Accurate technique for complete geometric calibration of cone-beam computed tomography systems.

Abstract:

:Cone-beam computed tomography systems have been developed to provide in situ imaging for the purpose of guiding radiation therapy. Clinical systems have been constructed using this approach, a clinical linear accelerator (Elekta Synergy RP) and an iso-centric C-arm. Geometric calibration involves the estimation of a set of parameters that describes the geometry of such systems, and is essential for accurate image reconstruction. We have developed a general analytic algorithm and corresponding calibration phantom for estimating these geometric parameters in cone-beam computed tomography (CT) systems. The performance of the calibration algorithm is evaluated and its application is discussed. The algorithm makes use of a calibration phantom to estimate the geometric parameters of the system. The phantom consists of 24 steel ball bearings (BBs) in a known geometry. Twelve BBs are spaced evenly at 30 deg in two plane-parallel circles separated by a given distance along the tube axis. The detector (e.g., a flat panel detector) is assumed to have no spatial distortion. The method estimates geometric parameters including the position of the x-ray source, position, and rotation of the detector, and gantry angle, and can describe complex source-detector trajectories. The accuracy and sensitivity of the calibration algorithm was analyzed. The calibration algorithm estimates geometric parameters in a high level of accuracy such that the quality of CT reconstruction is not degraded by the error of estimation. Sensitivity analysis shows uncertainty of 0.01 degrees (around beam direction) to 0.3 degrees (normal to the beam direction) in rotation, and 0.2 mm (orthogonal to the beam direction) to 4.9 mm (beam direction) in position for the medical linear accelerator geometry. Experimental measurements using a laboratory bench Cone-beam CT system of known geometry demonstrate the sensitivity of the method in detecting small changes in the imaging geometry with an uncertainty of 0.1 mm in transverse and vertical (perpendicular to the beam direction) and 1.0 mm in the longitudinal (beam axis) directions. The calibration algorithm was compared to a previously reported method, which uses one ball bearing at the isocenter of the system, to investigate the impact of more precise calibration on the image quality of cone-beam CT reconstruction. A thin steel wire located inside the calibration phantom was imaged on the conebeam CT lab bench with and without perturbations in source and detector position during the scan. The described calibration method improved the quality of the image and the geometric accuracy of the object reconstructed, improving the full width at half maximum of the wire by 27.5% and increasing contrast of the wire by 52.8%. The proposed method is not limited to the geometric calibration of cone-beam CT systems but can be used for many other systems, which consist of one or more point sources and area detectors such as calibration of megavoltage (MV) treatment system (focal spot movement during the beam delivery, MV source trajectory versus gantry angle, the axis of collimator rotation, and couch motion), cross calibration between Kilovolt imaging and MV treatment system, and cross calibration between multiple imaging systems. Using the complete information of the system geometry, it was demonstrated that high image quality in CT reconstructions is possible even in systems with large geometric nonidealities.

journal_name

Med Phys

journal_title

Medical physics

authors

Cho Y,Moseley DJ,Siewerdsen JH,Jaffray DA

doi

10.1118/1.1869652

subject

Has Abstract

pub_date

2005-04-01 00:00:00

pages

968-83

issue

4

eissn

0094-2405

issn

2473-4209

journal_volume

32

pub_type

杂志文章
  • SU-D-BRCD-02: A Novel Cylindrical 3D Water Scanner for Beam Data Collection: I. Validation of the Automatic-Setup.

    abstract:PURPOSE:To determine the accuracy and reproducibility of the automatic- setup procedure of a 3D water scanner (3D SCANNER, Sun Nuclear Corp). The procedure automatically aligns the scanner's coordinate system to the Linac coordinate system. A unique off-center detector holder extends the scan range to 630 mm, eliminati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734668

    authors: Li J,Lu B,Yan G,Huang Y,Liu C

    更新日期:2012-06-01 00:00:00

  • Design and evaluation of a HDR skin applicator with flattening filter.

    abstract::The purposes of this study are: (i) to design field flattening filters for the Leipzig applicators of 2 and 3 cm of inner diameter with the source traveling parallel to the applicator contact surface, which are accessories of the microSelectron-HDR afterloader (Nucletron, Veenendaal, The Netherlands). These filters, m...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2825622

    authors: Granero D,Pérez-Calatayud J,Gimeno J,Ballester F,Casal E,Crispín V,van der Laarse R

    更新日期:2008-02-01 00:00:00

  • Comparison of Gafchromic EBT2 and EBT3 films for clinical photon and proton beams.

    abstract:PURPOSE:Dose verification in highly conformal radiation therapy such as IMRT or proton therapy can benefit from the high spatial resolution offered by radio-chromic films such as Gafchromic EBT or EBT2. Recently, a new generation of these films, EBT3, has become available. The composition and thickness of the sensitive...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4737890

    authors: Reinhardt S,Hillbrand M,Wilkens JJ,Assmann W

    更新日期:2012-08-01 00:00:00

  • An improved electron energy-loss straggling algorithm for Monte Carlo transport codes.

