Experimental implementation of a joint statistical image reconstruction method for proton stopping power mapping from dual-energy CT data.

Abstract:

PURPOSE:To experimentally commission a dual-energy CT (DECT) joint statistical image reconstruction (JSIR) method, which is built on a linear basis vector model (BVM) of material characterization, for proton stopping power ratio (SPR) estimation. METHODS:The JSIR-BVM method builds on the relationship between the energy-dependent photon attenuation coefficients and the proton stopping power via a pair of BVM component weights. The two BVM component images are simultaneously reconstructed from the acquired DECT sinograms and then used to predict the electron density and mean excitation energy (I-value), which are required by the Bethe equation for SPR computation. A post-reconstruction image-based DECT method, which utilizes the two separate CT images reconstructed via the scanner's software, was implemented for comparison. The DECT measurement data were acquired on a Philips Brilliance scanner at 90 and 140 kVp for two phantoms of different sizes. Each phantom contains 12 different soft and bony tissue surrogates with known compositions. The SPR estimation results were compared to the reference values computed from the known compositions. The difference of the computed water equivalent path lengths (WEPL) across the phantoms between the two methods was also compared. RESULTS:The overall root-mean-square (RMS) of SPR estimation error of the JSIR-BVM method are 0.33% and 0.37% for the head- and body-sized phantoms, respectively, and all SPR estimates of the test samples are within 0.7% of the reference ground truth. The image-based method achieves overall RMS errors of 2.35% and 2.50% for the head- and body-sized phantoms, respectively. The JSIR-BVM method also reduces the pixel-wise random variation by 4-fold to 6-fold within homogeneous regions compared to the image-based method. The average differences between the JSIR-BVM method and the image-based method are 0.54% and 1.02% for the head- and body-sized phantoms, respectively. CONCLUSION:By taking advantage of an accurate polychromatic CT data model and a model-based DECT statistical reconstruction algorithm, the JSIR-BVM method accounts for both systematic bias and random noise in the acquired DECT measurement data. Therefore, the JSIR-BVM method achieves good accuracy and precision on proton SPR estimation for various tissue surrogates and object sizes. In contrast, the experimentally achievable accuracy of the image-based method may be limited by the uncertainties in the image formation process. The result suggests that the JSIR-BVM method has the potential for more accurate SPR prediction compared to post-reconstruction image-based methods in clinical settings.

journal_name

Med Phys

journal_title

Medical physics

authors

Zhang S,Han D,Williamson JF,Zhao T,Politte DG,Whiting BR,O'Sullivan JA

doi

10.1002/mp.13287

subject

Has Abstract

pub_date

2019-01-01 00:00:00

pages

273-285

issue

1

eissn

0094-2405

issn

2473-4209

journal_volume

46

pub_type

杂志文章
  • Task Group 284 Report: Magnetic Resonance Imaging Simulation in Radiotherapy: Considerations for Clinical Implementation, Optimization, and Quality Assurance.

    abstract::The use of dedicated magnetic resonance simulation (MR-SIM) platforms in Radiation Oncology has expanded rapidly, introducing new equipment and functionality with the overall goal of improving the accuracy of radiation treatment planning. However, this emerging technology presents a new set of challenges that need to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14695

    authors: Glide-Hurst CK,Paulson ES,McGee K,Tyagi N,Hu Y,Balter J,Bayouth J

    更新日期:2021-01-01 00:00:00

  • A scanning system for chest radiography with regional exposure control: theoretical considerations.

    abstract::Conventional chest radiography is limited by the presence of scattered radiation and the small useful exposure range of radiographic film. A computer-assisted scanning system to minimize these two effects is outlined. The system uses a small beam of radiation swept over the patient's chest in a raster pattern to expos...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595327

    authors: Plewes DB

    更新日期:1983-09-01 00:00:00

  • Technical Note: Spot characteristic stability for proton pencil beam scanning.

    abstract:PURPOSE:The spot characteristics for proton pencil beam scanning (PBS) were measured and analyzed over a 16 month period, which included one major site configuration update and six cyclotron interventions. The results provide a reference to establish the quality assurance (QA) frequency and tolerance for proton pencil ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4939663

    authors: Chen CC,Chang C,Moyers MF,Gao M,Mah D

    更新日期:2016-02-01 00:00:00

  • Comparisons of treatment optimization directly incorporating systematic patient setup uncertainty with a margin-based approach.

