Abstract:
PURPOSE:A dosimetry evaluation model for treatment planning of esophageal radiation therapy is developed using a deep learning model. The model predicts dose volume histogram (DVH) from distance to target histogram (DTH) based on stacked de-noise auto-encoder (SDAE) and one-dimensional convolutional network (1D-CN). METHOD:First, SDAE is used to extract the features from the curves of DTH and DVH. Then 1D-CN model is employed to learn the relationship between the features of DTH and DVH, and later used to predict the features of DVH from the features of DTH. Finally, the curve of DVH is restored from the features of DVH based on SDAE. Two hundred and seventy treatment plans are used for training 1D-CN and another sixty-three treatment plans are used for evaluating this model. This method is also compared with another two popular prediction methods based on support vector machine (SVM) and U-net. RESULTS:Based on the experimental result, the proposed model achieves the lowest dose endpoint error comparing to the other models. The average prediction error on planned target volume, left lung, right lung, heart, and spinal cord is 2.94% for the proposed model, while the average prediction errors are 6.79% and 3.41% for SVM and U-net, respectively. CONCLUSIONS:A dosimetry evaluation method based on SDAE and 1D-CN is developed in characterizing the correlation relationship between DTH and DVH of treatment plans. The results show that the model could be trained more efficiently in this framework and the DVH could be predicted with higher accuracy comparing to those existing methods. It provides a useful tool in supporting automated treatment planning of esophageal intensity-modulated radiotherapy.
journal_name
Med Physjournal_title
Medical physicsauthors
Jiang D,Yan H,Chang N,Li T,Mao R,Du C,Guo B,Liu Jdoi
10.1002/mp.14434subject
Has Abstractpub_date
2020-10-01 00:00:00pages
4735-4742issue
10eissn
0094-2405issn
2473-4209journal_volume
47pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::Positron emission tomography (PET) has shown an increase in both sensitivity and specificity over computed tomography (CT) in lung cancer. However, motion artifacts in the 18F fluorodioxydoglucose (FDG) PET images caused by respiration persists to be an important factor in degrading PET image quality and quantificatio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1448824
更新日期:2002-03-01 00:00:00
abstract:PURPOSE:The purpose of this study was to assess the accuracy of a Monte Carlo simulation-based method for estimating radiation dose from multidetector computed tomography (MDCT) by comparing simulated doses in ten patients to in-vivo dose measurements. METHODS:MD Anderson Cancer Center Institutional Review Board appro...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4906178
更新日期:2015-02-01 00:00:00
abstract:PURPOSE:To examine the response properties of cylindrical cavity ionization chambers (ICs) in the depth-ionization buildup region so as to obtain a robust chamber-signal - based method for definitive water surface identification, hence absolute ionization chamber depth localization. METHOD & MATERIALS:An analytical mo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12319
更新日期:2017-07-01 00:00:00
abstract:PURPOSE:Distortions in magnetic resonance imaging (MRI) compromise spatial fidelity, potentially impacting delineation and dose calculation. We characterized 2D and 3D large field of view (FOV), sequence-independent distortion at various positions in a 1.0 T high-field open MR simulator (MR-SIM) to implement correction...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4930245
更新日期:2015-10-01 00:00:00
abstract::The purpose of this work is to investigate algorithms for the delivery of intensity-modulated fields using independent collimators (IC). Two heuristic algorithms are proposed to calculate jaw-setting sequences for arbitrary 2D intensity distributions. The first algorithm is based on searching the whole intensity matri...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598794
更新日期:1999-12-01 00:00:00
abstract:PURPOSE:To commission and benchmark a vendor-supplied (Varian Medical Systems) Monte Carlo phase-space data for the 6 MV flattening filter free (FFF) energy mode on a TrueBeam linear accelerator for the purpose of quality assurance of clinical volumetric modulated arc therapy (VMAT) treatment plans. A method for render...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4773883
更新日期:2013-02-01 00:00:00
abstract:PURPOSE:To provide specific experience-based guidance and recommendations for centers wishing to develop, validate, and implement an accurate and efficient process for directly using positron emission tomography-computed tomography (PET-CT) for the radiotherapy planning of head and neck cancer patients. METHODS:A PET-...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4867856
更新日期:2014-04-01 00:00:00