    abstract::The commonly used Blunck and Leisegang electron energy-loss distribution falls off too rapidly with increasing energy loss. Also, for large thicknesses and/or low-Z media, where their distribution should approach Landau's, it normalizes to 0.92 rather than 1.0, it overestimates the number of very small energy-loss eve...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595500

    authors: Weinhous MS,Nath R

    更新日期:1984-05-01 00:00:00

  • Low-dose cone-beam CT via raw counts domain low-signal correction schemes: Performance assessment and task-based parameter optimization (Part II. Task-based parameter optimization).

    abstract:PURPOSE:Different low-signal correction (LSC) methods have been shown to efficiently reduce noise streaks and noise level in CT to provide acceptable images at low-radiation dose levels. These methods usually result in CT images with highly shift-variant and anisotropic spatial resolution and noise, which makes the par...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12855

    authors: Gomez-Cardona D,Hayes JW,Zhang R,Li K,Cruz-Bastida JP,Chen GH

    更新日期:2018-05-01 00:00:00

  • Application of the convolution method for calculation of output factors for therapy photon beams.

    abstract::The output factor for a therapy photon beam is defined as the dose per monitor unit relative to the dose per monitor unit in a reference field. Convolution models for photon dose calculations yield the dose in units normalized to the incident energy fluence with phantom scatter intrinsically modeled. Output factors ca...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596859

    authors: Ahnesjö A,Knöös T,Montelius A

    更新日期:1992-03-01 00:00:00

  • Electromagnetic guided couch and multileaf collimator tracking on a TrueBeam accelerator.

    abstract:PURPOSE:Couch and MLC tracking are two promising methods for real-time motion compensation during radiation therapy. So far, couch and MLC tracking experiments have mainly been performed by different research groups, and no direct comparison of couch and MLC tracking of volumetric modulated arc therapy (VMAT) plans has...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4946815

    authors: Hansen R,Ravkilde T,Worm ES,Toftegaard J,Grau C,Macek K,Poulsen PR

    更新日期:2016-05-01 00:00:00

  • Investigation of the use of MOSFET for clinical IMRT dosimetric verification.

    abstract::(Received 22 October 2001; accepted for publication 26 March 2002; published 22 May 2002) With advanced conformal radiotherapy using intensity modulated beams, it is important to have radiation dose verification measurements prior to treatment. Metal oxide semiconductor field effect transistors (MOSFET) have the advan...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1481520

    authors: Chuang CF,Verhey LJ,Xia P

    更新日期:2002-06-01 00:00:00

  • Reproducibility of the lung anatomy under active breathing coordinator control: Dosimetric consequences for scanned proton treatments.

    abstract:PURPOSE:The treatment of moving targets with scanned proton beams is challenging. For motion mitigation, an Active Breathing Coordinator (ABC) can be used to assist breath-holding. The delivery of pencil beam scanning fields often exceeds feasible breath-hold durations, requiring high breath-hold reproducibility. We ev...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13195

    authors: den Otter LA,Kaza E,Kierkels RGJ,Meijers A,Ubbels FJF,Leach MO,Collins DJ,Langendijk JA,Knopf AC

    更新日期:2018-12-01 00:00:00

  • Generation of arbitrary intensity profiles by combining the scanning beam with dynamic multileaf collimation.

    abstract::An algorithm, which combines the scanning beam with dynamic collimation to generate any arbitrary intensity profile, is presented. The desired intensity profile is assumed to be piecewise linear. The dynamic collimation method used is the "sliding window." The algorithm can be used either for a given scanning beam pro...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597672

    authors: Spirou SV,Chui CS

    更新日期:1996-01-01 00:00:00

  • The role of water desorption on optical clearing of biotissue: studied with near infrared reflectance spectroscopy.

    abstract::In order to understand the role of water desorption, i.e., the opposite of water adsorption, in optical clearing of biological tissue created by the application of hyperosmotic agents, dynamics of water loss in fresh porcine muscle tissue administrated with glycerol or ethylene glycol was investigated with the near-in...

    journal_title:Medical physics

    pub_type:

    doi:10.1118/1.1576228

    authors: Xu X,Wang RK

    更新日期:2003-06-01 00:00:00

  • SU-E-T-142: Evaluation of the Energy Dependence of Gafchromic EBT3 Film for Electron Beams.

    abstract:PURPOSE:To evaluate the energy dependence of Gafchromic EBT3 film for establishing a quality assurance method of bolus electron conformal radiotherapy. METHODS:We irradiated electron beam to EBT3 films, which were set in the water tank. The linear accelerator used was Varian Clinac 21EX. The energy of electron beams w...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735200

    authors: Inoue T,Sugimoto S,Fukata K,Kurokawa C,Ozawa S,Sasai K

    更新日期:2012-06-01 00:00:00

  • A multimodality segmentation framework for automatic target delineation in head and neck radiotherapy.

