Accelerated barrier optimization compressed sensing (ABOCS) reconstruction for cone-beam CT: phantom studies.

Abstract:

PURPOSE:Recent advances in compressed sensing (CS) enable accurate CT image reconstruction from highly undersampled and noisy projection measurements, due to the sparsifiable feature of most CT images using total variation (TV). These novel reconstruction methods have demonstrated advantages in clinical applications where radiation dose reduction is critical, such as onboard cone-beam CT (CBCT) imaging in radiation therapy. The image reconstruction using CS is formulated as either a constrained problem to minimize the TV objective within a small and fixed data fidelity error, or an unconstrained problem to minimize the data fidelity error with TV regularization. However, the conventional solutions to the above two formulations are either computationally inefficient or involved with inconsistent regularization parameter tuning, which significantly limit the clinical use of CS-based iterative reconstruction. In this paper, we propose an optimization algorithm for CS reconstruction which overcomes the above two drawbacks. METHODS:The data fidelity tolerance of CS reconstruction can be well estimated based on the measured data, as most of the projection errors are from Poisson noise after effective data correction for scatter and beam-hardening effects. We therefore adopt the TV optimization framework with a data fidelity constraint. To accelerate the convergence, we first convert such a constrained optimization using a logarithmic barrier method into a form similar to that of the conventional TV regularization based reconstruction but with an automatically adjusted penalty weight. The problem is then solved efficiently by gradient projection with an adaptive Barzilai-Borwein step-size selection scheme. The proposed algorithm is referred to as accelerated barrier optimization for CS (ABOCS), and evaluated using both digital and physical phantom studies. RESULTS:ABOCS directly estimates the data fidelity tolerance from the raw projection data. Therefore, as demonstrated in both digital Shepp-Logan and physical head phantom studies, consistent reconstruction performances are achieved using the same algorithm parameters on scans with different noise levels and∕or on different objects. On the contrary, the penalty weight in a TV regularization based method needs to be fine-tuned in a large range (up to seven times) to maintain the reconstructed image quality. The improvement of ABOCS on computational efficiency is demonstrated in the comparisons with adaptive-steepest-descent-projection-onto-convex-sets (ASD-POCS), an existing CS reconstruction algorithm also using constrained optimization. ASD-POCS alternatively minimizes the TV objective using adaptive steepest descent (ASD) and the data fidelity error using projection onto convex sets (POCS). For similar image qualities of the Shepp-Logan phantom, ABOCS requires less computation time than ASD-POCS in MATLAB by more than one order of magnitude. CONCLUSIONS:We propose ABOCS for CBCT reconstruction. As compared to other published CS-based algorithms, our method has attractive features of fast convergence and consistent parameter settings for different datasets. These advantages have been demonstrated on phantom studies.

journal_name

Med Phys

journal_title

Medical physics

authors

Niu T,Zhu L

doi

10.1118/1.4729837

subject

Has Abstract

pub_date

2012-07-01 00:00:00

pages

4588-98

issue

7

eissn

0094-2405

issn

2473-4209

journal_volume

39

pub_type

杂志文章
  • Patient specific optimization of the relation between CT-hounsfield units and proton stopping power with proton radiography.

    abstract::The purpose of this work is to show the feasibility of using in vivo proton radiography of a radiotherapy patient for the patient individual optimization of the calibration from CT-Hounsfield units to relative proton stopping power. Water equivalent tissue (WET) calibrated proton radiographs of a dog patient treated f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1833041

    authors: Schneider U,Pemler P,Besserer J,Pedroni E,Lomax A,Kaser-Hotz B

    更新日期:2005-01-01 00:00:00

  • Clinical evaluation of a commercial orthopedic metal artifact reduction tool for CT simulations in radiation therapy.

    abstract:PURPOSE:Severe artifacts in kilovoltage-CT simulation images caused by large metallic implants can significantly degrade the conspicuity and apparent CT Hounsfield number of targets and anatomic structures, jeopardize the confidence of anatomical segmentation, and introduce inaccuracies into the radiation therapy treat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4762814

    authors: Li H,Noel C,Chen H,Harold Li H,Low D,Moore K,Klahr P,Michalski J,Gay HA,Thorstad W,Mutic S

    更新日期:2012-12-01 00:00:00

  • Detectability of perfusion defect in five-dimensional gated-dynamic cardiac SPECT images.

    abstract:PURPOSE:In previous work, the authors developed and demonstrated the concept of an image reconstruction procedure aimed to unify gated and dynamic nuclear cardiac imaging, which the authors have termed five-dimensional (5D) SPECT. Gated imaging permits the clinician to evaluate wall motion and, through the use of stres...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3481507

    authors: Niu X,Yang Y,King MA,Wernick MN

    更新日期:2010-09-01 00:00:00

  • Accuracy of EGSnrc calculations at 60Co energies for the response of ion chambers configured with various wall materials and cavity dimensions.

