Scattered radiation in chest radiography.

Abstract:

:Luminance scatter fractions were measured for patients and phantoms in various regions of the chest film. Scatter fractions were found to be highly variable, being quite high in the regions of the chest with a large equivalent tissue thickness (e.g. mediastinum, chest wall, and subdiaphragmatic areas). For example, approximately 90% of the radiation reaching the mediastinum region of the chest film was found to be scattered radiation when a grid was not used. Even with a 12:1 grid, less than 50% of the available primary beam contrast was being displayed in the mediastinum. In regions of the chest film with high scatter fractions, film latitude was also a problem, further reducing image contrast in these regions. Image contrast and scatter fractions in chest radiography were investigated for different scatter rejection techniques including air gaps, antiscatter grids, and slit radiography.

journal_name

Med Phys

journal_title

Medical physics

authors

Niklason LT,Sorenson JA,Nelson JA

doi

10.1118/1.595027

subject

Has Abstract

pub_date

1981-09-01 00:00:00

pages

677-81

issue

5

eissn

0094-2405

issn

2473-4209

journal_volume

8

pub_type

杂志文章
  • A 4 x 500 mm2 cloverleaf detector system for in vivo bone lead measurement.

    abstract::A 4 x 500 mm2 "cloverleaf" low energy germanium detector array has been assembled for the purpose of in vivo bone lead measurement through x-ray fluorescence. Using 109Cd as an exciting source, results are reported from a leg phantom simulating measurement of lead in a human tibia. For high activity (4.0-4.4 GBq) and ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2436973

    authors: Fleming DE,Mills CE

    更新日期:2007-03-01 00:00:00

  • Image reconstruction for positron emission tomography based on patch-based regularization and dictionary learning.

    abstract:PURPOSE:Positron emission tomography (PET) is an important tool for nuclear medical imaging. It has been widely used in clinical diagnosis, scientific research, and drug testing. PET is a kind of emission computed tomography. Its basic imaging principle is to use the positron annihilation radiation generated by radionu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13804

    authors: Zhang W,Gao J,Yang Y,Liang D,Liu X,Zheng H,Hu Z

    更新日期:2019-11-01 00:00:00

  • Elements of microdosimetry.

    abstract::This is an introductory tutorial to the field of microdosimetry. Following a brief historical outline, we review the physics of experimental and theoretical microdosimetry and the application of microdosimetry to radiation biology within the so-called "site" approximation. Modern interpretations of microdosimetry that...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.596616

    authors: Rossi HH,Zaider M

    更新日期:1991-11-01 00:00:00

  • Dose distributions around cylindrical 241Am sources for a clinical intracavitary applicator.

    abstract::Encapsulated, cylindrical sources containing 2, 5, and 8 Ci of 241Am have been designed and fabricated for intracavitary irradiation of uterine cancers. Exposure rates in air and dose rates in water around these sources have been measured using an ionization chamber and a lithium fluoride thermoluminescent dosimetry s...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596007

    authors: Nath R,Gray L,Park CH

    更新日期:1987-09-01 00:00:00

  • Evaluation of the microangiographic fluoroscope (MAF) using generalized system performance metrics.

    abstract:PURPOSE:The performance of a newly developed, high resolution, microangiographic fluoroscope (MAF) (35 μm pixel pitch and 300 μm thick CsI phosphor) was evaluated using a generalized linear system analysis and compared with that of a standard amorphous Si thin film transistor flat panel detector (FPD) (194 μm pixel pit...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4792460

    authors: Jain A,Bednarek DR,Rudin S

    更新日期:2013-03-01 00:00:00

  • Strategies for scatter correction in dual source CT.

    abstract:PURPOSE:Dual source CT (DSCT) systems utilize two measurement systems (A) and (B) offset by about 90 degrees. A special challenge in DSCT is cross-scattered radiation, i.e., scattered radiation from x-ray tube (B) detected in detector (A) and vice versa. Cross-scattered radiation can produce artifacts and degrade the c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3504606

    authors: Petersilka M,Stierstorfer K,Bruder H,Flohr T

    更新日期:2010-11-01 00:00:00

  • L-curve analysis of radiotherapy optimization problems.

