Patch-based generation of a pseudo CT from conventional MRI sequences for MRI-only radiotherapy of the brain.

Abstract:

PURPOSE:In radiotherapy (RT) based on magnetic resonance imaging (MRI) as the only modality, the information on electron density must be derived from the MRI scan by creating a so-called pseudo computed tomography (pCT). This is a nontrivial task, since the voxel-intensities in an MRI scan are not uniquely related to electron density. To solve the task, voxel-based or atlas-based models have typically been used. The voxel-based models require a specialized dual ultrashort echo time MRI sequence for bone visualization and the atlas-based models require deformable registrations of conventional MRI scans. In this study, we investigate the potential of a patch-based method for creating a pCT based on conventional T1-weighted MRI scans without using deformable registrations. We compare this method against two state-of-the-art methods within the voxel-based and atlas-based categories. METHODS:The data consisted of CT and MRI scans of five cranial RT patients. To compare the performance of the different methods, a nested cross validation was done to find optimal model parameters for all the methods. Voxel-wise and geometric evaluations of the pCTs were done. Furthermore, a radiologic evaluation based on water equivalent path lengths was carried out, comparing the upper hemisphere of the head in the pCT and the real CT. Finally, the dosimetric accuracy was tested and compared for a photon treatment plan. RESULTS:The pCTs produced with the patch-based method had the best voxel-wise, geometric, and radiologic agreement with the real CT, closely followed by the atlas-based method. In terms of the dosimetric accuracy, the patch-based method had average deviations of less than 0.5% in measures related to target coverage. CONCLUSIONS:We showed that a patch-based method could generate an accurate pCT based on conventional T1-weighted MRI sequences and without deformable registrations. In our evaluations, the method performed better than existing voxel-based and atlas-based methods and showed a promising potential for RT of the brain based only on MRI.

journal_name

Med Phys

journal_title

Medical physics

authors

Andreasen D,Van Leemput K,Hansen RH,Andersen JA,Edmund JM

doi

10.1118/1.4914158

subject

Has Abstract

pub_date

2015-04-01 00:00:00

pages

1596-605

issue

4

eissn

0094-2405

issn

2473-4209

journal_volume

42

pub_type

杂志文章
  • Dosimetric characteristics of the Leipzig surface applicators used in the high dose rate brachy radiotherapy.

    abstract::The nucletron Leipzig applicator is designed for (HDR) 192Ir brachy radiotherapy of surface lesions. The dosimetric characteristics of this applicator were investigated using simulation method based on Monte Carlo N-particle (MCNP) code and phantom measurements. The simulation method was validated by comparing calcula...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1812609

    authors: Niu H,Hsi WC,Chu JC,Kirk MC,Kouwenhoven E

    更新日期:2004-12-01 00:00:00

  • Efficient generation of a magnetic field-free line.

    abstract:PURPOSE:Signal encoding in magnetic particle imaging (MPI) is achieved by moving a field-free point (FFP) through the region of interest. One way to increase the sensitivity of the method is to scan the region of interest with a field-free line (FFL) instead of the FFP. Recently, the first feasible FFL coil setup was i...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1118/1.3447726

    authors: Knopp T,Erbe M,Biederer S,Sattel TF,Buzug TM

    更新日期:2010-07-01 00:00:00

  • Technical and dosimetric realization of in vivo x-ray microbeam irradiations at the Munich Compact Light Source.

    abstract:PURPOSE:X-ray microbeam radiation therapy is a preclinical concept for tumor treatment promising tissue sparing and enhanced tumor control. With its spatially separated, periodic micrometer-sized pattern, this method requires a high dose rate and a collimated beam typically available at large synchrotron radiation faci...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14433

    authors: Burger K,Urban T,Dombrowsky AC,Dierolf M,Günther B,Bartzsch S,Achterhold K,Combs SE,Schmid TE,Wilkens JJ,Pfeiffer F

    更新日期:2020-10-01 00:00:00

  • In vivo functional chronic imaging of a small animal model using optical-resolution photoacoustic microscopy.

    abstract::Optical-resolution photoacoustic microscopy (OR-PAM) has been validated as a valuable tool for label-free volumetric microvascular imaging. More importantly, the advantages of noninvasiveness and measurement consistency suggest the use of OR-PAM for chronic imaging of intact microcirculation. Here, such chronic imagin...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1118/1.3137572

    authors: Hu S,Maslov K,Wang LV

    更新日期:2009-06-01 00:00:00

  • Tolerance limits and methodologies for IMRT measurement-based verification QA: Recommendations of AAPM Task Group No. 218.

