Abstract:
PURPOSE:Dosimetry with ionization chambers in clinical ion beams for radiation therapy requires correction for recombination effects. However, common radiation protocols discriminate between initial and general recombination and provide no universal correction method for the presence of both recombination types in ion beams of charged particles heavier than protons. The advent of multiple field optimization in ion beams, allowing for complex patterns of dose delivery in both temporal and spatial domains, results in new challenges for recombination correction where the resulting recombination depends on the plan delivered. Here, the authors present the open source code IonTracks version 1.0, where the combined initial and general recombination effects in principle can be predicted for any ion beam with arbitrary particle-energy spectrum and temporal structure. METHODS:IonTracks uses track structure theory to distribute the charge carriers in ion tracks. The charge carrier movements are governed by a pair of coupled differential equations, based on fundamental physical properties as charge carrier drift, diffusion, and recombination, which are solved numerically while the initial and general charge carrier recombination is computed. A space charge screening of the electric field is taken into account and the algorithm furthermore allows an inclusion of a free-electron component. RESULTS:The algorithm is numerically stable and in accordance with experimentally validated theories for initial recombination in heavy ion tracks and general recombination in a proton beam. CONCLUSIONS:Given IonTracks' ability to handle arbitrary inputs, IonTracks can in principle be applied to any complex particle field in the spatial and temporal domain. IonTracks is validated against the Jaffé's and Boag's theory of recombination in pulsed beams of multiple ion species. IonTracks is able to calculate the correction factor for initial and general recombination losses in parallel-plate ionization chambers. Even if only few experimental data on recombination effects in ionization chambers are available today, the universal concept of IonTracks is not limited to the ions investigated here. Future experimental investigations of recombination in pulsed and possibly also continuous ion beams may be conducted with IonTracks, which ultimately may lead to a more precise prediction of recombination factors in complex radiation fields.
journal_name
Med Physjournal_title
Medical physicsauthors
Christensen JB,Tölli H,Bassler Ndoi
10.1118/1.4962483subject
Has Abstractpub_date
2016-10-01 00:00:00pages
5484issue
10eissn
0094-2405issn
2473-4209journal_volume
43pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::In intensity modulated radiation treatments (IMRT), the position of the field edges and the modulation within the beam are often achieved with a multileaf collimator (MLC). During the MLC calibration process, due to the finite accuracy of leaf position measurements, a systematic error may be introduced to leaf positio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2335490
更新日期:2006-09-01 00:00:00
abstract:PURPOSE:Computerized liver extraction from hepatic CT images is challenging because the liver often abuts other organs of a similar density. The purpose of this study was to develop a computer-aided measurement of liver volumes in hepatic CT. METHODS:The authors developed a computerized liver extraction scheme based o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3395579
更新日期:2010-05-01 00:00:00
abstract::The measurement of the radioactivity administered to the patient is one of the major components of 90Y microsphere liver brachytherapy. The activity of 90Y microspheres in a glass delivery vial was measured in a dose calibrator. The calibration value to use for 90Y in the dose calibrator was verified using an activity...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2731034
更新日期:2007-06-01 00:00:00
abstract:PURPOSE:To compare reconstructed volumes calculated via planimetry and frustum algorithms in the context of stepped transrectal ultrasound (US) imaging, and to estimate the reconstruction error for prostate volumes. METHODS:Prostate contours for 40 permanent implant patients were delineated on magnetic resonance (MR) ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4789920
更新日期:2013-03-01 00:00:00
abstract::As different types of radionuclides (e.g., 131Cs source) are introduced for clinical use in brachytherapy, the question is raised regarding whether a relatively simple method exists for the derivation of values of the half value layer (HVL) or the tenth value layer (TVL). For the radionuclide that has been clinically ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2905356
更新日期:2008-06-01 00:00:00
abstract:PURPOSE:To investigate the optimal use of XR-RV3 GafChromic(®) films to assess patient skin dose in interventional radiology while addressing the means to reduce uncertainties in dose assessment. METHODS:XR-Type R GafChromic films have been shown to represent the most efficient and suitable solution to determine patie...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4922132
更新日期:2015-07-01 00:00:00
