SAPHIRE (scintillator avalanche photoconductor with high resolution emitter readout) for low dose x-ray imaging: spatial resolution.

Abstract:

:An indirect flat panel imager (FPI) with programmable avalanche gain and field emitter array (FEA) readout is being investigated for low-dose and high resolution x-ray imaging. It is made by optically coupling a structured x-ray scintillator, e.g., thallium (Tl) doped cesium iodide (CsI), to an amorphous selenium (a-Se) avalanche photoconductor called high-gain avalanche rushing amorphous photoconductor (HARP). The charge image created by the scintillator/HARP (SHARP) combination is read out by the electron beams emitted from the FEA. The proposed detector is called scintillator avalanche photoconductor with high resolution emitter readout (SAPHIRE). The programmable avalanche gain of HARP can improve the low dose performance of indirect FPI while the FEA can be made with pixel sizes down to 50 microm. Because of the avalanche gain, a high resolution type of CsI (Tl), which has not been widely used in indirect FPI due to its lower light output, can be used to improve the high spatial frequency performance. The purpose of the present article is to investigate the factors affecting the spatial resolution of SAPHIRE. Since the resolution performance of the SHARP combination has been well studied, the focus of the present work is on the inherent resolution of the FEA readout method. The lateral spread of the electron beam emitted from a 50 microm x 50 microm pixel FEA was investigated with two different electron-optical designs: mesh-electrode-only and electrostatic focusing. Our results showed that electrostatic focusing can limit the lateral spread of electron beams to within the pixel size of down to 50 microm. Since electrostatic focusing is essentially independent of signal intensity, it will provide excellent spatial uniformity.

journal_name

Med Phys

journal_title

Medical physics

authors

Li D,Zhao W

doi

10.1118/1.2937652

subject

Has Abstract

pub_date

2008-07-01 00:00:00

pages

3151-61

issue

7

eissn

0094-2405

issn

2473-4209

journal_volume

35

pub_type

杂志文章
  • Characterization of electron contamination in megavoltage photon beams.

    abstract::The purpose of the present study is to characterize electron contamination in photon beams in different clinical situations. Variations with field size, beam modifier (tray, shaping block) and source-surface distance (SSD) were studied. Percentage depth dose measurements with and without a purging magnet and replacing...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1895793

    authors: Lopez Medina A,Teijeiro A,Garcia J,Esperon J,Terron JA,Ruiz DP,Carrion MC

    更新日期:2005-05-01 00:00:00

  • Poster - Thur Eve - 66: A planning comparison between RapidArc and intensity modulated radiotherapy for head and neck cancer.

    abstract::Volumetric modulated arc therapy (VMAT) has recently been used to improve the dose distribution and efficiency of treatment delivery over the standard intensity-modulated radiotherapy (IMRT) technique. This study compares the dosimetry between RapidArc plan and standard IMRT plan for head and neck cancer. Three head a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740174

    authors: Jiang R,Fleck A,Schaly B,Charland P,Zhan L,Alliet K,Rachakonda R,Osei E

    更新日期:2012-07-01 00:00:00

  • Changes realized from extended bit-depth and metal artifact reduction in CT.

    abstract:PURPOSE:High-Z material in computed tomography (CT) yields metal artifacts that degrade image quality and may cause substantial errors in dose calculation. This study couples a metal artifact reduction (MAR) algorithm with enhanced 16-bit depth (vs standard 12-bit) to quantify potential gains in image quality and dosim...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4805102

    authors: Glide-Hurst C,Chen D,Zhong H,Chetty IJ

    更新日期:2013-06-01 00:00:00

  • Using FDG-PET activity as a surrogate for tumor cell density and its effect on equivalent uniform dose calculation.

    abstract::The concept of equivalent uniform dose (EUD) has been suggested as a means to quantitatively consider heterogeneous dose distributions within targets. Tumor cell density/function is typically assumed to be uniform. We herein propose to use 18F-labeled 2-deoxyglucose (FDG) positron emission tomography (PET) tumor imagi...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.1779372

    authors: Zhou SM,Wong TZ,Marks LB

    更新日期:2004-09-01 00:00:00

  • SU-E-J-194: The Impact of Different Imaging Measures on Treatment Response Assessment of Bone Metastases.

    abstract:PURPOSE:Several treatment response metrics, such as RECIST and PERCIST, have been established for assessing individual solid tumors. However, metastatic prostate cancer poses a unique challenge to these metrics because bone lesions are often numerous and non-measureable. This study investigated the impact of using diff...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735035

    authors: Morrison C,Liu G,Jeraj R

    更新日期:2012-06-01 00:00:00

  • SU-E-T-96: Energy Dependence of the New GafChromic- EBT3 Film's Dose Response-Curve.