    abstract::We attempt to select an optimal value of regularization parameter in the optimization problems for intensity-modulated radiotherapy which are solved using a variational regularization technique. We apply to inverse treatment planning the L-curve method which was developed to determine the regularization parameter in t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1949750

    authors: Chvetsov AV

    更新日期:2005-08-01 00:00:00

  • Geometric studies on variable radius spiral cone-beam scanning.

    abstract::The goal is to perform geometric studies on cone-beam CT scanning along a three-dimensional (3D) spiral of variable radius. First, the background for variable radius spiral cone-beam scanning is given in the context of electron-beam CT/micro-CT. Then, necessary and sufficient conditions are proved for existence and un...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1751251

    authors: Yea Y,Zhu J,Wang G

    更新日期:2004-06-01 00:00:00

  • X-ray spectral reconstruction from attenuation data using neural networks.

    abstract::An artificial neural network using input data derived from attenuation measurements was trained to generate spectral profiles (relative number of photons versus energy). Once the relative spectral distribution is reconstructed, absolute spectra (number of photons per unit exposure spectral distribution is reconstructe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596495

    authors: Boone JM

    更新日期:1990-07-01 00:00:00

  • SU-D-213CD-03: Live Video-Guided Volumetric Tracking of Respiration Motion.

    abstract:PURPOSE:To introduce video surface imaging guidance in synchronization with 4D cone-beam CT (CBCT) scans, and in combination with respiration- gated or target-tracked dose delivery to treat mobile tumors, without collaterally damaging nearby critical structures. METHODS:The approach uses the concept that the integral ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734688

    authors: Li S,Haiti B,Serratore D,Neicu T,Chan P,Valakh V,Bizhan M,Miyamoto C,Geng J

    更新日期:2012-06-01 00:00:00

  • Plan averaging for multicriteria navigation of sliding window IMRT and VMAT.

    abstract:PURPOSE:To describe a method for combining sliding window plans [intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT)] for use in treatment plan averaging, which is needed for Pareto surface navigation based multicriteria treatment planning. METHODS:The authors show that by taking an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4859295

    authors: Craft D,Papp D,Unkelbach J

    更新日期:2014-02-01 00:00:00

  • Convolutional neural network-based dosimetry evaluation of esophageal radiation treatment planning.

    abstract:PURPOSE:A dosimetry evaluation model for treatment planning of esophageal radiation therapy is developed using a deep learning model. The model predicts dose volume histogram (DVH) from distance to target histogram (DTH) based on stacked de-noise auto-encoder (SDAE) and one-dimensional convolutional network (1D-CN). M...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14434

    authors: Jiang D,Yan H,Chang N,Li T,Mao R,Du C,Guo B,Liu J

    更新日期:2020-10-01 00:00:00

  • Application of spherical diodes for megavoltage photon beams dosimetry.

    abstract:PURPOSE:External beam radiation therapy (EBRT) usually uses heterogeneous dose distributions in a given volume. Designing detectors for quality control of these treatments is still a developing subject. The size of the detectors should be small to enhance spatial resolution and ensure low perturbation of the beam. A hi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4837178

    authors: Barbés B,Azcona JD,Burguete J,Martí-Climent JM

    更新日期:2014-01-01 00:00:00

  • "SABER": A new software tool for radiotherapy treatment plan evaluation.

    abstract:PURPOSE:Both spatial and biological information are necessary in order to perform true optimization of a treatment plan and for predicting clinical outcome. The goal of this work is to develop an enhanced treatment plan evaluation tool which incorporates biological parameters and retains spatial dose information. METH...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3497152

    authors: Zhao B,Joiner MC,Orton CG,Burmeister J

    更新日期:2010-11-01 00:00:00

  • Experimental implementation of a joint statistical image reconstruction method for proton stopping power mapping from dual-energy CT data.