abstract::A method is developed to smooth intensity-modulated beam delivery while considering hardware constraints. The method uses matrix algebra to model MLC leaf motion and hardware constraints such as interleaf digitization, synchronization requirements, and intersegment field abutment to deliver intensity modulated beam se...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1521121
更新日期:2002-12-01 00:00:00
abstract:PURPOSE:A new motion-based gated proton therapy for the treatment of orbital tumors using real-time eye-tracking system was designed and evaluated. METHODS:We developed our system by image-pattern matching, using a normalized cross-correlation technique with LabVIEW 8.6 and Vision Assistant 8.6 (National Instruments, ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4729708
更新日期:2012-07-01 00:00:00
abstract::A tomographic attachment was designed and developed that attaches to our existing simulator. The film tomograms obtained with the aid of this device exhibit very low geometrical distortion and good contrast and resolution for the objects used in this investigation. In addition, our results to date show that adjacent a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594662
更新日期:1980-03-01 00:00:00
abstract::We describe a unique method that allows the comparison of spatially registered ultrasound (SRUS) images and computed tomography-derived contours (CTDCs) that were acquired with a minimal time lapse. As such, we have a tool that will provide validation of the spatial accuracy of the US system and that will allow compar...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1644515
更新日期:2004-03-01 00:00:00
abstract::Underlying characteristics in brachytherapy dosimetry parameters for medical radionuclides 137Cs, 125I, 192Ir, 103Pd, and 169Yb were examined using Monte Carlo methods. Sources were modeled as unencapsulated point or line sources in liquid water to negate variations due to materials and construction. Importance of pha...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2199987
更新日期:2006-06-01 00:00:00
abstract:PURPOSE:This study introduces a new hybrid ZTE/Dixon MR-based attenuation correction (MRAC) method including bone density estimation for PET/MRI and quantifies the effects of bone attenuation on metastatic lesion uptake in the pelvis. METHODS:Six patients with pelvic lesions were scanned using fluorodeoxyglucose (18F-...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12122
更新日期:2017-03-01 00:00:00
abstract::For obliquely incident photon beams, the buildup of dose with depth is markedly different from normally incident beams. However, relatively little data on this topic exists for high-energy photon beams of energy greater than 6 MV. Measurements of dose in the buildup region were made using a plane-parallel ionization c...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596055
更新日期:1987-05-01 00:00:00
abstract::Many new models of 125I seeds are being introduced, mainly due to the increase in prostate seed implants. We have evaluated the SourceTech Medical (STM), model STM1251, 125I seed using thermoluminescent dosimeters (TLDs) in a solid water phantom. TLD cubes, LiF TLD-100, with dimension 1 mm on each edge, were irradiate...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1577251
更新日期:2003-07-01 00:00:00
abstract:PURPOSE:The aim of this study was to evaluate a surrogate-driven motion model based on four-dimensional computed tomography that is able to predict CT volumes corresponding to arbitrary respiratory phases. Furthermore, the comparison of three different driving surrogates is examined and the feasibility of using the mod...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12243
更新日期:2017-06-01 00:00:00
abstract:PURPOSE:In current clinical practice, there is no integrated 3D ultrasound (3DUS) guidance system clinically available for breast brachytherapy. In this study, the authors present a novel robot-assisted 3DUS system for real-time planning and guidance of breast interstitial high dose rate (HDR) brachytherapy treatment. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4934832
更新日期:2015-12-01 00:00:00
abstract:PURPOSE:To eliminate or reduce the error to Pareto optimality that arises in Pareto surface navigation when the Pareto surface is approximated by a small number of plans. METHODS:The authors propose to project the navigated plan onto the Pareto surface as a postprocessing step to the navigation. The projection attempt...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4930252
更新日期:2015-10-01 00:00:00
abstract:PURPOSE:Radiation therapy is often delivered by multiple sequential treatment plans. For an accurate radiobiological evaluation of the overall treatment, fractionation corrections to each dose distribution must be applied before summing the three-dimensional dose matrix of each plan since the simpler approach of perfor...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4792636
更新日期:2013-03-01 00:00:00
abstract::The most favorable treatment for moving body anatomy should aim at utilizing organ motion to minimize the dose to sensitive structures without compromising the dose delivered to the target. The solution of the problem of appropriate intensity redistribution over different phases of body motion is achievable in dynamic...