    abstract:PURPOSE:To study and compare the dose response curves of the new GafChromic EBT3 film for megavoltage and kilovoltage x-ray beams, with different spatial resolution. METHODS:Two sets of EBT3 films (lot#A101711-02) were exposed to each x-ray beam (6MV, 15MV and 50kV) at 8 dose values (50-3200cGy). The megavoltage beams...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735153

    authors: Chiu-Tsao S,Massillon-Jl G,Domingo-Muñoz I,Chan M

    更新日期:2012-06-01 00:00:00

  • Attention-aware fully convolutional neural network with convolutional long short-term memory network for ultrasound-based motion tracking.

    abstract:PURPOSE:One of the promising options for motion management in radiation therapy (RT) is the use of LINAC-compatible robotic-arm-mounted ultrasound imaging system due to its high soft tissue contrast, real-time capability, absence of ionizing radiation, and low cost. The purpose of this work is to develop a novel deep l...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13510

    authors: Huang P,Yu G,Lu H,Liu D,Xing L,Yin Y,Kovalchuk N,Xing L,Li D

    更新日期:2019-05-01 00:00:00

  • Ultra-low-dose CT image denoising using modified BM3D scheme tailored to data statistics.

    abstract:PURPOSE:It is important to enhance image quality for low-dose CT acquisitions to push the ALARA boundary. Current state-of-the-art block-matching three-dimensional (BM3D) denoising scheme assumes white Gaussian noise (WGN) model. This study proposes a novel filtering module to be incorporated into the BM3D framework fo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13252

    authors: Zhao T,Hoffman J,McNitt-Gray M,Ruan D

    更新日期:2019-01-01 00:00:00

  • Toward the combined optimization of dynamic axes (CODA) for stereotactic radiotherapy and radiosurgery using fixed couch trajectories.

    abstract:PURPOSE:To develop a novel system for patient-specific combined optimization of couch, collimator, and gantry angles for use in volumetric modulated arc therapy (VMAT) treatment planning. The system was designed to produce highly compact dose distributions by extensively sampling the 4π space. Automated fixed couch tra...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13887

    authors: MacDonald RL,Syme A,Little B,Ward L,Thomas CG

    更新日期:2020-02-01 00:00:00

  • Comparing calibration methods of electron beams using plane-parallel chambers with absorbed-dose to water based protocols.

    abstract::Recent absorbed-dose-based protocols allow for two methods of calibrating electron beams using plane-parallel chambers, one using the N(Co)D,w for a plane-parallel chamber, and the other relying on cross-calibration of the plane-parallel chamber in a high-energy electron beam against a cylindrical chamber which has an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1449876

    authors: Stewart KJ,Seuntjens JP

    更新日期:2002-03-01 00:00:00

  • Attenuation-based estimation of patient size for the purpose of size specific dose estimation in CT. Part I. Development and validation of methods using the CT image.

    abstract:PURPOSE:For the purpose of size-specific dose estimation, information regarding patient attenuation is required. The purpose of this work is to describe a method for measuring patient attenuation and expressing the results in terms of a water cylinder, with cross sectional area A(w), which would absorb the same average...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4754303

    authors: Wang J,Duan X,Christner JA,Leng S,Yu L,McCollough CH

    更新日期:2012-11-01 00:00:00

  • Dosimetric effect of respiration-gated beam on IMRT delivery.

    abstract::Intensity modulated radiation therapy (IMRT) with a dynamic multileaf collimator (DMLC) requires synchronization of DMLC leaf motion with dose delivery. A delay in DMLC communication is known to cause leaf lag and lead to dosimetric errors. The errors may be exacerbated by gated operation. The purpose of this study wa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1592017

    authors: Duan J,Shen S,Fiveash JB,Brezovich IA,Popple RA,Pareek PN

    更新日期:2003-08-01 00:00:00

  • Traceable micro-CT scaling accuracy phantom for applications requiring exact measurement of distances or volumes.

    abstract:PURPOSE:Volumetric x-ray microcomputed tomography (CT) can be employed in a variety of quantitative research applications such as image-guided interventions or characterization of medical devices. To ensure the highest geometric fidelity of images for these applications, a phantom and image processing algorithm have be...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4752083

    authors: Waring CS,Bax JS,Samarabandu A,Holdsworth DW,Fenster A,Lacefield JC

    更新日期:2012-10-01 00:00:00

  • Treatment planning system and beam data validation for the ZAP-X: a novel self-shielded stereotactic radiosurgery system.

