"SABER": A new software tool for radiotherapy treatment plan evaluation.

Abstract:

PURPOSE:Both spatial and biological information are necessary in order to perform true optimization of a treatment plan and for predicting clinical outcome. The goal of this work is to develop an enhanced treatment plan evaluation tool which incorporates biological parameters and retains spatial dose information. METHODS:A software system is developed which provides biological plan evaluation with a novel combination of features. It incorporates hyper-radiosensitivity using the induced-repair model and applies the new concept of dose convolution filter (DCF) to simulate dose wash-out effects due to cell migration, bystander effect, and/or tissue motion during treatment. Further, the concept of spatial DVH (sDVH) is introduced to evaluate and potentially optimize the spatial dose distribution in the target volume. Finally, generalized equivalent uniform dose is derived from both the physical dose distribution (gEUD) and the distribution of equivalent dose in 2 Gy fractions (gEUD2) and the software provides three separate models for calculation of tumor control probability (TCP), normal tissue complication probability (NTCP), and probability of uncomplicated tumor control (P+). TCP, NTCP, and P+ are provided as a function of prescribed dose and multivariable TCP, NTCP, and P+ plots are provided to illustrate the dependence on individual parameters used to calculate these quantities. Ten plans from two clinical treatment sites are selected to test the three calculation models provided by this software. RESULTS:By retaining both spatial and biological information about the dose distribution, the software is able to distinguish features of radiotherapy treatment plans not discernible using commercial systems. Plans that have similar DVHs may have different spatial and biological characteristics and the application of novel tools such as sDVH and DCF within the software may substantially change the apparent plan quality or predicted plan metrics such as TCP and NTCP. For the cases examined, both the calculation method and the application of DCF can change the ranking order of competing plans. The voxel-by-voxel TCP model makes it feasible to incorporate spatial variations of clonogen densities (n), radiosensitivities (SF2), and fractionation sensitivities (alpha/beta) as those data become available. CONCLUSIONS:The new software incorporates both spatial and biological information into the treatment planning process. The application of multiple methods for the incorporation of biological and spatial information has demonstrated that the order of application of biological models can change the order of plan ranking. Thus, the results of plan evaluation and optimization are dependent not only on the models used but also on the order in which they are applied. This software can help the planner choose more biologically optimal treatment plans and potentially predict treatment outcome more accurately.

journal_name

Med Phys

journal_title

Medical physics

authors

Zhao B,Joiner MC,Orton CG,Burmeister J

doi

10.1118/1.3497152

subject

Has Abstract

pub_date

2010-11-01 00:00:00

pages

5586-92

issue

11

eissn

0094-2405

issn

2473-4209

journal_volume

37

pub_type

杂志文章
  • Objective characterization of GE discovery CT750 HD scanner: gemstone spectral imaging mode.

    abstract:PURPOSE:To objectively characterize the performance of the gemstone spectral imaging (GSI) mode of GE CT750 HD scanner from a user's perspective. METHODS:A regular scan protocol that approximates the adult abdomen scan protocol frequently used in the authors' institute was selected as the baseline, and a GSI protocol ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3551999

    authors: Zhang D,Li X,Liu B

    更新日期:2011-03-01 00:00:00

  • In vitro in-stent restenoses evaluated by 3D ultrasound.

    abstract::The purpose of this study was to quantify in-stent restenoses with 3D B mode and power Doppler ultrasound (U.S.) imaging. In-stent restenoses were mimicked with vascular phantoms in which a nonferromagnetic prototype stent (Boston Scientific) and a ferromagnetic clinical stainless steel stent (Palmaz P295) were embedd...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3062944

    authors: Lécart M,Cardinal MH,Qin Z,Soulez G,Cloutier G

    更新日期:2009-02-01 00:00:00

  • TU-G-BRB-01: Continuous Path Optimization for Non-Coplanar Variant SAD IMRT Delivery Using C-Arm Machines.

    abstract:PURPOSE:To develop and investigate a continuous path optimization methodology to traverse prescribed non-coplanar IMRT beams with variant SADs, by orchestrating the couch and gantry movement with zero-collision, minimal patient motion consequence and machine travel time. METHODS:We convert the given collision zone def...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735996

    authors: Ruan D,Dong P,Low D,Sheng K

    更新日期:2012-06-01 00:00:00

  • Variations in energy spectra and water-to-material stopping-power ratios in three-dimensional conformal and intensity-modulated photon fields.