    abstract:PURPOSE:To develop a probabilistic treatment planning (PTP) method which is robust to systematic patient setup errors and to compare PTP plans with plans generated using a planning target volume (PTV) margin optimized to give the same target coverage probability as the PTP plan. METHODS:Plans adhering to the RTOG-0126...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3679856

    authors: Moore JA,Gordon JJ,Anscher M,Silva J,Siebers JV

    更新日期:2012-02-01 00:00:00

  • Dose enhancement in radiotherapy of small lung tumors using inline magnetic fields: A Monte Carlo based planning study.

    abstract:PURPOSE:To report on significant dose enhancement effects caused by magnetic fields aligned parallel to 6 MV photon beam radiotherapy of small lung tumors. Findings are applicable to future inline MRI-guided radiotherapy systems. METHODS:A total of eight clinical lung tumor cases were recalculated using Monte Carlo me...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4938580

    authors: Oborn BM,Ge Y,Hardcastle N,Metcalfe PE,Keall PJ

    更新日期:2016-01-01 00:00:00

  • Calculation of x-ray spectra emerging from an x-ray tube. Part II. X-ray production and filtration in x-ray targets.

    abstract::A new approach to the calculation of the x-ray spectrum emerging from an x-ray tube is proposed. Theoretical results for the bremsstrahlung cross section appearing in the literature are summarized. Four different treatments of electron penetration, based on the work presented in Part I, are then used to generate brems...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2734726

    authors: Poludniowski GG

    更新日期:2007-06-01 00:00:00

  • The physics of cancer therapy with negative pions.

    abstract::The introduction of negative pions into cancer therapy has required the construction of large new proton accelerators together with special magnetic systems to form and direct the pion beam to a patient. A summary is presented of the fundamental properties of pions and of the methods used to study the therapeutic beam...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.594868

    authors: Richman C

    更新日期:1981-05-01 00:00:00

  • Effect of beam number on organ-at-risk sparing in dynamic multileaf collimator delivery of intensity modulated radiation therapy.

    abstract::Due to practical limitations such as inter- and intraleaf transmission, nondivergent leaf end design, and leaf scatter, multileaf collimators (MLCs) are unable to accurately produce the ideal fluence patterns generated by inverse planning systems. Consequently, low dose regions receive substantially more radiation tha...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2779862

    authors: Popple RA,Fiveash JB,Brezovich IA

    更新日期:2007-10-01 00:00:00

  • Robust experiment design for estimating myocardial beta adrenergic receptor concentration using PET.

    abstract::Myocardial beta adrenergic receptor (beta-AR) concentration can substantially decrease in congestive heart failure and significantly increase in chronic volume overload, such as in severe aortic valve regurgitation. Positron emission tomography (PET) with an appropriate ligand-receptor model can be used for noninvasiv...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2402585

    authors: Salinas C,Muzic RF Jr,Ernsberger P,Saidel GM

    更新日期:2007-01-01 00:00:00

  • Geometric studies on variable radius spiral cone-beam scanning.

    abstract::The goal is to perform geometric studies on cone-beam CT scanning along a three-dimensional (3D) spiral of variable radius. First, the background for variable radius spiral cone-beam scanning is given in the context of electron-beam CT/micro-CT. Then, necessary and sufficient conditions are proved for existence and un...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1751251

    authors: Yea Y,Zhu J,Wang G

    更新日期:2004-06-01 00:00:00

  • Calculation of monitor units for a linear accelerator with asymmetric jaws.

    abstract::A simple approach was developed that calculates the output factors and tissue maximum ratio of an asymmetric field at any point within the open field, and specifically both at the central axis (when the jaws do not shadow it) and at the effective center of the open field, using the existing tables for symmetric fields...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597524

    authors: Rosenberg I,Chu JC,Saxena V

    更新日期:1995-01-01 00:00:00

  • Independent quality assurance of a helical tomotherapy machine using the dose magnifying glass.

    abstract:PURPOSE:Helical tomotherapy is a complex delivery technique, integrating CT image guidance and intensity modulated radiotherapy in a single system. The integration of the CT detector ring on the gantry not only allows patient position verification but is also often used to perform various QA procedures. This convenienc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3566067

    authors: Wong JH,Hardcastle N,Tomé WA,Bayliss A,Tolakanahalli R,Lerch ML,Petasecca M,Carolan M,Metcalfe P,Rosenfeld AB

    更新日期:2011-04-01 00:00:00

  • On the assay of brachytherapy sources.

    abstract::In many of brachytherapy procedures, a large amount of radioactive sources are used to deliver desired doses to the target volume. It is both the federal regulation recommendation (U.S. Nuclear Regulatory Commission, 10 CFR 35.432) and recommendations of the American Association of Physicists in Medicine (AAPM) [Kutch...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2734723

    authors: Yue NJ,Haffty BG,Yue J

    更新日期:2007-06-01 00:00:00

  • Investigation of a breathing surrogate prediction algorithm for prospective pulmonary gating.

