Abstract:
PURPOSE:Both spatial and biological information are necessary in order to perform true optimization of a treatment plan and for predicting clinical outcome. The goal of this work is to develop an enhanced treatment plan evaluation tool which incorporates biological parameters and retains spatial dose information. METHODS:A software system is developed which provides biological plan evaluation with a novel combination of features. It incorporates hyper-radiosensitivity using the induced-repair model and applies the new concept of dose convolution filter (DCF) to simulate dose wash-out effects due to cell migration, bystander effect, and/or tissue motion during treatment. Further, the concept of spatial DVH (sDVH) is introduced to evaluate and potentially optimize the spatial dose distribution in the target volume. Finally, generalized equivalent uniform dose is derived from both the physical dose distribution (gEUD) and the distribution of equivalent dose in 2 Gy fractions (gEUD2) and the software provides three separate models for calculation of tumor control probability (TCP), normal tissue complication probability (NTCP), and probability of uncomplicated tumor control (P+). TCP, NTCP, and P+ are provided as a function of prescribed dose and multivariable TCP, NTCP, and P+ plots are provided to illustrate the dependence on individual parameters used to calculate these quantities. Ten plans from two clinical treatment sites are selected to test the three calculation models provided by this software. RESULTS:By retaining both spatial and biological information about the dose distribution, the software is able to distinguish features of radiotherapy treatment plans not discernible using commercial systems. Plans that have similar DVHs may have different spatial and biological characteristics and the application of novel tools such as sDVH and DCF within the software may substantially change the apparent plan quality or predicted plan metrics such as TCP and NTCP. For the cases examined, both the calculation method and the application of DCF can change the ranking order of competing plans. The voxel-by-voxel TCP model makes it feasible to incorporate spatial variations of clonogen densities (n), radiosensitivities (SF2), and fractionation sensitivities (alpha/beta) as those data become available. CONCLUSIONS:The new software incorporates both spatial and biological information into the treatment planning process. The application of multiple methods for the incorporation of biological and spatial information has demonstrated that the order of application of biological models can change the order of plan ranking. Thus, the results of plan evaluation and optimization are dependent not only on the models used but also on the order in which they are applied. This software can help the planner choose more biologically optimal treatment plans and potentially predict treatment outcome more accurately.
journal_name
Med Physjournal_title
Medical physicsauthors
Zhao B,Joiner MC,Orton CG,Burmeister Jdoi
10.1118/1.3497152subject
Has Abstractpub_date
2010-11-01 00:00:00pages
5586-92issue
11eissn
0094-2405issn
2473-4209journal_volume
37pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:To objectively characterize the performance of the gemstone spectral imaging (GSI) mode of GE CT750 HD scanner from a user's perspective. METHODS:A regular scan protocol that approximates the adult abdomen scan protocol frequently used in the authors' institute was selected as the baseline, and a GSI protocol ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3551999
更新日期:2011-03-01 00:00:00
abstract::The purpose of this study was to quantify in-stent restenoses with 3D B mode and power Doppler ultrasound (U.S.) imaging. In-stent restenoses were mimicked with vascular phantoms in which a nonferromagnetic prototype stent (Boston Scientific) and a ferromagnetic clinical stainless steel stent (Palmaz P295) were embedd...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3062944
更新日期:2009-02-01 00:00:00
abstract:PURPOSE:To develop and investigate a continuous path optimization methodology to traverse prescribed non-coplanar IMRT beams with variant SADs, by orchestrating the couch and gantry movement with zero-collision, minimal patient motion consequence and machine travel time. METHODS:We convert the given collision zone def...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735996
更新日期:2012-06-01 00:00:00
abstract::Because of complex dose distributions and dose gradients that are created in three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiation therapy (IMRT), photon- and electron-energy spectra might change significantly with spatial locations and doses. This study examined variations in photon- and...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2710550
更新日期:2007-04-01 00:00:00
abstract:PURPOSE:The authors have previously reported the advantages of high-sensitivity single-photon emission computed tomography (SPECT) systems for imaging structures located deep inside the brain. DaTscan (Isoflupane I-123) is a dopamine transporter (DaT) imaging agent that has shown potential for early detection of Parkin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4794488