    abstract::Because of complex dose distributions and dose gradients that are created in three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiation therapy (IMRT), photon- and electron-energy spectra might change significantly with spatial locations and doses. This study examined variations in photon- and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2710550

    authors: Jang SY,Liu HH,Mohan R,Siebers JV

    更新日期:2007-04-01 00:00:00

  • Performance of a high-sensitivity dedicated cardiac SPECT scanner for striatal uptake quantification in the brain based on analysis of projection data.

    abstract:PURPOSE:The authors have previously reported the advantages of high-sensitivity single-photon emission computed tomography (SPECT) systems for imaging structures located deep inside the brain. DaTscan (Isoflupane I-123) is a dopamine transporter (DaT) imaging agent that has shown potential for early detection of Parkin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4794488

    authors: Park MA,Moore SC,Müller SP,McQuaid SJ,Kijewski MF

    更新日期:2013-04-01 00:00:00

  • Wavelength dependence of the precision of noninvasive optical measurement of oxy-, deoxy-, and total-hemoglobin concentration.

    abstract::The precision of noninvasive optical measurement of the concentration changes in oxy-, deoxy-, and total-hemoglobin depends on wavelength. For estimating the precision, we calculated the noise level of the concentration changes as the uncertainty in measurements using several wavelength pairs of light. Seven laser dio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1373401

    authors: Yamashita Y,Maki A,Koizumi H

    更新日期:2001-06-01 00:00:00

  • Evaluation of a commercial MRI Linac based Monte Carlo dose calculation algorithm with GEANT4.

    abstract:PURPOSE:This paper provides a comparison between a fast, commercial, in-patient Monte Carlo dose calculation algorithm (GPUMCD) and geant4. It also evaluates the dosimetric impact of the application of an external 1.5 T magnetic field. METHODS:A stand-alone version of the Elekta™ GPUMCD algorithm, to be used within th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4939808

    authors: Ahmad SB,Sarfehnia A,Paudel MR,Kim A,Hissoiny S,Sahgal A,Keller B

    更新日期:2016-02-01 00:00:00

  • Continuous time-dependence in computed tomography.

    abstract::Computed tomography is sensitive to changes in the imaged distribution during acquisition of the projection data. Previous investigations have emphasized discrete or discontinuous changes in the imaged object. Recent advances have motivated our investigation of object time-dependence characterized by a continuous func...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594458

    authors: Holden JE,Ip WR

    更新日期:1978-11-01 00:00:00

  • Use of capillary optics as a beam intensifier for a Compton x-ray source.

    abstract::The use of Kumakhov capillary optics will significantly enhance the performance of near-monochromatic, Compton backscattered x-ray programs. The Vanderbilt University Medical Free-Electron Laser Center is developing the capability to create these tunable x rays for medical imaging. The present transport has only refle...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597218

    authors: Tompkins PA,Abreu CC,Carroll FE,Xiao QF,MacDonald CA

    更新日期:1994-11-01 00:00:00

  • Simplifying volumes-of-interest (VOIs) definition in quantitative SPECT: Beyond manual definition of 3D whole-organ VOIs.

    abstract:PURPOSE:We investigated the feasibility of using simpler methods than manual whole-organ volume-of-interest (VOI) definition to estimate the organ activity concentration in single photon emission computed tomography (SPECT) in cases where the activity in the organ can be assumed to be uniformly distributed on the scale...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12164

    authors: Vicente EM,Lodge MA,Rowe SP,Wahl RL,Frey EC

    更新日期:2017-05-01 00:00:00

  • Automatic needle segmentation in three-dimensional ultrasound images using two orthogonal two-dimensional image projections.

    abstract::In this paper, we describe an algorithm to segment a needle from a three-dimensional (3D) ultrasound image by using two orthogonal two-dimensional (2D) image projections. Not only is the needle more conspicuous in a projected (volume-rendered) image, but its direction in 3D lies in the plane defined by the projection ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1538231

    authors: Ding M,Cardinal HN,Fenster A

    更新日期:2003-02-01 00:00:00

  • Computer-aided detection of breast masses: four-view strategy for screening mammography.

    abstract:PURPOSE:To improve the performance of a computer-aided detection (CAD) system for mass detection by using four-view information in screening mammography. METHODS:The authors developed a four-view CAD system that emulates radiologists' reading by using the craniocaudal and mediolateral oblique views of the ipsilateral ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3560462

    authors: Wei J,Chan HP,Zhou C,Wu YT,Sahiner B,Hadjiiski LM,Roubidoux MA,Helvie MA

    更新日期:2011-04-01 00:00:00

  • Reconstruction of diagnostic x-ray spectra by numerical analysis of transmission data.