    abstract::In this investigation, five experimental data sets are used to evaluate the ability of the EGSnrc Monte Carlo code to calculate the change in chamber response associated with changes in wall material and cavity dimension at 60Co energies. Calculations of the ratios of response per unit mass of air as a function of cav...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3013701

    authors: La Russa DJ,Rogers DW

    更新日期:2008-12-01 00:00:00

  • A dosimetry review system for cooperative group research.

    abstract::The validity of conclusions drawn from multi-institutional radiotherapy studies is dependent upon the degree to which participating hospitals adhere to study requirements. A major effort undertaken by the Quality Assurance Review Center (QARC) assesses whether or not patient data which are deemed evaluable actually co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595221

    authors: Reinstein LE,McShan D,Glicksman AS

    更新日期:1982-03-01 00:00:00

  • Monte Carlo dosimetry for 103Pd, 125I, and 131Cs ocular brachytherapy with various plaque models using an eye phantom.

    abstract:PURPOSE:To investigate dosimetry for ocular brachytherapy for a range of eye plaque models containing(103)Pd, (125)I, or (131)Cs seeds with model-based dose calculations. METHODS:Five representative plaque models are developed based on a literature review and are compared to the standardized COMS plaque, including pla...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4864474

    authors: Lesperance M,Martinov M,Thomson RM

    更新日期:2014-03-01 00:00:00

  • Long term variation in beam symmetry as a function of gantry angle for a computer-controlled linear accelerator.

    abstract::Testing computer-controlled linear accelerators for patient safety and proper patient dose delivery requires that certain beam characteristics be monitored over an extended period of time. Computer-controlled conformal radiation therapy using asymmetric collimator jaw settings necessitates stable symmetric treatment b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596363

    authors: Loyd MD,Lane RG,Laxton J,Chow CH,Rosen II

    更新日期:1989-07-01 00:00:00

  • SU-E-J-157: Simulation and Design of a Real-Time 6D Head Motion Compensation Platform Based on a Stewart Platform Approach.

    abstract:PURPOSE:Real-time sub-millimeter head motion compensation during frameless SRS delivery has the potential to achieve the accuracy of frame-based SRS while being significantly less invasive. Previously, we demonstrated real-time 6D head motion monitoring using an optical camera, however, at the time we were limited to o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734995

    authors: Belcher AH,Wiersma RD

    更新日期:2012-06-01 00:00:00

  • SAPHIRE (scintillator avalanche photoconductor with high resolution emitter readout) for low dose x-ray imaging: spatial resolution.

    abstract::An indirect flat panel imager (FPI) with programmable avalanche gain and field emitter array (FEA) readout is being investigated for low-dose and high resolution x-ray imaging. It is made by optically coupling a structured x-ray scintillator, e.g., thallium (Tl) doped cesium iodide (CsI), to an amorphous selenium (a-S...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2937652

    authors: Li D,Zhao W

    更新日期:2008-07-01 00:00:00

  • SU-E-T-462: Calculation of Prescribed Dose for Permanent Implant with Cs-131 Using LQ Equation including Resensitization.

    abstract:PURPOSE:To develop a new biological equivalent dose (BED) formulism that includes repair, repopulation and resensitization (redistribution and reoxygenation), and can be used to calculate prescribed dose for permanent implant with Cs-131. METHODS:Because of lack of sufficient clinical data, the prescribed dose with ne...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735551

    authors: Luo W,Aryal P,Randall M

    更新日期:2012-06-01 00:00:00

  • Poster - Thur Eve - 66: A planning comparison between RapidArc and intensity modulated radiotherapy for head and neck cancer.

    abstract::Volumetric modulated arc therapy (VMAT) has recently been used to improve the dose distribution and efficiency of treatment delivery over the standard intensity-modulated radiotherapy (IMRT) technique. This study compares the dosimetry between RapidArc plan and standard IMRT plan for head and neck cancer. Three head a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740174

    authors: Jiang R,Fleck A,Schaly B,Charland P,Zhan L,Alliet K,Rachakonda R,Osei E

    更新日期:2012-07-01 00:00:00

  • Image segmentation with a novel regularized composite shape prior based on surrogate study.

    abstract:PURPOSE:Incorporating training into image segmentation is a good approach to achieve additional robustness. This work aims to develop an effective strategy to utilize shape prior knowledge, so that the segmentation label evolution can be driven toward the desired global optimum. METHODS:In the variational image segmen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4945046

    authors: Zhao T,Ruan D

    更新日期:2016-05-01 00:00:00

  • Integration of microwave tomography with magnetic resonance for improved breast imaging.