    abstract:PURPOSE:To develop an automatic segmentation algorithm integrating imaging information from computed tomography (CT), positron emission tomography (PET), and magnetic resonance imaging (MRI) to delineate target volume in head and neck cancer radiotherapy. METHODS:Eleven patients with unresectable disease at the tonsil...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4928485

    authors: Yang J,Beadle BM,Garden AS,Schwartz DL,Aristophanous M

    更新日期:2015-09-01 00:00:00

  • Detectability of perfusion defect in five-dimensional gated-dynamic cardiac SPECT images.

    abstract:PURPOSE:In previous work, the authors developed and demonstrated the concept of an image reconstruction procedure aimed to unify gated and dynamic nuclear cardiac imaging, which the authors have termed five-dimensional (5D) SPECT. Gated imaging permits the clinician to evaluate wall motion and, through the use of stres...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3481507

    authors: Niu X,Yang Y,King MA,Wernick MN

    更新日期:2010-09-01 00:00:00

  • Measurement of energy dependence for XRCT radiochromic film.

    abstract::Gafchromic XRCT, radiochromic film is assessed over a broad energy range, from kilovoltage to megavoltage x rays for variations in reflected optical density to dose response. A large energy dependence was found with reflected optical density output for the same delivered dose varying from 7.8 +/- 0.35 at 25.5 keV (50 ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2219330

    authors: Butson MJ,Cheung T,Yu PK

    更新日期:2006-08-01 00:00:00

  • A real-time prostate cancer detection technique using needle insertion force and patient-specific criteria during percutaneous intervention.

    abstract::In this article, the authors present a novel real-time cancer detection technique by using needle insertion forces in conjunction with patient-specific criteria during percutaneous interventions. Needle insertion experiments and pathological analysis were performed for developing a computer-aided detection (CAD) model...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3148834

    authors: Yan K,Li L,Joseph J,Rubens DR,Messing EM,Liao L,Yu Y

    更新日期:2009-07-01 00:00:00

  • Effect of surrounding vasculature on intravoxel BOLD signal.

    abstract:PURPOSE:The nonlocal influence from distant magnetization will affect the magnetic field at a voxel in question. Existing reports on BOLD simulation only consider vasculature inside a single voxel, thus omitting the contribution from the surrounding regions. In this article, the authors study the effect of the surround...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3366251

    authors: Chen Z,Caprihan A,Calhoun V

    更新日期:2010-04-01 00:00:00

  • Sci-Fri PM: Planning-03: Fundamental understanding of the inter-relation of arc range, angular dose rate and MLC leaf position optimization of Intensity Modulated Arc Therapy for a concave target.

    abstract::Intensity Modulated Arc Therapy (IMAT) is a rotational variant of Intensity Modulated Radiation Therapy (IMRT) that can be implemented with or without angular dose rate optimization. The purpose of this study is to determine the inter-relationship among arc range, Multi-Leaf Collimator (MLC) leaf positions and angular...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965975

    authors: Oliver M,Chen J,Wong E

    更新日期:2008-07-01 00:00:00

  • Attenuation-based estimation of patient size for the purpose of size specific dose estimation in CT. Part I. Development and validation of methods using the CT image.

    abstract:PURPOSE:For the purpose of size-specific dose estimation, information regarding patient attenuation is required. The purpose of this work is to describe a method for measuring patient attenuation and expressing the results in terms of a water cylinder, with cross sectional area A(w), which would absorb the same average...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4754303

    authors: Wang J,Duan X,Christner JA,Leng S,Yu L,McCollough CH

    更新日期:2012-11-01 00:00:00

  • False-positive reduction in CAD mass detection using a competitive classification strategy.

    abstract::High false-positive (FP) rate remains to be one of the major problems to be solved in CAD study because too many false-positively cued signals will potentially degrade the performance of detecting true-positive regions and increase the call-back rate in CAD environment. In this paper, we proposed a novel classificatio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1344203

    authors: Li L,Zheng Y,Zhang L,Clark RA

    更新日期:2001-02-01 00:00:00

  • Beam scanning for heavy charged particle radiotherapy.

    abstract::An important aspect of heavy charged particle radiotherapy is its ability to localize dose to the target volume. Current techniques generally employ beam delivery schemes which use range modulated beams in which the Bragg peak is spread out over a range of depths. The range modulation is constant over the entire beam ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595419

    authors: Goitein M,Chen GT

    更新日期:1983-11-01 00:00:00

  • Automatic exposure control in multichannel CT with tube current modulation to achieve a constant level of image noise: experimental assessment on pediatric phantoms.