journal_title:Medical physics
pub_type: 信件
doi:10.1118/1.2804722
更新日期:2007-12-01 00:00:00
abstract:PURPOSE:To estimate and correct for the volume averaging effect which results from the intra-chamber dose gradients when a Farmer ionization chamber (IC) is used for reference dosimetry in flattening-filter-free (FFF) MV photon beams. METHODS:An intra-chamber dose gradients correction factor (kicdg) to the charge read...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4958960
更新日期:2016-08-01 00:00:00
abstract:PURPOSE:Arterial distensibility is a marker that can measure vessel wall functional and structural changes resulting from atherosclerosis with applications including estimation of mechanical properties of the wall. We sought to assess the feasibility of using magnetic resonance imaging (MRI) to include wall distensibil...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4754302
更新日期:2012-10-01 00:00:00
abstract::We have developed an analytic solution for spatially resolved diffuse reflectance within the deltaP1 approximation to the radiative transport equation for a semi-infinite homogeneous turbid medium. We evaluate the performance of this solution by comparing its predictions with those provided by Monte Carlo simulations ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2828184
更新日期:2008-02-01 00:00:00
abstract::This study proposes an algorithm for selecting beam weight, wedge angle, and wedge orientation for three-dimensional radiation therapy treatment planning. According to dose gradient analysis, the necessary and sufficient condition for achieving a homogeneous dose over the target volume is that the total vector sum of ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1286591
更新日期:2000-08-01 00:00:00
abstract:PURPOSE:A joint working group was created by the American Association of Physicists in Medicine (AAPM), the European Society for Radiotherapy and Oncology (ESTRO), and the Australasian Brachytherapy Group (ABG) with the charge, among others, to develop a set of well-defined test case plans and perform calculations and ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12459
更新日期:2017-11-01 00:00:00
abstract::A proton dose computational algorithm, performing an analytical superposition of infinitely narrow proton beamlets (ASPB) is introduced. The algorithm uses the standard pencil beam technique of laterally distributing the central axis broad beam doses according to the Moliere scattering theory extended to slablike vary...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2064887
更新日期:2005-12-01 00:00:00
abstract:PURPOSE:Onboard imaging-currently performed primarily by x-ray transmission modalities-is essential in modern radiation therapy. As radiation therapy moves toward personalized medicine, molecular imaging, which views individual gene expression, may also be important onboard. Nuclear medicine methods, such as single pho...
journal_title:Medical physics
pub_type: 信件
doi:10.1118/1.4845195
更新日期:2014-01-01 00:00:00
abstract:PURPOSE:The automated correct segmentation of left and right lungs is a nontrivial problem, because the tissue layer between both lungs can be quite thin. In the case of lung segmentation with left and right lung models, overlapping segmentations can occur. In this paper, the authors address this issue and propose a so...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4894817
更新日期:2014-10-01 00:00:00
abstract:PURPOSE:Within the European project ALLEGRO (grant agreement no. 231965), the out-of-field dose delivered to a patient when treated with different radiotherapy modalities was investigated. The study compared the dose distribution during photon and particle irradiations both in a water and an anthropomorphic phantom to ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735792
更新日期:2012-06-01 00:00:00
abstract::Bioluminescent imaging (BLI) of luciferase-expressing cells in live small animals is a powerful technique for investigating tumor growth, metastasis, and specific biological molecular events. Three-dimensional imaging would greatly enhance applications in biomedicine since light emitting cell populations could be unam...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2138007
更新日期:2006-01-01 00:00:00
abstract:PURPOSE:To design volume-specific breast phantoms from breast CT (bCT) data sets and estimate the associated normalized mean glandular dose coefficients for breast CT using Monte Carlo methods. METHODS:A large cohort of bCT data sets (N = 215) was used to evaluate breast volume into quintiles (plus the top 5%). The av...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12477
更新日期:2017-10-01 00:00:00