    abstract:PURPOSE:Breast magnetic resonance imaging is highly sensitive but not very specific for the detection of breast cancer. Opportunities exist to supplement the image acquisition with a more specific modality provided the technical challenges of meeting space limitations inside the bore, restricted breast access, and elec...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4820361

    authors: Meaney PM,Golnabi AH,Epstein NR,Geimer SD,Fanning MW,Weaver JB,Paulsen KD

    更新日期:2013-10-01 00:00:00

  • Practical dosimetric considerations of a 10-MV photon beam.

    abstract::An overall practical dosimetric study of a 10-MV photon beam produced by a Varian Clinac-18 linear accelerator is presented. In particular measurements were made to provide data which could be utilized in computerized dosage calculations using the concept of dividing the radiation beam into primary and scatter compone...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594311

    authors: Van Dyk J

    更新日期:1977-03-01 00:00:00

  • Comparison of radiograph-based texture analysis and bone mineral density with three-dimensional microarchitecture of trabecular bone.

    abstract:PURPOSE:Hip fracture is a serious health problem and textural methods are being developed to assess bone quality. The authors aimed to perform textural analysis at femur on high-resolution digital radiographs compared to three-dimensional (3D) microarchitecture comparatively to bone mineral density. METHODS:Sixteen ca...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3528125

    authors: Ranjanomennahary P,Ghalila SS,Malouche D,Marchadier A,Rachidi M,Benhamou C,Chappard C

    更新日期:2011-01-01 00:00:00

  • Differences in the lesion formation process between focused ultrasound and microwave ablations.

    abstract::The objective is to understand the differences in the lesion formation processes between microwave and high-intensity focused ultrasound (HIFU) ablation. The lesions formed by microwaves and HIFU were real-time monitored and compared using transparent tissue-mimicking phantoms at 60 and 70 W of driving electrical powe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2193689

    authors: Chen WS,Wu CC,Fang HY,Liu HL

    更新日期:2006-05-01 00:00:00

  • Suitability of laser stimulated TLD arrays as patient dose monitors in high dose x-ray imaging.

    abstract::Skin entrance doses of patients undergoing interventional x-ray procedures are capable of causing skin damage and should be monitored routinely. Single TLD chips are not suitable because the location of maximum skin exposure cannot be predicted. Most photographic films are too sensitive at diagnostic x-ray energies fo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597973

    authors: Geise RA,Schueler BA,Lien W,Jones SC

    更新日期:1997-10-01 00:00:00

  • Calculating output factors for photon beam radiotherapy using a convolution/superposition method based on a dual source photon beam model.

    abstract::A realistic photon beam model based on Monte Carlo simulation of clinical linear accelerators was implemented in a convolution/superposition dose calculation algorithm. A primary and an extra-focal sources were used in this beam model to represent the direct photons from the target and the scattered photons from other...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598111

    authors: Liu HH,Mackie TR,McCullough EC

    更新日期:1997-12-01 00:00:00

  • Evaluation of the microangiographic fluoroscope (MAF) using generalized system performance metrics.

    abstract:PURPOSE:The performance of a newly developed, high resolution, microangiographic fluoroscope (MAF) (35 μm pixel pitch and 300 μm thick CsI phosphor) was evaluated using a generalized linear system analysis and compared with that of a standard amorphous Si thin film transistor flat panel detector (FPD) (194 μm pixel pit...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4792460

    authors: Jain A,Bednarek DR,Rudin S

    更新日期:2013-03-01 00:00:00

  • SU-E-J-46: Use of Brainlab-ExacTrac IGRT with Dot-Decimal Electron Compensator(BolusECT) for Accurate Patient Positioning.

    abstract:PURPOSE:To Validate Brainlab-ExacTrac IGRT with Dot-Decimal electron compensator(BolusECT) for accurate patient positioning. METHODS:Dot-Decimal electron compensators(BolusECT) are used to achieve conformal dose distributions and greater sparing to normal structures for cases with varying patient contours and treated ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734881

    authors: Prabhu A,Saini D,Patadiya B,Shankar R,Garthwaite T

    更新日期:2012-06-01 00:00:00

  • A computer simulation of wavelet noise reduction in computed tomography.

    abstract::We describe the use of a graphical mathematical spreadsheet programming environment which can be used to simulate the acquisition and reconstruction processes of an x-ray computed tomography (CT) machine. The simulation is used to study the effect of photon counting statistics on the noise in the reconstructed image. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598654

    authors: Harpen MD

    更新日期:1999-08-01 00:00:00

  • A 3D ultrasound scanning system for image guided liver interventions.