    abstract::Automatic exposure control (AEC) systems have been developed by computed tomography (CT) manufacturers to improve the consistency of image quality among patients and to control the absorbed dose. Since a multichannel helical CT scan may easily increase individual radiation doses, this technical improvement is of speci...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2746492

    authors: Brisse HJ,Madec L,Gaboriaud G,Lemoine T,Savignoni A,Neuenschwander S,Aubert B,Rosenwald JC

    更新日期:2007-07-01 00:00:00

  • Automated bone segmentation from dental CBCT images using patch-based sparse representation and convex optimization.

    abstract:PURPOSE:Cone-beam computed tomography (CBCT) is an increasingly utilized imaging modality for the diagnosis and treatment planning of the patients with craniomaxillofacial (CMF) deformities. Accurate segmentation of CBCT image is an essential step to generate three-dimensional (3D) models for the diagnosis and treatmen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4868455

    authors: Wang L,Chen KC,Gao Y,Shi F,Liao S,Li G,Shen SG,Yan J,Lee PK,Chow B,Liu NX,Xia JJ,Shen D

    更新日期:2014-04-01 00:00:00

  • Toward adaptive radiotherapy for head and neck patients: Uncertainties in dose warping due to the choice of deformable registration algorithm.

    abstract:PURPOSE:The aims of this work were to evaluate the performance of several deformable image registration (DIR) algorithms implemented in our in-house software (NiftyReg) and the uncertainties inherent to using different algorithms for dose warping. METHODS:The authors describe a DIR based adaptive radiotherapy workflow...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4905050

    authors: Veiga C,Lourenço AM,Mouinuddin S,van Herk M,Modat M,Ourselin S,Royle G,McClelland JR

    更新日期:2015-02-01 00:00:00

  • Dosimetric effect of respiration-gated beam on IMRT delivery.

    abstract::Intensity modulated radiation therapy (IMRT) with a dynamic multileaf collimator (DMLC) requires synchronization of DMLC leaf motion with dose delivery. A delay in DMLC communication is known to cause leaf lag and lead to dosimetric errors. The errors may be exacerbated by gated operation. The purpose of this study wa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1592017

    authors: Duan J,Shen S,Fiveash JB,Brezovich IA,Popple RA,Pareek PN

    更新日期:2003-08-01 00:00:00

  • An externally and internally deformable, programmable lung motion phantom.

    abstract:PURPOSE:Most clinically deployed strategies for respiratory motion management in lung radiotherapy (e.g., gating and tracking) use external markers that serve as surrogates for tumor motion. However, typical lung phantoms used to validate these strategies are based on a rigid exterior and a rigid or a deformable-interi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4918581

    authors: Cheung Y,Sawant A

    更新日期:2015-05-01 00:00:00

  • Automated registration of large deformations for adaptive radiation therapy of prostate cancer.

    abstract::Available deformable registration methods are often inaccurate over large organ variation encountered, for example, in the rectum and bladder. The authors developed a novel approach to accurately and effectively register large deformations in the prostate region for adaptive radiation therapy. A software tool combinin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3095777

    authors: Godley A,Ahunbay E,Peng C,Li XA

    更新日期:2009-04-01 00:00:00

  • Energy spectrum based calculation of the half and the tenth value layers for brachytherapy sources using a semiempirical parametrized mass attenuation coefficient formulism.

    abstract::As different types of radionuclides (e.g., 131Cs source) are introduced for clinical use in brachytherapy, the question is raised regarding whether a relatively simple method exists for the derivation of values of the half value layer (HVL) or the tenth value layer (TVL). For the radionuclide that has been clinically ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2905356

    authors: Yue NJ

    更新日期:2008-06-01 00:00:00

  • Assessment of image quality and scatter and leakage radiation of an integrated MR-LINAC system.

    abstract:PURPOSE:To assess the image quality, scatter, and leakage radiation of an integrated magnetic resonance linear accelerator (MR-LINAC or MRL) system. METHODS:A large American College of Radiology (ACR) magnetic resonance imaging (MRI) accreditation phantom was used to evaluate the MRI capabilities of the integrated MRL...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12767

    authors: Wang J,Yung J,Kadbi M,Hwang K,Ding Y,Ibbott GS

    更新日期:2018-03-01 00:00:00

  • Feasibility study of patient-specific energy verification using a multilayer acrylic-disk radiation sensor.

    abstract:PURPOSE:Obtaining an integral depth-dose (IDD) curve using a recently developed acrylic-disk radiation sensor (ADRS) is time-consuming because its single structure requires point-by-point measurements in a water phantom. The goal of this study was to verify the ability of a newly designed multilayer ADRS, composed of 2...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14326

    authors: Son J,Shin D,Kim T,Park S,Rah JE

    更新日期:2020-09-01 00:00:00