    abstract:PURPOSE:To evaluate the treatment planning system (TPS) performance of the ZAP-X stereotactic radiosurgery (SRS) system through nondosimetric, dosimetric, and end-to-end (E2E) tests. METHODS:A comprehensive set of TPS commissioning and validation tests were developed using published guidelines. Nondosimetric validatio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14740

    authors: Srivastava SP,Jani SS,Pinnaduwage DS,Yan X,Rogers L,Barranco FD,Barani IJ,Sorensen S

    更新日期:2021-01-28 00:00:00

  • Optimized low-kV spectrum of dual-energy CT equipped with high-kV tin filtration for electron density measurements.

    abstract:PURPOSE:This paper describes the low-kV spectral optimization of dual-energy CT (DECT) equipped with high-kV tin filtration for the quantitative acquisition of electron density information, which is essential for treatment planning in radiotherapy. In addition, an analytical DECT image simulation was preliminarily perf...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3584200

    authors: Saito M

    更新日期:2011-06-01 00:00:00

  • Technical Note: Evaluation of a 160-mm/256-row CT scanner for whole-heart quantitative myocardial perfusion imaging.

    abstract:PURPOSE:The authors investigated the performance of a recently introduced 160-mm/256-row CT system for low dose quantitative myocardial perfusion (MP) imaging of the whole heart. This platform is equipped with a gantry capable of rotating at 280 ms per full cycle, a second generation of adaptive statistical iterative r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4957389

    authors: So A,Imai Y,Nett B,Jackson J,Nett L,Hsieh J,Wisenberg G,Teefy P,Yadegari A,Islam A,Lee TY

    更新日期:2016-08-01 00:00:00

  • SU-E-T-485: Validation of Acuros XB Dose Calculations in SBRT Lung Planning with Monte Carlo Methods.

    abstract:PURPOSE:The Acuros XB (AXB) Advanced Dose algorithm (Varian Medical Systems) represents a dramatic shift in clinical photon dose calculation methodology from pencil-beam superposition/convolution methods. Early studies evaluating the accuracy of the algorithm in lung have found good agreement with both measurement and ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735574

    authors: Bush K,Wang L,Mok E

    更新日期:2012-06-01 00:00:00

  • Technical Note: Gray tracking in medical color displays-A report of Task Group 196.

    abstract:PURPOSE:The authors discuss measurement methods and instrumentation useful for the characterization of the gray tracking performance of medical color monitors for diagnostic applications. The authors define gray tracking as the variability in the chromaticity of the gray levels in a color monitor. METHODS:The authors ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4953186

    authors: Badano A,Wang J,Boynton P,Le Callet P,Cheng WC,Deroo D,Flynn MJ,Matsui T,Penczek J,Revie C,Samei E,Steven PM,Swiderski S,Van Hoey G,Yamaguchi M,Hasegawa M,Nagy BV

    更新日期:2016-07-01 00:00:00

  • Evaluation of tumor localization in respiration motion-corrected cone-beam CT: prospective study in lung.

    abstract:PURPOSE:Target localization accuracy of cone-beam CT (CBCT) images used in radiation treatment of respiratory disease sites is affected by motion artifacts (blurring and streaking). The authors have previously reported on a method of respiratory motion correction in thoracic CBCT at end expiration (EE). The previous re...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4896101

    authors: Dzyubak O,Kincaid R,Hertanto A,Hu YC,Pham H,Rimner A,Yorke E,Zhang Q,Mageras GS

    更新日期:2014-10-01 00:00:00

  • Vessel size measurements in angiograms: manual measurements.

    abstract::Vessel size measurement is perhaps the most often performed quantitative analysis in diagnostic and interventional angiography. Although automated vessel sizing techniques are generally considered to have good accuracy and precision, we have observed that clinicians rarely use these techniques in standard clinical pra...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1562491

    authors: Hoffmann KR,Dmochowski J,Nazareth DP,Miskolczi L,Nemes B,Gopal A,Wang Z,Rudin S,Bednarek DR

    更新日期:2003-04-01 00:00:00

  • Automated registration of diagnostic to prediagnostic x-ray mammograms: evaluation and comparison to radiologists' accuracy.

    abstract:PURPOSE:To compare and evaluate intensity-based registration methods for computation of serial x-ray mammogram correspondence. METHODS:X-ray mammograms were simulated from MRIs of 20 women using finite element methods for modeling breast compressions and employing a MRI/x-ray appearance change model. The parameter con...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3457470

    authors: Pinto Pereira SM,Hipwell JH,McCormack VA,Tanner C,Moss SM,Wilkinson LS,Khoo LA,Pagliari C,Skippage PL,Kliger CJ,Hawkes DJ,Silva IM