    abstract::Numerical reconstruction of x-ray spectra from narrow-beam transmission data was tested with published spectra in the range from 45 to 100 kVp. Transmission curves were calculated from the spectra to simulate measured data. Spectra were reconstructed from these transmission curves with use of an iterative numerical an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595834

    authors: Huang PH,Chen TS,Kase KR

    更新日期:1986-09-01 00:00:00

  • SU-E-T-126: Non-Reference Condition Correction Factor KNR of Typical Radiation Detectors for the Dosimetry of High-Energy Photons.

    abstract:PURPOSE:To correct for the deviations of the detector response when typical radiation detectors are used under non-reference conditions, factor kNR was calculated from the known energy dependence of the detector response at photon energies from 10 keV upwards and from clinical photon spectra within a large water phanto...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735184

    authors: Chofor N,Poppe B,Harder D

    更新日期:2012-06-01 00:00:00

  • Lung dosimetry in a linac-MRI radiotherapy unit with a longitudinal magnetic field.

    abstract:PURPOSE:There is interest in developing linac-MR systems for MRI-guided radiation therapy. To date, the designs for such linac-MR devices have been restricted to a transverse geometry where the static magnetic field is oriented perpendicular to the direction of the incident photon beam. This work extends possibilities ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3475942

    authors: Kirkby C,Murray B,Rathee S,Fallone BG

    更新日期:2010-09-01 00:00:00

  • Characterization and identification of spatial artifacts during 4D-CT imaging.

    abstract:PURPOSE:The purpose of this work is twofold: First, to characterize the artifacts occurring in helical 4D-CT imaging; second, to propose a method that can automatically identify the artifacts in 4D-CT images. The authors have designed a process that can automatically identify the artifacts in 4D-CT images, which may be...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3553556

    authors: Han D,Bayouth J,Bhatia S,Sonka M,Wu X

    更新日期:2011-04-01 00:00:00

  • Technical Note: Identification of an optimal electromagnetic sensor for in vivo electromagnetic-tracked scintillation dosimeter for HDR brachytherapy.

    abstract:PURPOSE:Brachytherapy is a treatment modality which delivers large doses of radiation in a reduced number of visits. Since a small number of large dose-per-fraction is administered in high dose rate brachytherapy, ensuring the right dose is delivered is highly critical. In this work, a scintillation detector is coupled...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13508

    authors: Tho D,Beaulieu L

    更新日期:2019-05-01 00:00:00

  • Displacement-based binning of time-dependent computed tomography image data sets.

    abstract::Respiration can cause tumors in the thorax or abdomen to move by as much as 3 cm; this movement can adversely affect the planning and delivery of radiation treatment. Several techniques have been used to compensate for respiratory motion, but all have shortcomings. Manufacturers of computed tomography (CT) equipment h...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2044427

    authors: Fitzpatrick MJ,Starkschall G,Antolak JA,Fu J,Shukla H,Keall PJ,Klahr P,Mohan R

    更新日期:2006-01-01 00:00:00

  • Design for an accelerator-based orthogonal epithermal neutron beam for boron neutron capture therapy.

    abstract::This paper is concerned with the proposed Birmingham accelerator-based epithermal neutron beam for boron neutron capture therapy (BNCT). In particular, the option of producing a therapy beam at an orthogonal direction to the incoming protons is considered. Monte Carlo radiation transport simulations, both with and wit...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598479

    authors: Allen DA,Beynon TD,Green S

    更新日期:1999-01-01 00:00:00

  • Dosimetric properties of the new 125I BrachySeed model LS-1 source.

    abstract::The BrachySeed model LS-1 is one of the latest in a series of new brachytherapy 125I seeds that have recently become available commercially for interstitial implants. The dosimetric properties of the seed were investigated analytically, experimentally, and by Monte Carlo simulation. Following the AAPM Task Group 43 fo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1445411

    authors: Chan GH,Prestwich WV

    更新日期:2002-02-01 00:00:00

  • SU-E-T-382: An Analysis of VMAT Monthly Quality Assurance.

    abstract:PURPOSE:The purpose of this study is to quantify the change in monthly VMAT quality assurance (QA) and determine the tests to maintain consistent delivery with a baseline. METHODS:VMAT monthly QA has been performed for over 14 months on two Elekta Synergy LINACs. A baseline was established at acceptance and the monthl...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735470

    authors: Stenbeck J,Oves S,Gebreamlak W,Alkhatib H

    更新日期:2012-06-01 00:00:00

  • Resin 90Y microsphere activity measurements for liver brachytherapy.