    abstract:PURPOSE:A major challenge of four dimensional computed tomography (4DCT) in treatment planning and delivery has been the lack of respiration amplitude and phase reproducibility during image acquisition. The implementation of a prospective gating algorithm would ensure that images would be acquired only during user-spec...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3556589

    authors: White BM,Low DA,Zhao T,Wuenschel S,Lu W,Lamb JM,Mutic S,Bradley JD,El Naqa I

    更新日期:2011-03-01 00:00:00

  • Sci-Sat AM(1): Imaging-01: Tumour and normal tissue T2 and ADC distributions for a mouse model at 9.4T.

    abstract::Magnetic resonance (MR) measurements of relaxation times and diffusion coefficient in tissue have been demonstrated to be sensitive to biological changes induced by radiation therapy. We are currently using mouse models of human glioblastoma multiforme (GBM) to study tumour response to ionizing radiation by MRI at 9.4...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965985

    authors: Larocque M,Syme A,Fallone BG

    更新日期:2008-07-01 00:00:00

  • Water-equivalent dosimeter array for small-field external beam radiotherapy.

    abstract::With the increasing complexity of dose patterns external beam radiotherapy, there is a great need for new types of dosimeters. We studied the first prototype of a new dosimeter array consisting of water-equivalent plastic scintillating fibers for dose measurement in external beam radiotherapy. We found that this array...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2719363

    authors: Archambault L,Beddar AS,Gingras L,Lacroix F,Roy R,Beaulieu L

    更新日期:2007-05-01 00:00:00

  • An investigation of a new amorphous silicon electronic portal imaging device for transit dosimetry.

    abstract::The relationship between the pixel value and exit dose was investigated for a new commercially available amorphous silicon electronic portal imaging device. The pixel to dose mapping function was established to be linear for detector distances between 116.5 cm to 150 cm from the source, radiation field sizes from 5 x ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1508108

    authors: Grein EE,Lee R,Luchka K

    更新日期:2002-10-01 00:00:00

  • Task-based assessment of breast tomosynthesis: effect of acquisition parameters and quantum noise.

    abstract:PURPOSE:Tomosynthesis is a promising modality for breast imaging. The appearance of the tomosynthesis reconstructed image is greatly affected by the choice of acquisition and reconstruction parameters. The purpose of this study was to investigate the limitations of tomosynthesis breast imaging due to scan parameters an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3357288

    authors: Reiser I,Nishikawa RM

    更新日期:2010-04-01 00:00:00

  • Dosimetry evaluation of the GammaPod stereotactic radiosurgery device based on established AAPM and IAEA protocols.

    abstract:PURPOSE:The GammaPod is a novel dedicated prone breast stereotactic radiosurgery (SRS) device recently developed at the University of Maryland Medical Center. This device utilizes multiple rotating Co-60 sources to create highly conformal dose distributions for breast treatments, including boosts, partial breast irradi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14197

    authors: Becker SJ,Culberson WS,Poirier Y,Mutaf Y,Niu Y,Nichols EM,Yi B

    更新日期:2020-08-01 00:00:00

  • Signal, noise power spectrum, and detective quantum efficiency of indirect-detection flat-panel imagers for diagnostic radiology.

    abstract::The performance of an indirect-detection, active matrix flat-panel imager (FPI) at diagnostic energies is reported in terms of measured and theoretical signal size, noise power spectrum (NPS), and detective quantum efficiency (DQE). Based upon a 1536 x 1920 pixel, 127 microns pitch array of a-Si:H thin-film transistor...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598243

    authors: Siewerdsen JH,Antonuk LE,el-Mohri Y,Yorkston J,Huang W,Cunningham IA

    更新日期:1998-05-01 00:00:00

  • Application of the convolution method for calculation of output factors for therapy photon beams.

    abstract::The output factor for a therapy photon beam is defined as the dose per monitor unit relative to the dose per monitor unit in a reference field. Convolution models for photon dose calculations yield the dose in units normalized to the incident energy fluence with phantom scatter intrinsically modeled. Output factors ca...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596859

    authors: Ahnesjö A,Knöös T,Montelius A

    更新日期:1992-03-01 00:00:00

  • Absorbed dose in the presence of contrast agents during pediatric cardiac catheterization.