    更新日期:2010-09-01 00:00:00

  • Radiation attenuation by lead and nonlead materials used in radiation shielding garments.

    abstract::The attenuating properties of several types of lead (Pb)-based and non-Pb radiation shielding materials were studied and a correlation was made of radiation attenuation, materials properties, calculated spectra and ambient dose equivalent. Utilizing the well-characterized x-ray and gamma ray beams at the National Rese...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2426404

    authors: McCaffrey JP,Shen H,Downton B,Mainegra-Hing E

    更新日期:2007-02-01 00:00:00

  • SU-E-J-58: Patient-Specific Biomechanical Head and Neck Models for Interfraction Dose Accumulation.

    abstract:PURPOSE:In this abstract, we discuss a biomechanical head and neck model that will be able to represent patient setup variations as well as physiologic changes and subsequently enable dose calculations on the deformed anatomy. METHODS:We selected Multi Pose MRI as the imaging modality to aid in model development and v...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734893

    authors: Santhanam A,Ennis D,Low D,Kupelian P

    更新日期:2012-06-01 00:00:00

  • The influence of bowtie filtration on cone-beam CT image quality.

    abstract::The large variation of x-ray fluence at the detector in cone-beam CT (CBCT) poses a significant challenge to detectors' limited dynamic range, resulting in the loss of skinline as well as reduction of CT number accuracy, contrast-to-noise ratio, and image uniformity. The authors investigate the performance of a bowtie...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3017470

    authors: Mail N,Moseley DJ,Siewerdsen JH,Jaffray DA

    更新日期:2009-01-01 00:00:00

  • Reliability of water proton chemical shift temperature calibration for focused ultrasound ablation therapy.

    abstract::Our purpose in this work was to assess the reliability of the calibration coefficient for magnetic resonance water proton chemical shift temperature mapping. Over a six month period, the calibration coefficient was measured 15 times in several different phantoms. A highly linear relationship between water proton chemi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598864

    authors: Wu T,Kendell KR,Felmlee JP,Lewis BD,Ehman RL

    更新日期:2000-01-01 00:00:00

  • Automated segmentation of lungs with severe interstitial lung disease in CT.

    abstract:PURPOSE:Accurate segmentation of lungs with severe interstitial lung disease (ILD) in thoracic computed tomography (CT) is an important and difficult task in the development of computer-aided diagnosis (CAD) systems. Therefore, we developed in this study a texture analysis-based method for accurate segmentation of lung...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3222872

    authors: Wang J,Li F,Li Q

    更新日期:2009-10-01 00:00:00

  • SU-D-BRCD-02: A Novel Cylindrical 3D Water Scanner for Beam Data Collection: I. Validation of the Automatic-Setup.

    abstract:PURPOSE:To determine the accuracy and reproducibility of the automatic- setup procedure of a 3D water scanner (3D SCANNER, Sun Nuclear Corp). The procedure automatically aligns the scanner's coordinate system to the Linac coordinate system. A unique off-center detector holder extends the scan range to 630 mm, eliminati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734668

    authors: Li J,Lu B,Yan G,Huang Y,Liu C

    更新日期:2012-06-01 00:00:00

  • Improved gradient-echo 3D magnetic resonance imaging using compressed sensing and Toeplitz encoding with phase-scrambled RF excitation.

    abstract:PURPOSE:To develop a novel three-dimensional (3D) hybrid-encoding framework using compressed sensing (CS) and Toeplitz encoding with variable phase-scrambled radio-frequency (RF) excitation, which has the following advantages: low power deposition of RF pulses, reduction of the signal dynamic range, no additional hardw...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13987

    authors: Wang H,Liang D,Su S,King KF,Chang Y,Liu X,Zheng H,Ying L

    更新日期:2020-04-01 00:00:00

  • Characterization of scintillator-based detectors for few-ten-keV high-spatial-resolution x-ray imaging.

    abstract:PURPOSE:High-spatial-resolution x-ray imaging in the few-ten-keV range is becoming increasingly important in several applications, such as small-animal imaging and phase-contrast imaging. The detector properties critically influence the quality of such imaging. Here the authors present a quantitative comparison of scin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4948687

    authors: Larsson JC,Lundström U,Hertz HM

    更新日期:2016-06-01 00:00:00

  • An automated procedure for the quality assurance of electron beam output and energy.

    abstract::In this article, we report on the development of a simple and accurate method for quality assurance of electron beam output and energy. Aluminum disks of thicknesses d(max) or d50 of the particular electron energy are positioned sequentially over a parallel-plate ion chamber and the ratio of the two signals is compare...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1688040

    authors: Woo MK,Videla NG

    更新日期:2004-05-01 00:00:00