PURPOSE:To determine the accuracy and reproducibility of the automatic- setup procedure of a 3D water scanner (3D SCANNER, Sun Nuclear Corp). The procedure automatically aligns the scanner's coordinate system to the Linac coordinate system. A unique off-center detector holder extends the scan range to 630 mm, eliminating the need for scanner shifts for large-field scans. METHODS:The automatic-setup procedure provides means to automatically (1) level the tank; (2) zero the detector position to water surface; (3) align the scanner's coordinate system to the Linac system; and (4) correct motor hysteresis. After automatic-setup, (1) and (2) were evaluated visually by three physicists. Step (3) was tested by moving one of the jaws to the isocenter and scans were made along the jaw edge. Angular misalignment between the scanner and the Linac would Result in a noticeably tilted profile. Step (4) was tested by scanning with the chamber moving forward and then backward five times. The accuracy of the off-center detector holder was tested by comparing scans made using the regularand the off-center detector holders. All tests were repeated three times. RESULTS:All tests of the water surface and horizontal chamber movementwere acceptable from the nine independent evaluations. Scans along the jawedge resulted in < 1% in profile tilt, corresponding to < 0.05 degree in angular misalignment. Same direction scans resulted in field edge differences < 0.05 mm, and < 0.2 mm when compared to scans in thereverse direction. There was no difference in accuracy when different scan speeds were used. Profiles obtained using the regular and the off-centerdetector holders were identical. CONCLUSIONS:The automatic-setupprocedure resulted in accurate alignment of the 3D SCANNER to the Linac. These results were user-independent. It also provides the ability to scan large fields without the need to change tank setup. This work was partially supported by a research grant from Sun Nuclear Corp., Melbourne, FL.
journal_name
Med Physjournal_title
Medical physicsauthors
Li J,Lu B,Yan G,Huang Y,Liu Cdoi
10.1118/1.4734668subject
Has Abstractpub_date
2012-06-01 00:00:00pages
3613issue
6Part3eissn
0094-2405issn
2473-4209journal_volume
39pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:Dosimetry with ionization chambers in clinical ion beams for radiation therapy requires correction for recombination effects. However, common radiation protocols discriminate between initial and general recombination and provide no universal correction method for the presence of both recombination types in ion ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4962483
更新日期:2016-10-01 00:00:00
abstract:PURPOSE:To compare reconstructed volumes calculated via planimetry and frustum algorithms in the context of stepped transrectal ultrasound (US) imaging, and to estimate the reconstruction error for prostate volumes. METHODS:Prostate contours for 40 permanent implant patients were delineated on magnetic resonance (MR) ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4789920
更新日期:2013-03-01 00:00:00
abstract:PURPOSE:Photoacoustic imaging has proven to be able to detect vascularization-driven optical absorption contrast associated with tumors. In order to detect breast tumors located a few centimeter deep in tissue, a sensitive ultrasound detector is of crucial importance for photoacoustic mammography. Further, because the ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4792462
更新日期:2013-03-01 00:00:00
abstract::The dose received in the buildup region outside the primary beam has been measured for 60Co gamma rays and 6- and 18-MV X rays. The variation of this dose with field size and depth was evaluated. The effect of blocking trays and the importance of their design was determined. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595508
更新日期:1984-05-01 00:00:00
abstract:PURPOSE:The primary feasibility steps of demonstrating the ability of microwave-induced thermoacoustic (TA) in phantoms have been previously reported. However, none were shown to target a diseased site in living subjects in thermoacoustic tomography (TAT) field so far. To determine the expressions of oncogenic surface ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3466696
更新日期:2010-08-01 00:00:00
abstract::Available deformable registration methods are often inaccurate over large organ variation encountered, for example, in the rectum and bladder. The authors developed a novel approach to accurately and effectively register large deformations in the prostate region for adaptive radiation therapy. A software tool combinin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3095777
更新日期:2009-04-01 00:00:00