    abstract:PURPOSE:To experimentally commission a dual-energy CT (DECT) joint statistical image reconstruction (JSIR) method, which is built on a linear basis vector model (BVM) of material characterization, for proton stopping power ratio (SPR) estimation. METHODS:The JSIR-BVM method builds on the relationship between the energ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13287

    authors: Zhang S,Han D,Williamson JF,Zhao T,Politte DG,Whiting BR,O'Sullivan JA

    更新日期:2019-01-01 00:00:00

  • Cascaded systems analysis of shift-variant image quality in slit-scanning breast tomosynthesis.

    abstract:PURPOSE:Digital breast tomosynthesis (DBT) is becoming an important part of breast cancer screening and diagnosis. Compared to two-dimensional mammography, tomosynthesis introduces limited three-dimensional (3D) resolution, but maintains high in-plane resolution, low dose, and allows for similar clinical protocols. The...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13116

    authors: Berggren K,Cederström B,Lundqvist M,Fredenberg E

    更新日期:2018-10-01 00:00:00

  • Evaluation of edge effect due to phase contrast imaging for mammography.

    abstract::It is well-known that the edge effect produced by phase contrast imaging results in the edge enhancement of x-ray images and thereby sharpens those images. It has recently been reported that phase contrast imaging using practical x-ray tubes with small focal spots has improved image sharpness as observed in the phase ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1992087

    authors: Matsuo S,Katafuchi T,Tohyama K,Morishita J,Yamada K,Fujita H

    更新日期:2005-08-01 00:00:00

  • Dosimetric characteristics of Novalis shaped beam surgery unit.

    abstract::The dosimetric characteristics of a new dedicated radiosurgical treatment unit are systematically measured in terms of its percent depth dose, beam profile, and relative scatter factor. High-resolution diode detector, mini-ion-chamber detector, and conventional Kodak XV films are used to measure dosimetric data for a ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1494830

    authors: Yin FF,Zhu J,Yan H,Gaun H,Hammoud R,Ryu S,Kim JH

    更新日期:2002-08-01 00:00:00

  • Use of proximal operator graph solver for radiation therapy inverse treatment planning.

    abstract:PURPOSE:Most radiation therapy optimization problems can be formulated as an unconstrained problem and solved efficiently by quasi-Newton methods such as the Limited-memory Broyden-Fletcher-Goldfarb-Shanno (L-BFGS) algorithm. However, several next generation planning techniques such as total variation regularization- b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12165

    authors: Liu X,Pelizzari C,Belcher AH,Grelewicz Z,Wiersma RD

    更新日期:2017-04-01 00:00:00

  • Low-complexity atlas-based prostate segmentation by combining global, regional, and local metrics.

    abstract:PURPOSE:To improve the efficiency of atlas-based segmentation without compromising accuracy, and to demonstrate the validity of the proposed method on MRI-based prostate segmentation application. METHODS:Accurate and efficient automatic structure segmentation is an important task in medical image processing. Atlas-bas...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4867855

    authors: Xie Q,Ruan D

    更新日期:2014-04-01 00:00:00

  • Computerized detection of masses in digital mammograms: automated alignment of breast images and its effect on bilateral-subtraction technique.

    abstract::An automated technique for the alignment of right and left breast images has been developed for use in the computerized analysis of bilateral breast images. In this technique, the breast region is first identified in each digital mammogram by use of histogram analysis and morphological filtering operations. The anteri...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597307

    authors: Yin FF,Giger ML,Doi K,Vyborny CJ,Schmidt RA

    更新日期:1994-03-01 00:00:00

  • Automated registration of large deformations for adaptive radiation therapy of prostate cancer.

    abstract::Available deformable registration methods are often inaccurate over large organ variation encountered, for example, in the rectum and bladder. The authors developed a novel approach to accurately and effectively register large deformations in the prostate region for adaptive radiation therapy. A software tool combinin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3095777

    authors: Godley A,Ahunbay E,Peng C,Li XA

    更新日期:2009-04-01 00:00:00

  • Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy.