abstract::It is known that motion of an object imaged by magnetic resonance imaging leads to errors and artifacts in the image. This effect is especially important when a pulse sequence with long echo time (TE) and long TR is used to provide T2-weighted images. We have modified the usual spin warp imaging pulse sequence in a wa...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596026
更新日期:1987-07-01 00:00:00
abstract:PURPOSE:To develop a fluoroscopy imaging based approach that can determine the magnitude and phase variation in respiratory motion against the treatment planning images in order to quantify the online patient setup deviation in thoracic cancer IGRT for the real time adaptive patient positionadjustment. METHODS:A numer...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734876
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The determination of absorbed dose to water from external beam radiotherapy using radiation detectors is currently rooted in calibration protocols that do not account for modulations encountered in patient-specific deliveries. Detector response in composite clinical fields has not been extensively studied due t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13293
更新日期:2019-02-01 00:00:00
abstract::This paper proposes a new respiratory gated radiation treatment system that allows real-time tumor localization while avoiding invasive operation to a patient. The proposed system employs a three-dimensional (3D) ultrasound device, a 3D digital localizer, and a real-time image processing system. At the planning time, ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1634482
更新日期:2004-02-01 00:00:00
abstract:PURPOSE:The appearance of parenchymal∕stromal patterns in mammography have been characterized as having a Wiener power spectrum with an inverse power-law shape described by the exponential parameter, β. The amount of fibroglandular tissue, which can be quantified in terms of volumetric breast density (VBD), influences ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4736422
更新日期:2012-08-01 00:00:00
abstract::The precision of noninvasive optical measurement of the concentration changes in oxy-, deoxy-, and total-hemoglobin depends on wavelength. For estimating the precision, we calculated the noise level of the concentration changes as the uncertainty in measurements using several wavelength pairs of light. Seven laser dio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1373401
更新日期:2001-06-01 00:00:00
abstract::A proton beam is extracted from the 200-MeV linear accelerator at the Fermi National Accelerator Laboratory to investigate the efficacy of proton radiography in medical diagnosis. Fluence rates from 2 X 10(3) to 2 X 10(5) protons/cm2s over a 28-cm diameter field are obtained with a full width at half-maximum beam-ener...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594426
更新日期:1978-05-01 00:00:00
abstract:PURPOSE:Material-specific imaging and virtual monochromatic imaging/analysis are the two forms of spectral imaging in CT implemented via either energy-integration or photon-counting data acquisition. Aimed at further understanding the fundamentals and providing guidelines on its design and implementation, we quantitati...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14708
更新日期:2021-01-07 00:00:00
abstract:PURPOSE:The authors have developed a quantitative calibration method for a multileaf collimator (MLC) which measures individual leaf positions relative to the MLC backup jaw on an Elekta Synergy linear accelerator. METHODS:The method utilizes a commercially available two-axis detector array (Profiler 2; Sun Nuclear Co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3218767
更新日期:2009-10-01 00:00:00
abstract:PURPOSE:To introduce video surface imaging guidance in synchronization with 4D cone-beam CT (CBCT) scans, and in combination with respiration- gated or target-tracked dose delivery to treat mobile tumors, without collaterally damaging nearby critical structures. METHODS:The approach uses the concept that the integral ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734688
更新日期:2012-06-01 00:00:00
abstract::The authors report on the imaging capabilities of a mammographic system demonstrator based on GaAs pixel detectors operating in single photon counting (SPC) mode. The system imaging performances have been assessed by means of the transfer functions: The modulation transfer function (MTF), the normalized noise power sp...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3097284
更新日期:2009-04-01 00:00:00
abstract:PURPOSE:Robust registration of prone and supine colonie surfaces acquired during CT colonography may lead to faster and more accurate detection of colorectal cancer and polyps. Any directional bias when registering one surface to the other could precipitate incorrect anatomical correspondence and engender reader error....
