encoding and edge deghosting (SPEED) has been demonstrated to reduce scan time considerably with typical magnetic resonance imaging data. In this work, SPEED is simplified with improved efficiency to accelerate the scan of sparse objects; we refer to this method as S-SPEED. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2750966

    authors: Chang Z,Xiang QS

    更新日期:2007-08-01 00:00:00

  • Dosimetry of a thyroid uptake detected in seed migration survey following a patient's iodine-125 prostate implant and in vitro measurements of intentional seed leakages.

    abstract::As a quality control procedure, a post-implant seed migration survey has been accomplished on 340 prostate cancer patients since November 2001. Pulmonary seed embolization and intracardiac seed embolization have been detected. A case of thyroid uptake due to leaking iodine-125 (I-125) sources was also seized. In order...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2207319

    authors: Chen QS,Russell JL Jr,Macklis RR,Weinhous MS,Blair HF

    更新日期:2006-07-01 00:00:00

  • Development and validation of a measurement-based source model for kilovoltage cone-beam CT Monte Carlo dosimetry simulations.

    abstract:PURPOSE:The purpose of this study is to adapt an equivalent source model originally developed for conventional CT Monte Carlo dose quantification to the radiation oncology context and validate its application for evaluating concomitant dose incurred by a kilovoltage (kV) cone-beam CT (CBCT) system integrated into a lin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4823795

    authors: McMillan K,McNitt-Gray M,Ruan D

    更新日期:2013-11-01 00:00:00

  • Measurement of LINAC 90 degrees head leakage radiation TVL values.

    abstract::One of the key components in modern LINAC room shielding design is the amount of 90 degrees head leakage radiation levels. With the general clinical acceptance of intensity-modulated radiation therapy (IMRT) technique, accurate knowledge of this quantity has become even more important. Measurement of 90 degrees head l...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2335489

    authors: Li Z,Mutic S,Low D

    更新日期:2006-09-01 00:00:00

  • Clinical Target Volume Segmentation for Stomach Cancer by Stochastic Width Deep Neural Network.

    abstract:PURPOSE:Precise segmentation of clinical target volume (CTV) is the key to stomach cancer radiotherapy. We proposed a novel stochastic width - deep neural network (SW-DNN) for better automatically contouring stomach CTV METHODS: SW-DNN was an end-to-end approach, of which the core component was a novel SW mechanism tha...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14733

    authors: Xu L,Hu J,Song Y,Bai S,Yi Z

    更新日期:2021-01-27 00:00:00

  • Cone-beam CT-derived relative stopping power map generation via deep learning for proton radiotherapy.

    abstract:PURPOSE:In intensity-modulated proton therapy (IMPT), protons are used to deliver highly conformal dose distributions, targeting tumors, and sparing organs-at-risk. However, due to uncertainties in both patient setup and relative stopping power (RSP) calculation, margins are added to the treatment volume during treatme...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14347

    authors: Harms J,Lei Y,Wang T,McDonald M,Ghavidel B,Stokes W,Curran WJ,Zhou J,Liu T,Yang X

    更新日期:2020-09-01 00:00:00

  • Technical Note: Impact of the geometry dependence of the ion chamber detector response function on a convolution-based method to address the volume averaging effect.

    abstract:PURPOSE:To investigate the geometry dependence of the detector response function (DRF) of three commonly used scanning ionization chambers and its impact on a convolution-based method to address the volume averaging effect (VAE). METHODS:A convolution-based approach has been proposed recently to address the ionization...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4944783

    authors: Barraclough B,Li JG,Lebron S,Fan Q,Liu C,Yan G

    更新日期:2016-05-01 00:00:00

  • Accelerated barrier optimization compressed sensing (ABOCS) reconstruction for cone-beam CT: phantom studies.

    abstract:PURPOSE:Recent advances in compressed sensing (CS) enable accurate CT image reconstruction from highly undersampled and noisy projection measurements, due to the sparsifiable feature of most CT images using total variation (TV). These novel reconstruction methods have demonstrated advantages in clinical applications wh...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4729837

    authors: Niu T,Zhu L

    更新日期:2012-07-01 00:00:00

  • Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy.

    abstract::The objective of this work is to assess the suitability and performance of a new dosimeter system with a novel geometry for the quality assurance (QA) of volumetric modulated arc therapy (VMAT). The new dosimeter system consists of a hollow cylinder (15 and 25 cm inner and outer diameters) with 124 diodes embedded in ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3117563

    authors: Létourneau D,Publicover J,Kozelka J,Moseley DJ,Jaffray DA

    更新日期:2009-05-01 00:00:00

  • SU-E-T-389: Accuracy of a VMAT Planning System for Head and Neck Radiotherapy.