    abstract::The objective of this work is to assess the suitability and performance of a new dosimeter system with a novel geometry for the quality assurance (QA) of volumetric modulated arc therapy (VMAT). The new dosimeter system consists of a hollow cylinder (15 and 25 cm inner and outer diameters) with 124 diodes embedded in ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3117563

    authors: Létourneau D,Publicover J,Kozelka J,Moseley DJ,Jaffray DA

    更新日期:2009-05-01 00:00:00

  • Automatic treatment planning based on three-dimensional dose distribution predicted from deep learning technique.

    abstract:PURPOSE:To develop an automated treatment planning strategy for external beam intensity-modulated radiation therapy (IMRT), including a deep learning-based three-dimensional (3D) dose prediction and a dose distribution-based plan generation algorithm. METHODS AND MATERIALS:A residual neural network-based deep learning...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13271

    authors: Fan J,Wang J,Chen Z,Hu C,Zhang Z,Hu W

    更新日期:2019-01-01 00:00:00

  • Direct aperture deformation: an interfraction image guidance strategy.

    abstract::A new scheme, called direct aperture deformation (DAD), for online correction of interfraction geometric uncertainties under volumetric imaging guidance is presented. Using deformable image registration, the three-dimensional geometric transformation matrix can be derived that associates the planning image set and the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2374675

    authors: Feng Y,Castro-Pareja C,Shekhar R,Yu C

    更新日期:2006-12-01 00:00:00

  • The generalized geometry of eye plaque therapy.

    abstract::A calculation is described that enables the rapid assessment of dose rate at various points of interest within the eye (lens, optic nerve, etc.) for the treatment of choroidal melanoma by plaque therapy. 125I seeds are used as the radiation source. The location of the plaque and its associated seeds relative to the ey...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596234

    authors: Kepka AG,Johnson PM,Kline RW

    更新日期:1988-05-01 00:00:00

  • A new technique to characterize CT scanner bow-tie filter attenuation and applications in human cadaver dosimetry simulations.

    abstract:PURPOSE:To present a noninvasive technique for directly measuring the CT bow-tie filter attenuation with a linear array x-ray detector. METHODS:A scintillator based x-ray detector of 384 pixels, 307 mm active length, and fast data acquisition (model X-Scan 0.8c4-307, Detection Technology, FI-91100 Ii, Finland) was use...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4932364

    authors: Li X,Shi JQ,Zhang D,Singh S,Padole A,Otrakji A,Kalra MK,Xu XG,Liu B

    更新日期:2015-11-01 00:00:00

  • Measurement of primary bremsstrahlung spectrum from an 8-MeV linear accelerator.

    abstract::The bremsstrahlung spectrum from an 8-MeV linear accelerator has been measured using a NaI(T1) spectrometer system. The spectrum shows a low-energy cutoff at 0.4 MeV and the maximum photon energy to be approximately 6% greater than the nominal energy. The maximum emission of energy fluence was 1.6 and 1.8 MeV for meas...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594221

    authors: Levy LB,Waggener RG,Wright AE

    更新日期:1976-05-01 00:00:00

  • Development and clinical implementation of semi-automated treatment planning including 3D printable applicator holders in complex skin brachytherapy.

    abstract:PURPOSE:High-dose-rate brachytherapy (HDR-BT) is a treatment option for malignant skin diseases compared to external beam radiation therapy, HDR-BT provides improved target coverage, better organ sparing, and has comparable treatment times. This is especially true for large clinical targets with complex topologies. To ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13975

    authors: Guthier CV,Devlin PM,Harris TC,O'Farrell DA,Cormack RA,Buzurovic I

    更新日期:2020-03-01 00:00:00

  • A Monte-Carlo-based and GPU-accelerated 4D-dose calculator for a pencil beam scanning proton therapy system.

    abstract:PURPOSE:The presence of respiratory motion during radiation treatment leads to degradation of the expected dose distribution, both for target coverage and healthy tissue sparing, particularly for techniques like pencil beam scanning proton therapy which have dynamic delivery systems. While tools exist to estimate this ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13182

    authors: Pepin MD,Tryggestad E,Wan Chan Tseung HS,Johnson JE,Herman MG,Beltran C

    更新日期:2018-11-01 00:00:00