    abstract::The measurement of the radioactivity administered to the patient is one of the major components of 90Y microsphere liver brachytherapy. The activity of 90Y microspheres in a glass delivery vial was measured in a dose calibrator. The calibration value to use for 90Y in the dose calibrator was verified using an activity...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2731034

    authors: Dezarn WA,Kennedy AS

    更新日期:2007-06-01 00:00:00

  • Shimming with permanent magnets for the x-ray detector in a hybrid x-ray/ MR system.

    abstract::In this x-ray/MR hybrid system an x-ray flat panel detector is placed under the patient cradle, close to the MR volume of interest (VOI), where the magnetic field strength is approximately 0.5 T. Immersed in this strong field, several electronic components inside the detector become magnetized and create an additional...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2963994

    authors: Wen Z,Fahrig R,Williams ST,Pelc NJ

    更新日期:2008-09-01 00:00:00

  • Monte Carlo based IMRT dose verification using MLC log files and R/V outputs.

    abstract::Conventional IMRT dose verification using film and ion chamber measurements is useful but limited with respect to the actual dose distribution received by the patient. The Monte Carlo simulation has been introduced as an independent dose verification tool for IMRT using the patient CT data and MLC leaf sequence files,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2208916

    authors: Luo W,Li J,Price RA Jr,Chen L,Yang J,Fan J,Chen Z,McNeeley S,Xu X,Ma CM

    更新日期:2006-07-01 00:00:00

  • Integration of microwave tomography with magnetic resonance for improved breast imaging.

    abstract:PURPOSE:Breast magnetic resonance imaging is highly sensitive but not very specific for the detection of breast cancer. Opportunities exist to supplement the image acquisition with a more specific modality provided the technical challenges of meeting space limitations inside the bore, restricted breast access, and elec...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4820361

    authors: Meaney PM,Golnabi AH,Epstein NR,Geimer SD,Fanning MW,Weaver JB,Paulsen KD

    更新日期:2013-10-01 00:00:00

  • Effect of finite sample size on feature selection and classification: a simulation study.

    abstract:PURPOSE:The small number of samples available for training and testing is often the limiting factor in finding the most effective features and designing an optimal computer-aided diagnosis (CAD) system. Training on a limited set of samples introduces bias and variance in the performance of a CAD system relative to that...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3284974

    authors: Way TW,Sahiner B,Hadjiiski LM,Chan HP

    更新日期:2010-02-01 00:00:00

  • TU-E-217BCD-10: Dose Reduction in Digital Breast Tomosynthesis with the Dose Reduction Prior Image Constrained Compressed Sensing (DR-PICCS) Algorithm.

    abstract:PURPOSE:To reduce image noise and radiation dose in Digital Breast Tomosynthesis (DBT) reconstructions. METHODS:A retrospective study was performed on clinical data sets acquired at a normal dose with Hologic Selenia Dimensions DBT systems. The Prior Image Constrained Compressed Sensing (PICCS) algorithm was used to r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735982

    authors: Garrett J,Tang J,Zhang Y,Ruth C,Jing Z,Chen GH

    更新日期:2012-06-01 00:00:00

  • Accurate technique for complete geometric calibration of cone-beam computed tomography systems.

    abstract::Cone-beam computed tomography systems have been developed to provide in situ imaging for the purpose of guiding radiation therapy. Clinical systems have been constructed using this approach, a clinical linear accelerator (Elekta Synergy RP) and an iso-centric C-arm. Geometric calibration involves the estimation of a s...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1869652

    authors: Cho Y,Moseley DJ,Siewerdsen JH,Jaffray DA

    更新日期:2005-04-01 00:00:00

  • SU-E-J-84: Investigating the Use of Deformable Algorithms to Register and Accumulate Dose to the Spinal Cord for Head-And-Neck Radiotherapy Patients.

    abstract:PURPOSE:Mega-voltage cone-beam CT (MVCBCT) imaging can be used to monitor changes in neck flexion and calculate the true spinal cord dose during radiotherapy. To sum the dose over multiple fractions and compare with the planned dose requires deformable image registration. This study investigates the accuracy of deforma...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734919

    authors: Ueda U,Chen J,Kirby N,Quivey J,Yom S,Pouliot J

    更新日期:2012-06-01 00:00:00

  • Quantitative ionization chamber alignment to a water surface: Theory and simulation.

    abstract:PURPOSE:To examine the response properties of cylindrical cavity ionization chambers (ICs) in the depth-ionization buildup region so as to obtain a robust chamber-signal - based method for definitive water surface identification, hence absolute ionization chamber depth localization. METHOD & MATERIALS:An analytical mo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12319

    authors: Siebers JV,Ververs JD,Tessier F

    更新日期:2017-07-01 00:00:00