abstract:PURPOSE:To present EBT2 film verification of treatment planning with the eXtend System, a relocatable frame system for multiple-fraction or serial multiple-session radiosurgery. METHODS:A human head shaped phantom simulated the verification process for fractionated Gamma Knife (GK) treatment. Phantom preparation for e...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735487
更新日期:2012-06-01 00:00:00
abstract::Total body photon irradiation (TBI) may be delivered with a number of standard techniques, typically using extended SSD geometries to obtain large field sizes. Since 1982 we have treated over 620 patients (adult and pediatric) mostly in the floor-located prone/supine treatment position with AP/PA beams using a column ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4740139
更新日期:2012-07-01 00:00:00
abstract::Nuclear magnetic resonance (NMR) imaging of perfluorocarbon (PFC) emulsions and neat liquids has shown potential for in vivo oxygen imaging in blood and organ tissue. PFC compounds exhibit complicated NMR spectra caused by chemical shifts and spin-spin couplings which can lead to artifacts and degraded spatial resolut...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595960
更新日期:1986-07-01 00:00:00
abstract:PURPOSE:To analyze the noise performance of the edge illumination phase-based x-ray imaging technique when applying "single-shot" phase retrieval. The latter consists in applying a sample-specific low-pass filter to the raw data, leading to "hybrid" images in which phase and attenuation contrast are merged with each ot...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14366
更新日期:2020-09-01 00:00:00
abstract::Part III (oral exam) is the final part of ABR board exam for Diagnostic Medical Physics. In this exam, each of five oral examiners questions the candidate in each of five question categories. Oral exam has unique challenges to the candidate compared with the written exams. The candidate is expected to have not only ad...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4736136
更新日期:2012-06-01 00:00:00
abstract::Calibration of an imported strontium-90 ophthalmic applicator at the U.S. National Bureau of Standards (now the National Institute of Standards and Technology) has disclose a significant discrepancy in dose rate calibration (32%-35%) with that quoted by the manufacturer. The University of Wisconsin has investigated th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596702
更新日期:1991-03-01 00:00:00
abstract::Fluoroscopy is a low dose imaging technique. As such, a very sensitive detector is required to create images of good quality. Present day flat panel active matrix read out systems introduce an amount of noise that inhibits present direct and indirect methods from producing optimal quality images at fluoroscopic exposu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1513157
更新日期:2002-11-01 00:00:00
abstract::Ir-192 wires have been used in low-dose-rate brachytherapy for many years. Commercially available treatment planning systems approximate the dose rate distribution of the straight or curved wires applying the superposition principle using one of the following methods: (i) The wire is modeled as a set of point sources,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2839102
更新日期:2008-03-01 00:00:00
abstract:PURPOSE:Intensity-modulated proton therapy (IMPT) is known to be sensitive to patient setup and range uncertainty issues. Multiple robust optimization methods have been developed to mitigate the impact of these uncertainties. Here, we propose a new robust optimization method, which provides an alternative way of robust...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13276
更新日期:2019-01-01 00:00:00
abstract:PURPOSE:The Synchrony respiratory motion tracking of the CyberKnife system purports to provide real-time tumor motion compensation during robotic radiosurgery. Such a complex delivery system requires thorough quality assurance. In this work, RADPOS applicability as a dose and position quality assurance tool for CyberKn...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13102
更新日期:2018-07-25 00:00:00
abstract:PURPOSE:To assess the temporal and spatial accuracy of the GateCT™ system (VisionRT, London, UK), a recently released respiratory tracking system for 4DCT, under both ideal and nonideal respiratory conditions. METHODS:Three experiments were performed by benchmarking and comparing its results with the ground-truth inpu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3671941
更新日期:2012-01-01 00:00:00
abstract::A theoretical analysis of the x-ray phase contrast imaging and its validation via synchrotron radiation imaging is here presented. Two different mathematical models have been followed: the simpler ray-optical approach and the more rigorous Fresnel-Kirchoff diffraction theory. Subsequently, the conditions upon which th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2126207
更新日期:2005-12-01 00:00:00