更新日期:2013-04-01 00:00:00
abstract::The precision of noninvasive optical measurement of the concentration changes in oxy-, deoxy-, and total-hemoglobin depends on wavelength. For estimating the precision, we calculated the noise level of the concentration changes as the uncertainty in measurements using several wavelength pairs of light. Seven laser dio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1373401
更新日期:2001-06-01 00:00:00
abstract:PURPOSE:This paper provides a comparison between a fast, commercial, in-patient Monte Carlo dose calculation algorithm (GPUMCD) and geant4. It also evaluates the dosimetric impact of the application of an external 1.5 T magnetic field. METHODS:A stand-alone version of the Elekta™ GPUMCD algorithm, to be used within th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4939808
更新日期:2016-02-01 00:00:00
abstract::Computed tomography is sensitive to changes in the imaged distribution during acquisition of the projection data. Previous investigations have emphasized discrete or discontinuous changes in the imaged object. Recent advances have motivated our investigation of object time-dependence characterized by a continuous func...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594458
更新日期:1978-11-01 00:00:00
abstract::The use of Kumakhov capillary optics will significantly enhance the performance of near-monochromatic, Compton backscattered x-ray programs. The Vanderbilt University Medical Free-Electron Laser Center is developing the capability to create these tunable x rays for medical imaging. The present transport has only refle...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597218
更新日期:1994-11-01 00:00:00
abstract:PURPOSE:We investigated the feasibility of using simpler methods than manual whole-organ volume-of-interest (VOI) definition to estimate the organ activity concentration in single photon emission computed tomography (SPECT) in cases where the activity in the organ can be assumed to be uniformly distributed on the scale...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12164
更新日期:2017-05-01 00:00:00
abstract::In this paper, we describe an algorithm to segment a needle from a three-dimensional (3D) ultrasound image by using two orthogonal two-dimensional (2D) image projections. Not only is the needle more conspicuous in a projected (volume-rendered) image, but its direction in 3D lies in the plane defined by the projection ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1538231
更新日期:2003-02-01 00:00:00
abstract:PURPOSE:To improve the performance of a computer-aided detection (CAD) system for mass detection by using four-view information in screening mammography. METHODS:The authors developed a four-view CAD system that emulates radiologists' reading by using the craniocaudal and mediolateral oblique views of the ipsilateral ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3560462
更新日期:2011-04-01 00:00:00
abstract::Numerical reconstruction of x-ray spectra from narrow-beam transmission data was tested with published spectra in the range from 45 to 100 kVp. Transmission curves were calculated from the spectra to simulate measured data. Spectra were reconstructed from these transmission curves with use of an iterative numerical an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595834
更新日期:1986-09-01 00:00:00
abstract:PURPOSE:To correct for the deviations of the detector response when typical radiation detectors are used under non-reference conditions, factor kNR was calculated from the known energy dependence of the detector response at photon energies from 10 keV upwards and from clinical photon spectra within a large water phanto...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735184
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:There is interest in developing linac-MR systems for MRI-guided radiation therapy. To date, the designs for such linac-MR devices have been restricted to a transverse geometry where the static magnetic field is oriented perpendicular to the direction of the incident photon beam. This work extends possibilities ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3475942
更新日期:2010-09-01 00:00:00
abstract:PURPOSE:The purpose of this work is twofold: First, to characterize the artifacts occurring in helical 4D-CT imaging; second, to propose a method that can automatically identify the artifacts in 4D-CT images. The authors have designed a process that can automatically identify the artifacts in 4D-CT images, which may be...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3553556
更新日期:2011-04-01 00:00:00
abstract:PURPOSE:Brachytherapy is a treatment modality which delivers large doses of radiation in a reduced number of visits. Since a small number of large dose-per-fraction is administered in high dose rate brachytherapy, ensuring the right dose is delivered is highly critical. In this work, a scintillation detector is coupled...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13508
更新日期:2019-05-01 00:00:00