    abstract:PURPOSE:Patient-specific IMRT QA measurements are important components of processes designed to identify discrepancies between calculated and delivered radiation doses. Discrepancy tolerance limits are neither well defined nor consistently applied across centers. The AAPM TG-218 report provides a comprehensive review a...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1002/mp.12810

    authors: Miften M,Olch A,Mihailidis D,Moran J,Pawlicki T,Molineu A,Li H,Wijesooriya K,Shi J,Xia P,Papanikolaou N,Low DA

    更新日期:2018-04-01 00:00:00

  • An investigation on the use of removal-diffusion theory for BNCT treatment planning: a method for determining proper removal-diffusion parameters.

    abstract::This paper outlines a method for determining proper removal-diffusion parameters to be used in removal-diffusion theory calculations for the purpose of BNCT treatment planning. Additionally, this paper demonstrates that, given the proper choice of removal-diffusion parameters, removal-diffusion theory may provide an a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1386424

    authors: Albertson BJ,Blue TE,Niemkiewicz J

    更新日期:2001-09-01 00:00:00

  • Mixed model phase evolution for correction of magnetic field inhomogeneity effects in 3D quantitative gradient echo-based MRI.

    abstract:PURPOSE:In 3D gradient echo magnetic resonance imaging (MRI), strong field gradients B0macro are visually observed at air/tissue interfaces. At low spatial resolution in particular, the respective field gradients lead to an apparent increase in intravoxel dephasing, and subsequently, to signal loss or inaccurate R2* es...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12318

    authors: Fatnassi C,Boucenna R,Zaidi H

    更新日期:2017-07-01 00:00:00

  • Reverse mapping of normal tissue complication probabilities onto dose volume histogram space: the problem of randomness of the dose volume histogram sampling.

    abstract::A very important issue in contemporary inverse treatment radiotherapy planning is the specification of proper dose-volume constraints limiting the treatment planning algorithm from delivering high doses to the normal tissue surrounding the tumor. Recently we have proposed a method called reverse mapping of normal tiss...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2198307

    authors: Markov K,Schinkel C,Stavreva N,Stavrev P,Weldon M,Fallone BG

    更新日期:2006-09-01 00:00:00

  • Selective enhancement filters for nodules, vessels, and airway walls in two- and three-dimensional CT scans.

    abstract::Computer-aided diagnostic (CAD) schemes have been developed to assist radiologists in the early detection of lung cancer in radiographs and computed tomography (CT) images. In order to improve sensitivity for nodule detection, many researchers have employed a filter as a preprocessing step for enhancement of nodules. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1581411

    authors: Li Q,Sone S,Doi K

    更新日期:2003-08-01 00:00:00

  • Designing an optical distance indicator for a radiation therapy accelerator.

    abstract::The computational aspects of the design of an optical distance indicator (ODI) for use with a radiation therapy accelerator are discussed. The specifics of the optical and mechanical design of an ODI for use with a superconducting cyclotron used for fast neutron therapy are presented. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598510

    authors: Maughan RL

    更新日期:1999-02-01 00:00:00

  • Fast time-of-flight camera based surface registration for radiotherapy patient positioning.

    abstract:PURPOSE:This work introduces a rigid registration framework for patient positioning in radiotherapy, based on real-time surface acquisition by a time-of-flight (ToF) camera. Dynamic properties of the system are also investigated for future gating/tracking strategies. METHODS:A novel preregistration algorithm, based on...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3664006

    authors: Placht S,Stancanello J,Schaller C,Balda M,Angelopoulou E

    更新日期:2012-01-01 00:00:00

  • Suitability of laser stimulated TLD arrays as patient dose monitors in high dose x-ray imaging.

    abstract::Skin entrance doses of patients undergoing interventional x-ray procedures are capable of causing skin damage and should be monitored routinely. Single TLD chips are not suitable because the location of maximum skin exposure cannot be predicted. Most photographic films are too sensitive at diagnostic x-ray energies fo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597973

    authors: Geise RA,Schueler BA,Lien W,Jones SC

    更新日期:1997-10-01 00:00:00

  • Image noise and dose performance across a clinical population: Patient size adaptation as a metric of CT performance.