    abstract:PURPOSE:Two-dimensional ultrasound (2D US) imaging is commonly used for diagnostic and intraoperative guidance of interventional liver procedures; however, 2D US lacks volumetric information that may benefit interventional procedures. Over the past decade, three-dimensional ultrasound (3D US) has been developed to prov...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4824326

    authors: Neshat H,Cool DW,Barker K,Gardi L,Kakani N,Fenster A

    更新日期:2013-11-01 00:00:00

  • A generic TG-186 shielded applicator for commissioning model-based dose calculation algorithms for high-dose-rate 192 Ir brachytherapy.

    abstract:PURPOSE:A joint working group was created by the American Association of Physicists in Medicine (AAPM), the European Society for Radiotherapy and Oncology (ESTRO), and the Australasian Brachytherapy Group (ABG) with the charge, among others, to develop a set of well-defined test case plans and perform calculations and ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12459

    authors: Ma Y,Vijande J,Ballester F,Tedgren ÅC,Granero D,Haworth A,Mourtada F,Fonseca GP,Zourari K,Papagiannis P,Rivard MJ,Siebert FA,Sloboda RS,Smith R,Chamberland MJP,Thomson RM,Verhaegen F,Beaulieu L

    更新日期:2017-11-01 00:00:00

  • Isotope specific resolution recovery image reconstruction in high resolution PET imaging.

    abstract:PURPOSE:Measuring and incorporating a scanner-specific point spread function (PSF) within image reconstruction has been shown to improve spatial resolution in PET. However, due to the short half-life of clinically used isotopes, other long-lived isotopes not used in clinical practice are used to perform the PSF measure...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4870985

    authors: Kotasidis FA,Angelis GI,Anton-Rodriguez J,Matthews JC,Reader AJ,Zaidi H

    更新日期:2014-05-01 00:00:00

  • An investigation of a new amorphous silicon electronic portal imaging device for transit dosimetry.

    abstract::The relationship between the pixel value and exit dose was investigated for a new commercially available amorphous silicon electronic portal imaging device. The pixel to dose mapping function was established to be linear for detector distances between 116.5 cm to 150 cm from the source, radiation field sizes from 5 x ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1508108

    authors: Grein EE,Lee R,Luchka K

    更新日期:2002-10-01 00:00:00

  • Branch order regression for modeling brain vasculature.

    abstract:PURPOSE:Many biological objects, including neuronal dendrites, blood vasculature, airways, phylogenetic trees, produce tree structured data. Current methods of analysis either ignore the complex structure of trees or use distance-based methods which limit the scope of multivariate modeling. METHODS:We propose a branch...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12751

    authors: Roy Choudhury K,Skwerer S

    更新日期:2018-03-01 00:00:00

  • Comparison of transperineal ultrasound image guidance technique to transabdominal technique for prostate radiation therapy.

    abstract:INTRODUCTION:Ultrasound (US) guidance of the prostate has long been conducted using a transabdominal (TA) approach. More recently, a transperineal (TP) approach has been made available for image guidance. Our aim was to determine if both methods produced similar alignments within the same patients. MATERIALS AND METHO...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14522

    authors: Szegedi M,Boehm C,Paxton A,Rassiah-Szegedi P,Sarkar V,Zhao H,Su F,Kokeny KE,Lloyd S,Tward J,Salter BJ

    更新日期:2020-12-01 00:00:00

  • Efficient low-dose CT artifact mitigation using an artifact-matched prior scan.

    abstract:PURPOSE:Low-dose CT has attracted increasing attention due to growing concerns about radiation exposure in medical scans. However, the frugal use of x-ray radiation inevitably reduces the quality of the CT images, introducing artifacts such as noise and streaks which make the reconstructed images difficult to read in c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736528

    authors: Xu W,Mueller K

    更新日期:2012-08-01 00:00:00

  • Evaluation of three-dimensional finite element-based deformable registration of pre- and intraoperative prostate imaging.

    abstract::In this report we evaluate an image registration technique that can improve the information content of intraoperative image data by deformable matching of preoperative images. In this study, pretreatment 1.5 tesla (T) magnetic resonance (MR) images of the prostate are registered with 0.5 T intraoperative images. The m...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1414009

    authors: Bharatha A,Hirose M,Hata N,Warfield SK,Ferrant M,Zou KH,Suarez-Santana E,Ruiz-Alzola J,D'Amico A,Cormack RA,Kikinis R,Jolesz FA,Tempany CM

    更新日期:2001-12-01 00:00:00

  • Determining Pion, the correction factor for recombination losses in an ionization chamber.

    abstract::The 1983 AAPM protocol for the determination of absorbed dose from high-energy photon and electron beams recommends using Pion (the reciprocal of collection efficiency), as determined by the two-voltage technique, to correct for recombination losses in ionization chambers. Methods and data for the determination of ion...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595574

    authors: Weinhous MS,Meli JA

    更新日期:1984-11-01 00:00:00