abstract::The calibration and quality control of compensators is conventionally performed with an ion chamber in a water-equivalent phantom. In our center, the compensator factor and four off-axis fluence ratios are measured to verify the central axis beam modulation and orientation of the compensator. Here we report the invest...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1584040
更新日期:2003-07-01 00:00:00
abstract::The dose distributions in the bifurcated vessels treated with intravascular brachytherapyline sources are complicated and depend on the bifurcation geometry consisting of a main and a branch vessel at different angles. To investigate the dosimetric effects at the bifurcation, calculations were performed on branching v...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1582813
更新日期:2003-07-01 00:00:00
abstract:PURPOSE:We propose a new metric called Distance Discordance (DD), which is defined as the distance between two anatomic points from two moving images, which are co-located on some reference image, when deformed onto another reference image. METHODS:To demonstrate the concept of DD, we created a reference software phan...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4736139
更新日期:2012-06-01 00:00:00
abstract::The visual observer performance for detecting low-contrast patterns by employing both the receiver operating characteristic (ROC) and the 9-alternative forced choice (9-AFC) method is investigated. For each observer and each experimental technique, the results were reproducible with respect to a repeated observation. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596986
更新日期:1993-05-01 00:00:00
abstract:PURPOSE:To examine schemes to grade the severity of metal susceptibility artifacts on image quality using cardiac MRI pulse sequences. METHODS:A post-thoracotomy patient was simulated with a stainless steel sternal wire (Syneture,MA; size=6, diameter=48mm), placed securely on an ACR MRI phantom. Phantom was scanned on...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734785
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Intraventricular hemorrhage (IVH) is a major cause of brain injury in preterm neonates. Three dimensional ultrasound (US) imaging systems have been developed to visualize 3D anatomical structure of preterm neonatal intracranial ventricular system with IVH and ventricular dilation. To allow quantitative analysis...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4932366
更新日期:2015-11-01 00:00:00
abstract:PURPOSE:Pulse pileup occurring at high x-ray fluxes can severely degrade the energy resolution provided by a photon counting detector, which can represent a problem in spectroscopic CT when performing quantitative material discrimination tasks. As the effects of pileup can be most easily seen as a degradation of a dete...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4820535
更新日期:2013-10-01 00:00:00
abstract::In the case of non-small cell lung cancer, doses typically prescribed (60-66 Gy) are not sufficient to ensure a satisfactory tumor control probability. Dose escalation needs to be realized, but dose to organs at risk (OARs) must be kept under widely accepted clinical thresholds. Also, lung functionality is not homogen...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2965976
更新日期:2008-07-01 00:00:00
abstract::We have performed a comprehensive dosimetric characterization of the Oncura model 6711 125I seed using both experimental [LiF thermoluminscent dosimetry (TLD)] and theoretical (Monte Carlo photon transport) methods. In addition to determining the dosimetric parameters of the 6711, this report quantified: (1) the angul...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2388158
更新日期:2006-12-01 00:00:00
abstract::Encapsulated, cylindrical sources containing 2, 5, and 8 Ci of 241Am have been designed and fabricated for intracavitary irradiation of uterine cancers. Exposure rates in air and dose rates in water around these sources have been measured using an ionization chamber and a lithium fluoride thermoluminescent dosimetry s...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596007
更新日期:1987-09-01 00:00:00
abstract:PURPOSE:To experimentally commission a dual-energy CT (DECT) joint statistical image reconstruction (JSIR) method, which is built on a linear basis vector model (BVM) of material characterization, for proton stopping power ratio (SPR) estimation. METHODS:The JSIR-BVM method builds on the relationship between the energ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13287
更新日期:2019-01-01 00:00:00
abstract:PURPOSE:To investigate whether building a knowledge-based planning (KBP) model with prostate bed plans constructed from constrained hierarchical optimization (CHO) would result in more efficient model construction with more consistent output than a model built using plans from a traditional, trial-and-error-based optim...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13163
更新日期:2018-10-01 00:00:00