    abstract:PURPOSE:Modern CT systems adjust X-ray flux accommodating for patient size to achieve certain image noise values. The effectiveness of this adaptation is an important aspect of CT performance and should ideally be characterized in the context of real patient cases. The objective of this study was to characterize CT per...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12172

    authors: Ria F,Wilson JM,Zhang Y,Samei E

    更新日期:2017-06-01 00:00:00

  • Accuracy of EGSnrc calculations at 60Co energies for the response of ion chambers configured with various wall materials and cavity dimensions.

    abstract::In this investigation, five experimental data sets are used to evaluate the ability of the EGSnrc Monte Carlo code to calculate the change in chamber response associated with changes in wall material and cavity dimension at 60Co energies. Calculations of the ratios of response per unit mass of air as a function of cav...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3013701

    authors: La Russa DJ,Rogers DW

    更新日期:2008-12-01 00:00:00

  • Dose in the buildup region outside the primary beam.

    abstract::The dose received in the buildup region outside the primary beam has been measured for 60Co gamma rays and 6- and 18-MV X rays. The variation of this dose with field size and depth was evaluated. The effect of blocking trays and the importance of their design was determined. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595508

    authors: Horton JL

    更新日期:1984-05-01 00:00:00

  • Use of the fast Hartley transform for three-dimensional dose calculation in radionuclide therapy.

    abstract::Effective radioimmunotherapy may depend on a priori knowledge of the radiation absorbed dose distribution obtained by trace imaging activities administered to a patient before treatment. A new, fast, and effective treatment planning approach is developed to deal with a heterogeneous activity distribution. Calculation ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598422

    authors: Erdi AK,Yorke ED,Loew MH,Erdi YE,Sarfaraz M,Wessels BW

    更新日期:1998-11-01 00:00:00

  • SU-E-J-63: Feasibility Study of Proton Digital Tomosynthesis in Proton Beam Therapy.

    abstract:PURPOSE:We investigated the feasibility of proton tomosynthesis as daily positioning of patients and compared the results with photon tomosynthesis as an alternative to conventional portal imaging or on-board cone-beam computed tomography. METHODS:Dedicated photon-like proton beam using the passively scattered proton ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734898

    authors: Min B,Kwak J,Lee J,Cho S,Park S,Yoo S,Chung K,Cho S,Lim Y,Shin D,Lee S,Kim J

    更新日期:2012-06-01 00:00:00

  • Anthropomorphic 1H MRS head phantom.

    abstract::An anthropomorphic 1H MRS head phantom has been developed which mimics the in vivo structure, metabolite concentrations, and relaxation times (for both water and metabolites) of human brain tissue. Different brain regions and two tumor types, fluid-containing ventricles, and air-filled sinus, and subcutaneous fat are ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598306

    authors: Rice JR,Milbrandt RH,Madsen EL,Frank GR,Boote EJ,Blechinger JC

    更新日期:1998-07-01 00:00:00

  • Projections onto the Pareto surface in multicriteria radiation therapy optimization.

    abstract:PURPOSE:To eliminate or reduce the error to Pareto optimality that arises in Pareto surface navigation when the Pareto surface is approximated by a small number of plans. METHODS:The authors propose to project the navigated plan onto the Pareto surface as a postprocessing step to the navigation. The projection attempt...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4930252

    authors: Bokrantz R,Miettinen K

    更新日期:2015-10-01 00:00:00

  • Automated registration of diagnostic to prediagnostic x-ray mammograms: evaluation and comparison to radiologists' accuracy.

    abstract:PURPOSE:To compare and evaluate intensity-based registration methods for computation of serial x-ray mammogram correspondence. METHODS:X-ray mammograms were simulated from MRIs of 20 women using finite element methods for modeling breast compressions and employing a MRI/x-ray appearance change model. The parameter con...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3457470

    authors: Pinto Pereira SM,Hipwell JH,McCormack VA,Tanner C,Moss SM,Wilkinson LS,Khoo LA,Pagliari C,Skippage PL,Kliger CJ,Hawkes DJ,Silva IM

    更新日期:2010-09-01 00:00:00

  • Optimization of the dose delivery in a few field techniques using radiobiological objective functions.

    abstract::A method for finding optimal primary fluence profiles for multiple field external beam radiation therapy techniques has been developed using a radiobiologically based objective function that quantifies the probability of achieving complication-free tumor control, P+. The objective function P+ has the valuable property...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596971

    authors: Södertröm S,Brahme A

    更新日期:1993-07-01 00:00:00

  • Interleaf leakage for 5 and 10 mm dynamic multileaf collimation systems incorporating patient motion.