abstract::Respiration can cause tumors in the thorax or abdomen to move by as much as 3 cm; this movement can adversely affect the planning and delivery of radiation treatment. Several techniques have been used to compensate for respiratory motion, but all have shortcomings. Manufacturers of computed tomography (CT) equipment h...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2044427
更新日期:2006-01-01 00:00:00
abstract::This paper is concerned with the proposed Birmingham accelerator-based epithermal neutron beam for boron neutron capture therapy (BNCT). In particular, the option of producing a therapy beam at an orthogonal direction to the incoming protons is considered. Monte Carlo radiation transport simulations, both with and wit...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598479
更新日期:1999-01-01 00:00:00
abstract::The BrachySeed model LS-1 is one of the latest in a series of new brachytherapy 125I seeds that have recently become available commercially for interstitial implants. The dosimetric properties of the seed were investigated analytically, experimentally, and by Monte Carlo simulation. Following the AAPM Task Group 43 fo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1445411
更新日期:2002-02-01 00:00:00
abstract:PURPOSE:The purpose of this study is to quantify the change in monthly VMAT quality assurance (QA) and determine the tests to maintain consistent delivery with a baseline. METHODS:VMAT monthly QA has been performed for over 14 months on two Elekta Synergy LINACs. A baseline was established at acceptance and the monthl...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735470
更新日期:2012-06-01 00:00:00
abstract::The measurement of the radioactivity administered to the patient is one of the major components of 90Y microsphere liver brachytherapy. The activity of 90Y microspheres in a glass delivery vial was measured in a dose calibrator. The calibration value to use for 90Y in the dose calibrator was verified using an activity...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2731034
更新日期:2007-06-01 00:00:00
abstract::In this x-ray/MR hybrid system an x-ray flat panel detector is placed under the patient cradle, close to the MR volume of interest (VOI), where the magnetic field strength is approximately 0.5 T. Immersed in this strong field, several electronic components inside the detector become magnetized and create an additional...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2963994
更新日期:2008-09-01 00:00:00
abstract::Conventional IMRT dose verification using film and ion chamber measurements is useful but limited with respect to the actual dose distribution received by the patient. The Monte Carlo simulation has been introduced as an independent dose verification tool for IMRT using the patient CT data and MLC leaf sequence files,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2208916
更新日期:2006-07-01 00:00:00
abstract:PURPOSE:Breast magnetic resonance imaging is highly sensitive but not very specific for the detection of breast cancer. Opportunities exist to supplement the image acquisition with a more specific modality provided the technical challenges of meeting space limitations inside the bore, restricted breast access, and elec...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4820361
更新日期:2013-10-01 00:00:00
abstract:PURPOSE:The small number of samples available for training and testing is often the limiting factor in finding the most effective features and designing an optimal computer-aided diagnosis (CAD) system. Training on a limited set of samples introduces bias and variance in the performance of a CAD system relative to that...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3284974
更新日期:2010-02-01 00:00:00
abstract:PURPOSE:To reduce image noise and radiation dose in Digital Breast Tomosynthesis (DBT) reconstructions. METHODS:A retrospective study was performed on clinical data sets acquired at a normal dose with Hologic Selenia Dimensions DBT systems. The Prior Image Constrained Compressed Sensing (PICCS) algorithm was used to r...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735982
更新日期:2012-06-01 00:00:00
abstract::Cone-beam computed tomography systems have been developed to provide in situ imaging for the purpose of guiding radiation therapy. Clinical systems have been constructed using this approach, a clinical linear accelerator (Elekta Synergy RP) and an iso-centric C-arm. Geometric calibration involves the estimation of a s...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1869652
更新日期:2005-04-01 00:00:00
abstract:PURPOSE:Mega-voltage cone-beam CT (MVCBCT) imaging can be used to monitor changes in neck flexion and calculate the true spinal cord dose during radiotherapy. To sum the dose over multiple fractions and compare with the planned dose requires deformable image registration. This study investigates the accuracy of deforma...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734919
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:To examine the response properties of cylindrical cavity ionization chambers (ICs) in the depth-ionization buildup region so as to obtain a robust chamber-signal - based method for definitive water surface identification, hence absolute ionization chamber depth localization. METHOD & MATERIALS:An analytical mo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12319
更新日期:2017-07-01 00:00:00