    abstract::Administration of x-ray contrast agents during heart catheterization examination increases the absorbed radiation dose in tissue. To estimate the dose absorbed by the blood of children undergoing diagnostic heart catheterization and angiocardiography, a number of measurements and calculations were conducted. First, en...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594613

    authors: Callisen HH,Norman A,Adams FH

    更新日期:1979-11-01 00:00:00

  • Metallic nanoparticles irradiated by low-energy protons for radiation therapy: Are there significant physical effects to enhance the dose delivery?

    abstract:PURPOSE:To identify which physical properties of nanoparticles are correlated with the survival fraction of cells exposed in vitro to low-energy protons in combination with nanoparticles. METHODS:The Geant4 simulation toolkit (version 10.3) was used to model nanoparticles of different sizes (5-50 nm) and materials (Ti...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12362

    authors: Heuskin AC,Gallez B,Feron O,Martinive P,Michiels C,Lucas S

    更新日期:2017-08-01 00:00:00

  • Displacement-based binning of time-dependent computed tomography image data sets.

    abstract::Respiration can cause tumors in the thorax or abdomen to move by as much as 3 cm; this movement can adversely affect the planning and delivery of radiation treatment. Several techniques have been used to compensate for respiratory motion, but all have shortcomings. Manufacturers of computed tomography (CT) equipment h...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2044427

    authors: Fitzpatrick MJ,Starkschall G,Antolak JA,Fu J,Shukla H,Keall PJ,Klahr P,Mohan R

    更新日期:2006-01-01 00:00:00

  • Fourier transform infrared imaging and small angle x-ray scattering as a combined biomolecular approach to diagnosis of breast cancer.

    abstract::Fourier transform infrared (FTIR) microspectroscopic imaging and small angle x-ray scattering (SAXS) were combined to investigate the supramolecular structure of collagen from 27 tissue sections from patients undergoing mastectomy, excisional biopsy, or mammoplasty. Both techniques were correlated by matching the scat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2890391

    authors: Ooi GJ,Fox J,Siu K,Lewis R,Bambery KR,McNaughton D,Wood BR

    更新日期:2008-05-01 00:00:00

  • SU-E-J-43: Autotuning Imaging Parameters in X-Ray Fluoroscopic Tracking for Dose Savings.

    abstract:PURPOSE:In fluoroscopy-guided clinical procedures that involve tracking objects over long treatment times, there is a need for reducing the amount of imaging dose delivered to the patient and the operating staff. In this study, we introduce a feedback metric to minimize tube current while maintaining a targeting precis...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734878

    authors: Siddique S,Fiume E,Jaffray D

    更新日期:2012-06-01 00:00:00

  • Characteristics and quality assurance of a dedicated open 0.23 T MRI for radiation therapy simulation.

    abstract::A commercially available open MRI unit is under routine use for radiation therapy simulation. The effects of a gradient distortion correction (GDC) program used to post process the images were assessed by comparison with the known geometry of a phantom. The GDC reduced the magnitude of the distortions at the periphery...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1513991

    authors: Mah D,Steckner M,Palacio E,Mitra R,Richardson T,Hanks GE

    更新日期:2002-11-01 00:00:00

  • Indirect flat-panel detector with avalanche gain: fundamental feasibility investigation for SHARP-AMFPI (scintillator HARP active matrix flat panel imager).

    abstract::An indirect flat-panel imager (FPI) with avalanche gain is being investigated for low-dose x-ray imaging. It is made by optically coupling a structured x-ray scintillator CsI(Tl) to an amorphous selenium (a-Se) avalanche photoconductor called HARP (high-gain avalanche rushing photoconductor). The final electronic imag...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2008428

    authors: Zhao W,Li D,Reznik A,Lui BJ,Hunt DC,Rowlands JA,Ohkawa Y,Tanioka K

    更新日期:2005-09-01 00:00:00

  • Improving the calibration of radiochromic films by the use of uncertainties in optical density and dose.

    abstract:PURPOSE:To compare how the inclusion of the uncertainties in dose and optical density affects the results of the calibration of Gafchromic(®) EBT3 radiochromic films. METHODS:Five methods of least square minimization were compared for calibration of radiochromic films. These differed in the way in which the uncertaint...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4811238

    authors: Garcia LI,Azorin JF

    更新日期:2013-07-01 00:00:00

  • Detection nonuniformity measurements and corrections for cone beam transmission CT on a gamma camera.

    abstract::Cone beam transmission CT (CB-CT) improves SPECT imaging by providing high-quality attenuation maps for attenuation compensation and for correlated SPECT and CT imaging. The present work measures the detection nonuniformity for CB-CT implemented with a gamma camera, and applies nonuniformity corrections to make CB-CT ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596838

    authors: Manglos SH,Capone RB,Bassano DA

    更新日期:1992-03-01 00:00:00