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4736159
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:There is evidence that computed tomography (CT) and positron emission tomography (PET) imaging metrics are prognostic and predictive in nonsmall cell lung cancer (NSCLC) treatment outcomes. However, few studies have explored the use of standardized uptake value (SUV)-based image features of nodal regions as pre...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4926755
更新日期:2015-08-01 00:00:00
abstract::Extensive information has been made available relative to the physical aspects necessary for calculation of radiation absorbed dose from radiopharmaceuticals. A similar data base for the biological factors involved in these calculations has not been documented as thoroughly. The authors present an extensive literature...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594679
更新日期:1980-05-01 00:00:00
abstract:PURPOSE:Episcleral eye plaque brachytherapy has been utilized in the treatment of intra-ocular malignancies, delivering large prescription doses to the apex of the tumor. Advances in dose calculation and image guidance, via calibrated fundus images, enable localization of the tumor and determination of dose to the macu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735518
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Deformable registration generally relies on the assumption that the sought spatial transformation is smooth. Yet, breathing motion involves sliding of the lung with respect to the chest wall, causing a discontinuity in the motion field, and the smoothness assumption can lead to poor matching accuracy. In respon...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3679009
更新日期:2012-02-01 00:00:00
abstract::A double-mirror multilayer monochromator was developed for the purpose of irradiating live cell cultures at the Synchrotron Radiation Center, University of Wisconsin-Madison. The monochromator is designed for the soft x-ray region with photon energies between 270 and 2400 eV. Multilayer mirrors with 55 bilayers of W/C...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598259
更新日期:1998-05-01 00:00:00
abstract:PURPOSE:Incorporating training into image segmentation is a good approach to achieve additional robustness. This work aims to develop an effective strategy to utilize shape prior knowledge, so that the segmentation label evolution can be driven toward the desired global optimum. METHODS:In the variational image segmen...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4945046
更新日期:2016-05-01 00:00:00
abstract::A spread-out Bragg peak (SOBP) is used in proton beam therapy to create a longitudinal conformality of the required dose to the target. In order to create this effect in a passive beam scattering system, a variety of components must operate in conjunction to produce the desired beam parameters. We will describe how th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2776255
更新日期:2007-10-01 00:00:00
abstract::The Los Alamos code MCNP4A (Monte Carlo N-Particle version 4A) is currently used to simulate a variety of problems ranging from nuclear reactor analysis to boron neutron capture therapy. A graphical user interface has been developed that automatically sets up the MCNP4A geometry and radiation source requirements for a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598167
更新日期:1998-01-01 00:00:00
abstract:PURPOSE:This article aims to introduce a novel algorithm for fast beam angle selection in intensity modulated radiotherapy (IMRT). METHODS:The algorithm models the optimization problem as a beam angle ranking problem and chooses suitable beam angles according to their rank. A new parameter called "beam intensity profi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3517866
更新日期:2010-12-01 00:00:00
abstract:PURPOSE:To develop a new design of an x-ray beam shaper for helical computed tomography (CT) that increases the dose utilization. METHODS:For typical reconstruction algorithms in helical CT, different data are utilized with different weights during back-projection. In particular, data of the outer detector rows, i.e.,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3577766
更新日期:2011-07-01 00:00:00
abstract:PURPOSE:The thermoluminescence dosimeter (TLD) has desirable features including low cost, reusability, small size, and relatively low energy dependence. However, the commonly available poly-crystal TLDs (e.g., TLD-100) exhibit high interdetector variability that requires individual calibration for high detection accura...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13895
更新日期:2020-01-01 00:00:00