    abstract:PURPOSE:To determine the accuracy of VMAT treatment planning and delivery for patients undergoing radiotherapy in the head and neck. METHOD AND MATERIALS:A dosimetric study of a typical head and neck treatment plan has been carried out using Chamber, film and TLD's placed inside an anthropomorphic phantom. Lateral and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735478

    authors: Aldaais E,Tedeschi D,Gebreamlak W,Shieder T,Alkhatib H

    更新日期:2012-06-01 00:00:00

  • Noninvasive x-ray tube current measurement.

    abstract::A clamp-on current probe utilizing the Hall effect was used to determine x-ray tube current. This noninvasive technique was compared to two other methods of mA measurement: the Machlett Dynalyzer and the mR/mAs linearity method. Three diagnostic x-ray units were used in the comparison; two modern three-phase rooms and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596080

    authors: Atherton JV,Nickoloff EL

    更新日期:1987-03-01 00:00:00

  • Physical models, cross sections, and numerical approximations used in MCNP and GEANT4 Monte Carlo codes for photon and electron absorbed fraction calculation.

    abstract:PURPOSE:Radiopharmaceutical applications in nuclear medicine require a detailed dosimetry estimate of the radiation energy delivered to the human tissues. Over the past years, several publications addressed the problem of internal dose estimate in volumes of several sizes considering photon and electron sources. Most o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3242304

    authors: Yoriyaz H,Moralles M,Siqueira Pde T,Guimarães Cda C,Cintra FB,dos Santos A

    更新日期:2009-11-01 00:00:00

  • Potential of high-Z contrast agents in clinical contrast-enhanced computed tomography.

    abstract:PURPOSE:Currently, only iodine- and barium-based contrast media (CM) are used in clinical contrast-enhanced computed tomography (CE-CT). High-Z metals would produce a higher contrast at equal mass density for the x-ray spectra used in clinical CT. Using such materials might allow for significant dose reductions in CE-C...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3658738

    authors: Nowak T,Hupfer M,Brauweiler R,Eisa F,Kalender WA

    更新日期:2011-12-01 00:00:00

  • Small SRS photon field profile dosimetry performed using a PinPoint air ion chamber, a diamond detector, a novel silicon-diode array (DOSI), and polymer gel dosimetry. Analysis and intercomparison.

    abstract::Small photon fields are increasingly used in modern radiotherapy and especially in IMRT and SRS/SRT treatments. The uncertainties related to small field profile measurements can introduce significant systematic errors to the overall treatment process. These measurements are challenging mainly due to the absence of cha...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2977829

    authors: Pappas E,Maris TG,Zacharopoulou F,Papadakis A,Manolopoulos S,Green S,Wojnecki C

    更新日期:2008-10-01 00:00:00

  • Patch-based generation of a pseudo CT from conventional MRI sequences for MRI-only radiotherapy of the brain.

    abstract:PURPOSE:In radiotherapy (RT) based on magnetic resonance imaging (MRI) as the only modality, the information on electron density must be derived from the MRI scan by creating a so-called pseudo computed tomography (pCT). This is a nontrivial task, since the voxel-intensities in an MRI scan are not uniquely related to e...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4914158

    authors: Andreasen D,Van Leemput K,Hansen RH,Andersen JA,Edmund JM

    更新日期:2015-04-01 00:00:00

  • Statistical variability and confidence intervals for planar dose QA pass rates.

    abstract:PURPOSE:The most common metric for comparing measured to calculated dose, such as for pretreatment quality assurance of intensity-modulated photon fields, is a pass rate (%) generated using percent difference (%Diff), distance-to-agreement (DTA), or some combination of the two (e.g., gamma evaluation). For many dosimet...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3651695

    authors: Bailey DW,Nelms BE,Attwood K,Kumaraswamy L,Podgorsak MB

    更新日期:2011-11-01 00:00:00

  • Quantitative classification of breast tumors in digitized mammograms.

    abstract::The goal of this study was to develop a technique to distinguish benign and malignant breast lesions in secondarily digitized mammograms. A set of 51 mammograms (two views/patient) containing lesions of known pathology were evaluated using six different morphological descriptors: circularity, mu R/sigma R (where mu R ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597707

    authors: Pohlman S,Powell KA,Obuchowski NA,Chilcote WA,Grundfest-Broniatowski S

    更新日期:1996-08-01 00:00:00