    abstract::Use of dynamic multileaf collimation (DMLC) for intensity modulated radiation therapy (IMRT) is accelerating. Delivery systems have the ailment of interleaf leakage (IL). This is compounded by the inefficiency of IMRT delivery, estimated to be a factor of 5 for DMLC. With IL on the order of 4%, it is possible to deliv...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1388216

    authors: Klein EE,Low DA

    更新日期:2001-08-01 00:00:00

  • Displacement and strain estimation for evaluation of arterial wall stiffness using a familial hypercholesterolemia swine model of atherosclerosis.

    abstract:PURPOSE:To track variations in the deformation of the arterial wall noninvasively by estimating the accumulated displacement and strain over a cardiac cycle may provide useful indicators of vascular health. METHODS:In this paper, we propose an approach to track a region of interest (ROI) locally and estimate arterial ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4722746

    authors: Ge W,Krueger CG,Weichmann A,Shanmuganayagam D,Varghese T

    更新日期:2012-07-01 00:00:00

  • Measured and calculated K-fluorescence effects on the MTF of an amorphous-selenium based CCD x-ray detector.

    abstract:PURPOSE:Theoretical reasoning suggests that direct conversion digital x-ray detectors based upon photoconductive amorphous-selenium (a-Se) could attain very high values of the MTF (modulation transfer function) at spatial frequencies well beyond 20 cycles mm(-1). One of the fundamental factors affecting resolution loss...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3673957

    authors: Hunter DM,Belev G,Kasap S,Yaffe MJ

    更新日期:2012-02-01 00:00:00

  • On the uncertainties in effective dose estimates of adult CT head scans.

    abstract::Estimates of the effective dose to adult patients from computed tomography (CT) head scanning can be calculated using a number of different methods. These estimates can be used for a variety of purposes, such as improving scanning protocols, comparing different CT imaging centers, and weighing the benefits of the scan...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2952359

    authors: Gregory KJ,Bibbo G,Pattison JE

    更新日期:2008-08-01 00:00:00

  • Differentiation between diamagnetic and paramagnetic cerebral lesions based on magnetic susceptibility mapping.

    abstract:PURPOSE:Identification of calcifications and hemorrhages is essential for the etiological diagnosis of cerebral lesions. The purpose of this work was to develop a robust method for characterization of para- and diamagnetic intracerebral lesions based on clinical gradient-echo magnetic resonance phase data acquired at 1...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3481505

    authors: Schweser F,Deistung A,Lehr BW,Reichenbach JR

    更新日期:2010-10-01 00:00:00

  • Localization of cochlear implant electrodes in radiographs.

    abstract::Multielectrode cochlear implantation is the most effective treatment for profound sensorineural hearing loss. In vivo three-dimensional 3-D localization of cochlear implant electrodes is important for modeling of the electrical field in the cochlea, design of electrode arrays, and may improve speech processor programm...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598940

    authors: Yang S,Wang G,Skinner MW,Rubinstein JT,Vannier MW

    更新日期:2000-04-01 00:00:00

  • On-board SPECT for localizing functional targets: a simulation study.

    abstract::Single photon emission computed tomography (SPECT) was investigated for imaging on-board radiation therapy machines in order to localize functional and molecular targets. A computer-simulated female NCAT phantom was positioned supine on a flat-top treatment couch. Twenty tumor locations were defined in the upper torso...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3113902

    authors: Roper J,Bowsher J,Yin FF

    更新日期:2009-05-01 00:00:00

  • SU-E-T-389: Accuracy of a VMAT Planning System for Head and Neck Radiotherapy.

    abstract:PURPOSE:To determine the accuracy of VMAT treatment planning and delivery for patients undergoing radiotherapy in the head and neck. METHOD AND MATERIALS:A dosimetric study of a typical head and neck treatment plan has been carried out using Chamber, film and TLD's placed inside an anthropomorphic phantom. Lateral and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735478

    authors: Aldaais E,Tedeschi D,Gebreamlak W,Shieder T,Alkhatib H

    更新日期:2012-06-01 00:00:00

  • Stereotactic mammography imaging combined with 3D US imaging for image guided breast biopsy.

    abstract::Stereotactic X-ray mammography (SM) and ultrasound (US) guidance are both commonly used for breast biopsy. While SM provides three-dimensional (3D) targeting information and US provides real-time guidance, both have limitations. SM is a long and uncomfortable procedure and the US guided procedure is inherently two dim...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2794175

    authors: Surry KJ,Mills GR,Bevan K,Downey DB,Fenster A

    更新日期:2007-11-01 00:00:00